You are on page 1of 33

iPASOLINK 400 Clock Module

Clock Module
CLK2M-C

Option module for Clock Sync and mounted on MC-A4 Main Board.

Required for all stations for Network Sync


1. SNCP E1 Ring Configuration
2. Channelized STM-1 (Not required for STM-1 SPI Mode operation)
3. Sync Ether
4. External CLK In/Out
5 IEEE 1588v2(slave)
5.

*1 Not required for HOP Topology, TREE Topology, for the case Network Sync is not in use in Back-Back
Connection.
*2 SNCP E1 Ring Topology, Channelized STM-1,Sync E and IEEE1588v2 Software key is separately required.

iPASOLINK Introduction 49
iPASOLINK 200 / 400/1000 Modem

Power ON/OFF
Ground Switch

iPASOLINK-200
iPASOLINK-400/1000
iPASOLINK 400/1000

Alarm ( Red )

Power ON (Green)

TX STATUS (Green)

RX STATUS (Green)

IF IN / OUT
TX frequency: 350 MHz
RX frequency 140 MHz
Reff F
R Frequency: 5 MHz
MH (XPIC)
DC Power : -48V
XIF IN/ OUT
Connector: TNC (Female)
Frequency: 140 MHz
Control 10 MHz
REF FREQ: 5 MHz
Impedance: 50 Ohms
Connector: IEC 169-29(1.0/2.3)
169-29(1 0/2 3)
Impedance: 75 Ohms
FOR XPIC BETWEEN MASTER
AND SUB MASTER

iPASOLINK Introduction 50
iPASOLINK 200 / 400/1000 IDU E1 Interfaces

Option Card

Main Board

2M IN /OUT
Input / Output 16 x E1
signal
Bit Rate 2.048Mpps +/_ 50ppm
Interface HDB3 (ITU-T G.703)
IImpedance
d 75 Ohms,
Oh Unbalance
U b l
(S/W 120 Ohms Balance
Selectable)
Connector MDR-68 pins

Option Card

Main Board

Alarm (Red)
Alarm Status

iPASOLINK Introduction 51
iPASOLINK 200 / 400/1000 IDU – STM-1 Card

iPASOLINK 200 iPASOLINK 400/100

iPASOLINK 200 / 400/1000 iPASOLINK 200 / 400/1000

STM-1 INTFC (ELECTRICAL) -SPECIFICATIONS STM-1 INTFC (OPTICAL) -SPECIFICATIONS


TYPE ITU-T G.703 TYPE ITU-T G957
BITRATE 155.520 Mbps BITRATE 155.520 Mbps
LEVEL 1 Vp_p L-1.1: 0 TO -8 (TX) / -10 TO -34 dBm (RX)
LEVEL
CODE CMI S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
CODE NRZ
CONNECTOR IEC 169-29 (1.0/2.3)
WAVELENGTH 1310 NM
IMPEDANCE 75 Ohms (Unbalanced)
CONNECTOR LC

Transport modes of STM-1.


Through (SPI) Mode
iPASOLINK 400/1000 iPASOLINK 400/1000
Port1
STM1 STM1 iPASO 400 Automatic Protection Switching SFP combination
No Port 1 Port 2
APS Grp-1 APS Grp1 APS Grp2
1 S-1.1 -
Same slot Different slot
2 L-1.1 -
Channelized Mode Port 1 Port2 Slot1 Slot2 Slot1 Slot2
3 ELE -
Port1 port1 port2 port2
Port1 4 S-1.1 S-1.1
STM1 -
--- 63 E1
5 L-1.1 L-1.1

6 ELE ELE

iPASOLINK Introduction 52
2 x STM-1 universal card (STM1-A)

Transport modes of STM-1.

Online Status (Green) Online Status (Green) Alarm ( Red )


Through
g (SPI)
( ) Mode Transparent mode of STM
STM-11. No processing in IDU.
IDU
Port1 -2 STM-1 can be handled by single module Online LED indicates the ONLINE
STM1 STM1
STM-1 in APS operation
STM1 STM1
Port2

Through (SPI) Mode with APS SPI mode with line redundancy (APS).
(APS)
The following Software Key is required
Port1 -STM-1 APS Protection Key
STM1 STM1
STM1
Port2
Terminatingg MST / RST of STM-1 and drop
p insert in VC-12 (
(E1)level
)
Port1should be source port
Channelized Mode CLK2M-C module is required
Port1 The following Software Key is required
STM1
- STM-1 MUX/DEMUX Key
-
--- 63 E1
Port2

Channelized Mode with APS Channelized-STM-1 mode with line redundancy (APS)
CLK2M-C module is required
Port1
STM1 The following Software Key is required
- -STM-1 MUX/DEMUX Key
STM1
Port2
--- 63 E1
-STM-1 APS Protection Key

