You are on page 1of 2

Dear Sir,

The objective of this proposal is to toilet exhaust system . This system represents substantial savings for acquisition, operation and maintenance. Based on the
details provided by your BOQ .

Project: 4 BY OYO, CHANDIGARH.


SNo. Description Unit Qty Unit Rate Amount
1 toilet axhaust system fan
Supply installation, testing and commissioning of Tube Axial fan complete with GI. canopy &
Long casing (Motor should completely be accommodated inside the fan casing) in MS with
powder coated, Al impeller with adjustable blade angles, bird screen ,gravity louvers, fire
retardant flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction
motor (IE2) (F-class 3 phase electric supply complete with required hardware etc.. Thickness of
the casing shall not be less than: For Dia (300 to 650) mm . Outlet velocity of the fans 12M/S.

1.1 1000 cfm free flow (unit size with canopy ,wire mess bird screen and fan (450 x450 x1500 (l x w xh)). Nos 6 10550 63300
1.2 2000 cfm free flow (unit size with canopy,wire mess bird screen and fan (550x550 x1500 (l x w xh)) Nos 5 12800 64000
1.3 4000 CFM Free flow (unit size with canopy,wire mess bird screen and fan (650 x650 x1500 (l x w xh))
Nos 5 15650 78250
1.4 Supply installation, testing and commissioning of 2C x 1.5Sqmm control cable . RM 500 120 60000
1.5 Supply installation, testing and commissioning of power point for connect the cable to fan unit.
Nos. 16 280 4480

2.0 supply and installation of M.S. stand for axhoust unit fixing, testing and commisioning. nos. 16 3500 56000
0

3 Supply, Installation, Testing Balancing & Commissioning of G.S.S square/ rectangular ducting
complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as required
for toilet ventilation of following thickness. 0
i supply snd installation of g.i. fabricated pipe 24 G. for connect existing pipe to axhaust unit
connection. nos. 36 340 12240
0
4 electricle pannel with timer 0
1.1 supply and installation of electricle pannel for 6 no. of exhaust unit . nos. 1 60000 60000
1.2 supply and installation of electricle pannel for 10 no. of exhaust unit . nos. 1 80000 80000
0
5 parking ventilation system fan 0
1.1 existing fire damper connection NOS. 6 1800 10800
1.2 Supply , testing and commissioning of 2C x 1.5Sqmm control cable . RMTR. 250 120 30000
1.3 Supply , testing and commissioning of power point . NOS. 3 260 780
1.4 supply and installation of wire clamping and installation. LOT. 1 30000 30000
0
6.0 M.S. BIRD SCREEN 0
1.0 supply and installation of round flange 700 mm dia,50mm wire mess, nut bolt with powder
coating. NOS. 7 3500 24500

TOTAL AMOUNT ₹ 5,74,350.00