Instructions of Hangzhou Jialong Air equipment Co., Ltd.

1. Overview

The principle and working process

The compressed air enters the oil filter firstly to remove most of the

liquid water and oil (oil removing precision 0.01ppm), Before entering the

cold dry cooling machine and cooling of dry compressed air by the heat

exchanger, the dry compressed air temperature, while decreasing the

temperature of the compressed air into the evaporator, removing a

portion of the water, making it to ambient temperature, reduce the work

load of evaporator. Before entering the evaporator heat exchange, so that

the compressed air cooling to 5 ℃ dew point temperature. The

compressed air in the most part of the impurities in water and by

condensation, gas water separator to separate air and water, Then the

moisture, oil by the automatic drain discharge, dry compressed air is

returned to the Leng Gan machine precooler, to cool the hot and humid

air, the temperature is increased, the dry compressed air can also

prevent condensation pipelines at the same time after heating. After

freeze dry compressed air then enters the dryer adsorption dryer, further

to remove moisture to the dew point temperature to meet the

requirements. From the dry compressed air dryer out again through the

dust filter to remove dry machine produced little dust is transported to the

user, while exports from the dryer and a portion of the compressed air

into the regeneration tower regeneration.(Tepefaction regeneration type: