journal homepage: www.elsevier.com/locate/apenergy
h i g h l i g h t s
a r t i c l e i n f o a b s t r a c t
Article history: Polygeneration energy systems (PES) have the potential to provide a flexible, high-efficiency, and low-
Received 20 June 2015 emissions alternative for power generation and chemical synthesis from fossil fuels. This study aims to
Received in revised form 10 November 2015 assess the economic value of fossil-fuel PES which rely on hydrogen as an intermediate product. Our anal-
Accepted 6 December 2015
ysis focuses on a representative PES configuration that uses coal as the primary energy input and pro-
Available online 6 January 2016
duces electricity and fertilizer as end-products. We derive a series of propositions that assess the cost
competitiveness of the modeled PES under both static and flexible operation modes. The result is a set
Keywords:
of metrics that quantify the levelized cost of hydrogen, the unit profit-margin of PES, and the real-
Polygeneration
Flexible
option values of ‘diversification’ and ‘flexibility’ embedded in PES. These metrics are subsequently applied
Hydrogen to assess the economics of Hydrogen Energy California (HECA), a PES currently under development in
Economic competitiveness California. Under our technical and economic assumptions, HECA’s levelized cost of hydrogen is esti-
Levelized cost mated at 1.373 $/kgh. The profitability of HECA as a static PES increases in the share of hydrogen con-
Real-option value verted to fertilizer rather than electricity. However, when configured as a flexible PES, HECA almost
breaks even on a pre-tax basis. Diversification and flexibility are valuable for HECA when polygeneration
is compared to static monogeneration of electricity, but these two real options have no value when com-
paring polygeneration to static monogeneration of fertilizers.
Ó 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://
creativecommons.org/licenses/by/4.0/).
http://dx.doi.org/10.1016/j.apenergy.2015.12.008
0306-2619/Ó 2015 The Authors. Published by Elsevier Ltd.
This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
858 K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870
Nomenclature
results in lower carbon dioxide (CO2) emissions [5,6]. In addition, or generated end-products. Second, they facilitate a consistent
the production rates of PES can be either fixed or adjusted over comparison of the economics of polygeneration relative to that of
time. We refer to a system with fixed production rates as ‘static’ monogeneration, with special emphasis on electricity monogener-
or ‘steady-state’ polygeneration and a system with variable pro- ation alternatives (e.g. natural gas or wind). Finally, they quantify
duction rates as ‘flexible’ or ‘dispatchable’ polygeneration [7]. Flex- the value of two real options enabled by polygeneration: the value
ible polygeneration can exploit frequent variations in commodity of diversifying end-products and the value of flexibly varying the
prices; while fuel switching and mixing capabilities help attenuate production rates of end-products over time.
the risks of fuel-price shocks, production diversification and dis- The main motivation for our analysis stems from the fact that
patchability help capture the benefits of product-price peaks different methodologies have been used to evaluate polygenera-
[7,8]. Furthermore, hydrogen markets are currently underdevel- tion economics, including net present value [7,8,12,13], profit
oped [9–11], which renders merchant hydrogen prices an imper- index [12], payout time [14], cost of energy [15,16], and others
fect indicator of cost and value. By converting hydrogen to [17–19]. While each methodology has its own merits, the lack of
valuable commodities, polygeneration offers an incentive to methodological consistency prevents accurate comparison of poly-
expand investments in hydrogen infrastructure. generation economics under different technical assumptions and
The advantages of polygeneration systems merit a rigorous operational settings. The economic metrics we propose offer one
analysis of their economic competitiveness within the broader way to overcome this problem. Specifically, we express all metrics
energy landscape. In this study, we develop a set of generalizable in monetary value per unit of hydrogen produced, for hydrogen is a
metrics that can be used to valuate fossil-fuel polygeneration common intermediate product across polygeneration energy sys-
energy systems. These economic metrics achieve three goals. First, tems of various process configurations and end-product portfolios.
they calculate the levelized cost and profitability of both static and While some previous studies have used the cost of energy (COE)
flexible polygeneration, irrespective of the type of used fossil fuels ($/kWh) to compare polygeneration to monogeneration, such an
K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870 859
approach faces the following challenges. First, polygeneration may production ($/kgh) [21,22]. Consistent with MIT’s The Future of Coal
not necessarily generate electricity as an end-product, in which definition of LCOE [23], this study defines LCOH as: ‘‘the constant
case the use of COE becomes impractical. Second, it is problematic dollar hydrogen price that would be required over the life of a hydro-
to calculate COE as the cost of polygeneration less the cost of other gen plant to cover all operating expenses, payment of debt and accrued
non-electricity products from equivalent monogeneration [15,16]; interest on initial project expenses, and the payment of an acceptable
this method assigns all cost-savings from polygeneration system- return to investors”. In other words, the LCOH is a break-even metric
integration to the power unit and therefore might underestimate that calculates the ratio of ‘lifetime cost’ to ‘lifetime hydrogen pro-
the actual cost of electricity. Our approach addresses this issue duction’ of a facility.
by converting the cost per unit of hydrogen to a cost per unit of The LCOH formulation adopted in this study is similar to the
any end-product, assuming that all hydrogen is converted to that LCOE model in Reichelstein and Yorston [24]. As shown in (1),
single end-product. This methodology facilitates an economic com- the LCOH ($/kgh) is the sum of three terms: cost of capacity per unit
parison between polygeneration and monogeneration systems, output ch , time-averaged fixed operating cost per unit output jh ,
including traditional power plants. and time-averaged variable cost per unit output wh [24,25].1
In addition, an assessment of the economic competitiveness of
LCOH ¼ ch þ jh þ wh ð1Þ
flexible polygeneration systems should include a quantification
of the economic trade-offs associated with operational flexibility. Assuming constant returns-to-scale, the cost of capacity per one
Greater flexibility typically implies not only higher revenues but kilogram of hydrogen can be expressed as:
also higher cost of capacity due to larger equipment size [7,8].
SPh
We address this topic by deriving metrics that capture the eco- ch ð$=kgh Þ ¼ P ð2Þ
nomic impacts of flexible polygeneration, illustrating that produc- m CF Ti¼1 xi ci
tion diversification and flexibility need not always result in SP ($/(kgh/h)) in (2) denotes the system price of acquiring one unit
economic gains [7]. of capacity to produce one kilogram of hydrogen per hour. It
On the technical side, there is an extensive literature on opti- includes the cost of engineering procurement and construction,
mizing the design and operation of PES by combining several tech- contingency, and land purchase. The initial investment yields a
nologies and processes [6,13], incorporating investment planning stream of hydrogen output over T years, with m xi CF kilograms
procedures [20], or investigating the trade-offs associated with delivered in year i. While m ¼ 8760 refers to the total number of
operational flexibility [7]. Other studies also performed detailed hours in a given year, the system degradation factor, xi , accounts
techno-economic analyses on specific polygeneration systems for potential losses in generation capacity over time and is
under various input- and output-portfolios [5,8,14,18,19] and pro- technology-specific. In addition, since the facility may not be online
cess configurations [16,17]. Given the breadth of the available at all times, the practical capacity is only a fraction of the theoretical
technical analysis, our work presumes that polygeneration is tech- capacity. This fraction is represented by the capacity factor, CF. Fur-
nically feasible and focuses predominantly on assessing its eco- thermore, since the LCOH is a break-even formula, it is essential to
nomic value. To that end, we use a simple yet generalizable PES specify an appropriate discount rate. We denote this discount rate
configuration that can operate as both a static and a flexible sys- by s and the corresponding discount factor by c ¼ ð1=1 þ sÞ.2
tem. Building specifically on the work by Chen et al. [7], which Fixed operating costs can change on a yearly basis. The time-
optimizes PES operations under uniform levels of flexibility, we averaged fixed operating cost per one kilogram of hydrogen jh
impose different flexibility limits on different production units to ($/kgh) is shown in (3). SJ i (($/yr)/(kgh/h)) denotes the fixed operat-
explore the effect of real-life operational constraints on PES ing cost incurred by operating one-kilogram-per-hour capacity of
economics. the hydrogen facility in year i. Expenditures in this category
In the following sections, we first introduce the economic con- include labor, administration and overhead, maintenance, and
cepts and technical configuration used in assessing PES. Next, we insurance. While fixed operating costs are assumed to scale pro-
present a detailed economic analysis for the modeled PES in three portionally with the capacity of the facility, they are independent
scenarios; Scenario 1 evaluates static operations while Scenarios of the actual amount of hydrogen generated by the facility.
2a and 2b evaluate two modes of flexible operations. As the main PT
focus of this paper, the economic definitions and derived proposi- i¼1 SJ hi
i
c
jh ¼ PT ð3Þ
tions in all three scenarios are then used to calculate the profit- m CF i¼1 xi ci
margin and real-option values of PES. Lastly, we demonstrate the
applicability of the derived metrics by examining the economic Finally, variable costs can vary over time. Costs in this category
competitiveness of Hydrogen Energy California, a polygeneration include fuel consumption, raw-material inputs, auxiliary loads,
project currently under development. and cash-conversion expenses. We use whi ðtÞ ($/kgh) to denote the
time-dependent variable cost per one kilogram of hydrogen in year
i, and we derive whi ($/kgh) in (4) as the yearly-averaged variable
2. Research methodology cost.
Z m
1
This section describes the economic concepts and technical whi ¼ whi ðtÞdt ð4Þ
specifications used in deriving the valuation metrics for PES. We
m 0
first introduce the levelized cost of hydrogen concept, which is Over the life cycle of the facility, the time-averaged variable cost per
the foundational tool for economic assessment. Then, we explain one kilogram of hydrogen wh ($/kgh) becomes as expressed in (5).
the process configuration, fuel-inputs, and product-outputs of the
adopted fossil-fuel polygeneration system.
vented or
vented N2 used for CCS
CO2
air N2 N2
ASU
CO2 H2 NH3
ammonia fertilizer
O2 steam (H2O) synthesis synthesis
NH3
ammonia fertilizers
storage (e.g. urea)
coal syngas syngas CO2
gasifier clean- SRU HSU ammonia fertilizers
(CO + up H2 H2 subsystem subsystem
H2)
gas
H2 turbine
hydrogen subsystem electricity
steam
turbine
constant flowrate static units
PT PT
m CF xi ci
i¼1 whi i¼1 whi xi ci four ‘subsystems’: hydrogen, electricity, ammonia, and fertilizer.
wh ¼ P ¼ PT ð5Þ While the electricity and ammonia subsystems can be either flexible
m CF Ti¼1 xi ci i¼1 xi c i
or static, the hydrogen and fertilizer subsystems are always static.
Similar notation is used to characterize the time-dependency of all Fig. 1 presents a simplified depiction of the process flow sheet
economic metrics in this study, including prices. For instance, for the polygeneration facility. As shown, coal is first fed into a
Phi ðtÞ; Phi , and Ph refer to the time-dependent price of hydrogen in gasifier where it is mixed with an oxygen (O2) stream from the
year i, the yearly-averaged price of hydrogen in year i, and the air separation unit (ASU) to produce hydrogen-rich syngas. In addi-
time-averaged price of hydrogen, respectively. Referring back to tion to the gasifier and the ASU, the hydrogen production subsys-
the definition of LCOH as a break-even value, we can obtain the fol- tem includes: syngas clean-up units such as particulate removal
lowing benchmark result: unit (PRU), mercury removal unit (MRU), and acid-gas removal
A hydrogen production facility is cost-competitive if and only if: unit (AGRU); shift-reaction unit (SRU); and hydrogen separation
unit (HSU). All these units should run at steady-state [26], resulting
Ph > LCOH ð6Þ
in a fixed output of hydrogen (H2) and carbon dioxide (CO2).
Cost-competitiveness is defined as the ability of the facility to Hydrogen is either fed into a combined-cycle turbine unit for
achieve a positive NPV. Since a PES produces hydrogen as an inter- electricity generation or mixed with nitrogen (N2) from the ASU
mediate product only, the price of hydrogen Ph must be substituted to produce ammonia (NH3), the precursor material for making fer-
with revenue from the hydrogen-enabled end-products, which are tilizers. Both electricity generation [27,28] and ammonia synthesis
commodities with well-defined market prices. Therefore, the for- [26] units can operate flexibly, producing variable power and
mulation in (6) needs to be expanded to assess the economic value ammonia flows. Ammonia is then mixed with a fraction of the
of polygeneration. CO2 stream to produce fertilizer (e.g. urea). The fertilizer synthesis
unit must run at steady-state [26], resulting in a fixed flow of the
2.2. Technical configuration of PES end-product. The remaining CO2 stream is either vented or com-
pressed and transported for geologic sequestration. Finally, since
This study analyzes a simple yet generalizable fossil-fuel PES the steady-state production of fertilizer is dependent on the vari-
configuration, which can operate as either a static or a flexible sys- able production of ammonia, intermediate ammonia storage is
tem. Specifically, we consider a PES that uses coal as fuel, produces necessary to buffer the variations in the ammonia output and
hydrogen then ammonia as intermediate products, and produces secure a fixed ammonia input into the fertilizer subsystem.
electricity and fertilizer (e.g. urea) as final end-products. In the Focusing specifically on the ammonia and electricity subsys-
assumed configuration, coal can be also mixed with biomass or tems, their ranges of flexibility are constrained by system-
petcoke as fuel inputs. integration and efficiency-related standards. For example, part of
In a static PES, all units run at steady-state with fixed output flow- the generated electricity is used for auxiliary load within the facil-
rates. In a flexible PES, however, some units can vary their output ity [26], and power turbines must operate above minimum-
flowrates over time while other units should run at steady-state capacity limits to avoid severe losses in energy efficiency [28]. In
with fixed flowrates in order to maintain acceptable energy- and addition, bounding the range of ammonia production is necessary
chemical-conversation efficiencies [26]. To account for these real- to cap the size ammonia storage; the needed intermediate storage
life operational constraints, and to allow for a generalizable eco- becomes increasingly larger as the range of variable production
nomic assessment, the adopted PES can be conceptually divided into rates becomes wider. We account for these practical flexibility
K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870 861
Electricity
Scenario 1:
Static PES Hydrogen
Ammonia Fertilizers
Electricity
Scenario 2a:
Flexible PES
with flexible Hydrogen
fertilizers Ammonia Fertilizers
subsystem
Electricity
Scenario 2b:
Flexible PES
with static Hydrogen
fertilizers Ammonia Fertilizers
subsystem
Ammonia
Storage
constraints by imposing a lower bound on the production rates may change across years. Section 5.2 discusses the implications
of both electricity and ammonia. The upper bound on production of this assumption in more detail.
rates is imposed by the name-plate capacity of each production
unit. 3.1. Scenario 1: Static PES with fixed production rates
As a result, it is now possible to assess the economic feasibility of Alternatively, in perfectly competitive markets with preset prices,
this static PES by formulating Proposition 1. break-even may be achieved by adjusting production coefficients
on both sides of (12) because k is a controllable design parameter.
