You are on page 1of 1

3

7 ranges
0.001Ω to 10MΩ CROPICO PW5
3
Accuracy ±0.1%
of Full Scale PW5 Portable
Wheatstone Bridge

3
Resistance Measurement

Cable Fault Location


with Murray/Varley Loop Test
with Murray and The PW5 is a compact and completeley self contained Wheatstone
Varley Loop Tests bridge measuring only 240 x 190 x 110mm and weighing 1.5 kg.
This compact unit offers the resistance measuring solution

3
where size and portability is a major consideration. In addition
to the Wheatstone bridge measurements, the PW5 also
May be used as a
includes both Murray and Varley loop tests for cable fault
Decade Box Total
location.
Resistance
= 11,110 Ω
Resolution
=1Ω Size: 240 x 190 x 110mm Weight: 1.5 kg with batteries

Accuracy Measuring Arm Multiplying Ratios Accuracy


±0.05% 10 x 1000 Ω x 0.1, x 1, x 10 ±0.05%
±0.1% 10 x 100 Ω x 100, x 0.01 ±0.2%
±1% 10 x 10 Ω x 1000, x 0.001 ±0.2%
±2% 10 x 1 Ω M10, M100, M1000 ±0.1%

3
7 ranges
0.001Ω to 10MΩ CROPICO CF6
3
Accuracy ±0.1%
of Full Scale CF6 Wheatstone Bridge

3
This portable instrument is ruggedly constructed and housed in a robust
Cable Fault carrying case, designed to withstand the harshest of environments and
Location with ideally suited as a field portable instrument. The CF6 is a Wheatstone bridge
Murray/Varley, for the resistance measurement of all types of electrical conductors, and
Loop Tests includes both Murray and Varley loop test facilities for testing of cables.
The bridge is both accurate and easy to use for the many varied tests

3
which it accomodates.
May be used as
a Decade Box
10,110 Ω Size: 320 x 260 x 185mm Weight: 5.6 kgs with batteries
Total Resistance
Resolution
=1Ω

3
Built in Null
Detector &
Accuracy Measuring Arm Multiplying Ratios Accuracy
Batteries
±0.05% 9 x 1000 Ω x 0.1, x 1, x 10 ±0.05%
±0.1% 10 x 100 Ω x 100, x 0.01 ±0.1%
±1% 10 x 10 Ω x 1000, x 0.001 ±0.2%
±2% 10 x 1 Ω M10, M100, M1000 ±0.05%

12 CROPICO GIVE US A CALL : +44 (0)20 8684 4025 CROPICO

You might also like