You are on page 1of 2
DWG Number 248A4158 RavK Released 6/12/2014 Page So! aE ma ar A 2asaatsa 4 v FABLE | GENERAL TORQUE REQUIREMENTS FOR NONSTRUCTURAL FLANGES 1 Nominal Head Marking™ Head Marking Head Marking’ Bolt Diameter ‘Six Radial Lines, LCR, 87, HB7 AZA, A2B, BEM & Threads None ft. tbs. IN] ft. bs. Nm] ‘ft ibs [Nm 632 08-11-13] 08-11-13) 02-0.9 103-121 10-32 2-312.7-40] 2-312.7-4.0] 15-2 (2.0-2.71 25-20 5-6 168-6. 5-616.8-8.1) 4-5 15.4651 3125-18 9 -11(12.2-14.91 3-11112.2-14.91 B-10 [10.8-13.6] 375-16 17-21(23.0-28.5] 14-17 [19.0-2301 1-14 [14.9-12.0] 50-13 52-56 [71-76l 43-45 (58-6) 36-37 [49-50] E251 98-105 [153-142] 81-85 [NO-115] 8-69 [92-94] 750-10, Wei-I78 (218-241, 134-144 [182-195] I-A? [151-159] 875-9 252-277 [342-376] _| 209-224 (283-304]_| 174-182 [236-2471 7.008 366-407 [496-52] | 302-329 [410-446] | 251-267 [340-3621 125-6 532-606 [7el-8221_| 438-490 1594-664] | 362-397 [491-538] c 425-8 699-804[948-1090]_| 573-650 [777-8811 ‘472-527 [640-7151 1375-6 950-1102 [1288-1494] | 778-891 [1055-1208] | 440-722 [848-979] 1508 1201-1400[1629-1676) | 982-1132 [1332-15351 | 607-918 [1094-1245] 1. Material: C1A3A, C1A5 2, Material’ 85041255, BSFSB3, C1A2A, C1AZB, C1A3A, C1A3B, C1A3C, C1A3D, C1ASC1, CiASD1 3. Material: C1F18A1, C1F19A1, C1F19A2, C2F9A, C2F10B TEER EESTROCOIN | SHE | CHECODE BENE GE Power Generation ScrENECTAON.NY | DABS Dewi’ G. LARK 72623 SECTION ¢ ED TUNE SO, 1572 a eT GE Proprietary Information - Class Il Inoral) US EAR - NLR. WG Number 26884168 RevK Released 6122014 Page 6of7 eae er ¥ A 2asasts8 s|u [FaBLé 2 HORIZONTAL AND VERTICAL STRUCTURAL FLANGE TOROUE REQUIREMENTS (Sane BOLT DIAMETER ‘APPLIED TORQUE & THREADS PER INCH FT LBF [Nm] 78-10 208-229[282-Si] 100-8 472-620 [640-705] 125-8 318-1010 1245-1370] 150-8 1634-1797 [2216-2437] 175-8 3370-3708 [4570-5028] 2.00-6 6372-7010 [8640-9505] 225-6 ‘9205-10125 (12482-13728) 250-8 12771-14048 [17317-19047] 275-8 17129-16933 | 28227-25670) 3,00-8 22403-24761 | 30378-33572] ORS TABLE 3-HORIZONTAL AND VERTICAL STRUCTURALFLANGE TORQUE REQUIREMENTS ((376 \iPo]) BOLT DIAMETER APPLIED TORQUE & THREADS PER INCH FT LBF [Nm] 75-10 139-163 [168-2071 100-8 315-346 [427-4691 125-6 612-674| 830-914] 150-8 1989-1198 [1477-1624] 175-8 2247-2472 [3047-3352] 2.00-8 4248-4673 [5760-6336] 225-6 6136-6750 [6320-9152] 250-8 514-0866 [11545-12699] 275-8 11420-12620 [15486-17113] 3.00-8 74936-16608 [20253-22382] NoTES: |. MATERIALS TYPICALLY USED ON STRUCTURAL FLANGE APPLICATIONS ARE B5F5 AND BSOAI5. 2. APPLICATION OF ANTISEIZE (ITEM |) PER PARAGRAPH 12 IS REQUIRED DURING EVERY ASSEMBLY CYCLE TO ACHIEVE THE PROPER PRELOAD WHEN USING THE TORQUE VALUES SPECIFIED ABOVE, ‘GENERAL ELECTING COWPANY | SIZE | AGE CODE [BENS GB _ SE Power Generation Sev 24844158 [Dan TKOSTER 95/09/26 SOC SECTION 1 ‘seus T.KOSTER 95/10/13 soaLe ewer GE Proprietary Information - Class I (Internal) US EAR - NLR.

You might also like