Proposition 1. A static polygeneration facility is cost-competitive if In short, a polygeneration facility can break even via multiple port-
and only if: folios of end-product prices and production capacities.
k X e ðP e LIC e Þ
3.2. Scenario 2: Flexible PES with variable production rates
þ ð1 kÞ X f Pf X f LIC f X a LIC a > LCOH ð10Þ
As proven in the derivation of Proposition 1 in Appendix A, the unit For a PES in flexible mode, both electricity and ammonia gener-
revenue for hydrogen in (6), Ph , is replaced with two net-revenue ation rates can vary on an hourly basis; decreasing the power out-
terms, one for each end-product: ðX e Pe X e LIC e Þ corresponding put results in increasing the ammonia output, and vice versa.
to the net revenue from hydrogen conversion to electricity and While a constant hydrogen generation capacity N h is maintained,
the fraction of hydrogen converted to electricity and ammonia
X f Pf X f LIC f X a LIC a corresponding to the net revenue from
hydrogen conversion to ammonia then fertilizer. The net revenue may vary with time. We use the notation kðtÞ in Fig. 2 to highlight
from each end-product is weighted by the fraction of hydrogen this fact. Still, due to flexibility constraints, the condition that
capacity allocated to it: k for electricity and ð1 kÞ for fertilizer. kmin < kðtÞ < kmax remains in place. When kðtÞ ¼ kmax , electricity
Proposition 1 provides several insights. For the static PES to production is maximized while fertilizer production is minimized.
break even, the prices of end-products must be high enough to Conversely, when kðtÞ ¼ kmin , electricity production is minimized
compensate not only for their incremental cost but also for the cost while fertilizer production is maximized.
of hydrogen. Furthermore, optimizing the economic value of the The flexible PES is analyzed sequentially in Scenarios 2a and 2b
static PES requires maximizing hydrogen allocation to the below. Scenario 2a makes the simplifying assumption that the fer-
end-product contributing the highest net revenue. Ultimately, tilizer subsystem can run flexibly, so the variable fertilizer output
this incentivizes setting k ¼ 1 when ðX e Pe X e LIC e Þ P is perfectly synchronized with the variable ammonia output. In
Scenario 2b, we acknowledge the real-world need for a static fertil-
X f Pf X f LIC f X a LIC a and setting k ¼ 0 otherwise; in both
izer subsystem. In other words, Scenario 2a presents a hypothetical
cases, static PES reduces to static monogeneration of either end-
operational configuration that aims to benchmark the performance
product. Therefore, Proposition 1 shows that the profitability of a
of the more realistic Scenario 2b. Comparing these two scenarios
static PES with multiple end-products is bounded by the profitabil-
provides insight into the role of technical constraints in controlling
ity of the static monogeneration of its individual end-products.
the economic value of flexible polygeneration.
To elaborate further on the economics of polygeneration, we
introduce the ‘levelized cost of polygeneration’, or LCOP ($/kgh).
3.2.1. Scenario 2a: Flexible PES with a flexible fertilizer subsystem
Consistent with the earlier definition of LCOH, we define LCOP in
As illustrated in Fig. 2, a variable fertilizer output results from
(11) as a weighted-average price of polygeneration end-products
the direct conversion of the variable ammonia output at each time
that would set the NPV of the PES to exactly zero.
interval t, so no intermediate ammonia storage is needed in this
case. Nonetheless, to accommodate the maximum possible flow-
Definition 2.
rates, the production capacity of the flexible units should be set
at kmax X e (kW) for electricity, ð1 kmin Þ X a (kga/h) for ammonia,
LCOP ¼ LCOH þ k X e LIC e þ ð1 kÞ X f LIC f þ X a LIC a ð11Þ
0
and ð1 kmin Þ X f (kgf/h) for fertilizer.3 Similar to Scenario 1, the
Proposition 1 can then be re-arranged into Proposition 1 in order to incurred capacity and fixed operating costs are scaled by these con-
incorporate the mathematical form of LCOP in Definition 2. stant production capacities, independent of the variable production
0 rates.
Proposition 1 . A static polygeneration facility is cost-competitive if Since both capacity and fixed operating costs are constant in a
and only if:
given year i, maximizing the profitability of the flexible PES
k X e Pe þ ð1 kÞ X f Pf > LCOP ð12Þ requires maximizing the ‘contribution margin’ of hydrogen conver-
sion at every point in time t of that year.4 Definition 3 introduces
The LCOP formulation in (11) shows that the levelized cost of a sta- CMe ($/kgh) and CMf ($/kgh) as the contribution margins associated
tic PES can be expressed as the sum of the levelized cost of its oper- with converting one kilogram of hydrogen to X e kilowatt hours of
ational subsystems weighted by their respective production electricity and X f kilograms of fertilizer, respectively.
coefficients. While the levelized costs of individual subsystems
can be calculated using multiple units, (e.g. $/kWh for LIC e ), the con- Definition 3.
version rates X e ; X a , and X f ensure that the overall PES cost is
expressed as a monetary value per unit of hydrogen. Clearly, this CMei ðtÞ ¼ ½X e Pei ðtÞ X e wei ðtÞ ð13Þ
approach facilitates comparing the cost of different polygeneration
CMfi ðtÞ ¼ X f Pfi ðtÞ X f wfi ðtÞ X a wai ðtÞ ð14Þ
systems with different configurations, all of which produce hydro-
gen as an intermediate product.
Furthermore, while (6) shows that the revenue from monogen-
0
eration is dictated by only one price, Proposition 1 in (12) shows
that the revenue from polygeneration is determined by a sum of
end-product prices weighted by their respective production coeffi- 3
Our analysis speaks to the cost competitiveness of a flexible PES whose capacity is
cients. Consequently, for a fixed operation mode and thus fixed set chosen to accommodate the maximum possible flowrate of ammonia. In future work,
of production coefficients, multiple combinations of end-product it would be desirable to explore under what conditions a flexible PES, accommodating
prices may achieve break-even. In imperfectly competitive a lower flowrate but requiring correspondingly smaller capacity investments, could
be more economical.
markets, the PES firm can negotiate multiple portfolios of end- 4
Contribution margin refers to the difference between sales and variable costs. The
product prices with potential buyers. For instance, the firm may analysis in Reichelstein and Sahoo [45] explains a related idea on quantifying the
sell electricity at a competitive market price while having pricing temporal co-variation between prices and generation capacity of an intermittent
power in selling fertilizers due to constrained regional supply. power source.
