You are on page 1of 2

Value Basis Type 8202 pH/ORP meter (equipped with Type 8203 pH- and ORP-probe) – Analytical Sensors

Customer Needs Features Generic Benefits/Advantages Value Propositions


Target groups Type 8202 is used in applications like pH Adjustment (pH neutralisation) and Filtration (NF, RO), Water Quality Monitoring & Control
Basic need – “I want to use analog  Compact measurement device  Directly connectable to PLC via By providing the complete fluid control
(mA) signals and do not want an  Standard signal output analog signal (4…20 mA) loop – including sensors – customers
external transmitter.”  Raw signal transformed into standard  No need for an additional transmitter receive the best integrated solution.
signal – integrated transmitter
“I would like to monitor measurements “ELEMENT” variant with display: Easy and quick access to Enables quick reaction and adaption of
and calibrate the pH or ORP meter  Optional modular display with measurements, calibration and processes in-situ.
directly at the device.” quarter-turn cover “cloning”
 Parametrise-able and calibrate-able
“I need to assemble many pH or ORP (1- and 2-point) without external
meters with the same settings.” device using display (ELEMENT
variant)
 Clone settings from one meter to
another by mounting the display
Process diagnostics desired, e.g. “ELEMENT” variants with or without  A better understanding and overview Ensures high process reliability and
monitor pH or ORP measurement, display: about the in-situ process high reproducibility of the quality of
temperature and limits and warnings  Monitor pH/ORP and built-in  One device – purchase of a separate every production batch.
temperature (as analog signals) temperature sensor not necessary
 Upper/lower limit monitoring and
warnings (binary output)
 Lookup device status (functioning,
warning and error events)
 Set calibration interval – a timer to
remind on necessary probe
exchange
 LED as status indicator for calibration
operations and device status related
to alarms and warnings (with display)
“I think I need the minimum viable “Neutrino” variant: Directly connectable to PLC via analog Adequately fulfil the requirements for a
product” – no process diagnostics, no  Parametrise-able and calibrate-able signal (4…20 mA) basic pH/ORP measurement.
extra temperature signal, no display (1- and 2-point) without external
device
 Analog signal (4…20 mA)
Customer Needs Features Generic Benefits/Advantages Value Propositions
 Straight-forward handling For all variants:  Easy & fast commissioning & Time and cost savings due to
 Flexibility  Switchable functionality between pH maintenance  Minor training effort
 Low maintenance cost and ORP measurement device  Easy service and maintenance  Minor maintenance effort
 Easy commissionable with pH-/ORP-  Simple assembly and commissioning
probe Type 8203
 Installation and removal of the meter
without any additional tool
 Direct access to the pH/ORP probe
Highly aggressive fluid conditions Broad range of fitting materials Adaptation to applications with neutral Reducing process risk – using different
as well as aggressive fluids material for different fluids

Certain process port connections Broad range of fitting connections Fulfilling of common worldwide Flexibility in equipping diverse process
according to industrial standards ranging from 6 up to DN400 (Type standards sizes
needed S020)

More sales & marketing material:


 Launching Packages on Marketing Bridge: ELEMENT Transmitters Types 8202 and 8222
 Bürkert Website: 8202 (pH/ORP meter), 8203 (pH- and ORP-probes)

You might also like