G U L UL GL GU GUL
ZTE FDD GUL SDR Base Station Overview
Macro

B8200 B8901B

BS8908 Component – BBU

RSU RRU AAU


BS8900B BS8900A BS8800 BS8800 BS8906 BS8700
Component – RF Module
Small Cell
BBU BBU
pBridge
BS8922 pBridge
BS8912 pBridge
Cable
pBridge pRRU
Fiber
pBridge
BS8112 BS8102 QCell Components
© ZTE Corporation. All rights reserved
3
G U L UL GL GU GUL
ZTE FDD GUL SDR Base Station Family
Baseband Unit Macro BS Compact BS Small Cell Multi-Mode

QCell Full Bandwidth


Indoor B8200
Outdoor BS8908
BS8912 BS8922
Ultra Broad Band
R8119/R8129+PB1120A
Pad BBU Outdoor Indoor R8108+PB1000 Miniaturization
Outdoor B8901B BS8900A BS8900B BS8800 Outdoor BS8906 BS8112 BS8102 MA1020

High Power
RSU RRU AAU

1T 2T 1T 2T 3T 4T AAU High Efficiency

Multi-PA
RSU40 RSU82 R8861 R8862/A R8872A R8852/E
High Integration
Pad RRU iMacro
RSU60E RSU72 R8881 R8882
R8402/
R8892E/N R8412 R8863 R8854/D A8602 A8290 A8292A Innovation
© ZTE Corporation. All rights reserved
4
ZTE FDD GUL SDR Base Station Introduction
Type Scenario
Scenario BS
BS Feature&&Application
Feature Application Component
Component Solution
Solution
Large capacity; All IP structure; High reliability;
Indoor BS8800 B8200+RSU GUL
Rich interfaces; Smooth evolution; Used for macro coverage
All-in-one solution in one rack; 2–8 hours battery backup; Large
BS8900B B8200+RSU GUL
capacity; Smooth evolution; Used for macro coverage
M
BS8900A Modularized design; All in one outdoor site solution; 2–8 hours battery
A backup; Large capacity; Smooth evolution; Used for macro coverage
B8200+RSU GUL
C
Macro Outdoor
Strong adaptation to tough environments; Fast deployment; Used for
R BS8906
complementary coverage
B8200+RSU GUL/GU
O
Low power consumption; Flexible networking; Compact design;
BS8908 Integrated G
Natural cooling; Used for GSM rural area or blind area
Small and light, easy for installation; Fast deployment; Flexible B8200+RRU
Distributed
BS8700 networking; Saving project cost and decreasing construction time; B8200+AAU GUL
Indoor/Outdoor
Used when the site acquisition is difficult or room rental is expensive B8901B+RRU
L/U mode sharing the same hardware; Supporting 2*2 MIMO;
Outdoor BS8912/BS8922 Integrated U/L
Small
Small Small volume, large capacity; Used for hot spots or blind areas
Cell
Cell Quite Cute; Quad Band; Quick Deployment; Quality Assurance; Used
Indoor QCell BBU+pBridge+pRRU UL
for indoor coverage, supporting high U/L data throughput

© ZTE Corporation. All rights reserved


5
ZTE FDD GUL SDR Base Station Application Scenarios
 Large capacity
 Outdoor all in one
solution Indoor Macro BS
 U/L high data throughput
 Simple deployment Micro BS Macro Coverage
 Low cost Hot Spots
& Blind Areas

Outdoor Macro BS QCell


CBD

Macro Coverage Indoor


Coverage

Buildings
 Medium capacity
 Fast installation
 Large capacity
 Coordination with Macro
 Indoor machine
room is available
Parks Buildings

© ZTE Corporation. All rights reserved


6
Agenda

Overview

2 ZTE SDR Product Introduction


ZTE LTE Proposal for VNPT

Success Cases
GUL
Distributed BS — ZXSDR BS8700
BS8700
Antenna
BBU

BB
CPRI
FS RRU
RadioUnit
Radio Unit

E1 SA/
SE/ Fiber
STM-1 NIS CC

GE/FE

Control Signaling
Clock
Data

+
B8200 R8881 R8882 R8861 R8862 R8862A R8872A R8892E R8402

BS8700 contains two separate modules:


