You are on page 1of 7

H2O

ULTRASONIC
WATER METER
MID and CE approved, EN 14154, OIML
T30 / T50 / T70
IP 68 | DN 15 - DN 600
ULTRASONIC WATER METER

APPLICATION
The Helvatron water meter H2O designed for measure-
ment of cold and hot water consumption in households
and industrial applications for energy management
according to ISO 50001 and billing.

• Using latest ultrasonic technology


• High accuracy (EN 14154 / EN1434)
• AMR
• Suitable for energy management ISO 50001

APPROVALS
• MID and CE
• WRAS
• OIML R49 Compliant
• EN 14154

READ-OUT INTERFACE OPTIONS


• M-Bus (Wired or wireless)
• Modbus RTU RS485
• LoRa
• NB-IOT

FEATURES
• Temperature class T30, T50, T70, T90 • Nominal pressure PN16/25 bar
• Nominal flow 2.5 I 4.0 I 6.3 I 10 I 16 I 25 I 40 I 63 I 100 | • Internal data Iogger
160 | 250 | 400 | 630 | 1000 | 1600 | 2500 | 4000 m3/h • Battery lifetime > 16 years
• Dynamic range up to Q3 / Q1 = R 250 / R400 • Measure reverse flow (separate register)
• No straight sections required • Flow direction indication
• No measurement of air
• Ambient class B
• Protection class IP 68

2
HELVATRON H2O

OPTICAL INTERFACE LORA


lt is designed for data reading via M-bus protocol and • 868 Mhz
parameterization of the meter and for volume pulse
output in test mode.
ERRORCODES
WIRELESS M-BUS • Battery low alarm
• Air in pipe
The internal radio module provides data reading via
Wireless M-Bus telegram: S1, T1 and OMS mode. • Leak detection

WIRED M-BUS INTERFACE DATALOGGER- HISTORY VALUES


The integrated M-Bus communication interface allows
• Every hour, day and month values of the measured
data reading via M-Bus protocol.
parameters are stored in internal memory
• All data from archive can be read by means of the
remote reading.
DATA REGISTRATION
• ln addition data Iogger records of monthly pa-
• Total volume rameters can be seen on the display.
• Forward volume
• Reverse volume
DISPLAY
• Volume of pulse input 1 / Volume of pulse input 2
• The device is equipped
• Maximum and minimum flow rate value and date
with 8-digits LCD with
• Maximum temperature value and date (if used)
unique symbols to display parameters, measurement
• Minimum temperature value and date (if used) units and operation modes.
• Operating time without an error • The following information can be displayed:
• Error code - lntegral and instantaneous measured parameters,
• Time when the flow rate exceeded 1.2 Q4 - Archive data and set day data.
• Time when the flow rate was less than Q1 - Device configuration information

LCD INDICATIONS
Code Description

0 – no error, normal operation


1 – warning - less 6 month to ending battery life
Status of calculator 2 – battery low alarm (ending battery life)
8 – electronics failure (tamper attemt)

0 – no error, normal operation


1 – air messurement alarm (air less 10 min)
Status of flow sensor 2 – reverse flow alarm
4 – meter overload flow alarm (displeed q=1,2 Q4)

0 – no error, normal operation


1 – meter dry alarm (air more then 10 min)
Status of flow 2 – continoues zero flow alarm (more 24 h)
4 – leak / continous flow alarm (more 1 h)

0 – no error, normal operation


Status of temperature 1 – low temperature alarm (<3° C)
sensor (if used) 2 – meter overload temperature alarm (>90° C)
4 – failure of temperature sensor (or disconnected)

3
ULTRASONIC WATER METER

POWER SUPPLY
One of the following options depending on water meter configuration:
• Standard: Battery 3,6 V 2.4 Ah (Li-SOCI2) battery, operation time approx. 16 years
• Option: 12..42 V DC external power supply

