Professional Documents
Culture Documents
Technical data
3/2 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
2 3 G 1/4 Flange 1 10 1200 35 – 0,24 1 8020745
1 3
1 3
1 3
*1) When ordering, please indicate solenoid, voltage and current (frequency).
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.01
26360, 80207 NAMUR
5/2 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
4 2 G 1/4 Flange 1 10 1200 35 – 0,55 2 2636045
4 2
513
513
513
513
5 11 3
5 3
G 1/4 Flange 1 10 1200 30 without 0,90 3 2636246
4 2
513
53 1 3
5/3 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
4 2 G 1/4 Flange 3 10 950 40 with 1,0 4 2636447
513
*1) When ordering, please indicate solenoid, voltage and current (frequency).
N/en 5.4.386.02 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Solenoid operators
Power consumption Rated current Ex-Protection Protection Temperature Electrical connection Weight Dimension Circuit Model
24 V d.c. 230 V a.c. 24 V d.c. 230 V a.c. (ATEX- class *7) Ambient/ No. diagram
(W) (VA) (mA) (mA) Category) Fluid (°C) (kg) No.
2,7 - 113 - - IP 65 with -25 ... +60 Connector 0,15 1 1 0242
connector *5) Fluid: max. 80 DIN EN 175301-803
Form A *6)
- 4,2 - - - IP 65 with -25 ... +60 Connector 0,16 1 1 0245
connector *5) Fluid: max. 80 DIN EN 175301-803
Form A *6)
2,7 - 331 - II3G Ex nA II T4 -20 ... +60 Connector 0,16 1 1 3215
II3D Ex tD A22 IP65 DIN EN 175301-803 Form A
T90°C included in delivery
- 5,9 - 26 - XP/DIP, Div. 1 u. 2 -20 ... +60 Flying leads 450 mm 0,5 8 5 3723
CI. I, Gr. A-D
CI. II, Gr. E-G
CI. III,
T3 (160°C) *4)
NEMA 4, 4X,
6, 6P, 7, 9
Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. *8) Suitable for outdoor installation
Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *10) IEC Ex Certificate of Conformity
*1) EG-Type-Examination-Certificate KEMA 02 ATEX 1347X Attention:
*2) EG-Type-Examination-Certificate KEMA 98 ATEX 4452 X The protection class for coil series 46xx is determined by the choice of
cable gland.
*3) EG-Type-Examination-Certificate PTB 02 ATEX 2085 X
Example: if an ATEX-certified cable gland is used that has Ex d type of
*4) CSA-LR 57643-6, FM Approval protection, the solenoid will have the protection class Ex dmb;
*5) Required connector: type 0570275 if a cable gland with Ex e type of proteciton is used, the solenoid will
*6) Connector cable gland not supplied, see table »Accessories« have protection class Ex emb.
*7) IP-Protection class according to EN60529
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.03
26360, 80207 NAMUR
Accessories
Cable gland
Protection class Ex e, Ex d
(ATEX),
Nickel plated brass
Page 10
Thread Cable Ø Material Protection class (ATEX) Model
M 20x1,5 5,0...8,0 mm Nickel plated brass II2GD Ex e 0588819
M 20x1,5 10...14 mm Nickel plated brass II2GD Ex d 0588851
1/2-14-NPT 7,5...11,9 mm Nickel plated brass II2GD Ex d 0588925
Accessories
Connector Silencer *1) Exhaust guard *2) Throttle control plate Flange plate Yoke
Form A
N/en 5.4.386.04 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Dimensions
Valves
1
14
5 18 3
2
12
1
141
0
1
3
G1/4
1
2
71
24
ø 19,5
ø 15,5
12
ø 5,5
3
12
M5
23
3
32 5
55 7 30 5
14
5 18 3
2
14
1
153
0
1
G1/4
3
2
24
ø 19,5
ø 15,5
12
ø 5,5
1
12
M5
24
4
35
35
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.05
26360, 80207 NAMUR
14
3 5 18 3
14
2
1
0
1
3
G1/4
5
2
24
ø 19,5
ø 15,5
102
12
ø 5,5
1
242
12
M5
24
4
3
51
12
32 5
55 7 30 5
5 18
4 3
2
14
132
1
0
3
G1/4
5
2
24
ø 19,5
ø 15,5
124
12
ø 5,5
~ 264
1
12
M5
24
4
3
62
N/en 5.4.386.06 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Dimensions
Solenoid operators
1 71 1
38
15,5
40,5
41,5
M16 X 1,5 12
29,5
28
18
2
5 6 107
40,5
64,5
91,5
27
41
82,5 M 20 x 1,5
89 42
54,5
33
19,5
63,5
73
7 70,5 2
8
1/2 - 14 NPT
41,5
40,5
20
3 59 84
63 2
33,5
43
56
26 4
29 43
122
1 Connector can be indexed by 4x90°
2 Ø 16 or 13 (with spacer tube)
3 M20 x 1,5 or 1/2 - 14 NPT
4 Flying leads AWG 18 (450 mm long)
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.07
26360, 80207 NAMUR
Circuit diagrams
1 4 5 6
2
24
2 3
3
N/en 5.4.386.08 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
19 25,5 M 5 (4x)
19
25,5
G 1/4
35
19
41
16
51
11,5
30
9,5
16
12 12 5,5
34,5 41
104
5,5
ø 9,5 19
ø 5,5 G 1/4
12
5
11
60°
29
19
12
10
ø9 27 21
ø 14,5
19,5
2x
15,5
65
45
32
M5
50
41
12
12
5 20
76 4
12
8
25
M5
7,5
B B
15,5
15,5
A A
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.09
26360, 80207 NAMUR
42,5 26,5
8 10
ø 15,5
1/4”
1/4”
ø 21
Cable gland
C C
B D B D
A
0588925 only
A B C øD Model
M20 x 1,5 9 36 5 ... 8 22 0588819
M20 x 1,5 14 39 10 ... 14 24 0588851
1/2-14 NPT 15 58 7,5 ... 11,9 24 0588925
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes
systems only. Do not use these products where pressures and of all component parts used in pneumatic systems and to provide
temperatures can exceed those listed under »Technical features«. adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in
for non-industrial applications, life-support systems, or other ap- the system instructional manual if protection against
plications not within published specifications, consult NORGREN. a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with
fluid power systems can fail in various modes. these products.
N/en 5.4.386.10 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11