baseband unit and remote radio unit . R8863 R8854 A8602 A8290 A8200 A8808

© ZTE Corporation. All rights reserved


8
GUL
Base Band Unit — ZXSDR B8200
Based on Unified MicroTCA Platform Specification
L: 36*20M Cells (6*20M 4*4 MIMO Cells * 6 BPs)
10800 RRC_connnected users
Capacity U: 60 CSs, DL 5120 CEs/UL 5120 CEs
G: 360 TRXs
88.4mm GUL: L 12*20M Cells + U 24 CSs + G 144 TRXs
197mm
L: DL: 7.2Gbps / UL: 2.7Gbps
Data Throughput
482.6mm U: DL: 1Gbps / UL: 690Mbps
L : 85W (6*20M Cells)
Typical Power
U: 85W (6CSs), 110W (12 CSs)
 GUFTN multi-mode supporting  Large capacity Consumption
G: 65W (12 TRXs), 80W (24 TRXs)
 Dual-CC for different modes  Rich interfaces
Power Supply -48V DC
 Low power consumption  Smooth evolution
Temperature
-20℃ to + 55℃
Range
Abis/Iub/S1/X2 8 E1/T1+1 GE optical or 1 GE/FE electrical/CC16B
interface Or 2*10GE Optical + 2*GE Electrical/CCE1
BBU to RU
6 CPRI interfaces per FS/BPN0/BPN2
interface

Volume (H*W*D) 88.4 mm*482.6 mm*197 mm

Weight 8.75 kg (full configuration)

© ZTE Corporation. All rights reserved


9
GUL
ZXSDR B8200 Boards & Performance
 Dual-CC for different modes to
process the signaling storm
PM FS

FAM
Modularized BP High  GUFT multi-mode achieved by
Design Reliability
SA CC hardware and software
configuration
Module Name Shared by GUL Min/Max Configuration Comments  Large capacity and modularized
design, easy to expand
CC Board Y 1/2 B8200 control and clock
 Baseband resources are pooled
FS Board Y 1/2 RRU/RSU aggregation
among multiple BP boards
BP Board Y 1/6 GUL single mode or multi-mode  All IP structure, supporting
SA/SE Board Y 1/2 Dry contacts & E1&T1 future smooth evolution
UES Board Y 0/1 Sync E & L2 Ethernet Switch  Various interfaces, supporting
flexible networking
TAM Y 0/2 TMA control
 High reliability , supporting 1+1
UCI Board Y 0/1 Remote GPS or Glonass Clock
or load sharing backup
PM Y 1/2 Power supply  Low power consumption, energy
FAM Y 1/1 Internal fans for cooling saving

© ZTE Corporation. All rights reserved


10
GUL
Control & Clock (CC) Board
CC2 CC16B CCE1

CC Type CC2 CC16B CCE1


G/U single mode or dual- G/U/L single mode or multi- GUL multi-mode/LTE single
Mode
mode mode mode
UMTS CNBAP Processing
400/s 1500/s 3000/s
Capability
10800 RRC_connected users 10800 RRC_connected users
LTE Processing Capability N/A
UL 900Mbps/ DL 900Mbps UL 1.8Gbps/ DL 3.6Gbps

Control & Clock Board


 GPS system clock & BITS clock & SyncE clock & interface recovery clock

 Abis/Iub/S1/X2 interface protocol processing

 Ethernet switch function, providing switch plan for signaling and media stream
 System management

© ZTE Corporation. All rights reserved


11
G U L GUL
Baseband Processing (BP) Board
UBPG BPK BPL BPN

Universal Baseband Processing Board for GSM (UBPG/UBPG3)


Board UBPG UBPG3
TRX 12 24
Baseband Processing Board for UMTS (BPK_e1/BPK_e/BPK_d)
Board BPK_e1 BPK_e BPK_d
Cells 6 6 12
CE No. DL192CE/UL192CE DL384CE/UL384CE DL768CE/UL768CE
Data Throughput DL129.6Mbps/ DL259.2Mbps/ UL69Mbps DL518.4Mbps/ UL138Mbps
UL34.5Mbps
Baseband Processing Board for LTE (BPN0A/BPN0)
Board BPN0A BPN0
CPRI Interfaces 6 pairs 6 pairs
RRC_connected Users 3600 3600
Cells (20M, 2T2R/2T4R) 3 6
Cells (20M, 4T4R) N/A 3
Data Throughput DL450Mbps/ UL225Mbps DL600Mbps/ UL300Mbps

Multi-Mode Baseband Processing Board (BPN2A/BPN2)