TECHNICAL DATA

Q3 [m3/hl] 2.5 / 4.0 / 6.3 / 10 / 16 / 25 / 40 / 63 / 100


Flow rate Q31.6: 250
sensor R Q3 /Q1 [m /hl]
3
Q3 2.5: 250 / 400
Q3 4.0, 6.3,10,16, 25,40, 63,100: 250 / 400
LCD Display 8-digit
Measuring accuracy Class 2 (OIML R49)
Protection dass [IP] IP68
Ambient class Class B / EN 14 154 / EN1434
Mechanical class 2 (MID)
Electromechanical class 1 (MID)
Ambient temperature +5°C... +65°C

Default 0.1°C to + 50°C


Medium Temperature
Technical data On request: 1°C to + 70°C / 90°C

Installation place indoor, outdoor in a pit or inst. box


all installation positions
Installation position
vertical, horizontal. rising pipe, down pipe
Nominal pressure [bar] PN16 / 25 bar
Pressure loss 0.63 / (0.25) bar
Battery lifetime 10-16 years
UV protection Stabilized
Wetted surfaces Lead free brass CW724R

4
HELVATRON H2O

DN (mm) 15 20 25 40 50 65 80 100
L (mm) 110 130 260 300 200 200 225 250
H (mm) 81 85 129/130 144/152 172 180/183 197/200 222/235

G or G3/4 G1 or G1 1/4 G2
DN50 DN65 DN80 DN100
Flange DN DN15 DN20 DN25 DN40

DN (mm) 125 150 200 250 300 350 400 500 600
Q3 m3/h 160 250 400 630 1000 1000 1600 2500 4000
L (mm) 250 300 350 450 500 500 600 600 600
Flange DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600

Th- Joining to the pipeline Overall ΔP


Q3, m3/h RQ3 / Q1 Q4, m3/h Q1, m3/h Q2, m3/h reshold (Thread- G, flange-DN) length L. (bar x 100)
mm
2,5 R250 3,125 0,01 0,016 0,005 G3/4" 110 ΔP63
4 R250 5 0,016 0,026 0,008 G1" 130 ΔP 63
6,3 R250 7,875 0,0252 0,04 0,012 DN25, DN32 260 ΔP 25
10 R250 12,5 0,04 0,064 0,02 DN32 260 ΔP 63
16 R250 20 0,064 0.1 0,03 G2"or DN40 300 ΔP 63
25 R400 31.25 0,1 0.16 0,05 DN50 270 ΔP 63
DN65 300,350 ΔP 63
40 R400 50 0.16 0.26 0,08
DN80 300,350 ΔP 25
DN80 300,350 ΔP 63
63 R400 78,75 0,252 0.4 0.12
DN100 350.360 ΔP 25
100 R400 125 0.4 0.64 0,2 DN100 350.360 ΔP 63

5
ULTRASONIC WATER METER

T50
Type DN Joining Q3, m3/h Length
[mm] RQ3 / Q1 Interface Part no.

