Energy technology
»» Delivery and circulation in closed circuits
»» Feeding boilers in boiler systems and steam generators
»» Tank systems, including delivering liquid gas
»» Delivery of diesel in backup generators in power stations
Further applications
»» Delivery of salt water and fresh water in ships
Contact an representations
Speck Pumpen Walter Speck GmbH & Co. KG
Speck Pumpen Systemtechnik GmbH
Regensburger Ring 6 – 8
91154 Roth / Germany
T: +49 9171 809 0
F: +49 9171 809 10
info@speck.de
www.speck.de
International representations
See page 28
2
Side channel pumps made by Speck
High operational safety, optimal design and service-friendly
Proven side channel pumps for universal applications Combi-pumps for delivering liquids in physically difficult conditions on the
suction side
Their very good NPSH values make them particularly suitable for pumped
media near the boiling-point
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 3
The right pump for your system
Choose from eight series
Each system is unique in its own way - on some, the sealing principle is key, on others the installation frame or perhaps the special properties of the medium. You
can choose from eight series and find the best solution for your system.
Sealing Design
4 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
SK series ASK series
Main dimensions in acc. with EN 734 Combi-pumps with NPSH suction stage
»» Proven side channel pumps for universal applications »» Combi-pumps for delivering liquids in physically difficult conditions on the
suction side
»» Their very good NPSH values make them particularly suitable for pumped
media near the boiling-point
SKG-LL
SKG-L0 ASKG
SKG-LA
SKM ASKM
SKM-LT ASKM-LT
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 5
Modular system
With Speck you get a modular system with many identical parts.
SK series
SKG-LL SKG-L0
8 5 7 2 4 3 6 1 7 8 2 9 4 3 5 6
SKG-LA
2 9 4 3 5 6 1 7 8 15a
SKM
1 9 3 45 6 2 12 13 15b
SKM-LT
Version with ceramic can
and secondary seal (16)
1 9 3 45 6 2 12 13 15b 16 14
6 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
SKG-LL SKG-L0 SKG-LA SKM SKM-LT ASKG ASKM ASKM-LT No. Designation / notes
x x x x x x x x 1 Suction casing
x x x x x x x x 2 Discharge casing
x x x x x x x x 3 Suction stage
x x x x x x x x 4 Discharge stage
x x x x x x x x 5 Shaft
x x x x x x x x 6 Star impeller
x x x x 7 Mechanical seal (or stuffing box packing, not illustrated)
x x x x 8 Rolling bearing
x x x x x x x 9 Sleeve bearing made of SiC (or carbon bearing, not illustrated)
x x x 10 Stage N
x x x 11 Radial impeller
x x x x 12 Bearing cartridge made of SiC
Magnetic coupling,
x x x x 13
can made of Hastelloy® or ceramics
x x 14 Bearing bracket
x x x x x 15a / 15b Bracket
Secondary seal (radial shaft sealing) for magnetic
x x 16
couplings with ceramic can
ASKM
1 11 10 9 3 45 6 2 12 13 15b
ASKM-LT
1 11 10 9 3 45 6 2 12 13 15b 14
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 7
Versions
Type code with versions and material designs
Table 1: Sealing
Code M G S
Magnetic coupling Mechanical seal Stuffing box packing (on request)
Table 2: Versions
ASKG / ASKS SKG /SKS ASKM / SKM
Code – LL L0 LA - LT
Stage number 1-8 1-8 1-8 1-3 1-8 1-8
Bearing suction-side Sleeve bearing Rolling bearing Rolling bearing Rolling bearing Sleeve bearing Sleeve bearing
Bearing pressure-side Rolling bearing Rolling bearing Sleeve bearing Sleeve bearing Sleeve bearing Sleeve bearing
Mech. seal / Stuffing box p. suction-side – x/x x/x x/x – –
Mech. seal / Stuffing box p. pressure-side x/x x/x – – – –
Design Base plate version Base plate version Base plate version Bracket version Base plate version Bearing bracket,