Mode BPN2
12 TRXs + 12 CSs(768CEs) or 24 TRXs + 9 CSs(640CEs)
GU
or 36TRXs + 6 CSs(512CEs) or 48TRXs + 6 CSs(256CEs)
GL 36 TRXs + 6 20M Cells (2T4R)
UL 6 CSs(512CEs) + 6 20M Cells (2T4R)
GUL 12 TRXs + 6 CSs(256CEs) + 6 Cells or 24 TRXs + 3 CSs(128CEs) + 6 Cells

© ZTE Corporation. All rights reserved


12
GUL
Site Alarm/Site alarm Extension (SA/SE) Board
SA0/SA3 SE0/SE2

SA0/SE0 SA3/SE2
8 E1/T1 interfaces 4 E1/T1 interfaces
6+2 dry contacts (6 input, 2 bidirectional) 14+2 dry contacts (14 input, 2 bidirectional)
1 RS485 interface 1 RS485 interface
1 RS232 interface 1 RS232 interface

Site Alarm Board/Site Alarm Extension Board (Optional)


 Fan rate control

 Site alarm monitoring and interface lightning protection for the rack
SA Cable
 A-- Connected to SA board
 B1--DB-44, providing 8*E1/T1
 B2--DB-9, RS232/RS485 connector
 B3--DB-25, dry-contact connector
 B4--Grounding cable

© ZTE Corporation. All rights reserved


13
GUL
Power Module (PM) Board

PM3

Interface Name Description


MON Debugging interface, RS232 interface
-48V/-48VRTN -48V input
ON/OFF Power switch, turning on/off 12V power to/from BBU

PM5 Power Module


 16 internal interfaces for +12V, +13V and +28V load power
 16 internal interfaces for +3.3V management power
 Measurement and protection of inputing over-voltage/under-voltage
 Output over-current protection and load power management
 PM5 has 50% more power supply than PM3 for full configuration of new high power
consumption boards

© ZTE Corporation. All rights reserved


14
L GL UL GUL
Remote Radio Unit — ZXSDR R8862A
Specification
G/U/L: 8 TRXs/8 Carriers/2*20M Cells
Capacity GL: 6 TRXs+1*20M Cell@1800M
422 mm

422 mm
UL: 4 Carriers (non-MIMO) + 1*20M Cell

2*60W@AP700/850/900/1800/2100/2600MHz/AWS
Max TOC
2*40W@2.6GHz

TxRx 2T4R

Typical Power GL: 245W (G S4 + L S1, 1800MHz)


Consumption L: 220W(1800MHz) 210W(2100MHz) 215W(2600MHz)

 Small size, easy installation  Enhanced uplink sensitivity G:-113.5dBm@single antenna


Receiver Sensitivity L: -109.2dBm@dual antennas
 Supporting 2T4R, MIMO capable  Covering the full band -112dBm@four antennas

Power Supply -48V DC, 220V/110V AC


B1:2100MHZ 60MHZ
Interface 2*6 Gbps CPRI interfaces
B3:1800MHZ 75MHZ
Frequency band AP700/850/900/1800/2100/2600 MHz/AWS
B5:850MHZ 25MHZ
Protection Class IP65
B7:2600MHZ 70MHZ IM3 interference is diminished through
ZTE innovative solution with port 1 and Temperature Range -40℃ to +55℃
B8:900MHZ 35MHZ
4 configured in TX mode only and port
45MHZ Except AP700: 422 mm*218 mm*133 mm(12L)/15 kg
B28:AP700 2 and 3 in RX mode only. Volume/Weight
AP700: 422 mm*218 mm*168 mm(15L)/17 kg
Supporting Full Bandwidth No PIM interference
© ZTE Corporation. All rights reserved
15
L GL UL GUL
ZXSDR R8862A Interface Indices
1 2
No. Label Interface Interface Type/Connector

AISG equipment interface


MON external monitoring
1 AISG/MON DB15 connector
interface
LMT O&M Ethernet interface
16 mm2 yellow-green
2 GND Protective grounding interface round
terminal

