You are on page 1of 6
\ Certificate Number C Issued 16 October 2015 BASSSATEX7060 aseefa Issue 19 _SGS- Page 1 of 6 1 EC - TYPE EXAMINATION CERTIFICATE 2 Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/BC 3° BC- Type Examination BAS99ATEX7060 ~ Issue 19 Certificate Number: 4 Equipment or Protective System: Smart Transmitter Isolator Type K*D2-STC(V)4-Ex1(.20)(.P) S Manufacturer: Pepperl + Fuchs GmbH. 6 Address: Lilienthalstrasse 200, 68307 Mannheim, Germany 7 ‘This re-issued certificate extends EC ~ Type Examination Certificate No. BAS99ATEX7060 to apply to equipment or proteotve systems designed and constructed in accordance with the specification set out in the Schedule of the said certificate but having any variations specified in the Schedule attached to this certificate and the documents therein refered to 8 The original cert which retains responsibility for its original document only for the additional work relating to this re-issued certificate and any other supplementary certificat issued. icate was issued by The Electrical Equipment Certification Service, Notified Body Number 0600, Baseefa, Notified Body Number 1180, is responsible has “The examination and test results are recorded in confidential Report No's. See Certificate History 9 Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-0:2012+A41:2013 EN 60079-11:2012 except in respect of those requirements listed at item 18 of the Schedule 10 If the sign “X" is placed after the certificate number, it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule to this certificate 11 This EC - TYPE EXAMINATION CERTIFICATE relates only to the design and construction of the specified equipment or protective system. Further requirements of the Directive apply to the manufacturing process and supply of this equipment or protective system, These are not covered by this certificate. 12. The marking of the equipment or protective system shall include the following @ WG [exiaGal nC 20°C eta <+60°C) ® UMD [exia al Mc (20°C < Ta = +60°C) Baseefa Customer Reference No. 0808 Project File No. 15/0759 “This document i isued by the Company eaboct fo Ws General Conditions for Cerfcation Services accesible at hi/onas sas comiaLemsand= ‘Conditionsaspx_and the Supplementary Terms and Condiions accesible at hw baseefcomvterms-and-condtions ap. Attention is drawn to the Timitation of liability, indemmiistion and jurisdiction issues defined therein. Any olde of his document s advised tha information comsned herein reflects the Company’ findings atthe time of is intervention only and within the limits of Cents instructions, i any, It does not necessary andcate that the ‘equipment may be used in particular industries or circumstances, The Company's sole responsibilty 19 ils Client and this dacument does not exonerate Patss 10a transition from exetising all their rights and obligations under the tasacton documents. This documest cannot be reproduced except in fll, Schedule included, without prot waiten approval ofthe Company. Any unauthorized alteration, forgery oF falsification ofthe coment or appearance ofthis ocument is unlawful and offenders maybe prosecuted tothe ulet exten ofthe aw SGS Baseefa Limited Rockhead Business Park, Staden Lane, we. cally, Buxton, Derbyshire SK17 9RZ 2 Telephone +44 (0) 1298 766800 Fax +44 (0) 1298 766601 RSSINCLAIR fP OWE Wee e-malinfo@baseeta.com web site ww. basseta.com GENERAL MANAGER Regwtered im Eneland No. 4305578 c Registrd ads: Rossmore Busnes Park, Elsmere Port, Cheshite, C165 3EN On behalf of SGS Baseefat Limited Certificate Number C Issued 16 October 2015 BAS99ATEX7060 Issue 19 Baseefa Page 2 of 6 3 Schedule 4 Certificate Number BAS99ATEX7060 — Issue 19 15 Description of Equipment or Protective System ‘The KFD2-STC(V)4-Ex1( 20). Smart Transmitter Isolator is a designed to provide gatvanic isolation between intrinsically safe circuits in a hazardous area and unspecified associated apparatus in a non-hazardous atea and limit the voltage and current into the hazardous area to intrinsically safe levels. The