CONNECTION GUIDE

IV-H Series

Rockwell
Compact Logix
Contents
Chapter 1 Used products............................................. 2
Chapter 2 How to connect........................................... 2
Chapter 3 Settings for communication....................... 3
Chapter 4 Basic Setting [RSLinx]............................... 4
Chapter 5 Basic Setting [RSLogix]............................. 6

Chapter 1 Used products


Please prepare the following products

Contact probe Power IO cable Ethernet cable


Compactl Logix Ethernet cable / hub
IV-H Series OP-87440 (2m) OP-87457(2m)

1769-L32E is
used to create
this setting guide

Chapter 2 How to connect


OVERALL CONNECTION DIAGRAM

Connect the CompactLogix and the IV series as shown below.

IV-H Series Ethernet hub

Rockwell
Compact Logix
Ethernet cable
OP-87457

Signal Color
I/O cable
OP-87440 24V Brown
24VDV Power supply
0V Blue

2
Chapter 3 Settings for communication

Use the Ethernet cable OP-87457 to connect IV to Select “Advanced”  “ “Environmental”  “ “Field
1 your PC
4 Network”, and set the “Protocol” to “EtherNet/IP”

IV-H Series PC (IV-Navigator installed)

Ethernet Cable OP-87457

2 Start IV-Navigator

Double click the icon of IV-Navigator on your desktop.


5 Set the IP address of IV (“192.168.10.202”).

3 Select “Network Connection” and connect to IV-H

Please be sure that your PC’s IP address is fixed, and the IP


address of IV-H is initialized (“----”).
Please refer to the Users Manual for the way how to initialize
the IP address.

3
Chapter 4 Basic Setting [RSLinx]
This operation would be necessary only once. For the following sample, the IP address of the PLC is set to 192.168.10.200

Connect the PC installed with RSLinx and 1769-L32E Input the IP address of the PLC (192.168.10.200) to
1 with Ethernet cable
6 [Station 0], and then click [Add New].

2 Open [RSLinx Classic].

3 Select [Configure Driver].

7 Select [EtherNet/IP Driver], and then click [Add New].

4 Click [Ethernet devices], and click [Add New].

8 Click [OK].

5 Click [OK].

4
Chapter 4 Basic Setting [RSLinx]

9 Select [Windows Default], and then click [OK]. 12 IV would be recognized like below.

Right click [AB_ETH-1, Ethernet], and then select


10 [Configure Driver].

Input the IP address of IV (“192.168.10.202”) to


11 [Station 1], and click [Add New].

5
Chapter 5 Basic Setting [RSLogix]
Use [RS Logix 5000] and communicate cyclic with IV.

Right click [1769-L32E Ethernet Port LocalENB], and


1 Open [RSLogix 5000]. 4 then select [New Module].

2 Select [New] inside [File], and create a New Project.

Input a project name (“IV”) inside [Name], and click


3 [OK].

Input the IP address (“192.168.10.200”) inside [IP


5 Address], and click [OK].

6
Chapter 5 Basic Setting [RSLogix]

Register IV as an Ethernet/IP module. Input the module name (“IV”) to [Name], and input the
6 Right click [1769-L32E Ethernet Port LocalENB], and 8 IP address of IV (“192.168.10.202”) to [IP Address].
select [New Module]. Select [Data-INT(16bit)] at [Comm Format], and input
the following numbers to [Connection Parameters].

The setting for [Connection Parameters] depends on the


setting of [Comm Format]. If [SINT(8bit)] or [DINT(32bit)] is
selected, refer to below.

If [SINT(8bit)] is selected.

Select [ETHERNET-MODULE] inside


7 [Communications], and click [OK].

If [DINT(32bit)] is selected.

* When setting [Comm Format] and [Connection Parameters]


please confirm carefully the specification of your sensor.
If this is not set properly, it might not operate correctly.

7
Chapter 5 Basic Setting [RSLogix]

Select the connected PLC unit (“00, CompactLogix


9 Click [OK]. 11 Processor, IV_Sample”), and click [Go Online].

10 Select [Who Active] inside [Communications].

12 Click [Download].

8
Chapter 5 Basic Setting [RSLogix]

* If the switch on CompactLogix is set to [Run], the


[Download] button could not be clicked. 14 You can see the result of the judgment like below.
Please select [REM] or [PROG].

Please confirm that it is in [Run] mode. Double click


13 [Controller Tags], and display the [Monitor Tag].

Input Data

Output Data

9
SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.

GLOBAL NETWORK CONTACT YOUR NEAREST OFFICE FOR RELEASE STATUS

AUSTRIA CZECH REPUBLIC INDIA MALAYSIA ROMANIA TAIWAN


BELGIUM FRANCE INDONESIA MEXICO SINGAPORE THAILAND
BRAZIL GERMANY ITALY NETHERLANDS SLOVAKIA UK & IRELAND
CANADA HONG KONG JAPAN PHILIPPINES SLOVENIA USA
CHINA HUNGARY KOREA POLAND SWITZERLAND VIETNAM

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW11-1037
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies.
Copyright © 2017 KEYENCE CORPORATION. All rights reserved. IVHConnectionG-WW-TG-GB 1029-3 600N51