g a s f i t t i n g s a n d a d a p t e r s
a l w a y s t h e re f o r l i f e
Critical Communication
Please note the following corrections to the Fittings & Adapters Catalog.
Page 5 – Body Adaptor, 1/4” NPT Male: Part number 6700-1411-804 should be
6700-1411-805
Page 6 – Nipple, 1/8” NPT Male: Part number 6700-1810-801 should be 6700-1810-
804
Page 8 – Components: Part number 6700-1401-500 should be 6700-0169-500
Page 10 – Two –Piece Swivel Outlet, Disposable (l)
o 6700-1921-800 should be 6700-0089-700
o 6700-1922-800 should be 6700-0089-701
o 6700-1923-800 should be 6700-0089-703
o 6700-1920-800 should be 6700-0089-702
Page 10 – Tapered Nipple Assembly (l), with hand-tight nut and 5”chain: 6700-1917-
800 is an ISO product that is not currently offered.
Page 14 – DV Body Adaptor, ¼” NPT Male: 6700-1461-800 should be 6700-1464-
800
Page 24 – 1/8”NPT Male: 6700-2654-806 should be 6700-0654-806
Page 28 – Hose Barb; 5/16” I.D. Hose Barb: 6700-1565-805 should be 6700-1569-
805
Page 37 – Leak Detection Fluid: 6700-1741-800 has been discontinued.
Page 41 - 90° Male NPT Barbed for ¼” I.D. Hose: Part number 221-0702-300
should be 0221-0702-301
I apologize for these errors and any inconvenience they may cause. These changes will be
made before the next print run.
Thank you,
Susan McDaniel
Product Manager
Producers of Ohmeda Suction and Oxygen Therapy Devices, Aeros® Instruments Portable Suction Machines and
Squire-Cogswell Medical Gas Pipeline Equipment, Medical and Industrial Vacuum Systems and Air Compressor Packages
Color-coding Explanation
Color-coding is used as a gas identifier worldwide for medical gas fittings and connections. The following color-coding chart shows the
USA color-coding standards on the left and the ISO color-coding standards on the right.
USA ISO
DISS Nuts.......................................................................................................................................................................... 4
DISS Body Adaptors......................................................................................................................................................... 5
DISS Nipples..................................................................................................................................................................... 6
DISS Nipples with O-rings................................................................................................................................................ 7
DISS 1240 Oxygen Nuts, Nipples and Components......................................................................................................... 8
DISS 1240 Oxygen Body Adaptors................................................................................................................................... 9
DISS 1240 Oxygen Adaptors and Connections................................................................................................................ 10
DISS 1240 Oxygen Female Adaptors................................................................................................................................ 11
DISS Hex Nut & Nipple Combinations.............................................................................................................................. 12
DISS Hand-tight Nut & Nipple Combinations................................................................................................................... 13
Demand Check Units........................................................................................................................................................ 14
One-Way Check Valves..................................................................................................................................................... 15
Power Take-Off Assemblies............................................................................................................................................. 16
Dual Outlet Y-Connections............................................................................................................................................... 17
Chemetron® Style Dual Outlet Connections.................................................................................................................... 18
Ohmeda® Style Dual Outlet Connections......................................................................................................................... 19
Chemetron® Style Male Quick-Connects......................................................................................................................... 20
Chemetron® Style Female Couplers................................................................................................................................. 21
Ohmeda® Style Male Quick-Connects............................................................................................................................. 22
Ohmeda® Style Female Couplers..................................................................................................................................... 23
Schrader® Non-Swivel Style Male Quick-Connects........................................................................................................ 24
Schrader® Swivel Style Male Quick-Connects................................................................................................................ 25
Schrader® Style Female Couplers and Dual Outlet Connections.................................................................................... 26
Puritan® Style Female Couplers and Dual Outlet Connections....................................................................................... 27
Puritan® Style Male Quick-Connects............................................................................................................................... 28
Oxygen Neb Drives........................................................................................................................................................... 29
Conductive Hose............................................................................................................................................................... 30
Non-Conductive Hose....................................................................................................................................................... 31
Hose Assembly Matrix...................................................................................................................................................... 32-33
End Connections............................................................................................................................................................... 34-35
Components for Hose Assemblies................................................................................................................................... 36
Medical Grade Vinyl Tubing.............................................................................................................................................. 37
Teflon® Tape..................................................................................................................................................................... 37
Leak Detection Fluid......................................................................................................................................................... 37
Water Trap Assemblies..................................................................................................................................................... 38
Compact Valves................................................................................................................................................................ 39
Pipe Thread to Barbed Hose Adaptors............................................................................................................................. 40-41
Pipe Thread Fittings......................................................................................................................................................... 42-43
Flexible Pigtails................................................................................................................................................................ 44
Oxygen Rigid Pigtail......................................................................................................................................................... 45
High-Pressure Fittings..................................................................................................................................................... 45
CGA Series Cylinder Valve Connections.......................................................................................................................... 46
Cylinder Wrenches............................................................................................................................................................ 47
Pin-Indexed Yoke Assemblies.......................................................................................................................................... 48-49
Diameter-Index Safety System Explanation.................................................................................................................... 50
Warranty and Remedy ..................................................................................................................................................... 51
C D
B
A Note: (I) Heliox mixtures: Helium over 80%.