apparatus comprises a number of electrical components, including transformers, fuses, resistors and zener diodes, all ‘mounted on single printed circuit board and housed within a plastic enclosure fitted with terminals for external connections. ‘The use of'C’ or 'V" in the type description specifies Current source / sink or Voltage respectively. Options following "Ex!" in the type description are: 20 (Dual non-hazardous area output) -Y... (Current sink - used with 'C) <1 (5 Volt used with 'V) (20 Volt - used with 'V) ‘The apparatus is designed to operate from a dc. supply of up (0 35V on terminals 7 10 12, 14 and 15, and power rail connector terminals 1 and 2. The segregation of the hazardous area circuits meets the requirements for 2S0V. FOR VARIANTS TYPE KFD2-STC(V}4-EX1, AND TYPE KED2-STO(VM-EX1,20 For terminals 7 to 12, 14 and 15, and power rail terminals | & 2:= U,= 250V For Terminals Land 3:= Us=25AV [,=86.8mA P,=SSimW C,= 120F ‘The capacitance and either the inductance or the inductance 10 resistance ratio (L/R) of the hazardous area load must not exceed the following values: ‘GROUP, CAPACITANCE in uF | INDUCTANCE OR DIR RATIO in mit in pH/ ic ‘C098 56 25 1B. 0.798 18 243 HA 2.808 36 486 T 43 29 333 For Terminals 3 and 2 (& 5) Us"3SV [= 74mA P= 64mW = 30V = LISA Certificate Number S G S I 6 Oct BASASATEXTOGO Baseefa ssued 4 So tober 2015 ue The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazasdous area load must not exceed the follewing values: GROUP ‘CAPACITANCE in uF | _INDUCTANCE OR TUR RATIO in mt in HO iT 100 oa 532 1B. 100 25 532 HA 100 50 332 1 1000 a2 7207 For Terminals 1,2 (& 5) and Uj=254V [y= 1ISMA P,=0.584W C= 12M, =0 The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area load must not exceed the following values ‘GROUP CAPACITANCE in nF | INDUCTANCE OR UR RATIO. in mit in wH/ TiC ‘C095 27, @s 1B. 0.798 U1 243, HA 2.808 2 486 1 43 17 639 For Terminals 6 and 5 (&2):- U=8IV =o C=59uFU, 30V = 115mA G0 b ‘The actwal output voltage is 6.51V; the Applicant requested it to be shown as 8.7V. FOR VARIANTS TYPE KFD2-STC4-EX1LH_AND TYPE KED2-STC4-EX120.H For terminals 7 to 12, 14 and 15, and power rail terminals 1 & 2:= Uy = 250V For Terminals Lang 3:= U,=27.2V [= 93mA —P,=0.632W 2nF L=0 ‘The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area load must not exceed the following values: GROUP ‘CAPACITANCE in | INDUCTANCE OR LR RATIO in mH ip pH ire ‘0077 42 S17 TB 0.678 117, 216 HA 2.288 36.0 456 1 40 519 a7 For Terminals 3 and 2 (& 5} Ue35V L=73mA — P.= 64mW WV = 11Tma Certificate Number BAS99ATEX7060 Issue 19 Issued 16 October 2015 Page 4 of 6 C Baseefa) ‘The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area load must not exceed the following values: GROUP CAPACITANCE in nF] INDUCTANCE OR TR RATIO in mit ing Te 00 oa I 332 iB 100 35 332 A. 100 50 332 | t i000 2 7207 For Terminals 1, 2(& 5) and 3:- Uj=272V = 1ITmA P= 0639W C= 120F = ‘The capacitance and either the inductance or the inductance (o resistance ratio (L/R) of the hazardous area load must not exceed the following values: GROUP CAPACITANCE in uF [ INDUCTANCE OR LIR RATIO in mit in pho ic. 0.077 32 3a. TB. 0.678 10 136 TA 2.288 20 272 1 i 40) 30 409) For Terminals 6 and 5 (2) U=87V 1-0 C= S.9MF OV = 117mA o ‘The actual output voltage is 6.51V; the Applicant requested it to be shown as 8.7V. ‘The above parameters apply when one of the two conditions below is given: ~ the total L, of the external circuit (excluding the cable) is < 1% of the Zy value or «the total C, of the external circuit (excluding the cable) is < 1% of the C, value. ‘The above parameters are reduced to 50% when both ofthe two conditions below are given: = the total L; ofthe external circuit (excluding the cable) =1% of the Ly value and = the total C ofthe external circuit (excluding the cable) =1% of the C. value. Note: the reduced capacitance of the external circuit (including cable) shall not be greater than 1uF for Groups I, HA & IB ‘and 600nF for Group IIC. 16 Report Number GBYBAS/EXTRI5.0306/00 17 Specific Conditions of Use None. 