K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870 863
When CM ei ðtÞ > CMfi ðtÞ, electricity production should be maximized X e ½Pe LIC e
and fertilizer production should be minimized; the opposite must þ ð1 kmin Þ ICMF f X f cf þ jf X a ðca þ ja Þ
hold when CMei ðtÞ < CM fi ðtÞ. Accordingly, we divide the yearly
ð1 kmax Þ ½ICMF e X e ðce þ je Þ > LCOH ð22Þ
hours m into me and mf , introduced in Definition 4. mei (h) corre-
sponds to the number of hours in year i when CM ei ðtÞ P CMfi ðtÞ As proven in Appendix A, the left-hand sides in (21) and (22) are
whereas mfi (h) corresponds to the number of hours when identical. The formulation in (21) benchmarks flexible polygenera-
CM ei ðtÞ < CMfi ðtÞ.5 Clearly, m ¼ mfi þ mei for every year i. tion against static fertilizer monogeneration. Specifically, the net
revenue from hydrogen conversion is divided into three terms. As
Definition 4. in Scenario 1, the first term X f Pf X f LIC f X a LIC a corre-
mei ¼ lð m
e ei Þ ¼ l tj0 6 t 6 m; CM ei ðtÞ P CM fi ðtÞ ð15Þ sponds to the net revenue from the static monogeneration of fertil-
izer. The second and third terms correspond to the additional net
mfi ¼ l m
e fi ¼ l tj0 6 t 6 m; CM ei ðtÞ < CM fi ðtÞ ð16Þ revenues from flexibility. kmax ½ICMF e X e ðce þ je Þ represents the
net revenue associated with flexible switching from fertilizer to
Flexibility enables choosing the highest contribution margin in electricity; the flexibility-enabled incremental contribution margin
every time period. Thus, we define the difference between CM ei ðtÞ is weighed against the flexibility-required capacity and fixed oper-
and CM fi ðtÞ as the ‘incremental contribution margin of flexibility’ ating costs of generating electricity. This ‘gained’ net revenue is
ðICMF Þ. In a given year i; ICMF ei is the yearly-averaged sum of scaled by kmax , the maximum fraction of hydrogen capacity allo-
flexibility-enabled contribution margin over m e ei hours, attributed cated to electricity. On the other hand, electricity generation cannot
to switching hydrogen allocation from fertilizer to electricity. drop below a lower limit defined by kmin , so the corresponding
Equivalently, ICMF fi is the yearly-averaged sum of flexibility- net revenue associated with flexible switching from electricity
enabled contribution margin over m e fi hours, attributed to switching to fertilizer is ‘lost’. This net revenue is captured in
hydrogen allocation from electricity to fertilizer. ICMF ei ($/kgh) and kmin ICMF f X f cf þ jf X a ðca þ ja Þ , which balances the
ICMF fi ($/kgh) are introduced in Definition 5. By design, both terms flexibility-enabled incremental contribution margin against the
are always positive. flexibility-required capacity and fixed operating costs of generating
ammonia then fertilizer.
Definition 5. The formulation in (22) has a similar and symmetric structure
Z
1 to (21), but it benchmarks the economics of the flexible polygener-
ICMF ei ¼ CM ei ðtÞ CM fi ðtÞ dt ð17Þ ation against static electricity monogeneration. In this case, the
m ~ ei
m
Z ‘gained’ and ‘lost’ net-revenue terms associated with flexibility
1
ICMF fi ¼ CM fi ðtÞ CM ei ðtÞ dt ð18Þ are scaled by ð1 kmin Þ and ð1 kmax Þ, corresponding to the maxi-
m ~ fi
m
mum and minimum fractions of hydrogen that can be converted
The formulation of ICMF illustrates the beneficial impacts of price to fertilizer, respectively.
volatility on the economics of flexible PES. Consistent with the ear- In both (21) and (22), the ‘gained’ and ‘lost’ net-revenue terms
lier assumption that only electricity price Pei ðtÞ changes over time, associated with flexibility are positive only when the incremental
the effect of higher volatility in P ei ðtÞ is captured in two ways: contribution margin surpasses the capacity and fixed operating
higher Pei ðtÞ leads to higher CM ei ðtÞ during mei hours and therefore costs. Thus, Proposition 2a shows that adding flexibility to a PES
higher ICMF ei , and lower Pei ðtÞ leads to lower CMei ðtÞ during mfi may not result in superior economic value; the latter depends on
hours and therefore higher ICMF fi . In short, the higher the price the specifications of the investigated facility. We analyze this
volatility (around the same price average), the higher the incremen- dependency in more detail in Section 4. Also, (21) and (22) show
tal contribution margin of flexibility. that maximizing the revenue of flexible polygeneration requires
Similar to the time-averaged variable cost in (6), the time- exploiting the ability to vary kðtÞ between kmin and kmax ; setting
averaged incremental contribution margins of flexibility ICMF e kmin ¼ kmax ¼ k reduces Proposition 2a to Proposition 1.
($/kgh) and ICMF f ($/kgh) are derived from ICMF ei and ICMF fi in
(19) and (20), respectively. 3.2.2. Scenario 2b: Flexible PES with a static fertilizer subsystem
PT We now analyze a flexible PES with a static fertilizer subsystem.
i¼1 ICMF ei xi c i
ICMF e ¼ PT ð19Þ Compared to Scenario 2a, this operational mode induces two tech-
i¼1 xi
i c nical updates. First, intermediate ammonia storage is needed to
PT
i¼1 ICMF fi xi ci buffer the variable ammonia output ð1 kðtÞÞ X a (kga/h) and
ICMF f ¼ PT ð20Þ secure a fixed ammonia input K X a (kga/h) into the fertilizer pro-
i¼1 xi
i c
cessing unit. Intuitively, ammonia is withdrawn from storage to
As a result, we can now assess the economic feasibility of the flex- compensate for shortage when ð1 kðtÞÞ < K, and it is added to
ible PES in this simplified scenario by formulating two mathemati- storage to save excess when ð1 kðtÞÞ > K. The storage capacity
cally equivalent statements of Proposition 2a. is denoted by Sa (kga), and we assume optimized storage opera-
tions. Specifically, the site can always accommodate the addition
Proposition 2a. A flexible PES is cost-competitive if and only if: or withdrawal of ammonia at any rate. Also, all ammonia produced
in a given year is converted to fertilizer, resulting in no annual net-
X f Pf X f LIC f X a LIC a
storage. These two conditions maintain the underlying assumption
þ kmax ½ICMF e X e ðce þ je Þ that mei and mfi are the same in every year i throughout the
kmin ICMF f X f cf þ jf X a ðca þ ja Þ > LCOH ð21Þ facility’s lifetime.
Second, because the fertilizer output is fixed, no excess capacity
Equivalently, the flexible PES is cost-competitive if and only if:
is needed to accommodate variable production. Therefore, the
capacity of the fertilizer subsystem is reduced from ð1 kmin Þ X f
to K X f (kgf/h). A yearly mass balance on ammonia production
5
in (15) and (16) is the Lebesgue Measure over the set of real numbers between allows defining K in terms of k, as depicted in (23). As explained
and [46]. before, ammonia production is minimized during me hours but
864 K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870
maximized during mf hours. Equating the yearly variable output levelized cost. We use PM as a profitability metric to assess and
from the ammonia subsystem to the yearly fixed input into the fer- compare PES under different operation modes.
tilizer subsystem results in K ¼ me ð1 kmax Þ þ mf ð1 kmin Þ =m. X
T
NPVð$Þ ¼ PM m CF ci xi ð27Þ
me ð1 kmax Þ þ mf ð1 kmin Þ X f ¼ m K X f ð23Þ i¼1
With these modifications, we can now assess the economic feasibil- PM0 measures the unit profit-margin of a static single-output plant.
ity of flexible polygeneration in this scenario by deriving two equiv- PM0f ($/kgh) refers to the profit-margin of a static plant that con-
alent statements of the new Proposition 2b. verts all hydrogen to ammonia and then fertilizer (k ¼ 0). Similarly,
PM0e ($/kgh) refers to the profit-margin of a static power plant that
Proposition 2b. A flexible PES is cost-competitive if and only if: converts all hydrogen to electricity (k ¼ 1). PM0f and PM 0e are for-
mally defined in (28) and (29), respectively.
