User’s manual C1K(s)/ C2K(S)/C3K(s) SANTAK ELECTRONIC (SHENGZHEN) CO., LTD PLEASE ABIDE BY ALL THE CAUTIONS AND OPERATION GUIDELINES IN THE MANUAL. DO KEEP THE MANUAL WELL. DO READ ALL THE GUIDELINES FOR SAFETY AND OPERATION BEFORE OPRERATING THE MACHINE. Guidelines for safety (1) The voltage of the output socket will still reach 220V although UPS is not connected with electric supply. (2) In case that the charging line and power line need changing, please purchase the materials from our company’s service station or our dealers in order to avoid insuffi nt capacity which results in heat, spark as well as even fire. (3) The deposal of the batteries and piles with fire is not allowed, for it will cause explosion and injury. (4) Don't open or damage the battery, because the electrolyte overflowing is rather poisonous and bad for people's health. (5) Don't short-circuit the anode and cathode of the battery, or there will be electric-shock or fire. (6) Don't open the crust of UPS arbitrarily, or there will be danger of electric-shock. (7) Don't touch the connection terminals of the battery. If the circuit of battery and input voltage circuit are not isolated from each other, there will be high-voltage dangers between the battery terminals and earth. (8) The connection with the blower, electri heater as well other electric appliances is not usually recommended for the sake of the safety of mac! es. Note: if there are some problems, please consult the professionals, dealers, SANTAK service station in the local areas as well as the service center in our head office(service hot line: 8008303938), due to the high voltage in UPS which may threaten the staff safety. Don't repair it arbitrarily. Il. Assembly guidelines: i to unwrap and examine 1, Unwrap the package of UPS and examine the accessories including one user's manual and one input power wire. As for long-acting UPS, the accessories should include one connecting line for batteries in addition to those mentioned above. 2. Check whether UPS has been damaged during transit. If any damage or shortage of work parts occurs, don't start the machine. Instead, inform the shippers and dealers of the problems the soonest possible. 3. Confirm the type of the commodity by going through the type description on the front panel and rear cover. Type | Kinds of machines | Type | Kinds of machine | C1K | Standard machine | C1KS | Long-acting machine | c2k | Standard machine | C2KS | Long-acting machine Standard machine | C3KS | Long-acting machine a ee Note: Please reserve the packing carton as well as packing materials for future transit. The commodity of this series is rather heavy. For hence, do handle it carefully. ii, Precautions for assembly: 1, The place where UPS is set must be ventilated, far from water, flammable gas and corrosives. 2. Don’t put it on one side. Ensure that the fresh air inlets below the front panel and the side face of the box, as well the bleed hole on the rear fan are not jammed. 3. The ambient temperature of UPS should be kept between 0°C and 40 C. 4, There may appear condensation water when assembling UPS under low-temperature condition. Therefore see to it that the machine has gotten dry absolutely inside and outside in advance of installation and utilization, or the danger of electrocution will be aroused. 5. Locate UPS near the socket of electric supply to convenience cutting off the power supply by taking out the plug. Note: (1) First turn off the load, second connect, and turn on the load one by one at last when the load is connected with UPS. (2) Connect UPS to the specified socket equipped with over-current protector. (3) Connect the power socket to the protective ground wire. (4) Insert the input power line to the socket of electric supply, UPS is nevertheless energized. Turning off UPS cannot de-energize the inside of said machir Therefore, the switch must be turned off first and then cut off electric supply to break power supply of UPS. (8) As for standard machines, charge the battery for 8 hours before using. UPS can automatically charge the battery provided the power plug is connected to the host machines. Without charging the batteries, UPS can still be used at once, only having less service time than standard. (6) The capacity need calculating as per the start-up power when choosing UPS, for the running power is too large provided motors, displayers, laser printer as well as other inductive load are connected to the machine. The start-up power is usually twice of the rated power. iii The figure for the appearance of UPS: Fig2-1 the rear cover board of C1K Fig2-2 the rear cover board of C1KS Fig2-3 the rear cover board of C2K Fig2-4 the rear cover board of C2KS Fig2-5 the rear cover board of C3K Fig2-6 the rear cover board of C3KS iv The connection of UPS input When connecting with power line, we shall use socket with over-current protector. In addition, the