You are on page 1of 2

LPS SERIES-Solar Power

LPS12-285 (12V287.5AH)
Specification
Nominal Voltage 12V
Nominal Capacity(100HR) 287.5AH
Length 522±3mm (20.55 inches)
Width 268±3mm (10.55 inches)
Dimension
Container Height 220±3mm (8.66 inches)
Total Height (with Terminal) 226±3mm (8.90 inches)
Approx Weight Approx 74.0 Kg (163.2 Ibs)
Terminal T11
Container Material ABS
287.5 AH/2.88A (100hr ,1.80V/cell,25 0C/77 0F)
262.0 AH/13.1A (20hr ,1.80V/cell,25 0C/77 0F) Applications
Rated Capacity 250.0 AH/25.0A (10hr,1.80V/cell,25 0C/77 0F)
218.0 AH/43.6A (5hr,1.75V/cell,25 0C/77 0F) Green energy systems (solar, wind,
hydro, etc)
151.9 AH/151.9A (1hr,1.60V/cell,25 0C/77 0F) Solar power stations
Max. Discharge Current 2500A (5s) Telecommunications installations
Measurement stations
Internal Resistance Approx 2.5mΩ Pump systems
Discharge : -15~50 0C (5~122 0F) Signal station
Operating Temp.Range Charge : 0~40 0C (32~104 0F ) Survey and Mapping system
Emergency lighting
Storage : -15~40 0C (5~104 0F) Railway crossing
Nominal Operating Temp. Range 25±3 0C (77±5 0F ) Traffic lights
Street lightening
Initial Charging Current less than 75.0A.Voltage Lawn lamp
Cycle Use
14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C Street signs
SOS pillars
No limit on Initial Charging Current Voltage Alarm installations
Standby Use
13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C Weekend cottage camping
Caravans
40 o C (104 o F) 103%
Capacity affected by Boats or buoys
25 oC ( 77 o F) 100%
Temperature
0 oC ( 32 o F) 86% VdS
Leoch LPS series batteries may be stored for up to 6 months
Self Discharge at 25 0 C(77 0F) and then a freshening charge is required.
For higher temperatures the time interval will be shorter. 9 Germany
t est ed

Constant Current Discharge (Amperes) at 25 0C (77 0F )


F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 48h 100h
1.85V/cell 284.4 236.3 183.5 145.3 117.6 76.6 57.8 47.4 40.1 28.0 24.0 12.7 5.73 2.82
1.80V/cell 315.3 259.9 198.0 154.3 124.0 81.5 61.0 49.7 42.0 29.3 25.0 13.1 5.82 2.88
1.75V/cell 349.7 284.7 213.0 165.0 133.7 85.4 64.4 51.8 43.6 30.2 25.5 13.4 5.91 2.90
1.70V/cell 382.1 310.9 234.0 172.3 141.3 90.0 67.5 54.0 45.4 31.3 26.3 13.7 5.98 2.94
1.65V/cell 404.6 328.1 246.5 183.0 146.1 93.1 70.0 55.9 47.0 32.2 26.9 14.0 6.09 2.98
1.60V/cell 443.5 356.3 262.0 189.7 151.9 97.0 72.3 57.7 48.6 33.0 27.5 14.3 6.19 3.01

Constant Power Discharge (Watts/cell) at 25 0C (77 0F )


F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 48h 100h
1.85V/cell 533.5 447.7 351.6 280.8 228.7 149.6 113.2 93.0 78.9 55.5 47.6 25.3 11.5 5.64
1.80V/cell 583.5 485.2 373.6 294.6 239.2 158.0 118.8 97.0 82.4 58.1 49.6 26.1 11.6 5.74
1.75V/cell 639.4 526.5 398.6 313.3 256.7 164.9 125.0 101.0 85.3 59.6 50.7 26.6 11.8 5.78
1.70V/cell 688.9 570.7 435.5 326.1 270.3 173.4 130.7 105.1 88.6 61.8 52.2 27.1 11.9 5.85
1.65V/cell 726.7 600.1 456.9 344.7 278.6 178.9 135.3 108.5 91.5 63.4 53.3 27.7 12.1 5.93
1.60V/cell 780.4 642.1 480.2 353.7 287.0 184.9 138.9 111.4 94.3 64.9 54.4 28.3 12.3 5.97
Specifications subject to change without notice.

1
Dimensions

T11 Terminal
Unit: mm [inches]
φ20 [0.787]
M8 [0.315]

226±3

268±3
6 [0.236]

220±3
522±3

Discharge Characteristics Effect of Temperature on Long Term Float Life


2V 6V 12V
Battery Battery Battery Temperature:25 0C
(V) (V) (V)
16
12

Life expectancy(year)
Terminal Voltage(V)

2.16 6.50 13.0


10
2.00 6.00 12.0 8 Charging voltage
2.25V/cell
6
1.84 5.50 11.0
0.1C 0.0525C 0.02326C 0.0115C
0.25C 4
1.68 5.00 10.0
1.77C 1.04C 0.608C
1.52 4.50 9.00
1
1.36 4.00 8.00

2 4 6 8 15 20 40 60 100 200 400 600 1200 2000 3000 6000 (Min) 0


20 30 40 50 0
O
C
0.1 0.2 0.3 0.4 0.5 1 2 3 4 5 10 20 48 100 (Hours) 68 86 104 122 F

Discharge Time Battery temperature

Cycle Service Life Float Charging at


Self-Discharge Characteristics
Different Temperatures

100 100
Extracted Capcity in(%)

90
%Rated Capacity Available

80
70 75
60
50
40 50
40℃ 30℃ 20℃ 8℃
30 104℉ 86℉ 68℉ 46℉

20
25 Storage Time(months)
0 500 1000 1500 2000 2500 3000 3500

Number of Cycles 0 3 6 9 12 15 18 21 24 27

2.60
A Charge Mode
2.55
Charging in V per cell

2.50
Max.charge voltage With switch regulator (two-step controller) charge on curve max.charge voltage for
2.45 B A max.2 hrs/day then switch over to continous charge
Continous charge
2.40
Standard charge without switching
2.35
Standard charge B
Boost charge (Equalizing charge with external generator) charge on curve continous
2.30 C C charge for max. 5 hrs/month, then switch over to curve Standard charge
2.25
2.20
-20 -10 0 +10 +20 +30 +40 +50
Temperature(0C)

Sales Office
China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells
Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ,
Tel: +86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68636078 Tel: 949-588-5853 UK United Kingdom
Fax: +86-755-26067269 Tel: +852 35786666 Fax: +65 68636079 Fax: 949-588-5966 Tel: +44(0) 1452 729428 / 1452 729696
E-mail:export@leoch.com Fax: +852 21170016 Email sales.sg@Leoch.com E-mail: sales@leoch.us Fax: +44 (0)1452-690125
Http://www.leoch.com E-mail: sales.hk@leoch.com Http://www.leoch.com Http://www.leoch.us E-mail: Sales.Europe@leoch.com

Publication No.:LB-LPS-11-15
2

You might also like