Nut
(II) Heliox mixtures: Helium not over 80%.
Nipple
p tor (III) Intended for the powering of medical
Body Ada devices unrelated to human respiration.
Hex Nut - for use
with DISS Nipples
Retaining Ring
Carbon Dioxide, Instrument Air (III),
He-O2 mixture (I), WAGD (EVAC)............................................... 6700-1971-800
Medical Air,
Nitrogen,
Nitrous Oxide,
O2-He mixture (II),
Vacuum (Suction)........................................ 6700-1972-800
Diameter Index Safety System Hex Nut - for use Hand-tight Nut -
with DISS Nipples for use with DISS
DISS explanation on page 50 with O-rings Nipples with O-rings
C D
B
A Note: (I) Heliox mixtures: Helium over 80%.
Nut
(II) Heliox mixtures: Helium not over 80%.
Nipple
p tor (III) Intended for the powering of medical
Body Ada devices unrelated to human respiration.
6700-1835-802
O-ring Replacement
Carbon Dixide, DISS 1080-A......................... 6700-1405-500 Nitrous Oxide, DISS 1040-A......................... 6700-0170-500
He-O2 mixture (I), DISS 1060-A.................... 6700-1408-500 O2-He mixture (II), DISS 1180-A................... 6700-1406-500
Instrument Air (III), DISS 2080..................... 6700-1410-500 Vacuum (Suction), DISS 1220...................... 6700-0171-500
Medical Air, DISS 1160-A............................. 6700-0172-500 WAGD (EVAC), DISS 2220............................. 6700-0173-500
Nitrogen, DISS 1120-A.................................. 6700-0185-500
C D
A B
Nut
Nipple
p tor
Body Ada Note: (I) Not intended for static pressure build-up.
Hand-tight Nut
Oxygen, Green........................ 6700-1893-800
Oxygen, White (ISO)................ 6700-1894-800
Nipple, 1/8" NPT Male Nipple, 1/8" NPT Male with O-ring
1" Long.................................. 6700-1840-800 1" Long.................................. 6700-1841-800
1-1/2" Long............................ 6700-1842-800 1-1/2" Long............................ 6700-1843-800
C D
A B
Nut
Nipple Note: Demand Check Units and One-Way Check
p tor
Body Ada Valves, see pages 14 and 15
Body Adaptor, NPT Female with Filtered Orifice (Orifice Size Stamped on Body Adaptor)
1/8" NPT Male with #77 Orifice................... 6700-1407-801
1/4" NPT Male with #77 Orifice................... 6700-1407-800
C D
A B
Nut
Note: (I) Not intended for static pressure build-up.
Nipple
ptor (II) Provides a leak-tight seal rated at
Body Ada 200 psi gas service.
Tapered Nipple Assembly (I), with hex nut and 5" chain
..................................................................... 6700-1926-800
Tapered Nipple Assembly (I), with hand-tight nut and 5" chain
Green............................................................ 6700-1916-800
White (ISO)................................................... 6700-1917-800
C D
A B
Nut
Nipple
p tor
Body Ada
C D
A B
Nut Note: (I) Heliox mixtures: Helium over 80%.
Nipple (II) Heliox mixtures: Helium not over 80%.
p tor (III) Intended for the powering of medical
Body Ada devices unrelated to human respiration.
