Sample note 1

Graph 1

Specimen 1 to 2
Tensile stress [MPa]

400

300
Specimen #
200
1
100 2

0
0 1 2 3 4 5 6

Tensile extension [mm]

Results table 1
Modulus Tensile stress Tensile stress
(Automatic at Yield (Offset at Tensile
Specimen text input 1
Young's) 0.2 %) strength
[GPa] [MPa] [MPa]
1 f1-1-afed ----- ----- 0.00
2 65.47 238.36 307.02
Maximum 65.47 238.36 307.02
Minimum 65.47 238.36 0.00
Mean 65.47 238.36 153.51
Standard
----- ----- 217.09
deviation

Tensile strain
(Strain
Tensile strain (Strain
25mm
25mm 100%) at Tensile
100%) at Specimen note 1
strength
Yield (Offset
[mm/mm]
0.2 %)
[%]
1 0.000 -----
2 0.196 0.564
Maximum 0.196 0.564
Minimum 0.000 0.564
Mean 0.098 0.564
Standard
0.14 -----
deviation

Test method
General: Test Type Tension method
Results Table 1: Column 1 Specimen text input 1
Results Table 1: Column 2 Modulus (Automatic Young's)
Results Table 1: Column 3 Tensile stress at Yield (Offset 0.2 %)
Results Table 1: Column 4 Tensile stress at Tensile strength
Results Table 1: Column 5 Tensile strain (Strain 25mm 100%) at Tensile
strength
Results Table 1: Column 6 Tensile strain (Strain 25mm 100%) at Yield (Offset
0.2 %)
Results Table 1: Column 7 Specimen note 1
Results Table 1: Statistic 1 Maximum
Results Table 1: Statistic 2 Minimum
Results Table 1: Statistic 3 Mean
Results Table 1: Statistic 4 Standard deviation

Page 1 of 3
2/14/2020 4:34:59 AM

Test prompts: Run as a prompted test False


Test Inputs: Test input 1 Specimen text input 1
Test Inputs: Test input 2 Width
Test Inputs: Test input 3 Thickness
Test Inputs: Test input 4 Specimen note 1
Data: Data capture scheme Custom settings
Data: Measurement 1 Time
Data: Interval 1 0.20000 s
Data: Criteria 1 True
Data: Measurement 2 Load
Data: Interval 2 50.00000 N
Data: Criteria 2 False
Data: Measurement 3 Tensile strain (Strain 25mm 100%)
Data: Interval 3 0.10000 %
Data: Criteria 3 False
End of test: Criteria 1 Rate of Load
End of test: Value 100.00000 N
End of test: Value 70.00000 %
End of test: End of test action Stop
End of test: Enable specimen protect False
End of test: Release pneumatic grips False
Export raw data: Export raw data True
Export results: Export results True
Export results: Content Results and Statistics
File Settings: Location E:\Public\Instron\Bluehill3\Output\M. Ahmed
File Settings: Sample file name test-as welded
File Settings: Automatically name the sample True
File Settings: Specify a default file name and location True
File Settings: Do not save the sample file at finish False
Frame: Threshold 500.00000 N
Frame: Override the default rate of return False
General: Method description
General: User tech
General: Unique identifier of sample {ECE8C52C-455B-49EE-9F85-431920D59D8A}
General: Method author tech
General: Test type Tension
General: Method name E:\Public\Instron\Bluehill3\Templates\Instron
Examples\Bluehill\mohamed Ahmed-tensile-
02.11.im_tens
General: Sample name E:\Public\Instron\Bluehill3\Output\M. Ahmed\test-as
welded_1.is_tens
General: System ID 8801Q2186
General: Number of specimens in sample 10
General: System of units SI
General: Assign specimen parameters from Method default
General: Run as a prompted test False
General: Last test date Friday, February 14, 2020
General: Last test time 4:32:46 AM
General: Method saved date 2/13/2020 07:22
Grips: Enable pretension False
Grips: Enable excess tension False
Load: Transducer configuration Load
Reports: Template E:\Public\Instron\Bluehill3\Templates\Anil.i_rt
Reports: Report format PDF
Reports: Save the report True
Reports: Print the report False
Reports: Email the report False
Reports: Print graph 1 False
Reports: Print graph 2 False
Sample notes: Sample description
Sample notes: Sample note 1
Sample notes: Sample note 2
Sample notes: Sample note 3
Sample number inputs: Sample number input 1 0.00000

Page 2 of 3
2/14/2020 4:34:59 AM

Sample text inputs: Sample text input 1 4043-t7-1


Specimen choice input: Specimen choice input 1 <None>
Specimen choice input: Specimen choice input 2 <None>
Specimen choice input: Specimen choice input 3 <None>
Specimen choice input: Specimen choice input 4 <None>
Specimen choice input: Specimen choice input 5 <None>
Specimen choice input: Specimen choice input 6 <None>
Specimen choice input: Specimen choice input 7 <None>
Specimen choice input: Specimen choice input 8 <None>
Specimen choice input: Specimen choice input 9 <None>
Specimen choice input: Specimen choice input 10 <None>
Specimen notes: Specimen note 1
Specimen notes: Specimen note 2
Specimen notes: Specimen note 3
Specimen number inputs: Specimen number input 1 0.00000
Specimen properties: Specimen label filler no.7 try-1
Specimen properties: Width 12.50000 mm
Specimen properties: Thickness 2.00000 mm
Specimen properties: Length 25.00000 mm
Specimen properties: Final width 10.00000 mm
Specimen properties: Final thickness 1.00000 mm
Specimen properties: Final length 100.00000 mm
Specimen properties: Geometry Rectangular
Specimen text inputs: Specimen text input 1
Start Test: Start test By the Start button
Strain: Remove extensometer during test True
Tensile strain (Strain 25mm 100%): Primary source Strain 25mm 100%
Test: Control mode 1 Extension
Test: Rate 1 0.50000 mm/min
Strain 25mm 100%: Transducer configuration Strain 25mm 100%
Remove extensometer during test: Lock Tensile False
strain at removal
Strain: Removal criteria Measurement event
Strain: Measurement Strain 25mm 100%
Strain: Value 0.40000 %
Strain: Action during removal Continue test
Test: Changeover (1 to 2) At extensometer removal
Test: Rate 2 1.00000 mm/min
Test: Ramp 2 True
Test: Control mode 2 Extension
Preload: Control mode Extension
Preload: Rate 10.00000 mm/min
Preload: Changeover criteria Measurement event
Preload: Measurement Load
Preload: Value 0.00000 N
Preload: Preload False
Sample text inputs: Sample text input 2 filler no. 1
Sample text inputs: Sample text input 3 filler no. 2
Sample text inputs: Sample text input 4 filler no. 3
Sample text inputs: Sample text input 5 filler no. 4
Sample text inputs: Sample text input 6 filler no. 5
Sample text inputs: Sample text input 7 filler no. 6
Sample text inputs: Sample text input 8 filler no. 7
Sample text inputs: Sample text input 9 filler no.8
End of test: Sensitivity 40.00000 %