base plate
Elasto- SiC / SiC / SiC / Elasto- SiC / SiC / SiC / SiC / SiC / SiC /
Properties mer A carbon B carbon SiC Properties mer A carbon B carbon SiC A carbon B carbon SiC
FFKM 110 220 330 FFKM 010 020 030 110 220 330
Suction-side: unbalanced
Unbalanced
Pressure-side: unbalanced EPDM 112 222 332 EPDM 012 022 032 112 222 332
uncooled, up to 140 °C
uncooled, up to 140 °C FKM 113 223 333 FKM 013 023 033 113 233 333
FFKM 140 250 360 FFKM 040 050 060 440 550 660
Suction-side: unbalanced
Balanced
Pressure-side: balanced EPDM 142 252 362 EPDM 042 052 062 442 552 662
uncooled, up to 140 °C
uncooled, up to 140 °C FKM 143 253 363 FKM 043 053 063 443 553 663
FFKM 440 550 660 FFKM 070 080 090 770 880 990
Suction-side: balanced
Balanced
Pressure-side: balanced EPDM 442 552 662 EPDM 072 082 092 772 882 992
cooled, up to 180 °C
uncooled, up to 140 °C FKM 443 553 663 FKM 073 083 093 773 883 993
FFKM 770 880 990
Suction-side: balanced
Pressure-side: balanced EPDM 772 882 992 000: Stuffing box packing (SKS / ASKS)
cooled, up to 180 °C FKM 773 883 993 XXX: Special version, details in order-related documents
8 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Table 4: Size of magnetic coupling
Code no. 51 52 61 62 63 71 72 73 74 75
Size 60-40 60-60 75-40 75-50 75-60 110-40 110-50 110-60 110-70 110-80
pmax. bar 40 40 40 40 40 25/40 25/40 25/40 25/40 25/40
Code no. 81 82 83 84 85 91 92 93 94 95
Size 135-50 135-60 135-70 135-80 135-90 165-80 165-90 165-100 165-110 165-120
pmax. bar 40 40 40 40 40 25/40 25/40 25/40 25/40 25/40
ASK
Sealing Code no. 11 20 30 31 40 60 61
G S M Parts
x x x Suction casing EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 1.4581 1.4581 1.4581
x x x Discharge casing EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 GBz 1.4581 1.4581
x x x Stage EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 GBz 1.4581 1.4581
x x x Stage / NPSH EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 1.4581 1.4581 1.4581
x x Shaft seal casing EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 GBz 1.4581 1.4581
x x x Star impeller GBz 1.4408 1.4408 1.4408 GBz 1.4408, hardened 1.4408, hardened
x x Impeller / NPSH EN-GJL-250 EN-GJL-250 EN-GJL-250 1.4408 1.4408 1.4408 1.4408
x x x Shaft 1.4122 1.4122 1.4122 1.4122 1.4571 1.4571 1.4571
x x Pump frame1 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15
x Pump frame2 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 EN-GJS-400-15 1.4581 1.4581 1.4581
x x Temperature limits 0 up to +180 °C 0 up to +1 80 °C 0 up to + 180 °C 0 up to + 180 °C 0 up to + 180 °C 0 up to +180 °C 0 up to + 180 °C
x Temperature limits -20 up to +200 °C - 40 up to + 350 °C - 40 up to + 200 °C - 40 up to + 200 °C 0 up to + 180 °C - 100 up to + 250 °C - 40 up to + 350 °C
1 no contact with the medium
2 in contact with the medium
The operating limit values result from the max. permissible pressure and the max. permissible temperature as well as the pumped
medium with its specific vapour pressure. See "Dimensioning" Page 11.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 9
Quality assurance and tests
Modern, computer-controlled and fully automated test stands on the premises of Speck
Thermal oil test stand with pump surveillance system on the premises of Speck in Roth.
Research of impacts of high temperatures up to 350 °C on the lifetime of the pumps.
10 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Order-related tests and dimensioning
If you want to use pressure tests according to different criteria, please enter The maximum pump outlet pressure p2max op is calculated using the formula:
them in the request.