iPASOLINK Introduction 53
Channelized STM-1 Numbering
STM‐1
STM 1  STM‐1
STM 1  STM‐1
STM 1 
TUG‐3#  TUG‐2#  TU‐12#  TUG‐3#  TUG‐2#  TU‐12#  TUG‐3#  TUG‐2#  TU‐12# 
channelized  channelized  channelized 
Port No.  #K  #L  #M  Port No.  #K  #L  #M  Port No.  #K  #L  #M 
1 1 1 1 29 2 3 2 57 3 5 3
2 2 1 1 30 3 3 2 58 1 6 3
3 3 1 1 31 1 4 2 59 2 6 3
4 1 2 1 32 2 4 2 60 3 6 3
5 2 2 1 33 3 4 2 61 1 7 3
6 3 2 1 34 1 5 2 62 2 7 3
7 1 3 1 35 2 5 2 63 3 7 3
8 2 3 1 36 3 5 2
9 3 3 1 37 1 6 2
10 1 4 1 38 2 6 2
11 2 4 1 39 3 6 2
12 3 4 1 40 1 7 2
13
3 1 5 1 41 2 7 2
14 2 5 1 42 3 7 2
15 3 5 1 43 1 1 3
16 1 6 1 44 2 1 3
17 2 6 1 45 3 1 3
18 3 6 1 46 1 2 3
19 1 7 1 47 2 2 3
20 2 7 1 48 3 2 3
21 3 7 1 49 1 3 3
22 1 1 2 50 2 3 3
23 2 1 2 51 3 3 3
24 3 1 2 52 1 4 3
25 1 2 2 53 2 4 3
26 2 2 2 54 3 4 3
27 3 2 2 55 1 5 3
28 1 3 2 56 2 5 3

iPASOLINK Introduction 54
iPASOLINK 200 Ethernet Interfaces
FE LAN INTFC ( 1 ,2,)
2) Gigabit Ether Interface (Electrical) Port 1,2,3,4
1234
Input / Output signal 10/100 Base-T(X) Input / Output signal 10/100Base-T(X)/ 1000 BASE-T
Auto or Fixed Speed & Duplex 10/100 Base-T(X) / 1000 Base-T
Flow Control Full duplex or half duplex Auto Sensing or Fixed
Target frame IEEE802.3 64 to 1526 bytes
Flow Control ON or OFF (Selectable)
Jumbo frame Up to 2000 bytes
Link Loss Forwarding Disable/Enable (Selectable)
Forwarding Mode Store and Forwarding
Connector 2 X RJ 45 Connector 4 x RJ-45
Link Loss Forwarding Disabled / Enabled selectable Transmission Rate 460 Mbps

Gigabit Ether Interface (Optical) 5, 6


Input / Output signal 1000 BASE-SX / 1000 BASE - LX
Speed & Duplex 1000 Mbits Full Duplex Auto Negotiation fixed
Flow Control ON or OFF (Selectable)
Link Loss Forwarding Disable/Enable (Selectable)
Connector SFP Optical Interface (LC)
Transmission Rate p
460 Mbps

iPASOLINK Introduction 55
iPASOLINK 400/1000 Main Board
2M IN /OUT
Input / Output signal 16 x E1
Bit Rate 2.048Mpps +/_ 50ppm
Interface HDB3 (ITU-T G.703)
Impedance 75 Ohms,
Ohms Unbalance
(S/W Selectable) 120 Ohms Balance
Connector MDR-68 pins

400

1000

LAN Interface (Electrical) Port 1,2 Gigabit Ether Interface (Optical) 3,4
Input / Output signal 10/100Base-T(X) or 10/100/1000 BASE-T Input / Output signal 1000 BASE-SX / 1000 BASE - LX
Speed & Duplex 10/100 Base-T(X) / 1000 Base-T Auto Speed & Duplex 1000 Mbits Full Duplex Auto
Sensing or Fixed Negotiation fixed
Flow Control ON or OFF (Selectable) Flow Control ON or OFF (Selectable)
Link Loss Forwarding Disable/Enable (Selectable) Link Loss Forwarding Disable/Enable (Selectable)
Connector RJ-45 Connector SFP Optical Interface (LC)
Transmission Rate 460 Mbps Transmission Rate 460 Mbps
Port 1 can be selected as user port1 or Management port NE SFP opticalS-1.1/L1.1
Electrical (RJ-45)*
Software key Required to activate ports 3, 4

iPASOLINK Introduction 56
iPASOLINK 400/1000 GbE Universal Slot Interface
Port2 (Green) Port4(Green)
LAN Link Status LAN Link Status
Blink when data TX Blink when data TX

Por1 (Green)
LAN Interface (Electrical) Port 1,2 LAN Link Status
Input / Output signal 10/100Base-T(X)/ 1000 BASE-T Blink when data TX
Alarm (Red)
Speed & Duplex 10/100 Base-T(X) / 1000 Base-T Alarm Status
Port 3(Green)
Auto Sensing or Fixed
LAN Link Status
Flow Control ON or OFF (Selectable) Blink when data TX

Link Loss Forwarding Disable/Enable (Selectable)


Connector RJ-45
Transmission Rate 460 Mbps

Ethernet Features
VLAN Port Based VLAN/ Tag Based VLAN / Q –in Q
Gigabit Ether Interface (Optical) 3,4
QoS 802.1p CoS / ToS/Diffserv/MPLS EXP
Input / Output signal 1000 BASE-SX / 1000 BASE -
QoS Control 4SP, 1xSP+3xDWRR, 4xDWRR, 1xSP+7DWRR,
LX
2xSP+6DWRR
Speed & Duplex 1000 Mbits Full Duplex Auto
Bandwidth Port and class shaper, policing per VLAN or port Negotiation fixed
Management
Flow Control ON or OFF (Selectable)
Jumbo frame Up to 2000 bytes
Link Loss Forwarding Disable/Enable (Selectable)
Protection RSTP (802.1w, ERP (ITU-T G.8032)* LACP
(802.3ad)* Connector SFP Optical Interface (LC)
Note *-late
late release Transmission Rate 460 Mbps

iPASOLINK Introduction 57
iPASOLINK 200 Power supply

SELV (DC IN) 4 Pin


1 -48 V (-40.5 to -57)
2 -48 V (-40.5 to -57)
3 Ground
SW
4 Ground
AMP 1-178288-4 or DK-3100S-04R
Contacts: AMP:1-175218-2
Connector