capacity of socket shall be taken into consideration. As for C1K(S) and C2K(S), their capacity need be over 10A, while C3K(S) needs a capacity of over 16A. In regard to the detailed connection, please consult Fig2-8(the input of C1K(s) and C2K(S)) and Fig2-9(the input of C3K(S)). Fig2-8 Fig2-9 v The connection for the output of UPS Output part | Socket Terminal body (ctKis) 2 Without installation leaks) 4 Without installation ee coKis) 3 Installation Pestiretinaieati aieavenel 4. As for the output of C1K (S) and C2K (S), only sockets are in demand. Just insert the load power line into the output socket. Please consult Fig2-10(the output of C1K(S) and C2K(S)). Fig2-10 2. In addition to using sockets, C3K(S) can use terminal body to effect output. Please consult the wiring steps as following and Fig2-11(the connection for the terminal body of C3K(S). Fig2-11 (1) Tear down the small cover board on the terminal body. (2) Do wiring with AWG14 or 2.1mm? materials. (3) Please check the fastness of the wires after finishing wiring. (4) Put the small cover board back into the box. vi The battery circumscription procedure of long-acting machine. 1. Pursuant to the different type of UPS, apply the correct battery voltage: 3 pieces of battery totally at 36V for C1KS, 8 pieces totally at 96V for both C2KS and C3KS. Abide by the instruction, more or less not allowed. 2. One terminal of the charging line is a pin used to connect UPS, while the other divided into three radius-type wires is used to connect the battery set. The procedure of battery connection is paramount. There will be danger of electric shock provided the detailed operation doesn’t conform to the certain procedure. Therefore, abide by the following steps without fails. (1) First connect the batteries in series to ensure the proper-amplitude voltage. (2) Connect the charging line to the batteries before connecting UPS, or the worker will risk electric shock. The red one is connected to anode “+”, the black one to cathode “.” and the yellow-green is connected to ground. 3. Don't connect UPS to any load before connecting it to power line which can offer electric supply to UPS. 4. The connection can be done by inserting the pin to the socket and then UPS starts to charge the battery set. Consult Fig2-12(the sketch map for the connection of long-acting battery of C1KS-C3KS). Fig2-12 Yellow-green: to the ground Red: to the anode of battery Black: to the cathode of battery IL The operation and running The operation of the said machine is very easy. Any training is not necessary; instead, operators only need going through the user's manual and conform to it when operating, i Operation: 4. Connect to electric supply and start UPS. (1)Connect UPS to electric supply. A procedure that UPS works in shunt mode or not once it has be connected to UPS can be set using ‘WinPower software downloaded from SANTAX web free of charge. (2)Press Starting -up key for at least 1 second before UPS is started. (3) Once UPS is started, will enter into self-checking procedure when all the indicator lights of load and battery on the panel begin shinning. Later, the indicator lights become extinct one by one, and the invert indicator lights will shine after several seconds, which means that UPS is running in the electric supply mode. If there is something wrong with electric supply, UPS will run in the battery mode. 2. Start UPS by using DC without connecting to electric supply. (1) Press the star \9-up key for at least 1 second to start UPS. (2) When starting UPS, everything will appear the same as connected to electric supply, only the electric supply indicator lights being extinct. 3. The shutdown of UPS when there is electric supply. (1) Press the shutdown key for at least one second to turn off ups. (2) The relative indicator light will shine if the setting procedure of WinPower is in shunt mode. And UPS runs in shunt mode. (3) The above-mentioned operation has been finished; nevertheless, there is output as for UPS. To stop the output of UPS, we can turn off the electric supply. And the output voltage of UPS will be terminated after the extinguishment of all the indicator lights inclusive of load ones and battery ones, leaving nothing displayed on the panel. 