Helvatron H2O M-Bus DN 15 G 3/4 B 2.5m3/h 110 R250 M-Bus WAAE.20C.ABM

Helvatron H2O M-Bus DN 20 G1B 4.0m3/h 130 R250 M-Bus WABG.20C.ABM

Helvatron H2O M-Bus DN 25 G 1 1/4 B 6.3m3/h 260 R250 M-Bus WACI.20C.ABM

Helvatron H2O M-Bus DN 32 G 1 1/2 B 10m3/h 260 R250 M-Bus WADJ.20C.ABM

Helvatron H2O M-Bus DN 40 G2B 16m3/h 300 R250 M-Bus WAEL.20C.ABM

Helvatron H2O M-Bus DN 50FL Flanged 25m3/h 200 R400 M-Bus WAFFM.20C.ABM

Helvatron H2O M-Bus DN 65FL Flanged 40m3/h 200 R400 M-Bus WAGFN.20C.ABM

Helvatron H2O M-Bus DN 80FL Flanged 63m /h


3
225 R400 M-Bus WAHFO.20C.ABM

Helvatron H2O M-Bus DN 100FL Flanged 100m3/h 250 R400 M-Bus WAIFP.20C.ABM

Helvatron H2O M-Bus DN 125FL Flanged 160m3/h 250 R400 M-Bus WAJFQ.20C.ABM

Helvatron H2O M-Bus DN 150FL Flanged 250m3/h 250 R400 M-Bus WAKFS.20C.ABM

Helvatron H2O M-Bus DN 200FL Flanged 400m3/h 350 R400 M-Bus WALFU.20C.ABM

Helvatron H2O M-Bus DN 250FL Flanged 560m /h


3
450 R400 M-Bus WAMFV.20C.ABM

Helvatron H2O M-Bus DN 300FL Flanged 1000m3 450 R400 M-Bus WAMFV.20C.ABM

Helvatron H2O M-Bus DN 400FL Flanged 1600m3 600 R400 M-Bus WAPF0.20C.ABM

Helvatron H2O M-Bus DN 500FL Flanged 2500m3 600 R400 M-Bus WARF0.20C.ABM

RS 485 Modbus
Helvatron H2O RS485 DN 15 G 3/4 B 2.5m3/h 110 R250 RS485 WAAE.20C.ABMO

Helvatron H2O RS485 DN 20 G1B 4.0m3/h 130 R250 RS485 WABG.20C.ABMO

Helvatron H2O RS485 DN 25 G 1 1/4 B 6.3m3/h 260 R250 RS485 WACI.20C.ABMO

Helvatron H2O RS485 DN 32 G 1 1/2 B 10m /h


3
260 R250 RS485 WADJ.20C.ABMO

Helvatron H2O RS485 DN 40 G2B 16m3/h 300 R250 RS485 WAEL.20C.ABMO

Helvatron H2O RS485 DN 50FL Flanged 25m /h


3
200 R400 RS485 WAFFM.20C.ABMO

Helvatron H2O RS485 DN 65FL Flanged 40m3/h 200 R400 RS485 WAGFN.20C.ABMO

Helvatron H2O RS485 DN 80FL Flanged 63m3/h 225 R400 RS485 WAHFO.20C.ABMO

Helvatron H2O RS485 DN 100FL Flanged 100m3/h 250 R400 RS485 WAIFP.20C.ABMO

Helvatron H2O RS485 DN 150FL Flanged 250m3/h 250 R400 RS485 WAKFS.20C.ABMO

LoRa
Helvatron H2O LoRa DN 15 G 3/4 B 2.5m3/h 110 R250 LoRa WAAE.20C.ABL

Helvatron H2O LoRa DN 20 G1B 4.0m3/h 130 R250 LoRa WABG.20C.ABL

Helvatron H2O LoRa DN 25 G 1 1/4 B 6.3m3/h 260 R250 LoRa WACI.20C.ABL

Helvatron H2O LoRa DN 32 G 1 1/2 B 10m3/h 260 R250 LoRa WADJ.20C.ABL

Helvatron H2O LoRa DN 40 G2B 16m3/h 300 R250 LoRa WAEL.20C.ABL

Helvatron H2O LoRa DN 50FL Flanged 25m3/h 200 R400 LoRa WAFFM.20C.ABL

Helvatron H2O LoRa DN 65FL Flanged 40m3/h 200 R400 LoRa WAGFN.20C.ABL

Helvatron H2O LoRa DN 80FL Flanged 63m3/h 225 R400 LoRa WAHFO.20C.ABL

Helvatron H2O LoRa DN 100FL Flanged 100m3/h 250 R400 LoRa WAIFP.20C.ABL

6
HELVATRON H2O

T70 OR T90 ON REQUEST


Type DN Joining Q3, m3/h Length
[mm] RQ3 / Q1 Interface Part no.

