S 100-2
Belt Driven Screw Compressor
Air Circuit
Function Description
Oil circuit
Function of Oil Injection
Load Operation
Delivers maximum amount of compressed air consuming maximum
energy.
Idling Operation
Compressor runs but does not deliver any compressed air.
It consumes 75 % less energy than In load operation.
Standstill ready for Operation
Compressor is standing still but ready for operation
13 IA Compressor Mode of Operation
Sl Consumables Frequencies
No
1 Compressor oil (Syprem 8000s) 9000 hrs
2 Supply Air filter 500 hrs
The safety temperature limiting device switches off the compressor once
the maximum admissible final compression temperature has been
reached.
The compressor does not switch on when dropping below the minimum
temperature.
Switch off the compressor (OFF button). Fault is acknowledged.
Rectify the fault.
Switch on the compressor (ON button).
Safety Valve
For a given pressure, the temperature at which water vapor will begin to
condense into liquid water
Class 4:
The lowest pressure dew point class for a refrigerated dryer is Class 4. Class 4
delivers a pressure dew point of +38°F. Refrigerated dryers should not operate
below the Class 4 range because the water vapor will freeze in the dryer.
Class 6:
The highest pressure dew point for a refrigerated dryer is Class 6. Class 6 delivers
a pressure dew point of +50°F. The highest practical pressure dew point because
higher pressure dew point causes condensation in downstream piping.
Refrigeration drying.
Properties
R-407 C is a non-ozone depleting bend of three refrigerant R-
32,R-125,R-134 A.(23/25/52 % by weight)
Non flammable & safe to use.
Environmentally Accepted.
Commercially Available.
Adsorption Drying
Water vapor contained in the air is corrosive and can affect your
compressed air network, solenoid valves, pneumatic equipment
etc.
Dust and other contaminants can reduce the working life of your
pneumatic equipment, resulting in premature breakdowns and
higher maintenance costs.
Adsorption
Regeneration
Standby
Adsorption
Regeneration(Running in parallel to
adsorption)
At the same time the other vessel is prepared for a renewed take-up
of humidity. This is called regeneration.
With the dew point sensing control option, the regeneration phase is
followed by a standby phase.
The regeneration phase is sub divided into 3 phases:
Expansion Phase
Dehumidification Phase
Pressure Build-up Phase
Expansion & Dehumidification Phase
Pressure Build-up Phase
Standby Phase & Switchover
Standby Phase
When in standby phase the fully regenerated vessel is ready for
adsorption operation. The system is switch to this vessel, as soon as
the measured dew point at the compressed air has reached the set dew
point value for switch over.
Switchover
When the drying agent in the adsorbing vessel has taken up a
sufficient level of
humidity ,then the switch over between the vessels will be effected
between the vessel.
Display Panel
1. LED power
2. Flow diagram
3. Digital display
4. LED economy cycle
Flow Diagram
Cyclone Separator Principle