• Radiation protection cabinet, complete with charge opening, service door, and dual safety switch
SEIFERT DP 150.10
• Manipulator Radioscopic Inspection System
• ERESCO 160 MFR3 X-ray unit
• VISTALUX 7-CCD X-ray image intensifier system (incl. 7“ image intensifier and 44 cm (17“) b/w monitor)
• System control electronics
• Control console with integrated ERESCO MF3 digital control
• Monitor support
• 1 set connecting cables
Options
• Water-cooled version of ERESCO MFR3 for high temperature environments
• ISOVOLT 160 HS X-ray unit with following choice of X-ray tube:
- ISOVOLT 160 M2/0.4-0.4 dual focal spot X-ray tube, each 1.00 mm
(EN 12543) [0.4/0.4 (IEC 336)] capable of 4 mA at 160 kV
- ISOVOLT 160 MM2/0.2 single focal spot X-ray tube of < 0.5 mm (EN 12543)
[0.2 (IEC336)] capable of 2 mA at 160 kV
Application Features
The DP 150.10 is a compact design self- • 5 Axis manipulator
The DP 150.10 is designed to meet or exceed domestic and interational contained real-time X-ray unit suitable for • Motorized in 4 axes with joy stick control
standards and regulations, including, but not limited to: the inspection of small parts. • Maximum workload 10 kg / 22 lbs
• Inspection diameter up to 300 mm / 11.8” *)
• ISO 9001 • CFR 1020.40 • DIN EN 954-1
The DP 150.10 inspection system satis- • Inspection height up to 300 mm / 11.8”
• UVV • CE Konformität • DIN EN 60529 / IEC 529
fies by good basic-functionality, low floor • ± 30° tilt capability
• VBG 4 • VDE 0100 • DIN 54113
space and easy operation. The excellent • Hinged access door for ease of loading
• German X-Ray Regulations RöV • DIN EN 60204 (VDE 0113)
in their updated version price-performance ratio of this turnkey • Lead glass viewing window (300 x 300 mm)
system for basic inspection tasks makes it • Mobile control console
an ideal machine for process control and • Compact design to minimize floor space
small parts checking. Transportation and • Easy installation or relocation
installation at the production site is easily • Minimal maintenance required
done using standard lifting gear. • Manufactured under ISO 9001 certified Quality Management System
*) The penetrable inspection volume varies with the total material thickness and material density
GEInspectionTechnologies.com
We reserve the right to technical modifications without prior notice. ©2004 General Electric Company. All rights reserved.
GEIT-30088GB (6/04)
GE Inspection Technologies Xray
710 / 27.9"
standards including DIN, EN 954-1, CFR
1020.40. The five (5) axes manipulator consists of The DP 150.10 features the VISTALUX
1400 / 55.1"
four (4) motorized axes with fixed speed imaging system, which includes a high Rx
Tz
1860 / 73.2"
Its compact design and built in safety setting and one manually adjustable axis resolution X-ray image intensifier coupled
features allow for placement nearly any- (geometrical magnification). The motor- to a CCD camera with wide dynamic
1070 / 42.1"
where within the manufacturing process ized axes are controlled by joysticks con- range. Display is by a 44 cm / 17” high-
Ty
by forklift truck. veniently placed on the control console. resolution b/w monitor, which provides
superior imaging capabilities.
The DP 150.10 features sturdy steel/ An ERESCO 160 MFR3 air-cooled X-ray
lead/steel construction. The loading door unit with small focal spot of 1.0 mm
is large enough to allow easy access for according to standard EN12543 (0.5
Technical Data
960 / 37.8"
300 / 11.8"
Workpiece
Maximum dimensions 300 x 300 mm / 11.8” x 11.8” (diameter x height) *)
Maximum weight 10 kg / 22 lbs
Cabinet
Dimensions See drawing/layout plan
Weight Approximately 1550 kg / 3400 lbs
Lead glass window 300 x 300 mm / 11.8” x 11.8”
Maintenance door 1010 x 1260 mm / 39.8 x 49.6 ”
2250 / 88.6"
Control console
Dimensions 500 x 600 x 320 mm / 19.7” x 23.6” x 12.6 “ (W x D x H)
Weight Approximately 70 kg / 154 lbs
600 / 23.6"
840 / 33"
X-ray unit (standard)
Tube voltage 5 kV to 160 kV, adjustable in 1 kV increments
Tube current 0.5 mA to 10 mA, adjustable in 1 kV increments
Focal spot size EN 12 543 : 1.0 mm (corresponds to 0.5 per IEC 336)
Inherent filtration 0.8 mm Be
Power requirements
Supply voltage 3 NPE 400/230 V ± 10%, 50/60 Hz
Layout DP 150.10
3-phase, grounded neutral, star connected system
(optional 3-phase isolation transformer)
Supply power approx. 2 kVA
Power supply fuse (customer-provided) max. 25 A