ZD402Power Supply Cabinet 7 + Activation of, slight touch button, press the button by manual o stop activation. ‘+ Battery on sight touch button, press the button by manual to stat activation. — I batter terminals direct connect to load, this button no effect. + Battery of, sight touch button, prass the Butlon by manual o stat activation. - If battery terminals dlect connect to load, this button no effect. + Activation button, press the button one time to start the activation, charge and activation indicator on, battery discharge to load and discharge ‘resistor, press activation off button to stop activation, otherwise main power automatic complete baltry activation, + Battery button, in the first use before battery has input, press batty on button, + Product stat to operate when connect to main power, itis constant voltage and constant curent charging for battery. When battery charging finish, power automatic len to floating charge, power supply floating valtage al this moment and current supply ballary normal charge and discharge. UPSG1 UPS Signal control board G1 veto foot G1 B $ gg x o8e 282 082 o82 EF UPS Signal control board instruction: ‘This contol board work with MEP charging module, achieve the switch of input and output conta signal, supplementary achieve battery low voltage inspection function(Product MBP charging module power low voltage inspection function isnot stable cause by large instant drive output Current which lead to lead acd battery voltage was instant decreased,use this control board to supplementary achiove .) + POK: AC No-voltage alarm, dry contact is used to output to PLC, indicator on when power is normal, indicator off when power is failure. ‘+ HOK: Activation output, when activation on, HOK relay action, green inicator on, atthe same time main power is disconnected, discharge by battery + VLt: Battery low voltage alarm, dry contact is used to output to PLC, indicator on when battery is normal, indicator off when battery is low voltage (battery low voltage alarm point is 45.5V) + VL2: Battery low voltage alarm, dry contac is used to stop battery output, prevent batlery over-discharge, indicator on when battery is normal indicator off when battery is lw voltage (baler low volage alarm point i 45.5V) «HK: Remote control activation input, 24VDC high level is supplied by PLC, duration isnot less than 0.58. Remark 1. When battery voltage is lowor than 45.SV for more than 3 seconds, control board wil output low voltage alarm, charge the battery in time to ‘prevent battery overdischarge damage; while baer is charging, ow voltage alarm will be cleared after battery voltage is higher than4 SV for more than 3 seconds. 2. When battery voltage continuous lower 26V, contol board will automatic turn off, prevent battery further damage; control board wil return to hhave power supply when battery voltage is more than 45V. Heating module 4 » we Heater ‘Temperature controler as

You might also like