38 bar
Temperature measurement
36 bar
The measurement is taken on the motor-side bearing at operating tempe-
rature. The operating temperature and the ambient temperature at every 34 bar
operating point measured are documented. 32 bar
30 bar
28 bar
26 bar
-100 °C -50 °C 0 °C 50 °C 100 °C 150 °C 200 °C 250 °C 300 °C 350 °C
Maximum permissible casing operating pressure pall w c
EN-GJS-400-15: spheroidal graphite cast iron
1.4581: stainless steel
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 11
Magnetic couplings
Wide range
Magnetic couplings consist of an inner rotor, a separating can and an outer
rotor. The separating can seals the pumped media from the atmosphere.
A great variety of sizes and configuration using the latest software guarantee
the best design for your operating point.
The transmissible torques of the magnetic couplings range between
10 and 500 Nm.
The universal linear PT-100 temperature sensor with a detection range from -
100 to + 400 °C is available in three versions.
»» Standard design
»» ATEX design without SIL/IPL2
»» ATEX design with SIL/IPL2
All three versions can be optimally adjusted for length using a compression
fitting. In addition, the sensor tip is held against the separating can using a
spring to guarantee secure contact.
12 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Ceramic ZrO2Mg0 separating cans Safety through leak detection
Separating cans often break as a result of vibrations caused, for exam-ple, by
damaged bearings after they have been running dry, or by vibrations in the
system.
In the event of a rupture, there is a danger of the medium getting into the
motor through the motor casing, which must be avoided when explosive
substances are being pumped.
For your safety we can offer a leak monitoring sensor which detects any me-
dium emerging after a rupture of the separating can and immediately switches
off the pump or the system.
In addition, the sealed bracket temporarily prevent the medium from entering
the environment.
On request, we can also fit a pipe to the bracket to safely remove the pumped
Ceramic separating cans have two advantages: medium. The connector for the pipe is directly opposite the sensor.
Energy savings
Magnetic fields cause eddy currents within metal separating cans, increasing
the overall energy consumption of the pumps. Ceramic separating cans mean
there are no eddy currents, leading to significant energy savings.
The graph below shows the additional energy consumption of a metal separa-
ting can due to eddy currents. It shows the energy consumption in relation to
the length of the magnet (in 10 mm increments) and to the diameters.
In the case of the largest separating can diameter, energy consumption rises
to the power of three. 1
5 kW
1750 rpm MK 165
2 kW
1750 rpm MK 110
0 kW
20 mm 40 mm 60 mm 80 mm 100 mm 120 mm
The additional energy consumption found in magnetic couplings with metal separating
cans due to electrical eddy currents is completely eliminated by using ceramic separating
cans.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 13
Main dimensions
SK series
Connecting dimensions for SKG-LL, SKG-L0, SKG-LA and SKM Position of inlet and outlet nozzle
SKM
SKG
X a X
A B
h2
h1
ASK series
Connecting dimensions for ASKG and ASKM Position of outlet nozzle
X a X
A B
h2
h1
Flanges
Flanges in acc. with EN 1092 PN 40.
Flanges in acc. with DIN EN 1092-2, drilled in acc. with ANSI 150 lbs or 300 lbs on request.
14 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Simple and optimal configuration software
Perfect for production engineers and plant planners – liquid pump configuration with SPAIX
We make SPAIX available to our authorised custom- After consultation with Speck, users can also check
ers so they can configure and pre-select centrifu- currently installed pumps for which the plant pa-
gal and side channel pumps. rameters have changed: for example, after medium
changeover or new operating conditions.
The web-based software accesses a continuously
maintained database to offer a variety of selection Executed configurations can be saved as a project
parameters for design, sealing systems, hydraulic and exported as a PDF with one click.
systems, operating conditions and media. Users can
select either German or English as the language. When the order is received, Speck also checks
the customer's pre-selections to ensure that the
Configuration software by Speck - the perfect tool for Production engineers and plant planners can use project requirements have been satisfied.
planning new plants SPAIX to design new plants.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 15
Characteristic curves SK...20
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
4 8 12 US g.p.m. 4 8 12 US g.p.m.
Head H
Head H
m ft m ft
= No. of stages = No. of stages
550 240 800
160
500
700
140 450 200
600
120 400
160
350 500
100
300
120 400
80
250
60 200 300
80
150
40 200
100 40
20 100
50
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
3 4
5
2
3 4
1,5 2
3
2
1
2
1
0,5 1
1
0 0 0 0
m ft m ft
NPSH
NPSH
2,8 9 12
3,5
2,4 8
3 10
7
2
6 2,5 8
1,6
5 2
SK-20 / 50 Hz SK-20 / 60 Hz 6
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
16 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves SK...32
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
4 8 12 16 20 US g.p.m. 5 10 15 20 25 US g.p.m.
