DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
Address*
Mfg. Serial No.* Year Built* 2020 Edition & Addendum to API 650* 12TH EDITION ADD-2
Address
Tank Designation TK - 30 M3
5. Products Stored:
DESIGN AND TESTING Purchaser to Review Design Prior to Ordering Material? Yes X No
7. Max. Design. Temp. 60 ° C Design Metal Temp.* -196 ° C Design Liquid Level* 5.40 m
Design Pressure 0 kpa External Pressure 0.25 kpa Maximum Fill Rate Maximum Emptying Rate
Floatation Considerations? Yes No Flot. Suppl. Spec:* Applied Supplemental Load Spec.
8. Seismic Design? Yes X No Appendix E X Alternate Seismic Criteria Seismic Use Group I
MBE Site Class Vertical Seismic Design? Yes No Vertical Ground Motion Accelerator AV: 0.25
Basis of Lateral Acceleration (Select one): Mapped Seismic Parameters? Sds 1.12 Sd1 0.45 S0 0.41 ; X Site-Specific Procedures: MCE
Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring?* Yes No
9. Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gust)* 80 km/h
Top Wind Girder Style* B Dimensions* L50X50X5 mm Use Top Wind Girder as Walkway? Yes No X
10.Shell Design: 1-Ft Mthd?* Yes X No ; Variable-Des-Pt Mthd?* Yes No X Alternate ; Elastic Anal. Mthd?* Yes No Alternate
Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.
1. 1500x6000x6 mm 2. 1500x6000x6 mm 3. 1500x6000x6 mm 4. 1500x6000x6 mm 5.
6. 1500x2705x6 mm 7. 1500x2705x6 mm 8. 1500x2705x6 mm 9. 1500x2705x6 mm 10.
11. 12. 13. 14. 15.
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
11.Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs) Open Top?* Yes No X
Fixed Roof Type* STRUCTURALLY SUPPORTED CONICAL ROOF Roof Support Columns*: Pipe Or Structural Shape
Cone Slope* 3.57° Dome or Umbrella Radius* Weld Joints* But Weld
(Lap, Butt, Other)
Seal Weld Underside of: Lap Joints? Yes X No ; Seal Weld Underside of Wind Girder Joints? Yes No
12. Bottom: Thickness* 6 mm Style* Flat Bottom Slope* Weld Joint Type* Butt Weld
Provide Drip Ring? Yes No X Alternate Spec.
Annular Ring? Yes No X Annular Ring: Minimum Radial Width* Thickness*
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
16. Coatings:
Internal Coatings by: Per Spec.* PER SPEC
(Not Req'd., Others, Tank Mfg.)
External Coating by: Per Spec.* PER SPEC
(Not Req'd., Others, Tank Mfg.)
Under-Bottom Coating by: Per Spec.* PER SPEC
(Not Req'd., Others, Tank Mfg.)
20. Tank Measurement System: Required? Yes No Remote Capability Required? Yes No
21. Weight of Tank: Full of Water* 320,922.621 N Empty* 33,507 N Shipping* Brace/Lift Spec.*
23. Remarks:*
Top View
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series* C.A.
Flange Bolting ++
Structural Bolting ++
Anchor Bolts - ASTM A-193 Grado B8 ASTM A-194 Grado 8 8 UNC ++
Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)
Size, NPS, or Neck Sch or Flange Flange Class or Gasket Bearing Surf. Gasket Thick. Gasket Mat'l and Proj. to FF or CL or
Mark Service Dia. (in.) Wall Thick. Reinf. Plate Dimensions Orientate Type Thick. Dimen. and Finish and Dimen. Descript. from Datum Lines
Salida /
N1 6 40 400x6 mm 150° ASME B16.5 150 to be defined SS-304 200 RF
Caliente
N2 Rebose 6 40 400x6 mm 150° ASME B16.5 150 to be defined SS-304 200 RF
N10 Ingreso / Fria 6 40 400x6 mm 150° ASME B16.5 150 to be defined SS-304 200 RF
Nivel Bajo /
N11 0.75 340° to be defined SS-304 60
Fria
Sensor
N12 Temperatura 0.75 - - 350° - - to be defined SS-304 60
/ Fria
N13 Drenaje 2 80 - 105° - - to be defined SS-304 150 RF
Nivel Alto /
N14 0.75 - - 340° - - to be defined SS-304 60
Frio
Manhole
N15 20 6 mm 1055x6 mm 60° - - to be defined SS-304 200 RF
Cuerpo
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
24. Platform, Stairway, and Railing: Galvanizing Req'd?* Yes No X Stairway Style* Walk Surf. Type*
(Straight or Helical)
Architectural/Structural Specification*
29. Various Other Items: Welded Flush-Type: Shell Connection Cleanout Fitting Waive Application of Appendix P? Yes No
Miscellany #1 Miscellany #2
Miscellany #3 Miscellany #4
Miscellany #5 Miscellany #6
Mark Quantity Service or Description Size Orientation Height from Datum Material Remarks
Escalera de acceso
1 25º ASTM A-36
Externa
Jaula de seguridad 1 25º ASTM A-36
Baranda perimetral 1 25º ASTM A-36
Escalera de acceso
1 120º ASTM A-36
Interna
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
31. Seals
Electrically Isolate Mechanism from Shoes? Yes No Wax Scrapers Required? Yes No
Roof-Drain Check Valves Required? Yes No Roof-Drain Isolation Valves Required? Yes No
Roof-Drain Piping to External Nozzles: Mfg. Std. Armored Flexible Pipe Swivels in Rigid Pipe Other
Guide Pole for Gauging? Yes No Slots in Guide Pole? Yes No Datum Plates? Yes No Striking Plates? Yes No
Guide Pole Emissions-Limiting Devices: Sliding Cover Pole Wiper Pole Sleeve Float Float Wiper Pole Cap
Removable Leg Storage Racks? Yes No ; Leg Sleeves or Fixed Low Legs
Design Rainfall Intensity in./hr. (mm/hr) Based on a Minute Duration Associated with the Storm
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
Two-Position Legs? Yes No Cable-Supported Roof? Yes No Fixed-Roof Inspection Hatches Required? Yes No
Internal Roof Drain Required? Yes No Omit Distribution Pads Supporting Uniform Live Loads? Yes No
Corrosion Gauge Required? Yes No Fixed Ladder Required? Yes No ; Type of Roof Vent:*
Mfr. To Leak Test* % of Compartments in Assembly Yard in Erected Position Unknown; see separate contract terms
Roof Erector's Flotation Test: w/ Tank Hydro at Completion of Roof at a Later Date Not Required
Flotation Test Media: Water Product (see H.6.6.1) Water Quality: Potable Other See Supplemental Spec.
Flotation Test Items Provided by Purchaser (see H.6.7): None List Attached
Responsible Party for Inspecting Roof During Initial Fill: Purchaser Other
DATOS GENERALES
Nombre del Proyecto: Tanque de almacenamiento de 30m3 Cliente: Alicorp S.A.A.
Código de Información: HD-ABAD-2001-01 Descripción: TK - 30 M3
Notes:
1.- De acuerdo con la sección 7.3.6 Pruebas del cilindro a)., Iii). Llene a un nivel inferior al especificado en el ítem i). Nivel recomendado de prueba hidrostática Nivel de trabajo del tanque.
2.- 24 horas (el agua se vaciará en 14 días si no se requieren los aditivos adecuados). (Etapa máxima de tiempo 48 horas con la aprobación del Comprador).
3.- De acuerdo con la decisión del comprador.
4.- A ser definido por el Comprador considerando los recursos disponibles en planta.
5.- Instrumentación adjunta en el tanque de almacenamiento vertical.
Boquillas en el techo
Boquillas en el cilindro
Boquillas en el fondo