Helvatron H2O M-Bus DN 15 G 3/4 B 2.5m3/h 110 R250 M-Bus WAAE.20H.ABM


Helvatron H2O M-Bus DN 20 G1B 4.0m3/h 130 R250 M-Bus WABG.20H.ABM
Helvatron H2O M-Bus DN 25 G 1 1/4 B 6.3m3/h 260 R250 M-Bus WACI.20H.ABM
Helvatron H2O M-Bus DN 32 G 1 1/2 B 10m3/h 260 R250 M-Bus WADJ.20H.ABM
Helvatron H2O M-Bus DN 40 G2B 16m3/h 300 R250 M-Bus WAEL.20H.ABM
Helvatron H2O M-Bus DN 50FL Flanged 25m3/h 200 R400 M-Bus WAFFM.20H.ABM
Helvatron H2O M-Bus DN 65FL Flanged 40m3/h 200 R400 M-Bus WAGFN.20H.ABM
Helvatron H2O M-Bus DN 80FL Flanged 63m3/h 225 R400 M-Bus WAHFO.20H.ABM
Helvatron H2O M-Bus DN 100FL Flanged 100m3/h 250 R400 M-Bus WAIFP.20H.ABM
Helvatron H2O M-Bus DN 150FL Flanged 250m /h
3
250 R400 M-Bus WAKFS.20H.ABM
RS 485 Modbus
Helvatron H2O RS485 DN 15 G 3/4 B 2.5m3/h 110 R250 RS485 WAAE.20H.ABMO
Helvatron H2O RS485 DN 20 G1B 4.0m3/h 130 R250 RS485 WABG.20H.ABMO
Helvatron H2O RS485 DN 25 G 1 1/4 B 6.3m3/h 260 R250 RS485 WACI.20H.ABMO
Helvatron H2O RS485 DN 32 G 1 1/2 B 10m /h
3
260 R250 RS485 WADJ.20H.ABMO
Helvatron H2O RS485 DN 40 G2B 16m3/h 300 R250 RS485 WAEL.20H.ABMO
Helvatron H2O RS485 DN 50FL Flanged 25m3/h 200 R400 RS485 WAFFM.20H.ABMO
Helvatron H2O RS485 DN 65FL Flanged 40m3/h 200 R400 RS485 WAGFN.20H.ABMO
Helvatron H2O RS485 DN 80FL Flanged 63m3/h 225 R400 RS485 WAHFO.20H.ABMO
Helvatron H2O RS485 DN 100FL Flanged 100m3/h 250 R400 RS485 WAIFP.20H.ABMO
Helvatron H2O RS485 DN 150FL Flanged 250m3/h 250 R400 RS485 WAKFS.20H.ABMO
LoRa
Helvatron H2O LoRa DN 15 G 3/4 B 2.5m3/h 110 R250 LoRa WAAE.20H.ABL
Helvatron H2O LoRa DN 20 G1B 4.0m /h
3
130 R250 LoRa WABG.20H.ABL
Helvatron H2O LoRa DN 25 G 1 1/4 B 6.3m3/h 260 R250 LoRa WACI.20H.ABL
Helvatron H2O LoRa DN 32 G 1 1/2 B 10m3/h 260 R250 LoRa WADJ.20H.ABL
Helvatron H2O LoRa DN 40 G2B 16m3/h 300 R250 LoRa WAEL.20H.ABL
Helvatron H2O LoRa DN 50FL Flanged 25m3/h 200 R400 LoRa WAFFM.20H.ABL
Helvatron H2O LoRa DN 65FL Flanged 40m3/h 200 R400 LoRa WAGFN.20H.ABL
Helvatron H2O LoRa DN 80FL Flanged 63m3/h 225 R400 LoRa WAHFO.20H.ABL
Helvatron H2O LoRa DN 100FL Flanged 100m3/h 250 R400 LoRa WAIFP.20H.ABL