Head H
Head H
m ft m ft
= No. of stages = No. of stages
1000 450
1400
280 900 400
1200
240 800 350
700 1000
300
200
600
250 800
160
500
200
120 400 600
150
300
80 400
100
200
40 200
100 50
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
10
12 16
6 8
12
6 8
4
8
4
2 4
2 4
0 0 0 0
m ft m ft
NPSH
NPSH
1,8 6 8
2,4
1,6 7
5
2
1,4
6
1,2 4 1,6
5
1 SK-32 / 50 Hz SK-32 / 60 Hz
1 2 3 4 5 m3/h 1 2 3 4 5 6 m3/h
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 17
Characteristic curves SK...33
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
16 20 24 28 US g.p.m. 20 24 28 32 36 US g.p.m.
Head H
Head H
m ft m ft
240 = No. of stages = No. of stages
1100
320
700 1000
200
280 900
600
240 800
160
500
700
200
400 600
120
160
500
300
80 120 400
200 300
80
40 200
100 40
100
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
12 16
6 8
12
6 8
4
8
4
2 4
2 4
0 0 0 0
m ft m ft
NPSH
NPSH
8 11
2,4 3,2
10
7
2,8 9
2
6 8
2,4
1,6 7
SK-33 / 50 Hz 5 2 SK-33 / 60 Hz
4 5 6 7 m3/h 4 5 6 7 8 9 m3/h
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
18 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves SK...40
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
25 30 35 40 45 50 US g.p.m. 30 35 40 45 50 55 60 US g.p.m.
Head H
Head H
m ft m ft
= No. of stages = No. of stages 1100
320
700 1000
200
280 900
600
240 800
160
500
700
200
400 600
120
160
500
300
80 120 400
200 300
80
40 200
100 40
100
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
12
15 20
8
15
8 10
4 10
4 5
5
0 0 0 0
m ft m ft
NPSH
NPSH
3,2 14
10
4
2,8 9 12
3,5
2,4 8
3 10
7
2
SK-40 / 50 Hz 2,5 SK-40 / 60 Hz
6 8
6 8 10 m3/h 8 10 12 14 m3/h
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 19
Characteristic curves SK...50
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
40 50 60 70 80 US g.p.m. 50 60 70 80 90 100 US g.p.m.
Head H
Head H
m ft m ft
= No. of stages = No. of stages
360 1200
240 800
1100
320
700 1000
200
280 900
600
240 800
160
500
700
200
400 600
120
160
500
300
80 120 400
200 300
80
40 200
100 40
100
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
50
20
25
30 40
15 20
30
15 20
10
20
10
5 10
5 10
0 0 0 0
m ft m ft
NPSH
NPSH
4 13
12 5
3,6 16
11 4,5
3,2 14
10
4
2,8 9 12
3,5
SK-50 / 50 Hz 8 SK-50 / 60 Hz
2,4
10 12 14 16 18 20 m3/h 12 14 16 18 20 22 24 m3/h
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
20 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves SK...65
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
60 80 100 120 140 US g.p.m. 80 100 120 140 160 US g.p.m.
Head H
Head H
m ft m ft
= No. of stages = No. of stages 1400
280 400
900
1200
240 800 350
700 1000
300
200
600
250 800
160
500
200
400 600
120
150
300
80 400
100
200
40 200
100 50
0 0 0 0
Shaft power P2
Shaft power P2
kW hp kW hp
60 80
40
60 80
30 40
40
20
20 40
10 20
0 0 0 0
m ft m ft
NPSH
NPSH
5 22
16 6,5
4,5 20
6
14
4 5,5 18
12 5
16
3,5 SK-65 / 50 Hz SK-65 / 60 Hz
4,5
16 20 24 28 32 m3/h 20 25 30 35 40 m3/h
Capacity Q Capacity Q
Test conditions
The characteristic curves apply to the delivery of water with a temperature of
20 °C at nominal speed.