SW

iPASOLINK Introduction 58
iPASOLINK 400 Power Supply

Cylindrical Fuse
ES1-12500 (250 V / 12.5 AH

SELV (DC IN) 4 Pin


1 -48 V (-40.5 to -57)
2 -48 V (-40.5 to -57)
3 Ground
4 Ground
AMP 1-178288-4 or DK-3100S-04R
Contacts: AMP:1
AMP:1-175218-2
175218 2
Connector

iPASOLINK Introduction 59
iPASOLINK 1000 Power Supply

Cylindrical Fuse
ES1-12500 (250 V / 12.5 AH

SELV (DC IN) 4 Pin


1 -48 V (-40.5 to -57)
2 -48 V (-40.5 to -57)
3 -48
48 V (-40.5
( 40 5 to -57)
57)
4 -48 V (-40.5 to -57)
5 -48 V (-40.5 to -57)
6 Ground
7 Ground
8 Ground
9 Ground
10 Ground
AMP 2048J7AB10FCT or
DK-3100S-10R
C t t AMP
Contacts: AMP:1-175218-2
1 175218 2
Connector

iPASOLINK Introduction 60
AUX Card – AUX-A
Optional auxiliary Module support ALM / EOW / NE2

The following Interface is available


・HK ALM IN/OUT
・additional
dditi l four
f parallel
ll l alarm
l outputs
t t
・EOW B-B connection 2 Port
・NE2 : DCN RS-485 (Async.) Back – to-back connection

Summary of the auxiliary interface ports.


iPASO400 iPaso1000 iPASO1000 iPASO 400/1000
MC-A4 MC-M
Interface TERM-M AUX-A (Option) Note
(main card) (main card)
IN - - - 6 (ALM I/P),4 (CLS in)
HK ALM
OUT 2 (ALM) 2 (ALM) - 4 (HK CTRL),4CLSW(out)
Jack 1 1 - -
BZ 1 1 - -
OW
Call SW 1 1 - -
EXT IN/OUT - - - 2 For Back-to-Back connection
V.11 2 1 1 - Sync / Async
DSC
RS-232C 2 1 1 - Async
LCT 1 1 - - 10/100BASE-T(X)
NMS 1 - 1 - 10/100BASE-T(X)
DCN
NE 1 - 1 - 10/100BASE-T(X)
NE2 - - - 1 9.6kbps Async (RS-485)DCN port
USB MEM slot 1 1 - - For F/W download, etc.
2MHz / b
2MH bps *Optional
*O ti l clock
l k
EXT CLK IN / OUT (1)* 1 - -
(CLK2M-C) module is required.

iPASOLINK Introduction 61
TERM-M Card

Alarm

1 NMS TXD(+) 1 NMS TXD(+)


SC D-Sub 15 Pins, Female)
2 NMS TXD (-) 2 NMS TXD (-)
1 V.11-3 IDT (+) 6 V.11-3 ICK (+) 11 V.11-3 IFP (+)
3 NMS RXD (+) 3 NMS RXD (+)
2 V.11-3 IDT (-) 7 V.11-3 ICK (-) 12 V.11-3 IFP (-)
4 Not Connected 4 Not Connected
3 V.11-3 ODT (+) 8 V.11-3 OCK (+) 13 V.11-3 OFP (+)
5 Not Connected 5 Not Connected
4 V.11-3 ODT (-) 9 V.11-3 OCK (-) 14 V.11-3 OFP (-)
6 NMS RXD (-) 6 NMS RXD (-)
5 RS-232C-3
RS 232C 3 IN 10 GND 15 RS-232-C-3
RS 232 C 3 OUT
7 Not Connected 7 Not Connected
8 Not Connected 8 Not Connected
NMS (RJ-45) NE1 (RJ-45)
iPASOLINK 200 / 400 - AUX Card ( AUX-S / AUX-A)