3 ANT1 (TX/RX) TX/RX antenna interface 50 Ω DIN-mode connector

3 4 5 6 4 ANT2 (RX) RX antenna interface 50 Ω DIN-mode connector

5 ANT3 (RX) RX antenna interface 50 Ω DIN-mode connector


10
6 ANT4 (TX/RX) TX/RX antenna interface 50 Ω DIN-mode connector
Interface for communication
LC-type optical interface
7 OPT1 between the RRU and a BBU,
71 (IEC 874)
82 or RRU cascading interface
LC-type optical interface
93 8 OPT2 RRU cascading interface
(IEC 874)
2-pin customized
9 PWR Power input interface
connector
Maintenance Maintenance LED
10 indicate the operating status of the RRU
window open window close indicators
© ZTE Corporation. All rights reserved
16
L GL UL GUL
ZXSDR R8862A Transmission and Work Environment
R8862A is connected to BBU through CPRI interfaces
Item Value Interface Speed Standard
Type
CPRI interface 2 SFP (LC) 6.144Gbps [] CPRI V4.2

Working Environment Indices


Item Characteristics
Temperature -40 to +55 degree
Relative Humidity 5% to 100%
Waterproof/Dustproof IP65
≤5 Ω; earth resistance can be less than 10 Ω in thunder-
Ground less area where thunderstorm days is less than 20 per
year.

Electromagnetic Compatibility Indices


Item Characteristics
Static Discharge Contact Discharge: ±6000V
Immunity Air Discharge: ±8000V
Surge Impact
DC Power port Line(Ground): ±2000V
Immunity
© ZTE Corporation. All rights reserved
17
L GL
Remote Radio Unit — ZXSDR R8854
Specification
L: 2*20M cells (2T2R/2T4R/4T4R)
Capacity
GL: 8 GSM TRXs +1*20M Cell (4T4R)
Max TOC 4*40W
TxRx 4T4R
415 mm

290W (L S2 4*4 MIMO, 4*20W/cell, 1800MHz)


Typical Power
315W (L S2 4*4 MIMO, 4*20W/cell, 2600MHz)
Consumption
320W(G S8+L S1 4*4 MIMO, 10W/TRX, 4*20W/cell, 1800MHz)
G: -113.5dBm@single antenna
-118.6dBm@four antennas
Receiver Sensitivity
L: -112dBm@four antennas, 1800MHz
-111.6dBm@four antennas, 2600MHz
 Supporting 2*2T2R/2T4R/4T4R cells
Power Supply -48V DC
 Supporting full working bandwidth
Interface 2*10Gbps CPRI interfaces
 Small and light, faster deployment
Frequency band 1800/2600 MHz
 Natural cooling and high reliability
Protection Class IP65
4*4 MIMO Ready Temperature Range -40℃ to +55℃
R8854 R8854 R8854 Volume (H*W*D) 415mm*296 mm*104 mm
Weight 17kg

One RRU supports ,


saving 3 RRUs compared with the traditional solution
© ZTE Corporation. All rights reserved
18
L GL UL GUL
ZXSDR R8854 Interface Indices
Interface
No. Label Interface
Type/Connector
AISG equipment interface
MON external monitoring
1 AISG/MON DB15 connector
interface
LMT O&M Ethernet interface
1 2 16 mm2 yellow-green
2 GND Protective grounding interface round
Terminal
ANT1 TX/RX antenna interface 50 Ω DIN-mode
3
(TX/RX) Built-in NSBT connector
ANT2 50 Ω DIN-mode
4 TX/RX antenna interface
(TX/RX) connector
ANT3 50 Ω DIN-mode
5 TX/RX antenna interface
7 (TX/RX)
ANT4
connector
50 Ω DIN-mode
8 6
(TX/RX)
TX/RX antenna interface
connector
Communication between RRU and BBU, LC-type optical interface
3 4 5 6 9 7 OPT1
or RRU cascading interface (IEC 874)
LC-type optical interface
8 OPT2 RRU cascading interface
(IEC 874)
2-pin customized
9 PWR Power input interface
connector

© ZTE Corporation. All rights reserved


19
L GL UL GUL
ZXSDR R8854 Transmission and Work Environment
R8854 is connected to BBU through CPRI interfaces

Interface
Item Value Speed Standard
Type
CPRI interface 2 SFP (LC) 9.8 Gbps CPRI V5.0

Working Environment Indices


Item Characteristics
Temperature -40 to +
Relative Humidity 5% to 100%
Waterproof/Dustproof IP65
≤5 Ω; earth resistance can be less than 10 Ω in thunder-
Ground less area where thunderstorm days is less than 20 per
year.

