You are on page 1of 8

Profile Plus

Series ICP
The Affordable PMT Based ICP
The Profile Plus Family of ICP Spectrometers
Profile Plus makes ICP simple and very fast. This system integration). As a result, low concentrations and complex samples
will quickly become your laboratory workhorse, not a are easy because the location of the analyte peak is known before
research project. the analysis is carried out. Time is spent measuring the peaks, not
searching to find them. When compared to CCD based sequential
ICPs, the Profile Plus provides up to four times the analysis speed
Need flexibility?
and has fewer interferences.
The Profile’s “any element, any wavelength” capability makes
it the system of choice. All internal optical components are
stationary, resulting in extremely stable spectral output. With
Versatile Design
Profile Plus is the most versatile family of ICPs in the industry and
this patented design, the Profile’s detector is moved at very high
can be configured for almost any application.
speed from the center of one wavelength to the next (on-peak

High Performance Optics


With ICP emission, elemental concentrations are determined by Profile’s Echelle optics disperse the spectrum, widely separating
measuring light intensities at discrete wavelengths. Because the the wavelengths thereby minimizing interferences and the need
ICP is a very high temperature source, it emits many thousands for interelement corrections. This design improves resolution —
of wavelengths — a “complex spectrum.” The job of the the ability of a spectrometer to distinguish between two closely
spectrometer’s optics is to make sense of this information and the spaced wavelengths — without reducing the amount of light
best way to do this is to use an Echelle optical system with a large that gets to the detector. The result is an instrument that can give
output format. In fact, Leeman Labs was the first ICP spectrometer high resolution and low detection limits at the same time — a feat
manufacturer to employ this design. impossible for conventional and small format echelle designs!
Axial, Radial, or Dual View
Profile’s Echelle design is ideally suited to allow observation of the plasma in
the radial, axial, or dual view modes. Its elegant entrance optics provide this
flexibility without the need for complex lens/aperture systems, as required
by other ICP systems. With Profile Plus, fewer optical surfaces mean more
light throughput and therefore lower detection limits.

The traditional radially viewed plasma has a well-deserved reputation


for robustness and is the configuration of choice for many applications.
Providing detection limits that are approximately ten times better than a
radial system, the axial plasma has taken ICP into application areas that were
previously difficult, if not impossible.

Combining the best features


of axial and radial viewing is
the dual view system. Capable
of running in both radial and
axial mode (on an element-
by-element basis in a single
method), the dual view is able
to analyze virtually any sample
for ultra-trace, trace and major
elements without the need for
multiple sample dilutions.

The Profile Plus combines


superb analytical capability,
versatility, and performance
into an easy-to-use benchtop
design.

The Profile’s design uses fewer optical surfaces, maximizing


light throughput for superior detection limits.

3
Easy To Use Sample
Introduction System
Traditionally, most operating errors occur in the sample introduction The Profile Auto-Align Torch System eliminates the guesswork usually
encountered when installing torches and spray chambers.
area. The Profile Plus family has a new Auto-Align Torch System that
eliminates the guesswork usually encountered when installing torches
and spray chambers. Designed with the users’ needs in mind, the Auto-Align Torch
precisely repositions the torch, whenever removal and replacement is needed. Every
operator will be able to perfectly position the torch every time; consistently generating
high quality results.

The Auto-Align Torch System makes it easy to configure your Profile Plus to handle even
the most difficult analytical applications. A wide selection of sample introduction hardware
is available, including systems for use with aqueous, organic and HF samples. Each is easily
integrated with the Auto-Aligh Torch system.

High Efficiency ICP Power Supply


Incorporated into the Profile Plus is a state-of-the-art power supply. Its fast switching
design compensates for fluctuations of incoming power, resulting in outstanding stability
without requiring expensive line conditioners. This means faster warm-ups, and superior
analytical reliability.

The power supply is built into the body of the instrument, resulting in a compact,
benchtop spectrometer. This reduces laboratory space, to an absolute minimum.

The Profile Plus uses the Teledyne Leeman Labs 40.68 MHz free running oscillator for
superior tolerance to a wide variety of sample types, including high solids and organics.
Software Element Selection

Teledyne Leeman Labs’ WinICP software is designed to fully control


the analytical process — from Method Development to Final Report
Generation — providing the right amount of flexibility, without the
complexity. In the routine analytical or research environment, WinICP
has the features along with the ease-of-use necessary to get the job
done quickly and efficiently.

Element Selection
Select an element from the periodic chart. Choose the best wavelength
from the list or any other wavelength. Use as many (or as few) defaults Scan Page
as you wish to streamline data entry for each element — all standard
and check standard concentrations, as well as integration times can be
entered with a single button.

Scan Page
Simply scan a standard and sample to quickly estimate a concentration,
set a background point or identify possible interferences.