7/8"-14 Thread
WAGD (EVAC), DISS 2220............................. 6700-1933-805
C D
A B
Nut
Nipple
p tor
Body Ada
3/4"-16 Thread
Carbon Dioxide, DISS 1080-A...................... 6700-0510-804
Medical Air, DISS 1160-A............................. 6700-0510-803
Nitrogen, DISS 1120-A.................................. 6700-0510-806
Nitrous Oxide, DISS 1040-A......................... 6700-0510-801
Vacuum (suction), DISS 1220...................... 6700-0510-802
C D
A B
Nut
Nipple No Flow
ptor
Body Ada
Mechanism automatically shuts Unit opens when mating
off gas supply when disconnected connection is complete
3/4"-16 Thread
He-O2 mixture (I), DISS 1060-A.................... 6700-1461-800
Medical Air, DISS 1160-A............................. 6700-0069-700
Nitrogen, DISS 1120-A.................................. 6700-1463-806
DV Body Adaptor, Barbed for 1/4" I.D. Hose with Hand Grip Collar
9/16"-18 Thread Nitrogen, DISS 1120-A.................................. 6700-0519-806
Oxygen, DISS 1240....................................... 6700-0519-800 Vacuum (Suction), DISS 1220...................... 6700-0519-802
DV Body Adaptor, Barbed for 5/16" I.D. Hose with Hand Grip Collar
3/4"-16 Thread
Vacuum (Suction), DISS1220....................... 6700-1466-802
7/8"-14 Thread
WAGD (EVAC), DISS 2220............................. 6700-1471-805
C D
A B
Nut
Nipple No Flow
p tor Direction of Flow
Body Ada Gas Pressure Activated
Y-Blocks
1/8" NPT Female All Ports.............................. 6700-0224-500
1/8" NPT Female Inlet x 1/4" NPT Female Outlets...................
..................................................................... 6700-0211-500
1/4" NPT Female All Ports.............................. 6700-2006-801
3/4"-16 Thread
Medical Air, DISS 1160-A............................. 6700-2015-804
Nitrogen, DISS 1120-A.................................. 6700-2014-806
Nitrous Oxide, DISS 1040-A......................... 6700-2010-801
Vacuum (Suction), DISS 1220...................... 6700-2017-802
3/4"-16 Thread
Medical Air, DISS 1160-A............................. 0221-0467-803
Nitrogen, DISS 1120-A.................................. 6700-2013-806
Nitrous Oxide, DISS 1040-A......................... 6700-2009-801
Vacuum (Suction), DISS 1220...................... 0221-0467-802
3/4"-16 Thread
Medical Air, DISS 1160-A............................. 6700-2015-803
Nitrogen, DISS 1120-A.................................. 6700-2012-806
Nitrous Oxide, DISS 1040-A......................... 6700-2008-801
Vacuum (Suction), DISS 1220...................... 6700-2016-802
Black Cap
Nitrogen................................. 6700-1697-806
Hose Barb
1/4" I.D. Hose Barb
Medical Air............................. 6700-0651-807
Nitrous Oxide......................... 6700-1695-801
Oxygen................................... 6700-1698-800
Vacuum (Suction).................. 6700-1699-802
Black Cap
Nitrogen................................. 6700-1696-806
Black Caps
Nitrogen................................. 6700-2020-806
Hose Barb
1/4" I.D. Hose Barb
Medical Air............................. 6700-1683-803
Nitrous Oxide......................... 6700-1685-801
Oxygen................................... 6700-1687-800
Vacuum (Suction).................. 6700-1689-802
WAGD (EVAC)......................... 6700-1692-805
Chemetron® Style
6 - 7 lpm................................. 6700-1769-800
7 - 8 lpm................................. 6700-1770-800
Ohmeda® Style
6 - 7 lpm................................. 6700-1771-800
7 - 8 lpm................................. 6700-1772-800
Puritan® Style
6 - 7 lpm................................. 6700-1773-800
7 - 8 lpm................................. 6700-1774-800
Rubber Hose for Oxygen Service (Packaged 650 ft. per reel)
Used in applications where extreme temperatures may be present (i.e. Emergency Medical Service).
• Inner core: Synthetic Rubber 3/16" I.D. U.S. Gas Service.......... Color........................................ Item No.
• Braid-reinforced Outside Diameter: .415"
• Outer cover: Synthetic Rubber Oxygen......................... Green............................6700-1737-800
• Working pressure: 200 psi max.
• Minimum bend radius: 3 inches
• Burst Pressure: 1500 psi max.
• Working Temperature: -40° F to +200° F
Fill in ____ ____ ____ ____ ____ ____ ____ ____ ____
Then call Ohio Medical for verification as well as pricing and availability.
Save time and money! (suggestion: photocopy this worksheet for your future orders.)
Hose Type
X X
____ ____ ____ ____ ____ ____ ____ ____ ____
STEP 1
Type: Conductive PVC Non-Conductive PVC Rubber Hose
Internal Diameter: 1/4" 5/16" 1/4" 5/16" 3/16"
Hose Length
X X X
____ ____ ____ ____ ____ ____ ____ ____ ____
STEP 2
End Connections
X X X X
____ ____ ____ ____ ____ ____ ____ ____ ____
inlet outlet
STEP 3
• Find associated two-digit order number
• repeat for end connection #2
S
____ ____ ____ ____ ____ ____ ____ ____ ____ STEP 4
Add S prefix to part number. See pages 34 and 35 for available inlet connections.