Electromagnetic Compatibility Indices


Item Characteristics
Static Discharge Contact Discharge: ±6000V
Immunity Air Discharge: ±8000V
Surge Impact
DC Power port Line(Ground): ±2000V
Immunity

© ZTE Corporation. All rights reserved


20
GUL
Diverse Types of BS8700 in GUL Multi-Mode Multi-Band
G S444 + U S111@900MHz
Antenna G S666 + L S111@1800MHz

Feeder
R8863 R8863
Antenna
R8863 Feeder
R8862 R8862 R8862
U S444 + L S111
@ 2.1GHz
Feeder Fiber Antenna
R8854 R8854 R8854

Fiber Feeder

L S222@1800MHz
Fiber 4*4 MIMO

Fiber

© ZTE Corporation. All rights reserved


21
U L
Outdoor Micro BS — ZXSDR BS8922
Front Reverse

BS8922 290m
Integrated
m Antenna

Index: Highlights:
 Both Indoor and Outdoor Applications
 Smallest & lightest outdoor Micro Base Station in industry:
 Large Capacity and Easy Expansion
7L, 8Kg  Compact Design, Light Weight, Fast
 2*5W, 2T2R Deployment
 Green eNodeB
 Support L1800,L2100
 Smooth Evolution to LTE-A
 Support dual carrier, enhance throughput

 Cascade of pad RRU, CA possible


 Zero noise pollution

 Suppport FE/GE interface

© ZTE Corporation. All rights reserved


22
BS8922 Main Application Scenarios
Hotspots, blind areas or indoor coverage With external antenna or not

U L U L
 In CBD or shopping mall  Integrated antenna (9.5dBi), easy
 Blind areas in macro network installation
 Indoor coverage with zero noise  External antenna enhances the
 On the wall or pole coverage

Cascaded with BS8922 Cascaded with R8862s

L U L
…  Supporting 6-level BS cascade,
 Supporting RRU cascade
flexibly networking
 LTE: 3-level cascade
 Saving transmission resource
 UMTS: 4-level cascade
 Extending coverage

BS8922 supports external antenna and RRU/BS cascade and supports CA (LTE) or
DC/MC (UMTS), making a high-quality coverage solution together with macro BSs.
© ZTE Corporation. All rights reserved
23
L GL UL GUL
ZXSDR BS8922 Interface Indices
No. Label Description Interface Type

Power interface, providing AC/DC options. DC: DC power cable


1 PWR DC power interface: -48V power input; AC: 3-pin aerial socket
AC power interface: 220/110V power input (male)

9 2 Protective grounding interface

Environment monitoring interface,


3 MON DB15
providing 2 dry contacts and 1 RS485
8P8C bending type PCB
Electrical interface for transmission, used
4 ETH welding iron yoke with
for Ethernet cable
shrapnel socket

5 GPS GPS antenna interface N type (female)

6 OPT1 Optical interface for transmission SPF(LC)

7 OPT2 Optical interface for cascading SPF(LC)

5-core mini USB


8 USB USB interface for site launch
connector
ANT1 TX/RX
9 Transmitting/receiving antenna feeder interface N-mode connector
ANT2 TX/RX

© ZTE Corporation. All rights reserved


24
L GL UL GUL
ZXSDR BS8922 Interface Indices
Interface
No Label Meaning
Type/Connector

1 RUN Operating status indicator LED Indicator

2 ALM Alarm indicator LED Indicator

3 OPT1/ETH Status of optical interface 1/ETH LED Indicator

4 OPT2 Status of optical interface 2 LED Indicator

5 VSWR VSWR error indicator LED Indicator

6 ACT RRU operating status indicator LED Indicator

7 REF Clock Reference Indicator LED Indicator

© ZTE Corporation. All rights reserved


25
Agenda

Overview

ZTE SDR Product Introduction

3 ZTE LTE Proposal for VNPT


Success Cases
Requirements and Configuration
eNodeB requirements:
-Licensed frequency band: UL 1710 - 1730 MHz and DL1805 -1825 MHz

-Main Package: Supply of 283 macro sites and 20 small cell sites.

Items Site Type Qty. Requirement

License: Power RTU: 30W/carrier; 4*4MIMO;


S111 L1800MHz 4T4R,
39 RRC_Connected_User: 450 per site;
15MHZ
Throughput: 450Mbps DL/150Mbps UL per site;
License: Power RTU 40W/carrier; 4*4MIMO;
S111 L1800MHz 4T4R,
169 RRC_Connected_User: 450 per site;
4G sites (Macro Distributed) 20MHZ
Throughput: 450Mbps DL/150Mbps UL per site;
License: MIMO 2x2, 2*2MIMO; Power RTU
S111 L1800MHz 2T2R, 40W/carrier; RRC_Connected_User: 450 per
75
20MHZ site;
Throughput: 450Mbps DL/150Mbps UL per site;
15MHz bandwidth for LTE 1800MHz
License: 4G: MIMO 2x2, Power RTU 5W/carrier;
Small cell 4G Micro Smallcell 20
RRC_Connected_User: 450 per site;
Throughput: 150Mbps DL/50Mbps UL per site.

