You are on page 1of 2

"IBC2003E.

xls" Program
Version 1.6

SEISMIC FORCE FOR COMPONENTS


ASCE 7-05 Specifications
For Architectural Components
Job Name: Subject: II
Job Number: Originator: Checker: III
IV
Input Data: ###
Occupancy Category = IV Seismic Use Group III ,IBC Table 1604.5 ###
Soil Site Class = B ###
A
Spectral Accel., SS = 0.100 B
Spectral Accel., S1 = 0.050 C
Average Roof Height, h = 3.000 m D
Height of attachment, z = 3.000 m E
Importance Factor, Ip = 1.50 ASCE 7-05 section 13.1.3 F
Component Weight, Wp = 1.00 ###
Component Type = 5a

Results:
2a
Site Coefficients: 2b
Fa = 1.000 ASCE 7-05 table 11.4-1 3a
Fv = 1.000 ASCE 7-05 table 11.4-2 3b
3c
Maximum Spectral Response Accelerations: 4a
SMS = 0.100 SMS = Fa*SS, ASCE 7-05 eq. 11.4-1 4b
SM1 = 0.050 SM1 = Fv*S1, ASCE 7-05 eq. 11.4-2 4c
5a
Design Spectral Response Accelerations for Short and 1-Second Periods : 5b
SDS = 0.067 SDS = 2*SMS/3, ASCE 7-05 eq. 11.4-3 6a
SD1 = 0.033 SD1 = 2*SM1/3, ASCE 7-05 eq. 11.4-4 7a
8a
Seismic Design Category: 9a
Category(for SDS) = A IBC Table 1616.3(1), page 326 9b
Category(for SD1) = A IBC Table 1616.3(2), page 326 10a
Use Category = A Most critical of either category case above controls 11a
12a
Amplification and Response Modification Factors: 12b
Amplification Factor, ap = 1.00 ASCE 7-05 table 13.5-1
Response Modifier, Rp = 2.50 ASCE 7-05 table 13.5-1

Component Seismic Force:


Fp = 0.05 Fp = (0.4*ap*SDS*Wp)*(1+2*z/h)/(Rp/Ip), Eqn. 13.3-1
Fp(max) = 0.16 Fp = 1.6*SDS*Ip*Wp, ASCE 7-05 Eqn. 13.3-2
Fp(min) = 0.03 Fp = 0.3*SDS*Ip*Wp, ASCE 7-05 Eqn. 13.3-3
Use: Fp = 0.05 Note: Fp is to be applied in both transverse and longitudinal
directions relative to seismic restraint.
Comments:

1 of 2 10/14/2020 12:49:54
"IBC2003E.xls" Program
Version 1.6

2 of 2 10/14/2020 12:49:54