4, Start UPS by using DC without electric supply. (1) Press the shutdown key for at least 1 second to turn off UPS. (2) Before UPS is absolutely turned off with output voltage terminated, it will enter into self- checking procedure, with indicator lights of load and battery on the panel crushing out ‘one by one till nothing is displayed on the panel. ii Operation mode 1, Electric supply mode We can consult Fig3-1 for the indications of panel running in the electric supply mode. The indicator light of electric supply and invert indicator lights will shine and the load indicator light will be lightened pursuant to the load capacity. Oy The indicator lights for the electric supply twinkling means that the zero conductor and live wire are not connected right and UPS is still running in electric supply mode; the battery indicator lights shining shows that the voltage and frequency of electric supply have exceeded the normal range, with UPS running in battery mode. (2) Provided the load indicator lights are over 100%, the buzzer will buzz every half second to remind you of overload until you dismiss the unnecessary ones in sequence and the load of UPS becomes less than 100%. (3) The battery indicator lights twinkling means that UPS is not connected to batteries or the battery voltage is too low. So check the battery connection and inspect the battery by pressing start-up key for one second. If there is nothing wrong with connection, the problem may result from the battery failure or aging. Please consult the table of fault clearance in Chapter6. Note: IFit connects with generator, procedure should be followed as below: © Start the generator. When the generator runs stably, connect them together (make sure that the UPS is unloaded), and then start up UPS. After UPS started up, connect load one by one. ‘© Suggestion: select generator volume according to twice UPS volume 2. Battery mode See figure 3-2 for panel indication under battery mode, and battery indication light and inversion indication light are both illuminated. if abnormal electric supply is connected, the electric supply light will twinkle at the same time. Battery volume light will be illuminated according to size of the battery volume. 1) When UPS is running under the battery mode, buzz will alarm every 4 seconds. If press start button for above 1 second, UPS will execute muffle function, and the buzz will not alarm any more. If press the start button for above 1 second again, the alarm will recover. 2) When the battery volume decreases, quantity of illuminated battery volume lights will diminish. When battery voltage decrease to alarm level(it can keep supplying power for 2 minut ), and the buzz will alarm every 1 second to remind the user that the battery supply is insufficient. The user should stop all the loads one by one immediately. 3) Check backup function though UPS without connection of electric supply, 3. Bypass mode (Set the UPS bypass status by Winpower) See figure 3-3 for panel of bypass mode. Electric supply light and bypass indication light are illuminated, and load fight will be illuminated according to volume of the loads. The UPS will buzz every 2 minutes. 1) Ifelectric supply indication light is twinkling, that means voltage and frequency of the electric supply exceeds the allowed range or neutral and line are reversed, 2)_ Indications of the other panels are same with the description of electric supply mode 3) UPS possesses backup function, when it is working under bypass mode. The power supply of the loads are supplied by electric system through filtering at this time. 4 Abnormal mode If the UPS fault indication light is illuminated, that means the UPS is running under abnormal mode. See abnormal status troubleshooting table for eliminating the fault IV. Panel indication lights instruction ‘1# Indication light: fault indication light 24 Indication light: load/battery volume indication light 3# Indication light: load/battery volume indication light 4# Indication light: load/battery volume indication light 5i# Indication light: load/battery volume indication light 64 Indication light: load/battery volume indication light 7# Indication light: bypass indication light 8# Indication light: electric supply indication light 9# Indication light: inversion indication light 10# indication light: battery indication light JPHLEE 77M: Start-up button and muffie button ABU: Shutoff button Power supply switch: press I" on front panel for 1 second to start up the UPS; press “~/ for 1 second to shut off the UPS 7# Bypass indication light (orange light): this light indicates the power supply of the loads is directly supplied by electric supply. 8# Electric supply indication light (green light): this light indicates electric supply works normally, 9# Inversion indication light (green light): this light indicates the power supply of the loads 's supplied by electric supply or battery thought UPS. 10+ Battery indication light (orange light): This light indicates power supply of the loads. is supplied by the battery through the UPS. +# Fault indication light (red light): this light indicates UPS abnormal conaition. 