X f Pf X f LIC f X a LIC as
PM0f ¼ X f Pf X f LIC f X a LIC a LCOH ð28Þ
þ kmax ½ICMF e X e ðce þ je Þ
kmin ICMF f X f cf þ jf X a ðcas þ jas Þ PM0e ¼ X e P e X e LIC e LCOH ð29Þ
þ ð1 kmin K Þ X f cf þ jf > LCOH ð24Þ Let PM1 ($/kgh) denote the unit profit-margin of the static PES in
Scenario 1, which can be directly deduced from Proposition 1.
Equivalently, the flexible PES is cost-competitive if and only if:
PM1 is derived in (30) by re-arranging the terms in (10).
X e ½Pe LIC e PM1 ¼ k X e ðPe LIC e Þ
þ ð1 kmin Þ ICMF f X f cf þ jf X a ðcas þ jas Þ þ ð1 kÞ X f Pf X f LIC f X a LIC a LCOH ð30Þ
ð1 kmax Þ ½ICMF e X e ðce þ je Þ
Similarly, PM 2 ($/kgh) refers to the unit profit-margin of the flexible
þ ð1 kmin K Þ X f cf þ jf > LCOH ð25Þ PES in Scenario 2, which is obtained directly from Proposition 2b.
A detailed derivation of (24) and (25) is presented in Appendix A. PM2 can be expressed in two forms, PM2f ($/kgh) and PM2e ($/kgh),
The formulations in (24) and (25) are identical to those in (21) and presented in (31) and (32), respectively. PM2f is derived from (24)
(22) for Scenario 2a, except for two differences. First, to account where the economic value of a flexible PES is benchmarked against
for storage, the levelized-cost terms of ammonia ca , ja , and wa that of a static fertilizer plant, and PM 2e is derived from (25) where
are updated to cas , jas , and was , respectively; other metrics the economic value of a flexible PES is benchmarked against that of
incorporating these terms are also updated accordingly. Second, a static power plant. Importantly, we note that PM 2e ¼ PM 2f .
reducing the fertilizer capacity from ð1 kmin Þ in Scenario 2a PM2f ¼ X f Pf X f LIC f X a LIC as
to K in Scenario 2b results in a net-revenue ‘gain’ of
þ kmax ½ICMF e X e ðce þ je Þ
ð1 kmin K Þ X f cf þ jf , which accounts for savings in capac-
kmin ICMF f X f cf þ jf X a ðcas þ jas Þ
ity and fixed operating costs. All other economic expressions intro-
duced in Scenario 2a remain valid here. Notably, the flexible PES þ ð1 kmin K Þ X f cf þ jf LCOH ð31Þ
still captures the full economic benefits of flexibility even though
the fertilizer subsystem is static. Because storage allows all gener- PM2e ¼ X e ½Pe LIC e
ated ammonia to be eventually converted to fertilizer, flexible þ ð1 kmin Þ ICMF f X f cf þ jf X a ðcas þ jas Þ
ammonia generation is sufficient to sustain the economic benefits
ð1 kmax Þ ½ICMF e X e ðce þ je Þ
of flexible fertilizer generation.
þ ð1 kmin K Þ X f cf þ jf LCOH ð32Þ
me ðkmax kmin Þ
1 kmin K ¼ ð26Þ These profitability metrics can be directly used to quantify the value
m
of real options enabled by polygeneraion. We first define VOD as the
Using (23) to expand the formulation of K, we find that
‘value of diversification’ from a single output to a portfolio of
ð1 kmin K Þ is directly proportional to me , as shown in (26). A lar-
multiple outputs. VODf ($/kgh) is the difference between the
ger me means that the flexible PES spends more time maximizing
profit-margin of static polygeneration PM 1 and that of static mono-
electricity generation on the expense of fertilizer generation. In this
generation of fertilizer PM0f ; similarly, VODe ($/kgh) is the difference
case, a smaller static fertilizer subsystem with intermediate ammo-
between PM1 and PM0e . Clearly, both VODf and VODe are dependent
nia storage (Scenario 2b) may achieve better economics than a lar-
on k, as shown in (33) and (34), respectively.
ger flexible fertilizer subsystem with no storage (Scenario 2a), even
if the latter is technically feasible. VODf ðkÞ ¼ PM1 ðkÞ PM0f ð33Þ
dependent on k, as highlighted in (35). This formulation shows that X f Pf X f LIC f X a LIC as
flexible polygeneration is more profitable than static polygenera- þ kmax ½ICMF e X e ðce þ je Þ
tion only if VOFðkÞ > 0. There might exist some value of k for which
kmin ICMF f X f cf þ jf X a ðcas þ jas Þ
a static PES could outperform a flexible PES, in which case VOFðkÞ is
negative. þ ð1 kmin K Þ X f cf þ jf þ U c ðP c LIC c Þ > LCOH ð39Þ
If all prices and variable costs are allowed to vary with time, Propo-
5. Additional modeling considerations
sition 2b can be easily revised to incorporate Uf and Ue , as illus-
trated in (42).
5.1. Carbon capture and storage
00
Proposition 2b . A flexible PES is cost-competitive if and only if:
The proposed economic assessment of PES can be robustly
expanded to account for technical supplements such as carbon
X f P f X f LIC f X a LIC as
capture and storage (CCS). The net CO2 output, defined as the gross
þ kmax ½ICMF e X e ðce þ je Þ
CO2 production less the CO2 used for fertilizer synthesis, may be
compressed then transported in pipelines to be either geologically kmin ICMF f X f cf þ jf X a ðcas þ jas Þ
sequestered or used for enhanced oil recovery [23]. Since CO2 is þ ð1 kmin K Þ X f cf þ jf kmax Ue þ kmin Uf > LCOH ð42Þ
produced by a steady-state process (gasification) and partially uti-
lized by another steady-state process (fertilizer synthesis), its net 6. Case study: Hydrogen Energy California
output is a fixed flow, regardless of whether the PES is static of
flexible. To demonstrate the usefulness of our model analysis in the pre-
CCS is treated as a separate subsystem of production capacity vious sections, we now assess the economic performance of Hydro-
U c N h (kgc/h), where U c (kgc/kgh) denotes the net CO2 output rate gen Energy California (HECA), a polygeneration facility currently
per one kilogram of produced hydrogen. As before, LIC c refers to under development in California.
the sum of cc , jc , and wc , which correspond to the cost of capacity,
time-averaged fixed operating cost, and time-averaged variable 6.1. Technical configuration
cost of CCS per unit of CO2 ($/kgc), respectively. Also, if sold for
enhanced oil recovery, the CO2 output generates revenue propor- Consistent with the technical configuration presented in Sec-
tional to its price Pc ($/kgc). As such, Propositions 1 and 2b can tion 2.2, HECA uses a gasification technology to convert coal and
be revised to incorporate CCS in a static and a flexible PES, as petcoke into clean-burning hydrogen. As an intermediate product,
shown in (38) and (39), respectively. All other economic metrics hydrogen is then converted to electricity and ammonia, which is
and propositions can be updated accordingly. further processed into urea and UAN – a solution of urea and
ammonium nitrate [31,32]. The operational configuration of HECA
00
Proposition 1 . A static PES with CCS is cost-competitive if and only allows flexible generation of electricity and ammonia, but it
if: requires static generation of hydrogen, urea, and UAN; the facility
also includes a CO2 compression unit, which can be treated as a
k X e ðPe LIC e Þ separate static CCS subsystem.