Tolerances
Flow rate ± 10 %, total head ± 10 %, power requirement + 10 %
Deviating properties of the media to be pumped affect the characteristic
curves.
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 21
Characteristic curves ASK...20
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
2 4 6 8 10 12 US g.p.m. 4 8 12 US g.p.m.
H m ft m ft
H
Head
Head
180 = No. of stages = No. of stages
550 240 800
160
500
700
140 450 200
600
120 400
350 160
500
100
300
120 400
80
250
60 200 300
80
150
40 200
100 40
20 100
50
0 0 0 0
P2 kW hp kW hp P2
2
Shaft power
Shaft power
4
2
1 2
1 2
0 0 0 0
NPSH m ft m ft NPSH
5,5
4
1,2 1,6
5
1,1 3,6
1,4
1 4,5
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,15 0,5 0,22
0,7
0,14
0,45 0,2 0,65
0,13
ASK-20 / 50 Hz 0,18 ASK-20 / 60 Hz 0,6
0,12 0,4
Capacity Q Capacity Q
22 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves ASK...32
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
4 8 12 16 20 US g.p.m. 5 10 15 20 25 US g.p.m.
H m ft m ft
H
Head
Head
= No. of stages = No. of stages
1000 450
1400
280 400
900
1200
240 800 350
700 1000
200 300
600
250 800
160
500
200
400 600
120
150
300
80 400
100
200
40 200
100 50
0 0 0 0
P2 kW hp kW hp P2
8 15
Shaft power
Shaft power
10
4 10
4 5
5
0 0 0 0
NPSH m ft m ft NPSH
1,1 1,5
3,6
4,8
1,4
1 4,4
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,64
0,28
0,19 0,9
0,6
0,18 0,26 0,85
0,17 ASK-32 / 50 Hz 0,56 ASK-32 / 60 Hz
0,8
1 2 3 4 5 m3/h 1 2 3 4 5 6 m3/h
Capacity Q Capacity Q
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 23
Characteristic curves ASK...33
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
16 20 24 28 32US g.p.m. 20 25 30 35 US g.p.m.
H m ft m ft
H
Head
Head
= No. of stages = No. of stages 1100
320
700 1000
200
280
900
600
240 800
160
500
700
200
400 600
120
160
500
300
80 120 400
200 300
80
40 200
100 40
100
0 0 0 0
P2 kW hp kW hp P2
Shaft power
Shaft power
8 10
4
4
4 5
0 0 0 0
NPSH m ft m ft NPSH
1,6
5
1,1
3,5
1,4 4,5
1
0,9 3 4
1,2
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,32
0,7 1
0,2
0,28 0,9
0,6
ASK-33 / 50 Hz ASK-33 / 60 Hz
0,24 0,8
3 4 5 6 7 m3/h 4 5 6 7 8 9 m3/h
Capacity Q Capacity Q
24 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves ASK...40
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
25 30 35 40 45 50 US g.p.m. 30 35 40 45 50 55 60 US g.p.m.
H m ft m ft
H
Head
Head
= No. of stages = No. of stages 1200
800 360
240
1100
320
700 1000
200
280 900
600
240 800
160
500
700
200
400 600
120
160
500
300
80 120 400
200 300
80
40 200
100 40
100
0 0 0 0
P2 kW hp kW hp P2
Shaft power
Shaft power
10
20
10
5 10
5 10
0 0 0 0
NPSH m ft m ft NPSH
1,1 3,6 1,5
1,4
1 4,5
3,2 1,3
0,9 1,2 4
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,65
1,4
0,6 2
0,4
0,55 1,8
1,2
0,35 ASK-40 / 50 Hz ASK-40 / 60 Hz
0,5
6 8 10 12 m3/h 8 10 12 14 m3/h
Capacity Q Capacity Q
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 25
Characteristic curves ASK...50
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
40 50 60 70 80 US g.p.m. 50 60 70 80 90 100 US g.p.m.