(Swivel adaptor sold separately. See page 41 for details.)
S
hand-tight nut
DISS Female Nut & Nipple S
hex nut and nipple
with O-ring
DISS Female Nut & Nipple
Carbon Dioxide (grey) – 42 Carbon Dioxide – 45
Medical Air (yellow) – 62 He-O2 – 35
Nitrogen (black) – 52 Instrument Air – 18
Nitrous Oxide (blue) – 22 Medical Air – 65
Oxygen (green) – 82 Nitrogen – 55
Oxygen (white) – 88 Nitrous Oxide – 25
VAC/Suction (white) – 72 O2-He – 38
WAGD/EVAC (purple) – 02 Oxygen – 85
VAC/Suction – 75
WAGD/EVAC – 05
S
wing nut style
DISS Female Oxygen Nut & Nipple with hand
grip collar
DISS Male Body Adaptor
Oxygen (green) – 83 Carbon Dioxide (grey) – 40
Medical Air (yellow) – 60
Nitrogen (black) – 50
Nitrous Oxide (blue) – 20
Oxygen (green) – 80
VAC/Suction (white) – 70
WAGD/EVAC (purple) – 01
nipple opens valve DISS Male with Demand Check DISS Male Body Adaptor
Carbon Dioxide (grey) – 47 Air – 61
Medical Air (yellow) – 67 He-O2 – 31
Nitrogen (black) – 57 Instrument Air – 16
Nitrous Oxide (blue) – 27 O2-He – 36
Oxygen (green) – 87 Oxygen – 81
VAC/Suction (white) – 77
WAGD/EVAC (purple) – 07
S
swivel stem
Schrader® Style Male Adaptor Schrader® Style Female Coupler
Air – S6 Medical Air – F6
Nitrogen – SN Nitrogen – FN
Nitrous Oxide – S8 Nitrous Oxide – F8
Oxygen – S5 Oxygen – F5
VAC/Suction – 74 VAC/Suction – F7
S
non-swivel stem
Schrader® Style Male Adaptor
Air – S2
Nitrogen – S9
Nitrous Oxide – S4
Oxygen – S1
VAC/Suction – 73
= swivel style
S
available for inlet.
No End Connection
Blank End – 00
= swivel style
S
available for inlet.
Ferrules
I.D.........................Length.........................................Item No. .500".....................5/8"....................(I).......... 6700-0225-400
.330".....................1/2"................................. 6700-1712-400 .525".....................5/8"................................. 6700-0226-400
.358".....................1/2"................................. 6700-1713-400 .548".....................31/64"............................. 6700-1718-400
.380".....................1/2"................................. 6700-1714-400 .564".....................3/4"................................. 6700-1719-400
.410".....................1/2"................................. 6700-1715-400 .575".....................31/64"................(II)......... 6700-1720-400
.450".....................9/16"..................(III)......... 6700-1716-400
.478".....................11/16"............................. 6700-1717-400
Recommended Die Set for Ohio Medical 1/4" I.D. hose................................. 6700-1706-800
Recommended Die Set for Ohio Medical 5/16" I.D. hose.............................. 6700-1707-800
Recommended Die Set for Ohio Medical 3/16" I.D. hose............................... 6700-1705-800
Hose Retractor
Hose Retractor......................................................... 261 746
Helps prevent moisture and water from entering downstream equipment while filtering • Miniature Size
out foreign material and debris. Designed for a service pressure of 150 psi maximum. • 5-Micron Filter
• Manual Drain Valve
• High Flow Capacity
Straight Configurations
Medical Air, DISS 1160-A............................. 6700-2001-803
Male Inlet x Female Outlet
Oxygen, DISS 1240....................................... 6700-2002-800
Male Inlet x Female Outlet
Flow
90° Configurations
Medical Air, DISS 1160-A............................. 6700-2000-803
90° Male Inlet x Female Outlet
Flow
Flow
Flow
Featuring 1/4" turn shutoff for quick operation and visual on/off status. Full flow construction
for optimum performance. Durable, chrome-plated brass body. Non-corrosive service.
Flow
Flow
Hose Splicers
Barbed for joining 1/8" I.D. Hose.................... 6700-1977-800
Barbed for joining 3/16" I.D. Hose.................. 6700-1978-800
Barbed for joining 1/4" I.D. Hose.................... 6700-1976-800
Flexible assemblies contain a Teflon® inner core supported by a stainless steel wire braid
external wrap. End connections are stainless steel, unless otherwise indicated.
