Professional Documents
Culture Documents
SPECTROMETER
·PRECISE
·RELIABLE
·FAST
·VERSATILE
CX-9800 Spectrometer provides the ideal performance and fit for product assurance
testing and material identification. This spectrometer delivers maximum convenience and
reliability based on CCD technology.
CCD-4
SPECTROMETER
CX-9800 OPTICAL EMISSION SPECTROMETER
Specifications:
Optical Structure Paschen-Runge Mount
Full Spectrum
Dimension 830mm(L)*700mm(W)*460mm(H)(Benchtop)
830mm(L)*700mm(W)*1230mm(H)(Floor Module)
120Kg(Floor Module)
Power AC220V/50Hz
Core Components
16 Printer HP America
Read-out System
·Ethernet data transmission based on DM9000A
·High performance Read-out System processes
the spectrum data five times faster than traditional
systems
Excitation Source
·Optimized ignition parameters
·Pre-spark with high discharge energy
·HEPS digital excitation source
·Maximum power : 700w,standby 40W
Software
·High accurate analysis results are easily achieved.
·Status monitor in sparking
·Microsoft Windows 7 operating system
·Strong Database capability
·Customized format of report
Optical system
·Multi-CCD detectors with high resolution
·Paschen-Runge structure with full wavelength
coverage
·Saving valuable analytical time and enhancing
accuracy and detection limits.
·Incorporate sample excitation and automated
sample monitoring techniques.
Electrical and Environmental
Requirements:
·Voltage : AC220V, 50Hz
·Temperature : 10℃ ~30℃ .
·Humidity : 20%~80%
·Purity of Argon :99.999%
Dimensions
Bench top Floor model
Length 500 mm 830 mm
Width 450 mm 700 mm
Height 300 mm 1450 mm
SPECTROMETER
CX-9800 OPTICAL EMISSION SPECTROMETER
SPECTROMETER
The Quantity of Measured Elements and also
The Top and Bottom Borders of Ranges of Concentrations.
C X -9 8 0 0 A n a l y t i c a l m o d u l e o f A l -b a s e
A L -0 0 0 A L -0 0 1 A L -0 0 2 A L -0 0 3 A L -0 0 4 A L -0 0 5
NO. El e m e n t A l- o r ie n t a t io n p u r e / lo w a llo y A l/S i- a llo y s A l/Z n - a llo y s A l/C u - a llo y s A l/M g - a llo y s
1 Si 0 .0 1 -2 4 0 .0 1 -1 .2 0 .0 2 -2 4 0 .0 2 -9 .4 0 .0 2 -7 0 .0 2 -2 .3
2 Fe 0 .0 1 -4 0 .0 1 -4 0 .0 2 -4 0 .0 3 -1 0 .0 5 -1 .9 0 .0 7 -0 .8
3 Cu 0 .0 0 2 -6 0 .0 0 2 -1 0 .0 0 5 -6 0 .0 1 -4 .3 0 .0 1 -1 3 0 .0 0 7 -1
4 Mn 0 .0 0 1 -2 .4 0 .0 0 1 -1 0 .0 0 5 -1 0 .0 2 -1 0 .0 5 -1 0 .0 3 -2 .4
5 Mg 0 .0 0 2 -4 0 .0 0 2 -1 0 .0 1 -1 .5 0 .0 1 -4 0 .0 1 -2 .7 0 .0 0 6 -1 0 .2
6 Cr 0 .0 0 1 -0 .5 0 .0 0 1 -0 .1 5 0 .0 0 5 -0 .5 0 .0 1 -0 .4 0 .0 1 -0 .1 4 0 .0 1 -0 .4
7 Ni 0 .0 0 1 -2 .5 0 .0 0 1 -0 .1 6 0 .0 2 -2 .5 0 .0 1 -0 .2 0 .0 1 -2 .3 0 .0 0 5 -0 .2 5
8 Zn 0 .0 0 2 -1 2 0 .0 0 2 -0 .5 0 .0 0 5 -3 .5 0 .0 1 -1 2 0 .0 5 -3 .5 0 .0 1 -1
9 Ti 0 .0 0 1 -0 .4 0 .0 0 1 -0 .1 5 0 .0 0 5 -0 .4 0 .0 0 5 -0 .3 0 .0 0 1 -0 .2 0 .0 0 7 -0 .3
10 Pb 0 .0 0 1 -0 .5 0 .0 0 2 -0 .5 0 .0 0 5 -0 .5 0 .0 0 5 -0 .5 0 .0 1 -0 .5 0 .0 0 1 -0 .5
11 Al Balance Balance Balance Balance Balance Balance
SPECTROMETER
CX-9800 OPTICAL EMISSION SPECTROMETER