Professional Documents
Culture Documents
THTR
High End SolaSpot 1000
1000
CHAUVET R2 WASH
0 0
ETC Source-4 10°
L
ETC S4-19°LED Lustr
L
ETC S4-26° LED Lustr
L
60' 59' 58' 57' 56' 55' 54' 53' 52' 51' 50' 49' 48' 47' 46' 45' 44' 43' 42' 41' 40' 39' 38' 37' 36' 35' 34' 33' 32' 31' 30' 29' 28' 27' 26' 25' 24' 23' 22' 21' 20' 19' 18' 17' 16' 15' 14' 13' 12' 11' 10' 9' 8' 7' 6' 5' 4' 3' 2' 1' CL 1' 2' 3' 4' 5' 6' 7' 8' 9' 10' 11' 12' 13' 14' 15' 16' 17' 18' 19' 20' 21' 22' 23' 24' 25' 26' 27' 28' 29' 30' 31' 32' 33' 34' 35' 36' 37' 38' 39' 40' 41' 42' 43' 44' 45' 46' 47' 48' 49' 50' 51' 52' 53' 54' 55' 56' 57'
L
ETC S4 Fresnel Lustr
1 CL 1
Venue
LS # Trim Deck D' to PL Description
46 0'-0" 38'-9 1/2" CHIFFON DRAPERY
45 0'-0" 38'-1 1/2"
ETC ColorSource PAR-MR
411 412 413 414 415 416 417 NOTE: GROUND ROW 44 0'-0" 37'-5 1/2" #5 ELECTRIC
10 9 8 7 6 5 4 UNITS FOCUS US TOWARDS 43 0'-0" 36'-9 1/2"
CHIFFON CURTAIN
42 0'-0" 36'-1 1/2" CYCLORAMA ETC ColorSource PAR-WO•
41 0'-0" 35'-5 1/2" BLACK SCRIM
40 0'-0" 34'-9 1/2"
512 515
6 1 36 0'-0" 29'-5 1/2"
2 511 516
35
34
0'-0"
0'-0"
28'-9 1/2"
28'-1 1/2"
2
33 0'-0" 27'-5 1/2" #4 ELECTRIC
-
CHANNEL #
7 0'-0" 4'-9 1/2" #1 ELECTRIC
6 0'-0" 4'-1 1/2"
5 0'-0" 3'-5 1/2" HOUSE PROJ. SCREEN
PL PL
1 0'-0" 0'-9 1/2" FRONT VALANCE
701 702 703 704
N/A N/A 0" Plaster Line
60' 59' 58' 57' 56' 55' 54' 53' 52' 51' 50' 49' 48' 47' 46' 45' 44' 43' 42' 41' 40' 39' 38' 37' 36' 35' 34' 33' 32' 31' 30' 29' 28' 27' 26' 25' 24' 23' 22' 21' 20' 19' 18' 17' 16' 15' 14' 13' 12' 11' 10' 9' 8' 7' 6' 5' 4' 3' 2' 1' CL 1' 2' 3' 4' 5' 6' 7' 8' 9' 10' 11' 12' 13' 14' 15' 16' 17' 18' 19' 20' 21' 22' 23' 24' 25' 26' 27' 28' 29' 30' 31' 32' 33' 34' 35' 36' 37' 38' 39' 40' 41' 42' #
LS Trim
43'
Venue
44'
Deck D'
45' to PL
46' 47' 48' Description
49' 50' 51' 52' 53' 54' 55' 56' 57'
5 5
CL LD# 10574
mike@mikewoodld.com
Nashville, Tennessee, USA
http://www.mikewoodld.com
This drawing contains a visual concept and construction suggestions. The lighting designer and design
assistants/associates are not qualified to determine or guarantee the structural integrity or appropriateness
of any construction or rigging methods, and assume no liability or responsibility for the improper engineering,
construction, or use of any and all designs contained on this document and elsewhere throughout the
production. Always consult a licensed structural engineer before any rigging or construction takes place.
All applicable local and national fire and life safety codes must be follwed at all times.
REVISION HISTORY
NO. REVISION DATE BY
A01 SCENIC LAYOUT // DOC PREP 28 AUG 20 JS
>B01< LOAD IN 2 SEP 20 MW
6 6
CONCERT SERIES
PRODUCTION STAFF
LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD
ASST. LIGHTING DESIGNER . . . . . . . . .KATIE WOOD
DWG NUMBER
SCALE 1/4" = 1'
PG SIZE
UNLESS OTHERWISE NOTED
ARCH D 4 OF 4
LIGHT PLOT
A B C D E F G H I J DECK UNITS