© ZTE Corporation. All rights reserved


27
Requirements and Configuration
BBU requirements Small Cell Requirements
-BBU hardware is ready to support MIMO 4x4 and 3 cells -TX power: 2*5W/MIMO 2x2. IBW: 20 MHz
4T4R/20MHz and MIMO 2x2 and 3 cells 2T2R/20MHz. -4G LTE: supports 5/10/15/20Mhz channel bandwidth;
-BBU hardware is ready to support up to 2500 UEs in the -RRC_Connected_User 450; Throughput: DL 150/UL 50 Mbps.
RRC connected mode and 450 VoLTE users.
-BBU hardware is ready to support up at least 900Mbps Fiber Requirements
DL/450Mbps UL. Rodent-resistant optical cable Sites Qty.
-Power distribution module for all components in Base 50m 178
band Unit must be operated in N+1 redundancy mode. 100m 100
130m 5

RRU Requirements Configuration


-RRU Band 1800MHz: 4T4R/4*40W & 2T2R/2*60W
Site Type Qty. configuration
type with the IBW of at least 40 MHz, support at least
one 4G LTE cell carrier of 20MHz. L1800 S111 4T4R 20M 169 BPN2+CC16B+2*PM3+SA3+3*R8854
-Supplied ENODEBs must use separated RRUs (one RRU L1800 S111 4T4R 15M 39 BPN2+CC16B+2*PM3+SA3+3*R8854
per sector). RRUs installed in the same chassis are not
L1800 S111 2T2R 20M 75 BPN2+CC16B+2*PM3+SA3+3*R8862A
allowed.
-The RRU offered shall support RET AISG 2.0. Micro BTS 20 BS8922

© ZTE Corporation. All rights reserved


28
RAN Solution

© ZTE Corporation. All rights reserved


29
System Architecture
LTE Network Architecture BS8700 Product Architecture

Antenna

RRU

BBU
Abis/Iub/ CPRI
S1/X2

© ZTE Corporation. All rights reserved


30
VNPT LTE eNodeB Solution Highlights
Multi-mode BBU, cost saving, easy expansion Smallest and high performance RRU
R8862A:2T4R, small size
R8854:4T4R, the world smallest 4T4R RRU

GU GL  NB-IoT ready
TDD The NB-IoT hardware is ready, only software upgrade
L

 Engerineering Resources for the project are ready


Long term cooperation
Rich experience

2U UniRAN and TCO saving


ZTE 3G network alreay existed in 7 Central provinces. Based on
Large capacity multi-mode the solution provided for this tender, UniRAN and further TCO
Baseband processing board BPN2. saving can be realized easily.

© ZTE Corporation. All rights reserved


31
ZTE Proposed BBU Capacity
B8200-GUL Multi-Mode BBU
Highlight:
2U PM3 BPN2  ZTE GUL Multi-Mode BBU
PM3  Multi-mode GUL BPN2 baseband.
SA3 CC16B  Industry Leading MicroTCA Platform
 All-IP Switch Architecture Design

Type Site CC16B Qty. BPN2 Qty. Throughput RRC_Connecte


d User
Typical 6cells 600Mbps UL
1 1 7200
Performance 4T4R 900Mbps DL

BPN2:support G/U/L/GL/UL/GUL multi-mode.


1*BPN2 for LTE single mode:12*2T4R cell

© ZTE Corporation. All rights reserved


32
ZTE Proposed RRU Capacity
R8862A-Best Choice for LOW TCO 2T4R RRU R8854- 4T4R RRU ,4*4 MIMO Ready

4T RRU TM9 UE

12L/15Kg 12L/17Kg

 Small size, easy installation  World smallest 4T4R RRU


 Enhanced uplink sensitivity  L/GL: 4*40W
 GL/L: 2*60W  More powerful & more flexible
 Cell Range : >20%  Faster deployment
 Cell Coverage Area : >40%  Natural cooling and high
 UL Average THP : >50% reliability
© ZTE Corporation. All rights reserved
33
Site Type 1 Solution-4T4R L1800M 15MHZ-39 Sites

3*R8854

PM3 BPN2
Item Qty. unit
PM3
SA3 CC16B LTE FDD 15M License 3 Cell
LTE Power License (20W) 15 Kit

LTE FDD UL Throughput License 150 Mbps

LTE FDD DL Throughput License 450 Mbps

LTE FDD RRC_Connected User License 450 Sub

© ZTE Corporation. All rights reserved


34
Site Type 2 Solution-4T4R L1800M 20MHZ-169 Sites

3*R8854

PM3 BPN2
Item Qty. unit
PM3
SA3 CC16B LTE FDD 20M License 3 Cell
LTE Power License (20W) 21 Kit

LTE FDD UL Throughput License 150 Mbps

LTE FDD DL Throughput License 450 Mbps

LTE FDD RRC_Connected User License 450 Sub

© ZTE Corporation. All rights reserved


35
Site Type 3 Solution-2T2R L1800M 20MHZ-75 Sites

3*R8862A

PM3 BPN2 Item Qty. unit


PM3
SA3 CC16B LTE FDD 20M License 3 Cell
LTE Power License (20W) 9 Kit

LTE FDD UL Throughput License 150 Mbps

LTE FDD DL Throughput License 450 Mbps

LTE FDD RRC_Connected User License 450 Sub

© ZTE Corporation. All rights reserved


36
Site Type 4 Solution-Small cell L1800M-20 sites

Item Description Quantity

Small Cell BS8922 20

Item Quantity unit


BS8922 LTE FDD 15M License 1 Cell
LTE FDD UL Throughput 50 Mbps
S-GW MME License
LTE FDD DL Throughput 150 Mbps
License
BS8922
LTE FDD RRC_Connected 450 Sub
User License

© ZTE Corporation. All rights reserved


37
RRU Power and Optical Cable Solution

© ZTE Corporation. All rights reserved


38
RRU Power Cable& Optical Cable
RRU Power Cable Capablity

4mm2 6mm2 10mm2


R8862A 50 80 140
R8854 45 70 125

The detail should be follow site survey.


10mm2 power cable need ODCPD1.

RRU Optical Cable


RRU fiber use Rodent-resistant optical cable.
it delivery 50m, 100, 150m fiber.

© ZTE Corporation. All rights reserved


39
Antenna Solution for eNodeB

© ZTE Corporation. All rights reserved


40
4T4R RRU-Antenna Solution

1800-2600MHz 1800-2600MHz 1800-2600MHz


Antenna, AISG,
Antenna Antenna Antenna feeder form ACE.

+45° -45° +45° -45° +45° -45°

Two ports reserved ½ jumpers


RCU RCU RCU
for 2600MHz DM-DM

½ jumpers AISG cable AISG cable ½ jumpers AISG cable


DM-DM DM-DM

TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX

Sector 1 Sector 2 3 Sector 3 3


3
R8854 R8854 R8854

OMC

BPN2

© ZTE Corporation. All rights reserved


41
2T2R RRU-Antenna Solution

1800-2600MHz 1800-2600MHz 1800-2600MHz

Antenna Antenna Antenna Antenna, AISG,


feeder form ACE.

+45° -45° +45° -45° +45° -45°

Two ports reserved ½ jumpers


RCU for 2600MHz RCU RCU
DM-DM

½ jumpers AISG cable AISG cable ½ jumpers AISG cable


DM-DM DM-DM

TX/RX RX RX TX/RX TX/RX RX RX TX/RX TX/RX RX RX TX/RX

Sector 1 Sector 2 Sector 3


R8862A R8862A R8862A

OMC

BPN2

© ZTE Corporation. All rights reserved


42
RRU AISG Cable Solution

© ZTE Corporation. All rights reserved


43
RRU-Antenna AISG Solution
ZTE proposes DB15-8pin (female) AISG tie line include DB15 male connector (RRU side)
AISG 8-Pin female connector connecting to antenna in this tender.