ALM / EOW (High Density D-Sub 44 Pins, Female) AUX (High Density D-Sub 44 Pins, Female)
1 EOW 1 IN(+) 16 EOW 1 IN (-) (GND) 31 CALL1 OUT 1 EOW 1 IN(+) 16 EOW 1 IN (-) (GND) 31 CALL1 OUT
2 EOW 1 OUT(+) 17 EOW 1 OUT (-) (GND) 32 BZ2 IN 2 EOW 1 OUT(+) 17 EOW 1 OUT (-) (GND) 32 BZ2 IN
3 EOW 2 In (+) 18 EOW 2 IN(-) (GND) 33 CALL2 OUT 3 EOW 2 In (+) 18 EOW 2 IN(-) (GND) 33 CALL2 OUT
4 EOW 2 Out (+) 19 EOW 2 Out (-) (GND) 34 GND 4 EOW 2 Out (+) 19 EOW 2 Out (-) (GND) 34 GND
5 GND 20 ALM6/HK1/C1 OUT (COM) 35 ALM6/HK1/C1 OUT (NC) 5 GND 20 ALM6/HK1/C1 OUT (COM) 35 ALM6/HK1/C1 OUT (NC)
6 ALM6/HK1/C1 OUT (NO) 21 ALM5/HK2/C2 OUT (COM) 36 ALM5/HK2/C2 OUT (NC) 6 ALM6/HK1/C1 OUT (NO) 21 ALM5/HK2/C2 OUT (COM) 36 ALM5/HK2/C2 OUT (NC)
7 ALM5/HK2/C2 OUT (NO) 22 ALM4/HK3/C3 OUT (COM) 37 ALM4/HK3/C3 OUT (NC) 7 ALM5/HK2/C2 OUT (NO) 22 ALM4/HK3/C3 OUT (COM) 37 ALM4/HK3/C3 OUT (NC)
8 ALM4/HK3/C3 OUT (NO) 23 ALM3/HK4/C4 OUT(COM) 38 ALM3/HK4/C4 OUT(NC) 8 ALM4/HK3/C3 OUT (NO) 23 ALM3/HK4/C4 OUT(COM) 38 ALM3/HK4/C4 OUT(NC)
9 ALM3/HK4/C4 OUT(NO) 24 NE2_RXD_TERM 39 NE2_RXD (+) 9 ALM3/HK4/C4 OUT(NO) 24
10 NE2_TXD(+) 25 40 NE2_RXD(-) 10 25
11 NE2_TXD(-) 26 HK4/CLSTR3 IN (-) (GND) 41 HK6/CLSTR1 IN (-) (GND) 11 26 HK4/CLSTR3 IN (-) (GND) 41 HK6/CLSTR1 IN (-) (GND)
12 HK2 INPUT(-) (GND) 27 HK4/CLSTR3 IN (+) 42 HK6/CLSTR1 IN (+) 12 HK2 INPUT(-) (GND) 27 HK4/CLSTR3 IN (+) 42 HK6/CLSTR1 IN (+)
13 HK2 INPUT(+) 28 HK3/CLSTR4 IN (-) (GND) 43 HK5/CLSTR2 IN (-) (GND) 13 HK2 INPUT(+) 28 HK3/CLSTR4 IN (-) (GND) 43 HK5/CLSTR2 IN (-) (GND)
14 HK1 INPUT(-) (GND) 29 HK3/CLSTR4 IN (+) 44 HK5/CLSTR2 IN (+) 14 HK1 INPUT(-) (GND) 29 HK3/CLSTR4 IN (+) 44 HK5/CLSTR2 IN (+)
15 HK1 INPUT(+) 30 BZ 1 IN 15 HK1 INPUT(+) 30 BZ 1 IN

iPASOLINK Introduction 63
iPasolink FAN Module

1000

200

400

In case the FAN alarm occurs, replace the


FAN unit immediately.
The FAN unit can be replaced
p under ppower-
on condition (hot-swappable).

iPASOLINK Introduction 64
PERFORMANCE – iPASOLINK 200 IDU
ITEM IDU
Channel Spacing 7 MHZ 14 MHz (13.75 MHz ) 28 MHz (27.5 MHz) 56 MHz (55 MHz)
QPSK 14 28 57 114
Transmission 16 QAM 28 56 114 229
Capacity
32 QAM 35 71 143 287
andd
Channel spacing 64 QAM 45 85 172 345
128 QAM 49 99 200 402
256 QAM - 114 229 460
[[Band width within p
parenthesis is Channel Spacing
p g at 18 Ghz band ] [capacity
[ p y is physical
p y layer
y maximum throughput
g p at 64 bytes
y p
packet size]]
E1 16xE1 (G703) MDR 68 connector in main board (32 E1 with additional 16 E1 optional card)
2 x 10/100 Base-T(X) RJ-45 connector (up to 4 x 10/100/1000 Base –T available with software upgrade)
Main Signal Interface LAN
2 x 1000 SX or LX with SFP modules (connector type LC)
STM-1 1 x STM-1 (S 1.1 or L 1.1 ) option card with software selectable channelized STM-1 (connector type – LC)
Connector Type : TNC female
Inter facility Link (IDU-ODU)
Cable length : Nominal 300m maximum with 8D-FB-E or equivalent performance cable
FUNCTION OUTLINE
Native IP and Native TDM Modem has dual native (native IP and native TDM) signal processing circuit
Adaptive Modulation Radio (AMR) QPSK / 16 QAM/ 32 QAM / 64 QAM / 128 QAM / 256 QAM (6 modulation schemes changing adaptively)
Radio (1+1) Hot standby / Space diversity , (1+1) twin Path (Frequency Diversity)
Protection E1 Ring E1 SNCP (sub network connection protection ) support
LAN Ring RSTP (Rapid Spanning Tree Protocol) support
XPIC
C (CC
(CCDP)) Function
u ct o QPSK
Q S to 256
56 Q
QAM modulation
odu at o at ((14 MHz/28MHz/56MHz),
/ 8 /56 ),
AMR (1+1) and XPIC combination AMR and (1+1), AMR and XPIC combination available
DXC (E1 Cross Connect) Capacity Up to 168 x 168 E1 non blocking
2.048 MHz or 2.048 Mbps external clock input / output, 75 or 120 Ohms selectable, D-Sub 44 pin
External Clock Interface
connector