2#~6# (2H is orange light, 3#~G# are green lights): the lights here indicate the load volume and battery volume. Under electric supply mode, they only indicate load volume; under vattery mode, they only indicate battery volume. V. Display of panel lights and their relevant working status table Display of Panel lights | Status ‘)2[3[4 8/6/78 910 Alarm | alalel@leleleie a) # 1 ~_0~35% load vot { [el [ete none 2 Electric | 36-55% load vol. ele] lee none 3] supply | 56-75% load vol. [eleje| ee | none 4 Mode | 76-95% load vol. | Tel oe “none j 5 96-105% load vol. | @ none 6] 0-25% Battery vol e| fT ‘Alarm every 1 sec. 7 26~50% Battery vol cele l @ © Alarm every 4 sec. a Sate 51-78% Batteyvol | [elele ©) © | Alarm every 4 sec 8 [Te-100% Batteyvol ele ele © [8 | Alarm avery 4 a8 10 | | 100% Batteryvol |e fee le 0” @ | Alarm every 4 sec. 1 Bypass mode Lith [eter ‘Alarm every 4 min 12 Overload under electric supply eleje ls [ele Alarm atways mode, transfers to bypass | [es I a 13 | Overload under electric ‘supply elias 2 alarms every 1 mode, doesn't transfer to bypass | sec. 14 ‘Abnormal electric supply tltltlrfelt iar |: + 15 “Overload of battery mode under | ie . 2 alarms every 1 precaution | sec. ag | Ovetload of battery made, output | cane is shutdown 4 "Over temperature Alarm always normal inversion ‘Alarm always normal BUS voltage Alarm always 20." Overvolage of charger outbut ‘Alarm always 21 Abnormal battery voltage _ : . 22, Reverse line and neutral 23" Change piate or battery is broken ¢ 24 Shortcircuit of output Fan works abnormally tion instruction: © Illuminating. #: Twinkling, ~ light display depends on other status. arm very 2 min Alarm very 1 sec. Alarm always Alarm very 1sec VI. Troubleshootings Fault Reason Treatment Make sure the UPS is not overload, and ventiis not jammed, or indoor temperature | is too high. Coo! the UPS for 10 | minutes, and restart. If it still failed, please contact your supplies 41# fault indication light and 6# indication UPS shuts down because of light are iiuminated, over temperature buzz always alarms “# fault indication | light and S# indication | UPS shuts down because of | light are illuminated, | internal fault buzz always alarm +H# fault indication light and 4# indication UPS shuts down because of light are ituminated intemal fault |_buzz always alarm 144 fault indication | light and 3# indication | UPS charger faut, please Please contact your supplier. Please contact your supplier UPS overcharge protection light are illuminated, contact your supplier buzz ys alarm Voltage and frequency of UPS is under b: cl i electric supply exceed UPS Seer | this time, save data and close all input range. (When started the applications, and make sure up, UPS will alarm twice very | | the electric supply is within the 1 second, and it will alarm 8 range of UPS input times.) Neutral and line are reversed 8# electric supply indication light is twinkling. Reconnect the neutral and line alarm very 2 minutes 1 fault indication light and 24 6# UPS fan is not connected or indication lights are Please contact your supplier broken illuminated, buzz wil alarm every 1 second sg Check load level and remove aloe unimportant device. Recalculate 7 light anc 2# light are UPS overloads under battery load power and reduce loeds lluminated, buzz mode or load devices fault connected with UPS, and check always alarms load fault “i fautindicaion Shorr of UPS output! Tum of UPS, and remove all the ight and 2i 5 ights loads. Make sure that there is no are illuminated, buzz fault and internal shortcircuit of always alarms, the loads, Restart UPS. {fit stil failed, please contact your ee i supplier. | Check the battery and reconnect 10# battery light | Undervoltage of the battery or the battery. if the battery is, twinkling battery is disconnected broken, please contact your supplier | “1# fault indication | ight is illuminated, | and 10# battery light Charge part fault Please contact your supplier larm every 1 second is twinkling, buzz | Abnormal electric | i supply, UPS can not Breaker of UPS isnot closed | Manually close the breaker connect the electric | supply: - { - jo Keep charging the batt ieuficenchrge rected oe urs | : hi i i Battery discharging oo Gheck load level and remove time is too short unimportant device Battery is aging and capacity | _ Replace the battery, please _ decreases |_contact your supplier | Time is too short for press the | Press start button over tsecond start button to start UPS. al Press down start | UPS does not connect the | Connect UPS battery. If batter button, but UPS can battery, or battery is - voltage is low, start it without not be started up _undervoltage and started with, : he _ load | intemal fault of UPS | Please contact your supplier ‘When you contact with maintenance man, please offer below documents vi 1 2 Model No. and Serial No. of UPS Occurrence date of the problem Complete problem description (Including display of indication light. sound, and electric status, {oad volume. if tis a long acting UPS, please offer battery information) \|, Notes of battery treatment Prior to battery treatment. take off metal ornaments, such as ring, watch ete Please order the material for battery wire replacement to avoid causing fire because of insufficient capacity. To treat the battery with fire is forbidden, injury may be caused by explosion To damage or open the battery is forbidden, overflowed electrolyte contains very dangerous toxic substance 5. Avoid shortciruit of positive pole and negative cole, otherwise fire or electric stroke may be caused. 