Micro/Vickers Hardness (HV) Test Results

Submitter Date Submitted


Part Name f6 Part # 6 h
# of Samples Sample Descri.
Qual. UL 650.0 Qual. LL 5.0

Machine ID Meas. Standard


Sample Cyl./Sph. Diam. Force(g) 50
(mm)

Test Results
# Depth Y D1 D2 Hard. Conver. # Depth Y D1 D2 Hard. Conver.
µm µm µm µm HV µm µm µm µm HV

1 27.9 26.7 124.7 17 25.5 27.0 134.7

2 27.4 28.7 118.0 18 26.3 26.4 133.6

3 26.1 26.8 132.5 19 26.6 25.3 137.6

4 25.5 26.2 138.6 20 28.1 27.8 118.7

5 26.0 26.1 136.6 21 26.3 26.1 135.4

6 27.1 26.1 131.3 22 26.2 25.8 137.5

7 27.4 26.9 126.1 23 26.0 25.9 137.7

8 28.1 27.2 121.3 24 27.4 27.5 123.4

9 26.1 26.2 135.4 25 26.4 26.6 132.4

10 26.2 25.5 139.1 26 27.1 24.9 137.7

11 26.8 26.1 132.9 27 26.6 26.9 130.0

12 27.0 25.2 136.1 28 26.6 25.8 135.1

13 26.8 24.8 139.4 29 26.9 25.8 133.7

14 27.2 25.0 136.3 30 28.2 27.3 120.5

15 26.6 26.4 132.1

16 26.6 25.3 137.6

Case Hardness(HV) Case Depth(µm)


Indent Images

1. 2. 3. 4.

5. 6. 7. 8.

9. 10. 11. 12.

13. 14. 15. 16.

17. 18. 19. 20.


Statistics
Maximum 139.4 Minimum 118.0
Average 132.2 Std. Dev. 1.2
Cp 93.30 Cpk 36.80

Operator Test Date Auditor Audit date