Calibration
Automatically run a calibration using up to 10 standards and 7 check
standards by placing the standards into the autosampler and initiating
the cycle. Calibration plots can be viewed quickly and easily.
Calibration
Select the autosampler rack and specify the number of samples to be
analyzed and the Profile Plus goes to work. WinICP also lets you turn
elements on or off without having to open the method.

Generate reports with as much or as little data as you wish. Take


advantage of WinICP’s ability to output data in a variety of formats,
making compatibility with other software applications straightforward.

Sample Analysis Report Generation

5
Specifications
Wavelength Range 177 – 800 nm
Resolution <0.008 nm @ 200 nm
Detector Type High Speed PMT
RF Generator Type 40.68 MHz, Free-Running
RF Generator Output 2 kW
Peristaltic Pump 4 Channel, 12 Roller

Spectrometer/ICP Source Electrical Requirements


Mounted on a single base chassis on 1” (25 mm) rubber feet Grounded Single-Phase Power Supply 190 – 230 V, 30A, 50/60Hz
Length Base 52.2” (1326 mm) Outlet Type Hubbell Twist (NEMA L6-30R)
Additional Outlets:
Depth Base 21.7” (550 mm) 115V, 15A, 60 Hz or 220 V, 10A, 50Hz
(for computer, monitor and printer)
Height (to top of chimney) 29” (735 mm)
Diameter of Chimney 6” (152 mm)
Weight 230 lb (104 kg)

Environmental Conditions Exhaust


Temperature 59 – 86 F(15 – 30 C)
o o
Exhaust Draw 100 ft3/min (2.83 m3/min)
Maximum Temperature Variation 3.6 oF/h (2 oC/h) Vent Diameter 6 – 8 “ (152 – 203 mm)
20 – 80% 3 – 4” (76 – 102 mm)
Relative Humidity Vent Height
(non-condensing) above chimney

Water Recirculator Gases


Length 16.5” (420 mm) Argon (required)
Height 12.5” (317 mm) Purity 99.995% minimum
Depth 18” (475 mm) Delivery Pressure 80 – 95 psi (560 – 630 kPa)
Weight 50 lb (12 kg) Nitrogen (optional for purge)
Purity 99.995% minimum
Delivery Pressure 80 – 95 psi (560 - 630 kPa)
Site Planning Information

More than Just an ICP Standards


As you know, beyond the initial purchase price lies the true cost of Teledyne Leeman Labs prepares and validates a line of standards
ownership, and that’s where the Profile Plus shines. Why? Because and reagents for both sample digestion and analysis (Plasma-
Teledyne Leeman Labs builds these instruments to last. Pure). Plasma-Pure standards provide analysts with accurate,
stable standards, made from high purity materials (traceable
After Sales Support to NIST standards). With Teledyne Leeman Labs you have an
Telephone Support:  Our technicians and support chemists analytical partner, ready to provide support for the chemistry, as
can resolve most application, operation, maintenance, and well as the mechanics, of your application.
troubleshooting questions over the phone. A toll free hot line
staffed with specialists trained in emergency repair is available to You’re in Good Company
assist you. Are you getting the impression that we stand solidly behind
our instrumentation? You’re right. Our confidence comes from
Remote Diagnostics:  Remote diagnostics software provides our knowing that we haven’t cut corners in the design, maintenance
technicians and scientists with the ability to access an instrument or testing of our products. We build our instruments to the most
via the internet. Specialist support is always at hand. exacting specifications. We build them to do the job, and to do it
right. It’s a reputation that we worked hard to earn, and that we
Service Agreements work harder to maintain.
A variety of optional service agreements are available including:
So what kind of companies and organizations rely on analytical
Full Maintenance: A set rate comprehensive package that allows instruments from Teledyne Leeman Labs? Our customers come
the user to budget for each instrument under the agreement. from both the public and private sector. They are leaders in
industry, government, and academia. Add to the list hundreds
Limited Maintenance:  Allows the user to budget for costs of cities, municipalities, and institutions of higher learning and
associated with replacement parts and technical support. This you start to get a sense of the family of Teledyne Leeman Labs
agreement is designed for the user who performs their own customers, and the impact that they have on our society.
maintenance.
We continue to invest heavily in research and development and
Preventative Maintenance:  Designed to keep your equipment look forward to providing our customers with additional products
in peak working condition and to note any items that may lead to and technology advances in the years ahead.
future problems.

7
ICP Spectrometers Mercury Analyzers DC Arc Spectrometers Inorganic Standards

6 Wentworth Drive
Hudson, NH 03051 U.S.A.

Tel: 603.886.8400
Fax: 603.886.9141
Email: LeemanLabsinfo@teledyne.com

www.leemanlabs.com

MADE IN THE USA Copyright © 2012

You might also like