Torsion on Open Section Beams

and Pipe Supports Design


In the last twenty years, with the increased use of 3D modelling in the O&G
industry, most of the EPC companies have progressively passed the pipe
supports selection and design duties from Stress Engineers and Pipe Supports
Specialists to Piping Designers, who are directly involved in the 3D
modelling. This handover has generally not been supported by a structured
knowledge transfer, which has resulted in some recurrent examples of non-
optimal design. This paper addresses one of them, specifically the effect of
torsion induced on open shape beams, the implications of which are generally
little known by the wider audience, by presenting the engineering problem,
proposing the appropriate solutions for some typical cases and discussing
some experimental results, in an effort to raise the overall awareness on the
matter.

Introduction:
The present article is divided into three parts:

 Part A contains a simple mathematical dissertation on open shape beams


subject to torsion
 Part B lists some of the typical torsion related issues in the pipe support
design for the O&G industry. A solution to contain the effects of torsion is
given for each case.
 Part C recounts about the findings of an experiment done at site.

General:
Steel beams have evolved across last centuries to respond to the changing
needs of societies and technology; it has to be recognized that beams shapes
have been developed by Mankind (not readily available as such in Nature) to
resist specific type of loading and thus may not work properly when subjected
to kind of loading different from the ones they have been engineered for.
Among the above ones, two of the most recurrent shapes, utilised in various
Industries, for various scopes, are the circular hollow shape (pipe) and the H
shape (HEA and UC beams in example), see Fig. 1.

This article will mainly focus on these shapes for illustrative purposes around
the subject.

Fig. 1

PART A – Open shape steel beams


under torsion
Torsion on beams: Twisting.
The change of rotation (twist) per unit length (i.e. the first derivative of
rotation) of a St Venant beam subject to torsion (pure torsion of a long prism
unrestrained at its ends) is given by the following formula:

ɸ’ = T/G IT , where
T is the applied torque

G is the shear modulus

IT is the St Venant torsional constant


The rotation ɸ of one end of the prism with respect to the other end is thus
LT/G IT, where L is the length of the prism.
Fig. 2
Torsion on beams: Warping.
Warping happens when the sections of the prism are unable to keep flat during
deformation (i.e. deformation of the section happens also in the X direction in
Fig. 1 under loading). Warping depends on the shape geometry, round shapes
do not develop warping during twisting while open shapes (all commercial
profiles) generally develop some degree of warping, with the most significant
effects being shown by H types profiles. If warping deformation is prevented
by constraints (like i.e. welded or flanged connection at one end of the prism)
then stresses arise which may be significant and need to be accounted for in
the design. For the purpose of this sheet it is important to note that warping
involves the development of deformations not symmetrical with respect to the
loading (i.e. a support may not just twist but may develop movements in
directions not coherent with the load direction).

A Simple Calculation
Note: this article focuses on the deformations experienced by open shapes
when subjected to torsion and is aimed to assisting the designer in the
selection of the best support arrangement to avoid the occurrence of torsion;
as such, given that torsion in pipe support design is regarded as something to
be eliminated rather than designed for, no mention of how to calculate
stresses has been deliberately made. However part B is entirely derived from
the SCI publication “Design of steel beams in torsion” 1: for a complete
dissertation on the subject the reader may refer to the above mentioned
publication or others included among the references. Let us consider now the
case of an inverted L post on which an axial stop is installed (see Fig. 3) and
calculate the rotation that occurs at member b as a result of twisting in
member a.
Fig. 3
Data:
Twisting length C of member a (from the intersection with member b CL to
the top connection of the inverted L post)= 1400 mm

Lever arm L (from CL of load F to intersection between member a and b,


measured along member b axis)= 700 mm

Force F (due to axial stop)= 1 kN

Shape designation (assumed same for member a and b) : UKC 152x152x23

Saint Venant torsional constant1: 4.63 cm4 = 4.63 x 10^-8 m4


Shear modulus (G)1 : 81 GPa = 81 GN/m2
Calculation:
Applied torque T: F x A = 10 kN x 0.7 m = 7000 Nm

ɸ’= T/G IT = 700 / (81000000000 x 0.0000000463) ≈ 0.19 Rad/m


Rotation (across the “a” member whole length C): 1.4 x 0.19 = 0.266 Rad =
0.266 x 360 / (2π) ≈ 15 ⁰

Horizontal movement at point of application of F load (along F axis) = 0.7 x


sin 15⁰ ≈ 0.181 m
As it can be seen the result makes the choice of an H shape structure for this
application totally unsuitable (the axial stop, often referred to as “fixed point”,
would move nearly 20 cm).