Temperature range: -40° to 150°F.
Flexible Stainless Steel Pigtails, 1/4" NPT Female x 1/4" NPT Female (I)
18" Long...................................................... 6700-1958-800
24" Long...................................................... 6700-1959-800
36" Long...................................................... 6700-1960-800
48" Long...................................................... 6700-1961-800
Insufflator Pigtail for Carbon Dioxide Service (For use in conjunction with Insufflator Yoke, #6700-2038-800, see pg. 49)
1/4" SAE Flare with 7/16" - 20 Thread,...... 6700-1984-800
Length - 36"
One-Way Check Valve, 1/4" NPT Female Inlet x 1/4" NPT Male Outlet
Adaptor with Nitrile O-ring.......................... 6700-1478-800
Adaptor with Viton O-ring........................... 6700-1479-800
for Oxygen service
Flow
Tee Couplers
Oxygen, Chrome-Plated Brass....................... 6700-1981-800
Oxygen, Unplated.......................................... 6700-1982-800
CGA Male
Insufflator Yoke
Oxygen; CGA 870 Helium, Helium & Oxygen Mixtures (II) CGA 930
CGA 540 Male......................... 6700-2029-800 1/4" NPT Male........................ 6700-2035-800
1/4" NPT Male........................ 6700-2027-800
1/4" NPT Male........................ 6700-2028-800
w/One-Way Check Valve and Carbon Dioxide,
Rubber Washer Carbon Dioxide & Oxygen Mixtures (VI); CGA 940
Carbon Dioxide & Oxygen Mixtures (I) CGA 880 1/4" NPT Male........................ 6700-2036-800
1/4" NPT Male........................ 6700-2037-800
w/One-Way Check Valve and
1/4" NPT Male......................................... 6700-2030-800
Rubber Washer
Insufflator Yoke, 7/16" Flare 6700-2038-800
Helium & Oxygen Mixtures (V)
Nitrogen & Oxygen Mixtures (III) Air; CGA 950
Xenon & Oxygen Mixtures (IV); CGA 890
CGA 346 Male......................... 6700-2041-800
1/4" NPT Male........................ 6700-2039-800
1/4" NPT Male........................................ 6700-2031-800 1/4" NPT Male........................ 6700-2040-800
w/One-Way Check Valve and
Rubber Washer
Nitrous Oxide; CGA 910
Nitrogen; CGA 960
CGA 326 Male.........................................6700-2034-800
1/4" NPT Male........................................6700-2032-800 CGA 580 Male......................... 6700-2043-800
1/4" NPT Male........................................6700-2033-800 1/4" NPT Male........................ 6700-2042-800
w/One-Way Check Valve and
Rubber Washer
Special Medical Mixtures; CGA 973*
1/4" NPT Male........................ 6700-2044-800
The compressed Gas Association (CGA) developed the Diameter-Index Safety System (DISS) to establish a standard for non-interchangeable, removable connections
for use with Medical Gases (200 psi max.), Vacuum (Suction), and WAGD (Evacuation) Service. Non-interchangeable indexing is achieved by a series of increasing
and decreasing diameters in the components of the connections. These specific diameters act in a key-like fashion, so that fittings within the gas service “family”
(Vacuum and WAGD included) will connect only with their own “family members.” In place of diameter indexing, Oxygen (DISS 1240) has been assigned the long
established 9/16"-18 thread connection as its safety standard.
Each DISS connection consists of a Body Adaptor, Nipple and Nut (Fig. 1). As the diameters of the Body Adaptor (A & B) increase/decrease, the diameters of its
mating Nipple (C & D) increase/decrease proportionally. In this way, only properly mated and intended parts fit together to permit thread engagement (Fig. 2)
The DISS system is utilized on gas pressure regulator outlets, wall outlets, anesthesia equipment and respiratory therapy equipment. Ohio Medical is an active
contributing CGA member. For additional information on the Diameter-Index Safety System, please contact Ohio Medical.
figure 1
D C
A B
Nut
Nipple
aptor
Body Ad
figure 2
Chemetron®, Ohmeda®, Puritan® and Schrader® are trademarks of their respective companies.
O H M E DA® S U C T I O N & O X Y G E N T H E R A P Y D E V I C E S
H E A L T H C A I R,® L A B C A I R ,® S E L E C T O R R ® S E R I E S O F
VACUUM & AIR COMPRESSOR PACKAGES AND ACCESSORIES
255392 1/07