þ ð1 kÞ X f Pf X f LIC f X a LIC a The first task is to quantify all technical parameters needed for
þ U c ðPc LIC c Þ > LCOH ð38Þ the economic evaluation. A list of HECA’s technical parameters and
their values is provided in Table 1. With a capacity factor of
0
Proposition 2b . A flexible PES with CCS is cost-competitive if and CF ¼ 0:835 and an expected operational lifetime of 25 years, the
only if: facility consumes coal and petcoke at rates equal to roughly
866 K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870
Table 1 Table 3
HECA technical parameters. Levelized costs of capacity of HECA.
Table 2
HECA auxiliary loads.
Table 5
System/unit Peak mode Off-peak mode Unit Reference Levelized time-averaged variable costs of HECA.
Hydrogen subsystem 170 164 MW [34]
Cost Value Unit
Electricity subsystem 12 12 MW [34]
Ammonia subsystem 10 17 MW [Estimated] wh 0.640 $/kgh
Urea + UAN subsystem 15 15 MW [Estimated] we 0.00119 $/kWh
CO2 subsystem 40 40 MW [34] wa 0.00644 $/kga
Total 247 248 MW [34] was 0.00644 $/kga
wf 0.00836 $/kgurea
wc 0.00339 $/kgc
annual discount rate of s ¼ 0:07 and no degradation in productivity 6.2.2. Economic value
over the years (x ¼ 1) for all cost figures. The aforementioned data allows us to calculate the derived
Table 3 lists the levelized costs of capacity for the five major metrics in Sections 3 and 4 and therefore to assess the economic
subsystems of HECA. Since the size of HECA is comparable to that value of HECA under several operation modes. The results are pre-
of the facilities analyzed in the referenced literature, linear scaling sented in Table 7.
factors are used to calculate the capacity cost of each subsystem. The levelized cost of hydrogen production is estimated at
Also, we recall that cas and ca correspond to the capacity costs of LCOH = 1.373 $/kgh. This cost can be combined with the cost of
the ammonia subsystem with and without intermediate storage, the electricity and CCS subsystems to calculate an LCOE for HECA,
respectively. as illustrated in (46). Notably, the obtained LCOE = 0.0953 $/kWh
The yearly fixed operating costs are calculated as a constant is comparable to that of coal power plants with CO2 capture, cur-
fraction of the overall capacity cost (refer to Appendix B), and they rently estimated at about 0.089–0.139 $/kWh [42–44].
remain unchanged every year throughout the lifetime of the pro-
ject. Accordingly, the levelized time-averaged fixed operating costs
LCOE ¼ LCOH=X e þ LIC e þ U c LIC c =X e ð46Þ
of HECA’s subsystems are listed in Table 4. To calculate HECA’s unit profit-margin, we use the profitability met-
The variable cost for the hydrogen subsystem incorporates the rics from Section 4, with a few updates. Starting with the static
costs of coal and petcoke as fuel, SelexolTM, flux, catalysts, other mode of operation, PM0f , PM 0e , and PM 1 are updated in accordance
chemicals, waste-water treatment, and the unit’s auxiliary load. with (38) in Section 5.1 to account for the CCS subsystem. With
For all other subsystems, the auxiliary loads are assumed to be PM0f ¼ 1:934 $/kgh, HECA is obviously profitable if run as a static
the only variable costs. The prices of all physical commodities are fertilizer-only plant. However, the facility would not break even if
fixed with time, assuming they are purchased through long-term
contracts (refer to Appendix B). However, we assume that HECA’s
net power output is sold in the wholesale market, and the cost of Table 7
auxiliary power equals the price of sold power. Hence, the yearly Economic valuation of HECA.
costs of the auxiliary loads in Table 2 are obtained by summing Economic metric Value Unit
up the hourly costs, which are calculated using variable electricity
LCOH 1.373 $/kgh
prices. To simulate a real-life performance, we use the 2012 whole-
LCOE 0.0953 $/kWh
sale one-day-ahead electricity prices from the SP26 pricing hub, Ue 0.000354 $/kgh
which covers the Southern California region where HECA plans to Uf 0.0105 $/kgh
operate [29]. The yearly price data, plotted in Fig. 3, is assumed ICMF f 1.196 $/kgh
to be replicated every year throughout the facility’s lifetime. Under ICMF e 2.223 $/kgh
PM0f 1.934 $/kgh
these assumptions, the time-averaged variable cost equals the
PM0e 0.992 $/kgh
yearly-averaged variable cost for each subsystem, and those costs PM1 ðfor k ¼ kmax Þ 0.163 $/kgh
are presented in Table 5. Finally, important to note, the variable PM2f ¼ PM2e 0.0439 $/kgh
cost of ammonia storage is assumed to be negligible, resulting in VODf ðfor k ¼ kmax Þ 2.097 $/kgh
was ¼ wa . VODe ðfor k ¼ kmax Þ 0.829 $/kgh
The last important set of economic data is the prices of end- VOF ðfor k ¼ kmax Þ 0.119 $/kgh
VOP f 1.978 $/kgh
products, which account for HECA’s revenues. The revenues from
VOP e 0.948 $/kgh
both fertilizers, urea and UAN, are combined in P f ð$=kgurea Þ. This
868 K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870
run as a static power-only plant, with PM 0e ¼ 0:992 $/kgh. The 0.6 3500
profit-margin of the static polygeneration mode PM 1 is between VOPf
PM0f and PM0e ; the exact value of PM1 changes with the hydrogen 0.4 VOPe 3000
allocation fraction k, as illustrated in Fig. 4. Under assumed prices me
and costs, a static HECA breaks even around k ¼ 0:66. Confirming 2500
0.2
our argument in Section 4, the value of diversification is not always
VOP ($/kgh)
2000
me (hr)
positive. In this case, diversifying away from power monogenera-
tion increases profitability, evident by the positive VODe . 0
Conversely, diversifying away from fertilizer monogeneration 1500
severely reduces profitability, evident by the negative VODf . -0.2
1000
Ultimately, increasing electricity generation reduces both prof-
itability and the associated values of diversification, as illustrated -0.4 500
in Fig. 4.
Shifting to the flexible polygeneration mode, PM2e and PM2f are -0.6 0
updated per Sections 5.1 and 5.2 to account for the CCS subsystem 400 450 500 550 600
and the correction factors for the time-dependent variable costs, Relative change in Pe (%)
respectively. Ue and Uf in Table 7 correct for the fact that the vari-
able costs change on an hourly basis due to HECA subsystems’ need Fig. 5. Value of polygeneration for flexible HECA under optimal operations.
for auxiliary power. In addition, although m e e and m e f are exoge-
nously imposed rather than endogenously optimized through
(15) and (16), the incremental flexibility contribution margins
the negative VOF. Conversely, when k is large, the static mode of
ICMF e and ICMF f are calculated by following their definitions in
HECA is dominated by electricity generation, so adding flexibility
(19) and (20). Referring to Table 7, ICMF f is clearly positive because leads to switching from low-price electricity to high-price fertiliz-
the contribution margin from fertilizers exceeds that from electric- ers during m e f . In this case, flexibility is useful, and PM2 is higher
ity during m e f hours. However, ICMF e is negative, contrary to our
than PM1 , evident by the positive VOF.
assertion in Section 3.2 that it should also be positive. Caused by Ultimately, VOF converges to VOP at either extreme value of k.