If we had made the “a” member out of a cylindrical hollow shape the results
would have been completely different as all the components of equation (1)
would have been exactly the same apart from IT which, for a pipe of a similar
size and linear weight (i.e. 139.7 x 6.3) would have been about 1180 cm4,
leading to a movement of just 0.7 mm (generally acceptable for an axial stop).
This doesn’t want to be an exhortation to use cylindrical hollow shapes in
support design, cause:

 They may often be rejected by Clients due to internal corrosion concerns


 They bring along the difficulty of shaping the contour of member b
however the above calculation shows how much more effective a closed
circular shape is in resisting torsion with respect to an open one.

Note: the result above substantiates the use of plates fully welded along the
“a” member so to turn the latter into a closed squared section (Fig. 4) and
reduce its twisting (practice also known as “boxing” a shape); despite not a
neat solution (high stresses may exist at the sharp edges where welding is
performed and need to be evaluated) this solution may constitute a low impact
highly effective last resort (addition vs modification) when loads are not
significant and there might not be another easy ways through (i.e. inverted L
post support already installed).

Fig. 4
Comparatively, from what has been explained in pictures and numbers within
part A of this sheet, it can be inferred that the solution, sometimes proposed,
of stiffening a support against torsion by simply adding the usual stiffening
plates meant to reinforce the structures against concentrated loads (Fig. 5) is
to be considered meaningless: member “a” will remain substantially
unstiffened and will continue to show the same behaviour already analysed
over the length C-t (being t the thickness of the stiffening plate); in other
words the only considerable stiffening effect is introduced in principle just
over a limited portion of the structure, comparable to the thickness of the
added plate.

Fig. 5
The addition of plates at location 1 offers no contribution whatsoever to
limiting the twisting of member “a”, being the plates placed symmetrically
and in line with the load.

PART B – Pipe support induced


torsion on beams: frequent examples
in the O&G industry and their correct
solution
This section discusses three typical examples of torsion occurrence at pipe
supports installations and proposes the most appropriate line of action:

Axial stop on cantilever from columns or L


post:
This is a frequent design often arising at fixed points locations on small bore
lines, with the case shown on Fig. 6a (cantilever on a column) being less
severe, in terms of induced displacements, with respect to the case shown in
Fig. 6b (L post, having a free end). However, as we saw in the previous
section, even very limited loads (i.e. 1 kN) can cause movements of a couple
of order of magnitude greater than the expected ones at a fixed point hence the
solutions on the left hand side of pictures 6 should only be used when the
loads are negligible (note: as a first approximation the case of the cantilever
can be studied as the mechanical parallel of the stiffness deriving from two L
posts). In all other cases, when the loads cannot deemed negligible (i.e.
inducing unacceptably large displacements), the solutions proposed on the
right hand side of pictures 6 shall be pursued.

Fig. 6a
Fig. 6b
Vertical support offset from main structure:
This is a relatively frequent case that arises when a line is supported outside a
platform and from the platform steel itself. The direction of the beams
supporting the grating may not protect against the torsional effects shown in
the left hand side part of picture 7a. Also in this case the vertical
displacements may be significant and a connection to an adjacent beam is
always recommended to turn the torsion into bending as much as possible (the
beam will still be subject to torsion but this will be significantly limited, in
terms of overall rotation at the cantilever, by the relative deflections allowed
by the two members interested by the loads shown by light blue arrows on the
right hand side picture of Fig. 7a).

Fig. 7a
A similar case often arises when small bore lines are routed around a building
perimeter and supported from the building cladding structure. Small bore lines
can normally only span a fraction of the distance between the building
columns, however, it has to be recognised that providing one (or more)
cantilever from an horizontal beam belonging to the cladding structure (see
Fig. 7b) will not offer an effective mean of support as, unlike where in
coincidence with the building columns, relatively large rotations will occur
meaning that a significant transfer of load will concern the cantilevers
installed in coincidence of the main columns and, likewise, that the
deflections at the mid span cantilevers will likely exceed the permissible ones.
Again, also in this case, as a minimum, a vertical connection to a parallel
member either above or below the one subject to torsion shall be considered
so to turn torsion into bending and limit the overall deflections (ref. to Fig.
7a).

