You are on page 1of 3

Document 1410133.1 https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-stat...

Copyright (c) 2022, Oracle. All rights reserved. Oracle Confidential.

How to replace a SPARC T4-1 or Netra T4-1 XFP, XAUI Card Optical Single
Port:ATR:1410133.1:0 (Doc ID 1410133.1)

APPLIES TO:

SPARC T4-1 - Version All Versions and later


Netra SPARC T4-1 Server - Version All Versions and later
Information in this document applies to any platform.

GOAL

PCIe/XAUI/XFP Card Replacement

******************************************************************************
To report errors or request improvements on this procedure, please put a comment on Doc ID: 1410133.1
******************************************************************************

SOLUTION

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED


No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes


TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: failed XFP, PCIe or XAUI Card

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

ESD Caution:

Circuit boards and drives contain electronic components that are extremely sensitive to static electricity. Ordinary
amounts of static electricity from clothing or the work environment can destroy the components located on
these boards. Do not touch the components along their connector edges.
Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis,
depending on what type of strap you use, with the adhesive end or the metal plug.
Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an
antistatic mat

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged
components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it
into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages
during shipping.

1 of 3 2/14/2022, 4:46 PM
Document 1410133.1 https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-stat...

Caution – This procedure involves handling circuit boards that are extremely sensitive to static electricity. Ensure that you
follow ESD preventative practices to avoid damaging the circuit boards.

WHAT ACTIONS ARE REQUIRED:

PCIe Card Configuration Reference: Use the following table to plan your PCIe/XAUI card configuration on SPARC T4-1
server:

http://docs.oracle.com/cd/E22985_01/html/E22986/z40019011307802.html#scrolltoc

Remove a XFP, PCIe or XAUI Card,

1. Perform the preliminary steps required for cold service procedures.

2. Extend the server to the maintenance position.

3. Remove the top cover.

4. Attach an antistatic wrist strap.

5. Disconnect any cables connected to the card.

Note – If the riser has cards installed in both slots, disconnect all cables connected to both cards.

Tip – Label the cables to ensure proper connection to the replacement card.

6. Remove the riser that contains the card to be removed.

7. With the riser placed on an antistatic surface, disengage the card from its connector and place it on an antistatic surface.

Note - The card is held in place by a retention clip, which you must rotate up before the card can be removed.

8. If you are not replacing the XFP, PCIe or XAUI card, install a filler panel in the slot.

Caution - To ensure proper system cooling and EMI shielding, you must use the appropriate PCIe filler panel for the
server.

Install a XFP, PCIe or XAUI Card,

1. Perform the preliminary steps required for cold service procedures.

2. Locate the proper PCIe/XAUI/XFP slot for the card you are replacing.

3. Remove the PCIe/XAUI/XFP riser.

4. If a PCIe filler panel is installed, remove it.

5. Install the XFP, PCIe or XAUI card into the riser.

Note - Before inserting the card, you must rotate the retention clip out of the way.

6. Rotate the retention clip downward and press it until it is securely in place after XFP, PCIe or XAUI card is installed.

7. Reinstall the XFP/PCIe/XAUI riser.

8. Connect any data cables required to the PCIe/XAUI/XFP card. Route data cables through the cable management arm.

OBTAIN CUSTOMER ACCEPTANCE

2 of 3 2/14/2022, 4:46 PM
Document 1410133.1 https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-stat...

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart the server, and check functionality.

PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/SPARC_T4_1/components.html

REFERENCE INFORMATION:
SPARC T4-1 Service Manual: http://docs.oracle.com/cd/E22985_01/index.html or Netra SPARC T4-1 Service Manual, p/n