iPASOLINK Introduction 65
PERFORMANCE – iPASOLINK 200 IDU
ITEM IDU
DCN AND SERVICE CHANNELS
NMS Interface 1 Port, 10/100 Base-T, RJ-45 (in-band or Out-band connections supported)
NE1 1 Ports, 10/100 Base-T, RJ-45
NE2 (RS
(RS-485)
485) 1 Port Serial signal port for legacy equipment ,
Local Craft Terminal (LCT) 1-Port, 10/100 Base-T, RJ -45
HK (Input 6 CH, output 4 CH), Cluster ALM (Input / Output -4) available with optional AUX card, D-Sub 44
House Keeping and Cluster Alarms
pin
2 Ports , RS -232C, 9.6 Kbps Async. D-sub -44 pin
Service Channels
2 Ports , V.11 ( co-direction or contra-direction) 64 Kbps Sync, D-Sub 44 pin
Engineering Order Wire (EOW) (Back to Back) 2 port 4-wire voice channel, D-Sub 44 pin
Far-End Baseband Loop Back
Loop Back Near-End Baseband Loop Back
IF Loop Back
Manual TX Power Control,
TX Power control Mode
Automatic TX Power Control
PMON Items: OFS, BBE, ES, SES, SEP, UAS
Performance Monitor Metering Items: Output Power Level (TX PWR), Received Signal Level (RSL). Bit Error Rate (BER
LAN Monitoring items: RX Unicast, RX Broadcast, RX Multicast, RX Pause, RX CRC error
POWER REQUIREMENTS AND DIMENSION
Power requirement -48 V DC (-40.5 to -57 VDC) conform to EN300 132-2
IDU without
ith t OOptions
ti (1
(1+0)
0) : 55W,
55W (1+1)
(1 1) 65 W
Power Consumption
AUX option: 5W, 16xE1 option : 5W, STM-1 option: 5W. MSE option: 10W, external Clock option: 3W
Mechanical Dimensions 482 (W), 44(H), 240 (D) mm, 3 Kg approx.
Environmental Condition Workable: -10 to +55 Deg. C,

iPASOLINK Introduction 66
PERFORMANCE – iPASOLINK 400 IDU
ITEM IDU
Channel Spacing 7 MHZ 14 MHz (13.75 MHz ) 28 MHz (27.5 MHz) 56 MHz (55 MHz)
QPSK 14 28 57 114
Transmission 16 QAM 28 56 114 229
Capacity
32 QAM 35 71 143 287
andd
Channel spacing 64 QAM 45 85 172 345
128 QAM 49 99 200 402
256 QAM - 114 229 460
[[Band width within p
parenthesis is Channel Spacing
p g at 18 Ghz band ] [capacity
[ p y is physical
p y layer
y maximum throughput
g p at 64 bytes
y p
packet size]]
E1 16xE1 (G703) MDR 68 connector in main board (64 E1 with additional 16 E1 Universal Cards)
2 x 10/100 Base-T(X) RJ-45 connector (up to 2 x 10/100/1000 Base –T available with software upgrade)
Main Signal Interface LAN
2 x 1000 SX or LX with SFP modules (connector type LC)
STM-1 1or 2 x STM-1 (S 1.1 or L 1.1 ) option card with software selectable channelized STM-1 (connector type – LC)
Connector Type : TNC female
Inter facility Link (IDU-ODU)
Cable length : Nominal 300m maximum with 8D-FB-E or equivalent performance cable
FUNCTION OUTLINE
Native IP and Native TDM Modem has dual native (native IP and native TDM) signal processing circuit
Adaptive Modulation Radio (AMR) QPSK / 16 QAM/ 32 QAM / 64 QAM / 128 QAM / 256 QAM (6 modulation schemes changing adaptively)
Radio (1+1) Hot standby / Space diversity , (1+1) twin Path (Frequency Diversity), XPIC (1+1)
E1 Ring E1 SNCP (sub network connection protection ) support
Protection
LAN Ring RSTP (Rapid Spanning Tree Protocol) support / ITU-T G.8032
STM-1(APS)
S ( S) Automatic
uto at c p
protection
otect o sswitching
tc g for
o S
STM-1 interface
te ace ((ITU-T
U G.841
G 8 non
o –revertive
e e t e mode)
ode)
XPIC (CCDP) Function QPSK to 256 QAM modulation at (7MHz/14 MHz/28MHz/56MHz),
AMR (1+1) and XPIC combination AMR and (1+1), AMR and XPIC combination available
DXC (E1 Cross Connect) Capacity Up to 168 x 168 E1 non blocking
External Clock Interface 2.048 MHz or 2.048 Mbps external clock input / output, 75 or 120 Ohms selectable, D-Sub 44 pin connector

iPASOLINK Introduction 67
PERFORMANCE – iPASOLINK 400 IDU
ITEM IDU
DCN AND SERVICE CHANNELS
NMS Interface 1 Port, 10/100 Base-T, RJ-45 (in-band or Out-band connections supported)
NE1 1 Ports, 10/100 Base-T(X), RJ-45
NE2 (RS
(RS-485)
485) 1 Port Serial signal port for legacy equipment , available with optional AUX card, D-Sub
D Sub 44 pin
Local Craft Terminal (LCT) 1-Port, 10/100 Base-T(X), RJ -45
House Keeping and Cluster Alarms HK (Input 6 CH, output 4 CH), Cluster ALM (Input / Output -4) available with optional AUX card, D-Sub 44 pin
2 Ports , RS -232C, 9.6 Kbps Async. D-sub -44 pin
Service Channels
2 Ports , V.11
V 11 ( co
co-direction
direction or contra-direction)
contra direction) 64 Kbps Sync
Sync, D
D-Sub
Sub 44 pin
Engineering Order Wire (EOW) (Back to Back) 2 port 4-wire voice channel, available with optional AUX card, D-Sub 44 pin
Far-End Baseband Loop Back
Loop Back Near-End Baseband Loop Back
IF Loop
p Back
Manual TX Power Control,
TX Power control Mode
Automatic TX Power Control
PMON Items: OFS, BBE, ES, SES, SEP, UAS
Performance Monitor Metering Items: Output Power Level (TX PWR), Received Signal Level (RSL). Bit Error Rate (BER)
LAN Monitoring items: RX Unicast, RX Broadcast, RX Multicast, RX Pause, RX CRC error
POWER REQUIREMENTS AND DIMENSION
Power requirement -48 V DC (-40.5 to -57 VDC) conform to EN300 132-2
IDU without Options (1+0) : 55W, (1+1) 65 W
Power Consumption AUX option: 3W, 16xE1 option : 8W, STM-1 option: 8W. MSE option: 10W, external Clock option: 3W
Modem : 10W, 4xGbE : 8W
Mechanical Dimensions 482 (W), 44(H), 240 (D) mm, 3 Kg approx.
Environmental Condition Workable: -10 to +55 Deg. C,

