AIR FLOWANCE SYSTEM

EMAIL.-AIRFLOWANCESYSTEM@GMAIL.COM
ADDRESS.AIR FLOWANCE SYSTEM 14/4 BALI NAGAR MATHURA ROAD FARIDABAD 121002.

No.: AFS 21-22/106 Date: 02.12.2021


SUBJECT. TOILET EXHAUST SYSTEM
Project: 4 BY OYO, CHANDIGARH.
SNo. Description Unit Qty Unit Rate Amount

1 toilet axhaust system fan


Supply installation, testing and commissioning of Tube Axial fan complete with GI. canopy & Long casing (Motor should
completely be accommodated inside the fan casing) in MS with powder coated, Al impeller with adjustable blade angles, bird
screen ,gravity louvers, fire retardant flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor
(IE2) (F-class 3 phase electric supply complete with required hardware etc.. Thickness of the casing shall not be less than: For Dia
(300 to 650) mm . Outlet velocity of the fans 12M/S.
1.1 1000 cfm free flow (unit size with canopy ,wire mess bird screen and fan (450 x450 x1500 (l x w xh)). Nos 6 28000 168000
1.2 2000 cfm free flow (unit size with canopy,wire mess bird screen and fan (550x550 x1500 (l x w xh)) Nos 5 35000 175000
1.3 4000 CFM Free flow (unit size with canopy,wire mess bird screen and fan (650 x650 x1500 (l x w xh)) Nos 5 40000 200000
1.4 Supply installation, testing and commissioning of 2C x 1.5Sqmm control cable . RM 500 55 27500
1.5 Supply installation, testing and commissioning of power point for connect the cable to fan unit. Nos. 16 350 5600

2.0 supply and installation of M.S. stand for axhoust unit fixing, testing and commisioning. nos. 16 2000 32000
0

3 Supply, Installation, Testing Balancing & Commissioning of G.S.S square/ rectangular ducting complete with gaskets, elbows,
splitters, vanes, supports adjustable dampers, etc. as required for toilet ventilation of following thickness. 0
i supply snd installation of g.i. fabricated pipe 24 G. for connect existing pipe to axhaust unit connection. nos. 36 3600 129600
0
4 electricle pannel with timer 0
1.1 supply and installation of electricle pannel for 6 no. of exhaust unit . nos. 1 52000 52000
1.2 supply and installation of electricle pannel for 10 no. of exhaust unit . nos. 1 68000 68000
0
5 parking ventilation system fan 0
1.1 existing fire damper connection NOS. 6 200 1200
1.2 Supply , testing and commissioning of 2C x 1.5Sqmm control cable . RMTR. 250 55 13750
1.3 Supply , testing and commissioning of power point . NOS. 3 350 1050
1.4 supply and installation of wire clamping and installation. LOT. 1 2000 2000
0
6.0 M.S. BIRD SCREEN 0
1.0 supply and installation of round flange 700 mm dia,50mm wire mess, nut bolt with powder coating. NOS. 7 2200 15400

TOTAL AMOUNT 891100

NOTE- GST 18% EXTRA AND FREIGHT CHARGE EXTRA AS PER ACTUAL
Thanking you in anticipation.

Yours truly
FOR AIR FLOWANCE SYSTEM

MUKESH KUMAR

Mobile No. – 9818497231