18 Essential Health and Safety Requirements Al relevant Essential Health and Safety Requirements are covered by the standards listed at item 9. Certificate Number Issued 16 October 2015 BAS99ATEX7060 Issue 19 GEE Page § of 6 19 Drawings and Documents New drawings submitted for this issue of certificate. ‘Number Sheet Issue Date Description 266-014B8-U Toft =U 2015-0ct1S Summary 266-014BS-02U 1-9 U_——2015-Oct-15 Components. ‘Current drawings also associated with this certificate 2010-Oct-L4 Transformer Details for T101 & T201 Number Sheet Issue Date Description 266-014B8-018 1-4 S 2010-Oct-14 Schematic 266-014BS-038 182 S 2010-Oct-14 Assembly 266-D10BS-04E. 1-15 E — 2014-Mar-27_ Mechanical Parts 266-014BS-05S 1-8 S 2010-Oct-14__ Main Printed Circuit Board 266-014B$-06S 1-6 s 266-014B8-07S 1&2 S — 2010-Oet-14 PCB Lacquering Details 266-014B8-10T. 1-3 T — 2014-May-12_ Type Label ‘These drawings are common to, and held with, IECEx BAS 04.0016, 20 Cerfifieate History Certificate No. Date Comments BASDIATEXTOGD Duly 1999 [The wlease of the prime cerifeate. The associated test and! assessment is documented in Test Report 99(C)0087. BASSBATEXTOSOTL 18 August 1999 — Minor electrical and mechanical changes. BASODATEXTOGOIS 78 August 1999 Minor electrical and mechanical changes. BASOOATEXTOOOS 30 Tune 2000 Addition of Din the apparatus narking @IL (GD. BAS99ATEX7060/4 ‘25 September 2000 | Minor changes to non-critical components and non-critical areas of | the PCB. | BASBDATEXTOO0S TA Febrary 2007 Minor changes to the PCB aed an alieatve trode core BASODATEXTOGOTS TZ December 2001 Aliernative ouput CLR and change to oulput parameters. Adaiion of hazardous area terminals 5 & 6. BASO9ATEXT060°7 + August 2002 | Minor drawing changes and altemaive specified components BASOVATEXTOGOS [1 October 2002 Minor change othe zener diode sltion range BASUDATEXTOGD9 ¥ March 3003 | Minor change to civeutand PCB. BASBVATEXTOGOITO ‘T December 2003 | Alemnative transformer design 4 BASBOATEXTOGOITI Te February 2004 | Changes to circuitry and component desigations, The associated assessment is documented in Test Report 04(C)0079 BASOWATEXTOSO/IZ Tune 2004] Minor electrical and mechanical changes. BASOGATERTOGHIS TE November 2005.” Changes to PCB layout BASOWATEXTOGOIIS F Seprember 2006 | Torbduction of variants KFDS-STCLERLH and KFDDSTCE Ext 20.H. The associated assessment is documented in Test Report 06(C)0830. BASOVATEXTO60/15 4 September 2007 Clarification of load parameters. Certificate Number S G BASOBATEX7O60 C Baseefa Issued 16 Seber 2015 Issue Certificate No. Date ‘Comments BASO9ATEX7060/16 15 January 2009 ‘Confirmation that the current design meets the requirements of EN 60079-0:2006 and EN 60079-11:2007 for [Ex iaJIIC and has additionally been assessed for compliance with the requirements of Associated Apparatus to EN 61241-11: 2005 i.e. the addition of IEx ia}, | BAS99ATEXTO60 Issue 17 | 25 January 2011 This issue incorporates previously issued primary and supplementary certificates into one certificate and permits minor drawing changes, BAS99ATEX7000 Issue 18) 31 October 2014 BAS99ATEX7060 Issue 19) 16 October 2015 ‘To permit changes (0 the transformer and to confirm that the equipment covered by this certificate has been reviewed against the requirements of EN 60079-0:2012 and EN 60079-11:2012 in respect of the differences from EN 60079-0:2006 and EN 60079- 11:2007 and that none of these differences, with the exception of ‘marking, affect this equipment. The equipment is now marked ® ue |exiacayuc © weyp es ia day mc ‘Test Report No, GB/BAS/EXTR14.0292/00 Project File No, 14/0400. To permit the use of alternative fuses and to confirm that the equipment covered by this certificate has been reviewed against the requirements of EN 60079-0:2012+A11:2013 in respect of the differences from EN 60079-0:2012 ard that none of the difference affected this equipment. Test Report No. GB/BAS/ENTR15,0396(00, Project File No. 15/0759. For drawings applicable to each issue, see original of that issue

You might also like