iPASOLINK Introduction 68
PERFORMANCE – iPASOLINK 1000 IDU
ITEM IDU
Channel Spacing 7 MHZ 14 MHz (13.75 MHz ) 28 MHz (27.5 MHz) 56 MHz (55 MHz)
QPSK 14 28 57 114
Transmission 16 QAM 28 56 114 229
Capacity
32 QAM 35 71 143 287
and
Channel spacing 64 QAM 45 85 172 345
128 QAM 49 99 200 402
256 QAM - 114 229 460
[Band width within parenthesis is Channel Spacing at 18 Ghz band ] [capacity is physical layer maximum throughput at 64 bytes packet size]
E1 16 E1 Universal Cards x n
2 x 10/100 Base-T(X) RJ-45 connector (up to 2 x 10/100/1000 Base –T available with software upgrade)
Main Signal Interface LAN 2 x 1000 SX or LX with SFP modules (connector type LC)
10 GbE interfaces up to four
STM-1 1or 2 x STM-1 (S 1.1 or L 1.1 ) option card with software selectable channelized STM-1 (connector type – LC)
CWDM Several GbE/10GbE over single fiber
Inter facility Link (IDU-ODU) Connector Type : TNC female Cable length : Nominal 300m maximum with 8D-FB-E or equivalent
FUNCTION OUTLINE
Native IP and Native TDM Modem has dual native (native IP and native TDM) signal processing circuit
Adaptive Modulation Radio (AMR) QPSK / 16 QAM/ 32 QAM / 64 QAM / 128 QAM / 256 QAM (6 modulation schemes changing adaptively)
Main Board Redundant Main card (TDM/L2 Switch matrix with CPU) (iPASOLINK 1000)
Radio (1+1) Hot standby / Space diversity , (1+1) twin Path (Frequency Diversity), XPIC (1+1)
Protection E1 Ring E1 SNCP (sub network connection protection ) support
LAN Ring RSTP (Rapid Spanning Tree Protocol) support / ITU-T G.8032
STM-1(APS) Automatic protection switching for STM-1 interface (ITU-T G.841 non –revertive mode)
XPIC (CCDP) Function QPSK to 256 QAM modulation at (7MHz/14 MHz/28MHz/56MHz),
AMR (1+1) and XPIC combination AMR and (1+1), AMR and XPIC combination available
DXC (E1 Cross
C C
Connect)
t) C
Capacity
it U tto 168 x 168 E1 non blocking
Up bl ki
External Clock Interface 2.048 MHz or 2.048 Mbps external clock input / output, 75 or 120 Ohms selectable, D-Sub 44 pin connector

iPASOLINK Introduction 69
PERFORMANCE – iPASOLINK 1000 IDU
ITEM IDU
DCN AND SERVICE CHANNELS
NMS Interface 1 Port, 10/100 Base-T, RJ-45 (in-band or Out-band connections supported) ,TERM-M card
NE1 1 Ports, 10/100 Base-T(X), RJ-45, TERM-M Card
NE2 (RS
(RS-485)
485) 1 Port Serial signal port for legacy equipment , available with optional AUX card, D-Sub
D Sub 44 pin
Local Craft Terminal (LCT) 1-Port, 10/100 Base-T(X), RJ -45 (Main Board)
House Keeping and Cluster Alarms HK (Input 6 CH, output 4 CH), Cluster ALM (Input / Output -4) available with optional AUX card, D-Sub 44 pin
RS -232C 9.6 Kbps Async :- 1 Ports , D-sub -44 pin, 1 -Port TERM-M card
Service Channels
V 11 ( co
V.11 co-direction
direction or contra
contra-direction)
direction) 64 Kbps Sync ::- 1 Ports D
D-Sub
Sub 44 pin,
pin 11-Port
Port TERM
TERM-M
M card
Engineering Order Wire (EOW) (Back to Back) 2 port 4-wire voice channel, available with optional AUX card, D-Sub 44 pin
Far-End Baseband Loop Back
Loop Back Near-End Baseband Loop Back
IF Loop
p Back
Manual TX Power Control,
TX Power control Mode
Automatic TX Power Control
PMON Items: OFS, BBE, ES, SES, SEP, UAS, E1 code violations
Performance Monitor Metering Items: Output Power Level (TX PWR), Received Signal Level (RSL). Bit Error Rate (BER)
LAN Monitoring items: RX Unicast, RX Broadcast, RX Multicast, RX Pause, RX CRC error
POWER REQUIREMENTS AND DIMENSION
Power requirement -48 V DC (-40.5 to -57 VDC) conform to EN300 132-2
IDU without Options (1+0) : 55W, (1+1) 65 W
Power Consumption AUX option: 3W, 16xE1 option : 8W, STM-1 option: 8W. MSE option: 10W, external Clock option: 3W
Modem : 10W, 4xGbE : 8W
Mechanical Dimensions 483 (W), 132(H), 240 (D) mm, 15 Kg approx.
Environmental Condition Workable: -10 to +55 Deg. C,