H m ft m ft
H
Head
Head
= No. of stages = No. of stages 1400
280 900 400
1200
240 800 350
700 1000
300
200
600
250 800
160
500
200
120 400 600
150
300
80 400
100
200
40 200
100 50
0 0 0 0
P2 kW hp kW hp P2
20
Shaft power
Shaft power
40
20
20
10 20
10
NPSH m ft m ft NPSH
4 5,5
1,2 1,6
5
1,1
3,5
1,4 4,5
1
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,55 1,8 0,8
0,5 2,4
1,6 0,7
0,45 ASK-50 / 50 Hz ASK-50 / 60 Hz
1,4
10 12 14 16 18 m3/h 12 14 16 18 20 22 24 m3/h
Capacity Q Capacity Q
26 www.speck.de Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 05/2018 | 1096.1324
Characteristic curves ASK...65
50 Hz – 1450 min-1
60 Hz – 1750 min-1
Capacity Q Capacity Q
60 80 100 120 140 US g.p.m. 80 100 120 140 160 US g.p.m.
H m ft m ft
H
Head
Head
= No. of stages = No. of stages
1400
280 400
900
1200
240 800 350
700 1000
200 300
600
250 800
160
500
200
400 600
120
150
300
80 400
100
200
40 200
100 50
0 0 0 0
P2 kW hp kW hp P2
40
Shaft power
Shaft power
80
40
40
20
20 40
0 0 0 0
NPSH m ft m ft NPSH
1,5
4,8 2 6,5
1,4
4,4 6
1,8
1,3
Hsmin m ft m ft Hsmin
Minimum
suction head
Minimum
suction head
0,75 1,1 3,6
2,4
0,7
1
2,2 3,2
0,65 ASK-65 / 50 Hz ASK-65 / 60 Hz
16 20 24 28 32 m3/h 20 25 30 35 40 m3/h
Capacity Q Capacity Q
05/2018 | 1096.1324 Side channel pumps – SK and ASK series | Subject to technical modifications and errors. 27
Representations
Produktion / Production
Vertrieb / Sales
International E Spain MAL Malaysia ROK Corea
Service / Service Speck Pumpen Subsidiary Leesonmech J.C. International Inc.
A Austria SPECK BOMBAS INDUSTRIALES, Engineering ( M ) Sdn. Bhd. 2F, Bikeum Bldg. 108,
S.L.U. No. 18 Jalan 18, Taman Sri Kluang, Yanghwa-Ro, Mapo-Gu,
Tuma Pumpensysteme GmbH Trafalgar, 53 despacho 6 86000 Kluang, Johor 121-893 Seoul
Speck Pumpen Eitnergasse 12 Centro de Negocios CNAF T: +607 777 105 5 T: +82 232 628 00
Walter Speck GmbH & Co. KG 1230 Wien 46023 Valencia F: +607 777 106 6 F: +82 232 569 09
T: +43 191 493 40 T: +34 963 811 094 sales@leesonmech.com jylee@jcint.co.kr
Speck Pumpen F: +43 191 414 46
Systemtechnik GmbH F: +34 963 811 096 www.leesonmech.com www.jcint.co.kr
contact@tumapumpen.at M: +34 618 376 241
Speck Pumpen www.tumapumpen.at ventas@speckbombas.es RO Romania
Vakuumtechnik GmbH www.speck.de N Norway
S.C. Gimsid S.R.L.
Regensburger Ring 6 – 8, 91154 Roth AUS Australia PG Flow Solutions AS Str. Arcului nr. 9, Arp.2
T: +49 9171 809 0 Speck Pumpen Subsidiary P.O.Box 154, 1378 Nesbru
F: +49 9171 809 10 Speck Industries Pty Ltd.
F France Nye Vakaas Vei 14
021031 Bucuresti
T: +40 21 2118701
info@speck.de Unit 2 Speck Pumpen Subsidiary 1395 Hvalstad
www.speck.de F: +40 21 2102675
6 Glory Road Speck Pompes Industries S.A. T: +47 667 756 00 gimsid@gimsid.ro
Gnangara WA 6077 Z.I. Parc d’Activités du Ried F: +47 667 756 01 www.gimsid.ro
T: 1300 207 380 4, rue de l’Energie post@pg-flowsolutions.com
Speck Office Nord T: +61 8 6201 1286 B.P. 227 www.pg-flowsolutions.com
Ingenieure Willy Wandrach GmbH sales@speckaustralia.com 67727 Hoerdt Cedex RUS Russia
Flurstraße 105 www.speckaustralia.com T: +33 3 88 68 26 60 NL Netherlands LLC Firm Kreoline
Yunosti str., 5/3
22549 Hamburg F: +33 3 88 68 16 86
info@speckpi.fr Centrifugal pumps / Moscow 111395
T: +49 40 398 624 0 Centrifugaalpompen
F: +49 40 398 624 28 B Belgium Speck Pompen Nederland B.V.
