RURAL ELECTRIFICATION AGENCY PRE-COMMISSIONING REPORT Dh pe iy ik TOT 3A: CONSTRUCTION OF 33KV OVERHEAD LINE FROM THE PROJECT NAME, EXISTING 132KV OPUYO-MOROTO LINE TOTALLING TO 465.06KM AND | 338.89KM OF LV OVERHEAD USING PRE-STRESSED COCRETE POLES- | AND INSTALLATION 5400 LAST MILE CONNECTION.REA-IDBILWRKS/15- 1600299 EMPLOYER RURAL ELECTRIFICATION AGENCY ‘CONSULTANT ‘COLENCO CONSULTING NIGERIA.LTD. re ‘CONTRACTOR ‘CEYLEX ENGINEERING (PVT) LTD. ‘OPERATOR ‘UMEME LTD LOCATION Scheme 16 CPabona Tr er) "TRANSFORMER PARTICULARS ‘COMMENTS MAKE LTL SRI LANKA a TYPE (OIL IMMERESED TRANSFORMER RATING (KVA) Boku & SERIAL NUMBER Tod £ 244g YEAR OF MANUFACTURE | 9.0/4 ‘% IMPEDANCE, Asl4 NUMBER OF PHASES 3 RATED VOLTAGE PRIMARY (kV) SECONDARY (V) a3 ASS ‘OIL LEVEL Max ‘TEST RESULTS ‘COMMENTS INSULATION RESISTANCE | HV-LV(MOQ) | HV-E_ (M|LV-E (WO) ‘TEST 2) 2718 GA | 221 aa! oh SURGE ARRESTORS Ro) YMo) [Boro ow cs a EARTH RESISTANCE TEST | AV @) Lv @), 212 Bie NO LOAD OUTPUT PHASE-PHASE(V) _| PHASE-NEUTRAL (V) VOLTAGE (46%) RY A26v RN 936v RE 42eu YN 93av YB 42av BN FINAL TAP POSITION FUSE RATING (A) PRIMARY | SECONDARY(C cry - 5A. £3A WITNESSEDBY [CONTRACTOR | REA aa OPERATOR | Bias. FT. @_ Ushoun ka at Date; 14 12020 ‘Te Brpe lily ink RURAL ELECTRIFICATION AGENCY PRE-COMMISSIONING REPORT LOT 3A: CONSTRUCTION OF 33KV OVERHEAD LINE FROM THE PROJECT NAME EXISTING 132KV OPUYO-MOROTO LINE TOTALLING TO 465.06KM AND 338.89KM OF LV OVERHEAD USING PRE-STRESSED COCRETE POLES ‘AND INSTALLATION 5400 LAST MILE CONNECTION.REA-IDBI/WRKS/15- 1600299 EMPLOYER RURAL ELECTRIFICATION AGENCY ‘CONSULTANT ‘COLENCO CONSULTING NIGERIA.LTD CONTRACTOR ‘CEYLEX ENGINEERING (PVT) LTD. ‘OPERATOR UMEME LTD LOCATION acemat id= CNaeallgn yr. Canteen 0! "TRANSFORMER PARTICULARS ‘COMMENTS MAKE LL SRI LANKA TYPE ‘OIL IMMERESED TRANSFORMER RATING (kVA) Bokve ‘SERIAL NUMBER TOO 1p_44qe YEAR OF MANUFACTURE, 20g % IMPEDANCE Beth NUMBER OF PHASES 3 RATED VOLTAGE. PRIMARY (kV) SECONDARY (V) ZS AS? ‘On LEVEL Max i [ TEST RESULTS ‘COMMENTS INSULATION RESISTANCE | HV-LV (MQ) HV-E (M | LV-E(MQ) ‘TEST 9) 2.65 Ga | 238eal hk ‘SURGE ARRESTORS RM™O) Yo) | B™o) XL ak ol EARTH RESISTANCE TEST | HV (Q) Lv) be 7 2.1 SL NO LOAD OUTPUT PHASE-PHASE (V) PHASE-NEUTRAL (V) VOLTAGE (6%) RY Apt v_ [RN Q40U RB A224 V YN 288 0 YE 4pev [BN 240v FINAL TAP POSITION FUSE RATING (A) PRIMARY | SECONDARY(C | SECONDARY cm ccr) BA G3A ban z WHINESSEDBY | CONTRACTOR ~_ [CONSULTANT OPERATOR Name TG Ushemle nS Designation BE ann signature ates: Date 4latao290

You might also like