iPASOLINK Introduction 70
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
QPSK 29 29 25 25 25 24 24 23 22 22 20 20
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
QPSK ( 56 MHz) -84.5 -84.5 -84.0 -83.5 -83.5 -83 -83.5 -82.5 -82.5 -82.5 -81.5 -79.5
QPSK ( 28 MHz) -87.5 -87.5 -87 -86.5 -86.5 -86 -86.5 -85.5 -85.5 -85.5 -84.5 -82.5 Guaranteed TX Power
QPSK ( 14 MHz) -90.5 -90.5 -90 -89.5 -89.5 -89 -89.5 -88.5 -88.5 -88.5 -87.5 -85.5 6-28 GHz +/- 1.5dB
QPSK ( 7 MHz) -93.5 -93.5 -93 -92.5 -92.5 -92 -92.5 -91.5 -91.5 -91.5 -90.5 -88.5 32-38 GHz +/-2.5 dB
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
QPSK ( 56 MHz) 113.5 113.5 109 108.5 108.5 107 107.5 105.5 104.5 104.5 101 99.5
QPSK ( 28 MHz) 116.5 116.5 112 111.5 111.5 110 110.5 108.5 107.5 107.5 104.5 102.5
Guaranteed Threshold
QPSK ( 14 MHz) 119.5 119.5 115 114.5 114.5 113 113.5 111.5 110.5 110.5 107.5 105.5
Rx Threshold at 10-6 BER
QPSK ( 7 MHz) 122.5 122.5 118 117.5 117.5 116 116.5 114.5 113.5 113.5 110.5 108.5
Max input level - 20 dBm for BER less than 10-3 6-38 GHz +3 dB

Transmit Power - Measured at ODU TX port


16 QAM 26 26 22 22 22 21 21 19 18 18 17 16 56 MHz
MH
16 QAM 27 27 23 23 23 22 22 20 19 19 18 17 7MHz/ 14 MHz / 28 MHz

Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
16 QAM ( 56 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73

16 QAM(( 28 MHz)) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
16 QAM ( 14 MHz) -84 -84 -83.5 -83 -83 -82.5 -83 -82 -82 -82 -81 -79
16 QAM ( 7 MHz) -87 -87 -86.5 -86 -86 -85.5 -86 -85 -85 -85 -84 -82
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
16 QAM ( 56 MHz) 104 104 99.5 99 99 97.5 98 95 94 94 92 89
16 QAM( 28 MHz) 108 108 103.5 106 106 104.5 105 102 101 101 99 93
16 QAM ( 14 MHz) 111 111 106.5 106 106 104.5 105 102 101 101 99 96
Guaranteed System Gain
16 QAM ( 7 MHz) 114 114 109.5 109 109 107.5 108 105 104 104 102 99
6-28 GHz -3 dB
Max input level - 20 dBm for BER less than 10-3
32-38 GHz -4 dB

iPASOLINK Introduction 71
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
32 QAM 25 25 21 21 21 20 18 18 18 18 17 16 56 MHz
7MHz/ 14 MHz / 28
32 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
32 QAM ( 56 MHz) -75
75 -75
75 -74.5
74.5 -74
74 -74
74 -73.5
73.5 74 -73
73 -73
73 -73
73 -72
72 -70
70
32 QAM( 28 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73
32 QAM ( 14 MHz) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
32 QAM ( 7 MHz) -84 -84 -83.5 -83 -83 -82.5 -83 -82 -82 -82 -81 -79
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
32 QAM ( 56 MHz)
MH ) 100 100 95 5
95.5 95 95 93 5
93.5 92 91 91 91 89 86
32 QAM( 28 MHz) 104 104 99.5 99 99 97.5 96 95 95 95 93 89
32 QAM ( 14 MHz) 107 107 102.5 102 102 100.5 99 98 98 98 96 92
32 QAM ( 7 MHz) 110 110 105.5 105 105 103.5 102 101 101 101 99 95
Transmit Power - Measured at ODU TX port

64 QAM 25 25 21 21 21 20 18 18 18 18 17 15 56 MHz
7MHz/ 14 MHz / 28
64 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
64QAM ( 56 MHz) -72 -72 -71.5 -71 -71 -70.5 -71 -70 -70 -70 -69 -67

64 QAM( 28 MHz)
MH ) -75
75 -75
75 -74.5
74 5 -74
74 -74
74 -73.5
73 5 -74
74 -73
73 -73
73 -73
73 -72
72 -70
70
64 QAM ( 14 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73
64 QAM ( 7 MHz) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
64 QAM ( 56 MHz) 97 97 92.5 91 91.5 90.5 88.5 88 88 86.5 85.5 82
64 QAM( 28 MHz) 101 101 96.5 96 96 94.5 93 92 92 92 90 86
64 QAM ( 14 MHz) 104 104 99.5 99 99 97.5 96 95 95 95 93 89
64 QAM ( 7 MHz) 107 107 102.5 102 102 100.5 99 98 98 98 96 92
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB

iPASOLINK Introduction 72
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
128 QAM 25 25 21 21 21 20 18 18 18 18 17 15 56 MHz
7MHz/ 14 MHz / 28
128 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
128 QAM ( 56 MHz) -69
69 -69
69 -68.5
68 5 -68
68 -68
68 -67.5
67 5 -68
68 -67
67 -67
67 -67
67 -66
66 -64
64
128 QAM( 28 MHz) -72 -72 -71.5 -71 -71 -70.5 -70.5 -71 -70 -70 -69 -67
128 QAM ( 14 MHz) -75 -75 -74.5 -74 -74 -73.5 -74 -73 -73 -73 -72 -70
128 QAM ( 7 MHz) -77.5 -77.5 -77 -76.5 -76.5 -76 -76.5 -75.5 -75.5 -75.5 -74.5 -
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
128 QAM ( 56 MHz) 94 94 89.5 89 89 87.5 86 85 85 85 83 79
128 QAM( 28 MHz) 98 98 93.5 93 93 91.5 90 89 89 89 87 83
128 QAM ( 14 MHz) 101 101 96.5 96 96 94.5 93 92 92 92 90 86
128 QAM ( 7 MHz) 103 103 98 98 98.5 97.5 95.5 95 95 93.5 92.5 -
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB
Transmit Power - Measured at ODU TX port