T: +7 495 737 321 4
info@speck-nord.de Heat transfer pumps / Pompes pour GB Great Britain Businesspark 7Poort
F: +7 495 769 844 0
M: +7 495 505 198 8
www.speck-nord.de fluid thermique Stationspoort 10
Speck ABC UK Ltd info@kreoline.ru
FLOWMOTION BVBA AreenA House 6902 KG Zevenaar www.kreoline.ru
Mergelweg 3 T: +31 316 331 757
Moston Road,
Speck Office Mitte 1730 Asse Elworth, Sandbach F: +31 316 528 618
Grotrian-Steinweg-Str. 1c T: +32 2 309 67 13 Cheshire CW11 3HL info@speck.nl S Sweden
38112 Braunschweig F: +32 2 309 69 13 T: +44 844 764 063 2 www.speck.nl Hugo Tillquist AB
T: +49 531 23 000 90 info@flowmotion.be F: +44 844 764 063 4 P.O.Box 1120
info@speck-mitte.de www.flowmotion.be admin@speck-abc.com Vacuum pumps / Vacuümpompen 16422 Kista
www.speck-mitte.de www.speck-abc.com DOVAC B.V. T: +46 859 463 200
SPECK - Pompen Belgie N.V. Meer en Duin 228 F: +46 875 136 95
Bierweg 24 2163 HD Lisse info@tillquist.com
Speck Office West 9880 Aalter GR Greece T: +31 252 423 363 www.tillquist.com
Robert-Koch-Straße 22 T: +32 937 530 39 SPECK Hellas F: +31 252 417 946
40764 Langenfeld Salaminos St. 54
T: +49 2173 914 560
F: +32 932 500 17
info@speckpompen.be 17676 Kallithea
info@dovac.nl
www.dovac.nl
SK Slovakian Republic
info@speck-west.de www.speckpompen.be T: +30 210 956 500 6 Czech Republic (CZ)
www.speck-west.de F: +30 210 957 747 3 Heat transfer pumps / Pompes pour
BG Bulgaria grecha@speckhellas.gr fluid thermique SLO Slovenia
FLOWMOTION BVBA
EVROTECH OOD SLOTEH Branko Gabric s.p.
Speck Office Ost Mergelweg 3 Zagrebška cesta 20
Dahlener Str. 7a 54 A, Manastirska Str. I Italy 1730 Asse 2000 Maribor
04889 Belgern-Schildau 1111 Sofia T: +32 2 309 67 13
T: +359 2 971 32 73 Centrifugal pumps / Pompe centrifughe T: +38 624 614 460
T: +49 34221 557 812 Speck Industries S.r.l F: +32 2 309 69 13 F: +38 624 614 465
info@speck-ost.de F: +359 2 971 22 88 info@flowmotion.be
office@evrotech.com Via Garibaldi, 53 branko.gabric@amis.net
www.speck-ost.de 20010 Canegrate (MI) www.flowmotion.be www.sloteh.si
www.evrotech.com
T: +39 0331 405 805
M: +39 339 16 59 440
Speck Office Südwest NZ New Zealand SGP Singapore
Frankenstr. 9 CH Switzerland info@speckindustries.it
www.speckindustries.it Speck Pumpen Subsidiary Malaysia (MAL)
67227 Frankenthal Speck Pumpen Subsidiary Speck Industries Pty Ltd.
T: +49 6233 354 80 57
info@speck-suedwest.de
Speck Pumpen Industrie GmbH
Bürglenweg 4
Vacuum pumps / Pompe per vuoto Unit 2 T Thailand
Rio Nanta S.r.l. 6 Glory Road
www.speck-suedwest.de 8854 Galgenen Via Mauro Macchi, 42 Speck Pumpen Subsidiary
Gnangara WA 6077 Pump Systems Flux &
T: +41 554 425 094 20124 Milano T: +61 8 6201 1286
F: +41 554 425 094 T. +39 028 940 642 1 Speck Co. Ltd.
