engine or by 3 phase electric source and can be used as a replacement to Thermo king or Carrier
similar systems
GND
85
5 A fuse
85
86
System run selection by Diesel engine auxiliary relay
RR1
85
30 30 30
SRR Diesel engine run delay bypass timer A1
RR
87a 87 87
ERBPT
A2
WTS
Diesel engine high temperature relay 86
EHTR
85
EHTR
Engine high temperature warning light EH
87a
T
30
HPS
5 A fuse Refrigerant gas high pressure relay 86
HPR
85
HPR
Refrigerant gas high pressure warning light HP 87a
T
30
LP
Refrigerant gas low pressure relay 86
LPR
85
LPT
30
5 A fuse
Diesel engine continues
operation command switch OL
97 Electric motor overload warning Light OL
T
98
ECLL
OPSR
87a
5 A fuse
WIRE#6
Thermostat WIRE#7
TC
85
RR1 O/L
30 95 Stand by electric power relay 86
MCR
87a 96 85
15
Diesel engine restarting timer A1
ERBPT
ERDT
16 A2
TCR
30 GPHT
15 Diesel engine glow plugs operation relay A1
87a GPR
16 A2
ACR OPSR FT
30 30 15 Diesel engine starting relay 86
SSR
87 87a 16 85
ACR
A1
30 Diesel engine high speed delay timer HST
87a A2
Battery charger excitation feeding relay during Diesel engine operation 86
CHR
85
HST
15 Diesel engine high speed relay 86
SR
18 85
SENSE
Battery charger charging sensing relay 86
From alternator sense terminal ACR
85
86
20 A fuse OPS
Diesel engine low oil pressure relay
OPSR
85
SSR
30 Diesel engine starting motor starting solenoid
S
SS
87 GND
MC
13
14
EXC
30 CHR Battery charger excitation coil D-
87
30 GPR Diesel engine glow plugs
87
FSR Engine fuel solenoid
30
87
LT
15 Note 1 Compressor second stage loading solenoid
18
TC Defrost
Defrost relay 86
WIRE#11
DFR
85
Defrost solenoid
DFR
30
87
Note 2
Defrost damper
DD
DFR EFR
30 30 Note 2 Mechanical Evaporator clutch
EFC
87a 87
WIRE#10
WIRE#9
WIRE#8
WIRE#10
WIRE#9
WIRE#8
WIRE#6
WIRE#6
M 12VDC 12VDC
Electric motor
Note 1 Not all compressors have loading solenid valves and some of them have more than one
Note 2 Evaporator fan(s) operation technique differs from a manufacturer to an another and between a model and another within the
same manufacturer. Some these fans are electrically operated and some of them are mechanically shaft coupled ,however the
driving shaft coupling can be permanent or electrically engage able by an electric clutch to stop the fan during defrost period ,
for the permanently engaged shaft fan a damper gate is installed to close the discharged air path during defrost period
FT timer is of Asymmetric cycle type and it is programed to be ON for 10 seconds and OFF for 5 ON ON ON
seconds ( during its total run time a 3 engine starts attempts will achieved)
ECLL R P
Refrigerant gas Refrigerant gas Electric motor Engine low oil Battery Engine high
low pressure high pressure overload pressure charger fail temperature
warning light warning light warning Light warning light warning light warning light
0 Diesel engine
Stand by 2 1 Diesel engine Automatic ON/ 0 1 Diesel engine
FSR GPR SSR CHR SR ACR OPSR TCR power selection Thermost OFF selection continua run
selection
RELAY RELAY RELAY RELAY RELAY RELAY RELAY RELAY selection
-25.00
Stand by power or Diesel Diesel engine continua run selection keep the
engine operation selection engine running in its low speed once the
desired cooling temperature is achieved
Main panel equipment layout .Please not that shown timers can be
Front panel equipment layout
replaced by a single multi programmable times like UMT500ML