A port PIN PIN9 PIN13 PIN14 PIN15

Port Definition AISG_485 A AISG_485B AISG_GND AISG_PWR

B port PIN PIN5 PIN3 PIN7 PIN6

© ZTE Corporation. All rights reserved


44
Agenda

Overview

ZTE SDR Product Introduction

ZTE LTE Proposal for VNPT

4 Success Cases
190 Operators, Over 1 Billion Subscribers in the World

110+ Countries

190+ Operators

90+ Swapped Network

400,000+ Swapped BTS

50+ Refarming Network

110+ HSPA+ Network

280+ LTE/EPC Commercial Contracts, The First LTE Provider in China

© ZTE Corporation. All rights reserved


46
ZTE 4G LTE Global Footprints- Guarantee Your Best Network
Belgium 3,500 eNB 210,000 eNB China
800M | 1.8G | 2.6G | CA 1.8G overlay +TDD| CA

India 3,200 eNB 140,000 eNB China


1.8G GL dual-mode 1.8G overlay | TDD | cloud radio
|CA
Indonesia 2,000 eNB
420,000 Enb China
1.8G GL dual-mode
TDD 2.5G |CA

Hungary 2,257 eNB 3,676 eNB Malaysia


1.8G GL dual-mode 1.8GL dual-mode |2.6G |CA

Austria 5,800 eNB Indonesia 3,151 eNB


1.8G GL dual-mode 850M | CA
South Africa 520 eNB
4,100 eNB Japan
1.8G GL dual-mode
TDD Macro + FDD Micro Hetnet

Thailand 5,500 eNB 6,500 eNB India


900M | 1.8G | 2.1G | CA 1.8G | CA

280+ LTE/EPC Commercial Contracts, The First LTE Provider in China

© ZTE Corporation. All rights reserved


47
Best Performance FDD Networks Around the Globe

H3G Austria, ranked No. 1 by Telkomsel Indonesia, awarded MTN South Africa, 2016 recognized
U MOBILE Malaysia, recognized as
Connect, OpenSignal in Dec. 2015 Best Network Technology in 2015 as Best Network in Cape Town;
MALAYSIA’S FASTEST MOBILE
and by CHIP in Jan. 2016; Aug. 2016, and 2016; Jan. 2016, ranked No.1 ranked No.1 in both P3 and
NETWORK in SPEEDTEST by
H3A was named Service Champion by OpenSignal in Makassar 3G MyBroadband test
OOKLA
in telecom Industry by ServiceValue and 4G speed test
GmbH
Consulting Organization China Telecom, in 2016, ZTE Ranked
Dec. 2016, top class consulting firm No. 1 in national overall network
Current Analysis graded ZTE eNodeB performance
Product as “Very Strong” China Unicom, in 2016, ZTE Ranked
No. 1 in in 3rd-party tests in tier-1
Aug. 2016, ZTE named as a “Leader” cities
in Gartner’s Magic Quadrant for LTE China Mobile, in 2016, ZTE named
solution Best 4G network national-wide

AMX Branches – VIP Macedonia and Mobilink Pakistan, ranked No. 1 out Airtel India, awarded ZTE Best Movistar Panama, ranked No. 1 4G
Velcom Belarus, ranked No.1 in of 4 operators by IOBM (Inter Network Support; ranked No.1 in network in Panama in 2015 and
local 3rd-party test Operator Benchmark) in 2016 3rd-party test 2016 in 3rd party tests

© ZTE Corporation. All rights reserved


48
ZTE, Always be the Innovation Pioneer & Leading Partner in
Wireless
First vendor proposed the Pre5G concept.
First vendor provided the SDR based solution, which already
Pre-commercial field testing of the world’s first pre5G Massive
has 1.75 million shipment
MIMO base stations.
90+ networks modernization experience Pre5G Massive MIMO was rewarded with the highest honor by
 110+ HSPA+ network globally GSMA in Feb.2016

Steady Growth Pioneer


2G/3G 4G Pre -5G 5G

Fastest Grows Most Energetic Player

280+ LTE/EPC Commercial Contracts Actively Promote 5G Standardization, ITU, 3GPP, IEEE, NGMN,
 The leading vendor in China LTE market IMT-2020
Strategic Cooperation with DT, softbank, china mobile, KT
Owns 815 LTE essential patents which take 13.0% of total
and etc.
241% CAGR of LTE shipment from 2012 to 2015
5G Prototypes on 2016 MWC: MUSA&FB-OFDM,HF Radio,
Network Slicing

© ZTE Corporation. All rights reserved


49
Product Success Cases
R8862A Large-Scale Deployment, Reliable Platform
Low TCO Solution RRU
Reliable 2T RRH platform Largest-scale

deployment in Global RAN market

600,000+ 2T4R R8862A are

applied in the world.

R8854 Commercial Deployment Case

30,000 R8854 for 3 years

© ZTE Corporation. All rights reserved


50
Thank you!

You might also like