sales@speckaustralia.com 181/4 Soi Anamai
IVT-Pumpen GmbH info@speckswitzerland.com F: +39 028 323 913 www.speckaustralia.com
Zum Wischfeld 1 A www.speckswitzerland.com M: +39 339 658 781 6 Srinakarin Road
Suanluang Bangkok 10250
31749 Auetal
T: +49 5752 929 597 HänyTec AG
rionanta@rionanta.it
www.rionanta.it
P Portugal T: +662 320 256 7
F: +49 5752 929 599 Pumpen-Prozesse-Service Ultra Controlo F: +662 322 248 6
Lättfeld 2 Projectos Industriais, Lda. thienchai@fluxspeck.com
info@ivt-pumpen.de
www.ivt-pumpen.de 6142 Gettnau IL Israel Quinta Lavi – Armazém 8 www.fluxspeck.com
T: +41 62 544 33 00 Small pumps / Abrunheira
F: +41 62 544 33 10 heat transfer pumps 27 10 - 089 Sintra TR Turkey
contact@haenytec.ch Ringel Brothers (1973) Ltd. T: +351 219 154 350
FSE Fluid Systems Erfurt 134 Hertzel St. F: +351 219 259 002
Speck Pompa
Poeler Weg 6 www.haenytec.ch San. ve Tic. Ltd. Sti.
P.O. Box 5148 info@ultra-controlo.com
99085 Erfurt Tel-Aviv 66555 Girne Mah., Kücükyali Is Merkezi
T: +49 361 550 715 0 MEYER ARMATUREN PUMPEN GMBH www.ultra-controlo.com B Blok No.12 Maltepe
Rigackerstrasse 19 T: +972 368 255 05
F: +49 361 550 715 19 34852 Istanbul
info@fluidsystems.org 5610 Wohlen F: +972 368 220 41
M: +972 544 623 095
PL Poland T: +90 216 375 750 5
www.fluidsystems.org T: + 41 56 622 77 33 F: +90 216 375 753 3
F: + 41 56 622 77 60 mringel@ringel-bros.co.il Krupinski Pompy Spółka z
www.ringel-bros.co.il Ograniczona Odpowiedzialnoscia Sp.K. M: +(90) 532 293 010 4
Vacuum pumps info@meyer-armaturen.ch speck@speckpompa.com.tr
www.meyer-armaturen.ch ul. Przymiarki 4A
Arpuma GmbH 31-764 Krakow www.speckpompa.com.tr
Ottostrasse 10 IND India T + F: +48 126 455 684
50170 Kerpen CN China Flux Pumps India Pvt. Ltd. biuro@krupinski.krakow.pl USA USA
T: +49 2273 953 300 0 Speck Pumpen Subsidiary 427/A-2, Gultekdi Industrial Estate www.krupinski.krakow.pl
F: +49 2273 953 300 20 Near Prabhat Printing Press Speck Pumpen Subsidiary
Jiashan SPECK PUMPS Speck Industries LP
info@arpuma.de Systemtechnik Ltd. Pune – 411 047, Maharashtra
www.arpuma.de No. 57, Hong Qiao Rd., Huimin Street T: +91 020 2427 1023 RC Taiwan 301 Veterans Blvd
Rutherford
No. 4 Economical Developing Zone, F: +91 020 2427 0689 Speck Pumpen Subsidiary
M: +91 98504 03114 NJ 07070
314100 Jiashan Xian, Speck Pumps T: +1 201 569 3114
Zhejiang Province kiran.kadam@flux-pumps.in Technology Taiwan Ltd.
www.flux-pumps.in F: +1 201 569 9607
T: +86 573 847 312 98 2Fl., no. 153, Sec. 2 info@speckamerica.com
F: +86 573 847 312 88 Datong Rd., Xizhi District www.speckamerica.com
steveche@speck-pumps.cn J Japan New Taipei City
www.speck-pumps.cn T: +886 286 926 220
ZA
05/2018 | 1096.1324