You are on page 1of 115

NOTICE

Before using this Workshop Manual to assist you in performing


vehicle service and maintenance operations, it is recommended
that you carefully read and thoroughly understand the
information contained in Section 0A under the headings
"GENERAL REPAIR INSTRUCTIONS" and "HOW TO USE THIS
MANUAL".

All material contained in this Manual is based on the latest


product information available at the time of publication.
All rights are reserved to make changes at any time without
prior notice.

Applicable Model

N Series
NHR55 NPR55 NQR66
NHR69 NPR69 NQR70
NKR55 NPR65 NQR71
NKR69 NPR66 NPS66
NKR58 NPR70 NPS70
NKR66 NPR71 NPS71
NKR77

This manual is applicable to 1994 year model and later vehicles.


HOME
SERVICE INFORMATION 00-13
00-14 SERVICE INFORMATION
SERVICE INFORMATION 00-21

MAIN DATA AND SPECIFICATIONS


HEATER UNIT
Temperature control Reheat mix system
Capacity kW (kcal) 4.30 (3,700)
3
Air flow (m /hr) 280
HEATER CORE
Type Fin & tube type
EVAPORATOR ASSEMBLY
Capacity kW (kcal) 4.47 (3,850)
3
Air flow (m /hr) 420
EVAPORATOR CORE
Type AI-laminate louver fin type
EXPANSION VALVE
Type External pressure equalizer type
THERMOSTAT SWITCH
Type Electronic thermostat
°C (F) OFF: Below 3.5 ± 0.5 (38.3 ± 0.9)
ON: Above 5.0 ± 0.5 (41.0 ± 0.9)

CONDENSER
Type Parallel flow
Radiator performance kW (kcal) 11.0 (9,500) – NPR, NKR (except Taiwan)
7.9 (6,800) – NKR
5.1 (4,400) – NKR (for Taiwan)
RECEIVER/DRIVER
Internal volume cc (lmp. fl oz) 300 (8.5)
PRESSURE SWITCH
Type Dual pressure switch
2
kPa (kg⋅cm /PSI) • Low pressure control
ON: 206 ± 30 (2.1 ± 0.3 / 30 ± 4)
OFF: 176 ± 20 (1.8 ± 0.2 / 26 ± 3)
• High pressure control
ON: 2354 ± 196 (24.0 ± 2.0 / 341 ± 28)
OFF: 2942 ± 196 (30.0 ± 2.0 / 327 ± 28)
• Low pressure control (except Taiwan)
ON: 186 ± 30 (1.9 ± 0.3 / 27 ± 4)
OFF: 176 ± 20 (1.8 ± 0.2 / 26 ± 3)
• High pressure control (except Taiwan)
ON: 2354 ± 196 (24.0 ± 2.0 / 341 ± 28)
OFF: 2942 ± 196 (30.0 ± 2.0 / 327 ± 28)
• Low pressure control (for Taiwan)
ON: 221 ± 20 (2.25 ± 0.2 / 33 ± 3)
OFF: 196 ± 20 (2.0 ± 0.2 / 29 ± 3)
• High pressure control (for Taiwan)
ON: 2354 ± 196 (24.0 ± 2.0 / 341 ± 28)
OFF: 2942 ± 196 (30.0 ± 2.0 / 327 ± 28)
REFRIGERANT
Type/Specified amount g (Ibs) R-134a / 600 (1.32)
00-22 SERVICE INFORMATION

COMPRESSOR
Model DKS-15CH
DKS-15CH (except Taiwan)
DKS-13CH (for Taiwan)
Swash plate type
Number of cylinder 6
Bore mm (in) 36 (1.42)
Stroke mm (in) 24 (0.94)
Displacement cc (lmp fl oz) 147 (4.1)
Swash plate type (except Taiwan)
Number of cylinder 6
Bore mm (in) 36 (1.42)
Stroke mm (in) 24 (0.94)
Displacement cc (lmp fl oz) 147 (4.1)
Swash plate type (for Taiwan)
Number of cylinder 6
Bore mm (in) 36 (1.42)
Stroke mm (in) 21.4 (0.84)
Displacement cc (lmp fl oz) 131 (3.7)
Maximum speed (rpm) 7,000 (up to 8,400)
Direction of rotation Clockwise (Front-side view)
Lubrication system Pressure differential type
Lubricant cc (lmp fl oz) ZXL-100PG / 180 (5.0)
(ISUZU PART NO. 8-97101-338-0)

Refrigerant g (lbs) R-134a / 600 (1.32)


Shaft seal Lip type
Weight kg (lbs) 4.0 – 4.3 (8.8 – 9.5)
4.3 (9.5) (except Taiwan)
4.1 (9.0) (for Taiwan)

MAGNETIC CLUTCH
Type Electromagnetic single-plate dry clutch
Rated voltage 12 (24) Volts D.C.
Starting torque N⋅m (kg⋅m / lb⋅ft) 49 (5.0 / 36)

Direction of rotation Clockwise (Front-side view)


Weight kg (lbs) 2.0 (4.4)
HOME
HOME
AIR CONDITIONING 1B-7

Dual Pressure Switch Evaporator


The dual pressure switch is installed on the upper The evaporator cools and dehumidifies the air before
part the receiver/driver, to detect excessively high the air enters the vehicle. High-pressure liquid
pressure (high pressure switch) and prevent refrigerant flows through the expansion valve into the
compressor seizure due to the refrigerant leaking low-pressure area of the evaporator. The heat in the
(low pressure switch), switching the compressor air passing through the evaporator core is lost to the
“ON” or “OFF” as required. cooler surface of the core, thereby cooling the air.
The pressure switch connector is waterproof type. As heat is lost between the air and the evaporator
R-134a refrigerant pressure characteristics differ core surface, moisture in the vehicle condenses on
from those of R-12. Thus, the dual pressure switch the outside surface of the evaporator core and is
operation for R-134a systems has been changed drained off as water.
from R-12. When the evaporator malfunctions, the trouble will
• Low-pressure control
2
kpa (kg/cm /PSI) show up as inadequate supply of cool air. The
Compressor causes is typically a partially plugged core due to
ON: 206 ± 30 (2.1 ± 0.3 / 30 ± 4) dirt, or a malfunctioning blower motor.
OFF: 176 ± 20 (1.8 ± 0.2 / 26 ± 3) The evaporator core with a laminate louver fin is a
• Low-pressure control single-sided tank type where only one tank is
Compressor (except Taiwan) provided under the core.
ON: 186 ± 30 (1.9 ± 0.3 / 30 ± 4)
OFF: 176 ± 20 (1.8 ± 0.2 / 26 ± 3)
• Low-pressure control
Compressor (for Taiwan)
ON: 221 ± 20 (2.25 ± 0.2 / 33 ± 3)
OFF: 196 ± 20 (2.0 ± 0.2 / 29 ± 3)
• High-pressure control
ON: 2354 ± 196 (24.0 ± 2.0 / 341 ± 28)
OFF: 2942 ± 196 (30.0 ± 2.0/ 427 ± 28)
HOME
LGHAC-WE-9431

You are requested to order this manual using the


manual number that is shown above.

This manual is applicable for vehicles in all countries


except the USA and Canada.

All rights reserved. This manual may not be


reproduced in whole or in part, without the permission
in writing of ISUZU MOTORS LIMITED.

Issued by
ISUZU MOTORS LIMITED
INTERNATIONAL SERVICE DEPARTMENT

Tokyo, Japan

Second edition July, 2003 0307-02A-0


LGHAC-WE-9431 PRINTED IN JAPAN

You might also like