You are on page 1of 7
Kuis 3 ECS Tea points e penbook, workgroup StudentiD / Name (al group members) * 19618006/Muhemmad Syaugi Hanif 113618007/Muhammad Latif Nurahman 11361801 0/irsyad M Nuristama Tohart 113618020/Muhammad Hilmi 113618051/Farras Ezra C Y__1.ECSis needed during cruising because the outside air is * O ‘0 et O two dense O too humid © twolow pressure V_ 2.The temperature change when the altitude is increasing is * O e8celeiusrkm @ s5celeiusim O e8celciusr1000 te O -s5celeius/1000 V. 3.For pressurized cat under normal operating condition, * the cabin pressure alttude is not to exceed 8000 ft 1 the arerat tude is not to exceed 2000 ft the cabin pressuteis ot lower than 75.3 KPa 7) ‘the cabin pressure isnt lower than 57.3 kPa aia aia aa V_4.For pressurized cabin and certification for operation above 25,000 ft 4/4 is requested, ater any probable failure condition in the pressurization system,* O cabin pressure must be less than 7 kPa © cabin pressure attude must be less than 15,000 ft v © aircraft atte must be lower than 25,000 ft © cabin pressure altitude must be lower than 25,000 ft W_5.For pressurized cabin, after a fallure which leads to cabin aa decompression where the failure is extremely improbable, the cabin pressure altitude * ] will not be lower than 25,000 ft for more than 2 minutes il not be higher than 25,000 ft fr more than 2 minutes v il not be higher than 40,000 fr any duration v Zo inany attude is atowed VY 6:The required fresh air supplied to cabin is * 46 © 10% cubic per minute © 055 tb per second © 0551 perminute per person v CO 10fteubie per hour per person VW 7.The measure of ECS performance is ..* aa © Energy ratio v O cooing ratio O Power ratio O Temperature ratio v Oo Ss Oo0@0 ®©ooo s Oo@o q @oo O 8. These cooling systems can be found in aircraft, except ..* 48 Ram air cooling Water cooling v Fuel Cooling Vapour eycle cooling 9. Ram air cooling system removes heat in the * a8 ‘compressor turbine heat exchanger v water separator 10. Low Pressure Water Separation (LPWS) means the water separator is. 4/4 located * before compressor before heat exchanger before cooling turbine after cooling turbine v 11. High Pressure Water Separation (HPWS) means the water separator is 4/4 located * before compressor before heat exchanger before cooling turbine v after cooling turbine OoO@0°0 s oO@°0O s S OoO@o0°0 12, Simple Air Cycle Machine has no * a8 ‘compressor v ‘cooling turbine heat exchanger water separator 13. In Simple Air Cycle Machines a significant pressure drop occurs in the 4/4 ‘compressor ‘cooling turbine v heat exchanger water separator 14. In Simple Air Cycle Machines a significant temperature drop occurs in 4/4 the* ‘compressor turbine heat exchanger v water separator 15. Two Wheel Bootstrap ACM has two* aa ‘compressors ‘cooling turbines heat exchangers v water separators x S oo@o < oooogs oo@°o i << 16, Which statement is correct? * ova Cooling turbine drives compressor v Cooling turbine drives fan Compressor eves cooling turbine Compressor drives fan Fan drives cooling turbine 17.In the reheater, the air from the secondary heat-exchanger will be* 4/4 heated up cooled down v ‘evaporated condensed 18. In the condenser, the air from the reheater will be * 418 heated up cooled down v ‘evaporated ‘condensed 19. In Three Wheel BAC, water is extracted * aia after the cooling turbine after the condenser v before the reheater v after the reheater < ooo0oe8os8 Boooag~aa s < COO ®@ 20. A Four Wheel BAC has two * heat-exchangers compressors cooling turbines water separators reheaters condensers 21.An Electric Air Conditioning System has two * heat-exchangers ‘compressors cooling turbines water separators reheaters condensers electric motors, 22, These are the types of heat-exchanger, except * double flow counter flow cross flow cross-counter flow 44 4/4 S 4/4 K CO@O M COO © Ooos S a 23. A condensation will occur when * the humidity is below the saturation point the humidity is above the saturation point the temperatur is too high the pressure is too low 24. A condensation process will * heat up the environment cool down the environment increase the pressure Increase the humidity 25. Air variables calculation in the following component(s) must use Kelvin for the temperature * ‘compressor heat-exchanger reheater ‘condensor turbine 4/4 4/4 4/4

You might also like