the exogeneity of m e e and me f , this result essentially means that When k ¼ 0, VOF is at its minimum value and equal to VOPf . Con-
urea and UAN generate higher revenue than electricity even during versely, when k ¼ 1, VOF is at its maximum value and equal to
me e hours when electricity prices are highest. Therefore, flexible VOPe . We conclude that HECA benefits from flexible polygeneration
power generation may seem like a poor line of business. if the company’s other feasible alternative is investing in a static
However, flexibility enables a two-way substitution, so a flexi- power-only plant, but it does not benefit from flexible polygener-
ble electricity capacity requires an equivalent flexible fertilizer ation if the other feasible alternative is investing in a static
capacity. For HECA, while a flexible power capacity may not be fertilizer-only plant.
beneficial because electricity prices are relatively low, flexible fer- For completeness, we briefly analyze HECA’s performance under
tilizer capacity is indeed beneficial for the exact same reason. This a hypothetical optimal operational schedule, where m e e and m
e f are
is better understood by looking at PM2 and the corresponding VOF. obtained endogenously. Under assumed prices and costs, we find
The profit-margin of a flexible HECA is PM2e ¼ PM2f ¼ 0:0439 that me ¼ 0 and mf ¼ m, suggesting – as expected – that the facility
$/kgh, so the facility almost breaks even. As shown in Fig. 4, a flex- should run as a static fertilizer-only plant. Increasing electricity
ible HECA can be less or more profitable than a static HECA, prices, nonetheless, leads to a different conclusion, as illustrated in
depending on the exact value of k for the latter. For a small k, the Fig. 5. First, we proportionally increase all prices of electricity
static HECA is dominated by fertilizer generation, so adding flexi- depicted in Fig. 3, which increases the average price Pe while pre-
bility leads to switching from high-price fertilizers to low-price serving the relative volatility. As electricity prices increase, me
electricity during the exogenously imposed m e e . In this case, increases, signifying the economic favorability of installing flexible
flexibility is not useful, and PM2 is lower than PM1 , evident by capacity and switching to electricity generation. When P e is 550–
574% times its current value, both VOP e and VOP f are positive; in this
case, flexible polygeneration becomes the most profitable alterna-
tive for HECA, better than all static polygeneration or monogenera-
3 PR1 VODe tion alternatives.
PR2 VODf
2 VOF 6.2.3. Sensitivity analysis
Since HECA is a first-of-a-kind facility, it seems particularly
Economic value ($/kgh)
0.4
profit-margin PM1 is between PM0f and PM0e , with the exact value
0 dependent on the exact splitting of produced hydrogen between
-0.4 the two end-products. As a flexible PES, HECA almost succeeds to
break even, with PM2 ¼ 0:0439 $/kgh. In this case study, the flex-
-0.8
ible polygeneration is unequivocally superior to all other operation
-1.2 modes only if electricity prices increase 5.5–5.74 folds under an
endogenously optimized operational schedule.
-1.6
Moving forward, several opportunities still exist to expand this
-2 work. One potential area of research involves analyzing the
-100% -75% -50% -25% 0% 25% 50% 75% 100%
economic value of polygeneration systems powered by renewable
Relative change in input (%) energy. While producing the same end-products (e.g. electricity
Fig. 6. Sensitivity analysis on the profitability of flexible HECA.
and fertilizer), renewable polygeneration might differ from fossil-
fuel polygeneration in two major ways, namely, hydrogen produc-
tion and the need for CCS. Multiple technologies are available to
produce hydrogen in renewable polygeneration, including biomass
7. Conclusions
gasification and water electrolysis powered by solar PV and wind
turbines. Interestingly, in this case, a separate source of carbon
The levelized cost of electricity is an important economic con-
would be needed to synthesize chemicals, and renewable PES
cept that can be expanded to assess the economic value of
may result in negative emissions if combined with CCS. In addition,
hydrogen-based polygeneration energy systems (PES). In this
hydrogen can be treated as a form of energy-storage if used to
study, we derive a set of metrics that quantify the cost, profitabil-
regenerate electricity.
ity, and real options associated with fossil-fuel PES. Because a PES
Furthermore, it would be rather important to examine the effect
can be divided into a distinct set of operational subsystems, we
of taxes, including tax subsidies, on polygeneration. Such endeavor
first define the levelized cost of hydrogen ðLCOHÞ and the levelized
requires a more careful analysis of investment tax credits, effective
incremental cost ðLIC Þ of converting hydrogen to market commodi-
corporate income tax rates, and accelerated depreciation rates that
ties such as electricity and fertilizers. All cost figures can be com-
could be applicable to both fossil-fuel and renewable polygenera-
bined into one term, the levelized cost of polygeneration ðLCOP Þ,
tion. Finally, this work assumes deterministic prices of commodity
expressed as a monetary value per unit of produced hydrogen
inputs and outputs as well as known energy policies. A more real-
($/kgh). Given that polygeneration systems share hydrogen as an
istic approach is to consider uncertain market prices then optimize
intermediate product, this approach allows a systematic compar-
the operational schedule of PES as prices vary with time. A similar
ison of polygeneration costs under multiple technical configura-
approach can be followed to incorporate uncertain environmental
tions and operation modes.
regulations in the form of future carbon pricing.
By adding end-products’ sales, we derive the optimal unit
profit-margin of PES under two operation modes: static production
Acknowledgements
of electricity and fertilizer ðPM1 Þ, and flexible production of elec-
tricity and fertilizer ðPM2 Þ. We then compare both metrics to the
The authors thank the Steyer-Taylor Center for Energy Policy
unit profit-margin of static monogenration of electricity or fertil-
and Finance and the TomKat Center for Sustainable Energy at
izer ðPM0 Þ. The difference between PM1 and PM0 is coined as the
Stanford University for funding this work. The authors also thank
value of diversification ðVODÞ, and it captures the economic
Professor John Weyant from the Department of Management
trade-offs associated with allocating hydrogen to multiple end-
Science and Engineering at Stanford University for his insightful
product units. Similarly, the difference between PM2 and PM1 is
reviews and comments. In addition, while the authors are solely
coined as the value of flexibility ðVOF Þ, and it captures the
responsible for the claims and findings from the HECA case study,
economic trade-offs associated with varying hydrogen allocation
we thank CEO Jim Croyle and Project Developer Stefanie Korepin
to each end-product unit over time. VOF and VOD can be combined
from Hydrogen Energy California for the helpful discussions and
into one term, referred to as the value of polygeneration ðVOPÞ.
for providing select data.
Also, we demonstrate how to update these metrics to assess PES
with carbon capture and storage (CCS).
Through a series of derived economic propositions, we show Appendices A and B. Supplementary data
that static polygeneration is more profitable than static monogen-
eration if VOD is positive. Similarly, flexible polygeneration is more Supplementary data associated with this article can be found, in
profitable than static polygeneration if VOF is positive, and flexible the online version, at http://dx.doi.org/10.1016/j.apenergy.2015.
polygeneration is more profitable than static monognerration if 12.008.
VOP is positive. Notably, however, VOD, VOF, and VOP need not
always be positive because of the aforementioned economic References
trade-offs. As such, no specific operation mode is unconditionally
[1] BP. BP statistical review of world energy; June 2014. <http://www.bp.com/
superior; the relative competitiveness of static monogeneration, en/global/corporate/about-bp/energy-economics/statistical-review-of-world-
static polygeneration, and flexible polygeneration is highly depen- energy.html>.
dent on the assumed commodity prices and investment costs. [2] IEA. 2014 Key world energy statistics; 2014. <http://www.iea.org/
publications/freepublications/publication/KeyWorld2014.pdf>.
Applying the aforementioned economic metrics to a real [3] Serra LM, Lozano M-A, Ramos J, Ensinas AV, Nebra SA. Polygeneration and
polygeneration project, Hydrogen Energy California, reveals their efficient use of natural resources. Energy 2009;34:575–86.