24 24 20 20 20 19 17 17 17 17 16 14 56 MHz
7MHz/ 14 MHz / 28
25 25 21 21 21 20 18 18 18 18 17 15
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
256QAM ( 56 MHz)
MH ) -65.5
65 5 -65.5
65 5 -65
65 -64.5
64 5 -64.5
64 5 -64
64 -64.5
64 5 -63.5
63 5 -63.5
63 5 -63.5
63 5 -62.5
62 5 -60.5
60 5

256 QAM( 28 MHz) -68.5 -68.5 -68 -67.5 -67.5 -67 -67.5 -66.5 -66.5 -66.5 -65.5 -63.5
256 QAM( 14 MHz) -71 -71 -70.5 -70 -70 -69.5 -70 -69 -69 -69 -68 -
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
256QAM ( 56 MHz) 89.5 89.5 85 84.5 84.5 83 81.5 80.5 80.5 80.5 78.5 74.5
256 QAM( 28 MHz) 93.5 93.5 89 88.5 88.5 87 85.5 84.5 84.5 84.5 82.5 78.5
256 QAM( 14 MHz) 96 96 91.5 91 91 89.5 88 87 87 87 85 -
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB

iPASOLINK Introduction 73
iPASOLINK
OUT DOOR UNIT

iPASOLINK Introduction 74
OUT DOOR UNIT (ODU)

UP CONV RF AMP

LO
TX RF
BPF
MPX
DOWN CONV

RX RF
LNA BPF

CONTROL

DC-DC CONV

iPASOLINK Introduction 75
OUT DOOR UNIT (6
(6-11 GHz) IHG

HANDLE

RF IN/OUT COAXIAL TYPE (6-8 GHz)

Label

RX LEV MONITOR
IF IN/OUT

Turn OFF the IDU DC


power before removing
the IF cable
Frame Ground RF IN/OUT WG TYPE (6-8 GHz)

iPASOLINK Introduction 76
♦ OUT DOOR UNIT (13
(13-
-38 GHz) IHG
HANDLE

RF IN/OUT 13 – 38 GHz

TRP-15G 1D (IHG)

Frame Ground

IF IN/OUT
Turn OFF the IDU DC
power before removing
the IF cable

RX LEV MONITOR

iPASOLINK Introduction 77
TYPICAL ODU BLOCK DIAGRAM
TX 350 MHz
TX: MH
RX: 140 MHZ
350 MHz
DC: -48V

IF INPUT ALM TX PWR ALM

RX LEV ALM

Input IF signal consists of:


Each of the input IF signal components are separated in the MULTIPLEXER using
•350 MHz TX IF
separation
p filters. DC voltage
g is supplied
pp to the DC-DC CONV to p produce
•10MHz Control regulated DC voltages required in the ODU.
•DC power -48V The 10 MHz control signal which is ASK modulated is sent to the Control circuit,
Output IF signal consists of: where the ODU controls like TX Power, RF Frequencies etc. are implemented. The
Alarms in ODU are collected in the Control module and sent to the IDU using the
•140 MHz RX IF
ASK modulated 10 MHz signal.
signal
•10MHz Alarm/Response

iPASOLINK Introduction 78
ODU Compatibility

iPASOLINK 400

NHG2 (Existing only)

iPASOLINK 200

IHG
(Supplied with iPaso)

iPASOLINK 1000

iPASOLINK Introduction 79
PERFORMANCE - ODU
ITEM OUT DOOR UNIT
iPASOLINK High Grade (IHG) type ODU
Power Consumption (1+0) (1+1)
6 – 11 GHz 30W Hot standby: 45W, Twin path: 60W
13 -26,
26, 28, 32,and 38 GHz 23 W Hot standby: 38W, Twin path: 46W
Mechanical Dimensions
6-11 GHz 237(W), 237(H), 101 (D), 3.5 Kg
239(W), 247(H), 68 (D), 3 Kg
13-38GHz

EMC Conforms to EN301 489-4


Safety Conforms to EN60950-1
Environmental Condition Operation: -33 to +50deg.C, (ETSI EN301019-1-4 class 4.1), Humidity: 100% (IP66)
Workable: -40 to +55 deg.C
Transportation ETSI EN301019-1-2 class 2.3
Storage ETSI 201019-1-1 class 1.2

iPASOLINK Introduction 80
Enhanced Radio Performances with new ODU (IHG)

100
Enhanced System Gain
High System Gain 90 (256QAM/56MHz)

S y s te m G a in (d B )
•High System Gain achieved by Low Density Parity
Check ((LDPC)) Forward Error Correction ((FEC)) 80
technology and distortion canceling technique
called linearizer allowing smaller antennas and
70
reducing platform cost.

60

50
6 7 10 13 15 18 23 26 32 38
Frequncy(GHz)

NEO HP with NHG2 iPASOLINK with IHG

iPASOLINK Introduction 81

You might also like