6. Check battery voltage before touching the battery Do not isolate battery loop and input voitage loop. Battery terminal and the ground exist dangerous voltage 7. Please see chapter 4 for battery maintenance vi. maintenance guarantee We promise: our customer can be offered free maintenance service for 3 years since the purehase day: (1) Taking maintenance service by presenting distributors’ valid certificate (2)Taking maintenance service as per PN of the equipment he transit fee during the maintenance period goes to the users’ accout Please contact, SANTAK service branch and the distributor nearby if the equipment is at fault. Our user ean enjoy the following servie (1)3-year maintenance guarantee (including the battery) (2)Serviee hot line for 24 hours (3)Joint maintenance guarantee nationwide (4)Free drop-in maintenance service within the guarantee period (only for UPS of whieh the capacity is over 6KVA) The following situation is beyond the service guarantee scope: (1) Man-made failure ©)Beyond the guarantee period; (3yThe product of which the part number has been changed or lost; (4yThe dam: (5)The product which has been dismantled or modified without being authorized: .e ot loss resulting from the force majeure or other external causes; (6)Violate the operation rules of the equipment; (7)Deep discharge of the battery or man-made dam: Note: we regret to tell you that we will not notify you separately if the above content is changed. SANTAK reserves the final right to interpret. Appendix 1 EMC grade standard Castle serial products are manuf CIK(SVC2KS "EMS TEC 1000-4 Appendix 2 the introduction of common marks These following marks can either be used in the said manual or in practice, Therefore, please be familiar with them and have a good ideal about their meaning. Marks and their meanings Meaning, Notice High-voltage hazard | ~) To turn on UPS) I oO | To turn off UPS To Stand by or turn off UPS. AC DC | Grounding protection | Alarm and exseind (sound deadening ) | Overload indication Battery checkup Repeated circulation Non-existence with sundries Appendix 3 product performance lectrie performance Type CIKICIKS [| C2K/C2KS C3KIC3KS Load criterion 2000VA/1400W | 3000VA/2100W | 3000VA/- we tandard frequent aow Standard vol Input _ Type CIKICIKS | C2K/C2KS | CIKICIKS | “Voltage scope (single phase) LSV-300VAC "se0 | 40H2-60Hz 2097 CIKICIKS —[C2KICKS | GSKIC3KS EQW)VAC Frequeney error allowance (battery mode) 50X(1E0.2%)He T Shift te shunt mode 300VSEL later upon Voltage allowance _ 220% ‘Overload capacity loading more than 150% ‘Shift to shunt mode afer 30-second running with the load over 1102 (max) Peak load ratio voltage CIKICIKS Standard voltage | 36VDC [C3K/CEKS ‘96VDC of batiery Backup time The hockyp time of long-acting machine varies following the capacity of externul-commected utters Type Commercial power mode ——-shunt mode Commercial power mode ——battery mode Working environment Type a Temperature Relative humidity Altitude CIKICIKS | OMSEL _ORIOKS —_CGKICIKS. 4 MISEL the standard time is 25 MSEL) [ENCS [ERCERS [GENS To cesia cage (0-95% non-condensing water 0 Celsius d Less than 1500m above the sea level Storage temperature Mechanical performance 25 Celsius de Celsius dewree Type [ CIKICIKS KICIKS | C3KIC3KS Specification W*DFHi¢mm) _| 145*400% 1924460340 192460"340 (kilogram) | Net 147 34/135 345/14 weight | | Total 15/8 3615.5 36.516 int Enterprise criterion Enterprise iterio Appendix 4 communication interface port Computer interface There is a standard DBO socket on the rear cover-board of Castle serial product. The seid interface offers several signals allocated as follows: [Allocation explanation ‘Neutral pin Transmission a Newalipne eee os 5 a [GND 6 Neutral pin - ae | Neutral pin 8 | Neutral pin 9 [Awake | . ~ “| Computer interface a i a Network communication There is an intelligent slot installed for intelligent network card (choice fitting) on Castle serial UPS. The specified imellectual network card can be compatible with currently popular system. In addition, it ean back the operat ger etc: it can endow LPS with systems, hard-soft ware and the network oper work such as HP openy sage can be vaken over and the nection at once. The on and man ing systems can be achieved Please contact the local agent for detailed information, @ SANTAK SANTAK ELECTRONIC COM., LTD Factory address: NO.8 Baoshilu road, District 72 of Bao'an, Shenzhen city Customer service hot Line: 8008 c x 07, Cust inail address: specialist @santak.com.en 572730 service crsion of the manual can he downloaded fom SANTAK WEBSITE Website: www. Nowe: the latest

You might also like