Fig. 7b
Axial stop lugs engaging the top flange only of
a support beam:
This typical design issue refers to an axial stop, often referred to as a “fixed
point” or, improperly, as an “anchor”, where the axial movement of a pipe is
prevented by welding lugs to the underneath of the pipe support so to engage
the beam.
Fig. 8a
The case in subject has to be referred generally to large bore lines, normally
“stopped” against primary structural members, discharging relevant loads
(typically in the range of hundreds of kN). In this case the concern is not
primarily the displacement arising from the beam deformation but the beam
stresses, particularly at the beam connections, which may not be designed for
this kind of loading.

Fig 8a (right hand side) shows the solution that should be the first line of
action for limiting the occurrence of torsion in the structural member.
However this solution may not sometimes be practicable, either due to
geometry reasons (i.e. very deep H shapes that would challenge the strength of
the stop lugs, which size is normally to be contained within the standard
support length) or due to the magnitude of the loads; in all such cases
consideration should be given to decoupling the rest and stop function as
shown in Fig. 8b, in consultation with the relevant structural design function.

Fig. 8b
PART C – Experimental evidence
This part summarizes the findings from an experiment conducted at site,
aimed at demonstrating the unsuitability of an inverted L post as a mean to
protect sensitive equipment. The axial stop shown in Fig. 9 was meant to
protect one reactor feed pump; the pump nozzle verification was just satisfied
under the hypothesis of infinitely rigid restraint (i.e. L post not to move
appreciably under the stop load), which, as we will see, was far from being
satisfied by the inverted L post.

L post data (ref. Fig. 3,9): C = 1.4 m; L = 0.75 m; F = 500 Kg; Shape:
HEA140.

Note: Fig. 9 shows the stop lugs not in contact with the L post; this is because
the lugs are normally tack welded in the shop to the shoe in order not to get
lost in field. Final repositioning at site during erection had still to take place
at the time the experiment was conducted.

Fig. 9
The experimental set-up shown in Fig. 10 was put in place so to create a
horizontal pull of 125 Kg (approx.) and demonstrate that the support was not
suitable to withstand the half a ton load it was meant to withstand from the
pipe stress calculation.
Fig. 10

Fig. 11
Fig. 11 shows clearly that the 125 Kg load induced a so large displacement of
the structure that its movement was only eventually limited by the contact
with the stop lug. The stop didn’t move appreciably as it was already
tightened onto the process line which, in turn, was anchored to the pump
nozzle. In Fig. 12 it is possible to see that the horizontal displacement of the
inverted “L” post load application point was about 9.6 cm before that contact
with the axial stop was reached.

Fig. 12
Note 1: the fact that the travel of the inverted “L”post horizontal member was
eventually limited by the presence of the axial stop means that the actual total
displacement caused by the load is unknown (we only know that the
displacement would have been larger than 9.6 cm). This however was in line
with the purpose of the experiment and is in line with the aim of the current
paper: torsion on secondary structures where industrial pipe supports are
installed is generally to be prevented rather than considered in the design.
Note2: The clamped axial stop was considered as a fixed point in the
experiment as the line movement caused by the application of a 125 Kg load
would have only been in the range of few mm and the aim of the experiment
was just to show that the secondary structure was far from being able to take
a load 4 times larger than the experiment one without moving appreciably. As
such a flexible meter was laid on to the axial stop bottom plate so to track the
member movement. The result is shown in the picture 12.
Note 3: from Fig 11 it is possible to notice that the metallic rope was tied to
the inverted “L” post horizontal beam in a way that caused the load to be
transferred mainly though the top flange. Furthermore, because of the
presence of the axial stop itself the load was applied alongside the edge of the
pipe support. This was not intentional and was due to how the experimental
setup was erected. The reader is cautioned about these two misalignments
with respect to the actual loading that would have arisen from the axial stop
(i.e. no rotation of the horizontal member due to the lugs engaging both
flanges and load in line with the axial stop centre line), however the purpose
of the experiment was only to show that the stiffness of the support assembly
was not in line with the hypothesis made in the stress calculation.
Note 4: it shall be noted that the inverted goal post was welded at the top to
an HE200A beam, subject to torsion as well. The entire assembly stiffness
against a horizontal force was so low that a movement of few mm of the L post
lower part could be achieved just by pushing it with one finger.
The inverted “L” post was eventually reinforced by means of double bracing
and the pump entered operation safely. If the experiment hadn’t been carried
out the pump would have almost certainly failed in a short time (this kind of
issues cannot be captured during pump alignment).

Conclusion
The unsuitability of open shape members to resist torsional moments was
demonstrated through a simplified calculation (Part A) and the presentation of
experimental evidence (part C). The conclusion form this paper is that torsion
shall be “designed out” of industrial piping support assemblies; a series of
examples of how this can be achieved in typical situation was illustrated in
part B.