870 K. Farhat, S. Reichelstein / Applied Energy 164 (2016) 857–870
[4] Nexant. Polygeneration from coal: integrated power, chemicals, and liquid [25] Reichelstein S, Rohlfing-Bastian A. Levelized product cost: concept and
fuels, nexant chem systems, white plains, New York; 2008. decision relevance. Account Rev 2015;90(4).
[5] Meerman J, Ramírez A, Turkenburg W, Faaij A. Performance of simulated [26] Lerdal M. Hydrogen energy California, low-carbon solutions for California,
flexible integrated gasification polygeneration facilities. Part A: A technical- energy seminar. Stanford University, Stanford, California; 2012.
energetic assessment. Renew Sustain Energy Rev 2011;15:2563–87. [27] GE Energy. Heavy duty gas turbine products; 2009. <http://www.ge-
[6] Liu P, Pistikopoulos EN, Li Z. A multi-objective optimization approach to energy.com/content/multimedia/_files/downloads/GEH12985H.pdf>
polygeneration energy systems design. AIChE J: Process Syst Eng 2010;56(5). [Accessed 2014].
[7] Chen Y, Adams II TA, Barton a PI. Optimal design and operation of flexible [28] Wick J. Advanced gas turbine technology GT26. Alstom, Jornada Tecnológica in
energy polygeneration systems. Ind Eng Chem Res 2011;50:4553–66. Madrid, Madrid; 2006.
[8] Meerman J, Ramirez A, Turkenburg W, Faaij A. Performance of simulated [29] CAISO. Open access same-time information system (OASIS); 2012. <http://
flexible integrated gasification polygeneration facilities, Part B: Economic oasis.caiso.com>.
valuation. Renew Sustain Energy Rev 2012;16:6083–102. [30] IndexMundi. Urea monthly price – US dollars per metric ton; 2015. <http://
[9] H2Stations. Hydrogen filling stations worldwide; 2015. <http://www. www.indexmundi.com/commodities/?commodity=urea&months=120>
netinform.net/H2/H2Stations/H2Stations.aspx?Continent=AF&StationID=-1>. [Accessed 2015].
[10] Baker DR. Hydrogen-fueled cars face uncertain market in California; 2014. [31] HECA. The project; 2010. <http://hydrogenenergycalifornia.com/the-project>
<http://www.sfgate.com/news/article/Hydrogen-fueled-cars-face-uncertain- [Accessed 2014].
market-in-5519890.php> [Accessed 2015]. [32] HECA. Project fact sheet; 2010. <http://hydrogenenergycalifornia.com/
[11] Bromaghim G, Gibeault K, Serfass J, Serfass P, Wagner E. Hydrogen and fuel factsheets> [Accessed 2013].
cells: the US market report. National Hydrogen Association, Washington DC, [33] URS. Responses to CEC workshop requests: nos. a1 through a32. Amended
USA; 2010. application for certification HYDROGEN ENERGY CALIFORNIA (08-AFC-8A).
[12] Calise F, Cipollina A, d’Accadia MD, Piacentino A. A novel renewable Kern County, California, California Energy Commission, Sacramento,
polygeneration system for a small Mediterranean volcanic island for the California; 2012.
combined production of energy and water: dynamic simulation and economic [34] CEC. Hydrogen energy California project. Preliminary staff assessment, draft
assessment. Appl Energy 2014;135:675–93. environmental impact statement, US Department of Energy and California
[13] Rubio-Maya C, Uche-Marcuello J, Martínez-Gracia A, Bayod-Rújula AA. Design Energy Commission, Sacramento, California; 2013.
optimization of a polygeneration plant fuelled by natural gas and renewable [35] URS. Responses to sierra club data requests set three: nos. 132 through 146.
energy sources. Appl Energy 2011;88:449–57. Amended application for certification for HYDROGEN ENERGY CALIFORNIA
[14] Pellegrini LA, Soave G, Gamba S, Langè S. Economic analysis of a combined (08-AFC-8A). Kern County, California, California Energy Commission; 2013.
energy–methanol production plant. Appl Energy 2011;88:4891–7. [36] IEA GHG. Co-production of hydrogen and electricity by coal gasification with
[15] Li S, Gao L, Zhang X, Lin H, Jin H. Evaluation of cost reduction potential for a CO2 capture – updated economic analysis. International energy agency
coal based polygeneration system with CO2 capture. Energy 2012;45:101–6. greenhouse gas R&D programme; 2008.
[16] Hu L, Hongguang J, Lin G, Wei H. Techno-economic evaluation of coal-based [37] Bartels JR. A feasibility study of implementing an ammonia economy. Iowa
polygeneration systems of synthetic. Energy Convers Management 2011;52: State University, Ames, Iowa; 2008.
274–83. [38] Leighty B. Energy storage with anhydrous ammonia: comparison with other
[17] Narvaez A, Chadwick D, Kershenbaum L. Small-medium scale polygeneration energy storage. In: Ammonia: the key to US energy independence.
systems: methanol and power production. Appl Energy 2014;113:1109–17. Minneapolis; 2008.
[18] Ng KS, Zhang N, Sadhukhan J. Techno-economic analysis of polygeneration [39] Morgan ER. Techno-economic feasibility study of ammonia plants powered by
systems with carbon capture and storage and CO2 reuse. Chem Eng J offshore wind. University of Massachusetts – Amherst; 2013.
2013;219:96–108. [40] Lennon D. Refurbishing used plants. Relocating nitrogenous fertilizer plants,
[19] Cormos C-C. Assessment of flexible energy vectors poly-generation based on capital plant international.
coal and biomass/solid wastes co-gasification with carbon capture. Int J [41] Damas C. Terra nitrogen or CVR partners: fertilizer production capability; 21
Hydrogen Energy 2013:7855–66. October 2011. <http://seekingalpha.com/article/301165-terra-nitrogen-or-
[20] Liu P, Gerogiorgis DI, Pistikopoulos EN. Modeling and optimization of cvr-partners-fertilizer-production-capability>.
polygeneration energy systems. Catal Today 2007;127:347–59. [42] Rubin E, Booras G, Davison J, Ekstrom C, Matuszewski M, McCoy S, et al.
[21] Ramsden T, Ruth M, Diakov V, Laffen M, Timbario T. Hydrogen pathways: Toward a common method for cost estimation for CO2 capture and storage at
updated cost, well-to-wheels energy use, and emissions for the current fossil fuel power plants. Global CCS Institute; 2013.
technology status of ten hydrogen production, delivery, and distribution [43] Borenstein S. The private and public economics of renewable electricity
scenarios. National Renewable Energy Laboratory, Golden, Colorado, USA; 2013. generation. J Econ Perspect 2012:67–92.
[22] Ramsden T, Steward D, Zuboy J. Analyzing the levelized cost of centralized and [44] Abellera C, Short C. The costs of CCS and other low-carbon technologies. Global
distributed hydrogen production using the H2A production model, version 2. CCS Institute; 2011.
National Renewable Energy Laboratory, Golden, Colorado, USA; 2009. [45] Reichelstein S, Sahoo A. Time of day pricing and the levelized cost of
[23] MIT. The future of coal. Massachusetts Institute of Technology, Boston; 2007. intermittent power generation. Energy Econom 2015;48:97–108.
[24] Reichelstein S, Yorston M. The prospects for cost competitive solar PV power. [46] Marsden JE. Elementary classical analysis. San Francisco: W.H. Freeman and
Energy Policy 2012;55:117–27. Co.; 1974.