You are on page 1of 6

Weatherproof type pressure switch

Model: P945 series


Spec. sheet no. PD09-05

Service intended
P945 diaphragm type pressure switch can be used in a
variety of process lines. Internal micro switch is operated
by pressure of various fluids such as atmospheric
pressure and water pressure. The pressure sensing part
is a piston actuated assembly.

Fluid
Gas and oil

Repeatability
±1.0 % of adjustable range

Adjustable range (mbar, kPa, bar, MPa)


-0.1 to -0.15 bar
0.3 kPa to 15 MPa

Dead band
Fixed
One SPDT : Approx. 5 % of adjustable range
Two SPDT : Approx. 10 % of adjustable range

Working temperature
Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C

Degree of protection
EN60529/IEC529/IP65

Standard features
Pressure connection Contact rating
Stainless steel (316SS), Monel and Hastelloy-C SPDT contact rating
AC 125 V / 250 V, 15 A
DC 125 V, 0.4 A for resistance load
DC 125V, 0.03 A for inductive load
Element
Stainless steel (316L SS)

Conduit connection
¾" NPT (F)
Case and cover
ALDC 12.1 (Silver gray painted)

Process connection
⅜", ½" PT, NPT and PF
Contact
Micro contact type
One SPDT
Two SPDT (Only available with single setpoint)

P945_01
Main order Ordering information
1. Base model
P945 Weatherproof type pressure switch

2. Deadband
F Fixed

3. Switch form
1 One SPDT
2 Two SPDT (Only available with single setpoint)

4. Process connection
C ¼"
D ⅜"
E ½"

5. Connection type
B PF
C PT
D NPT
E NPT (F)

6. Unit
H bar
I MPa
J kPa
S mbar

7. Setting range
XXX Refer to pressure range table

8. Process connection and element material


3 316SS / 316L SS
V 316SS / Viton
L 316SS / Hastelloy-C
K 316SS / Monel
Z Monel / Monel
H Hastelloy-C / Hastelloy-C

9. Options
0 None
1 Mounting bracket
4 ½" NPT (F) conduit connection

1 2 3 4 5 6 7 8 9
Sample
P945 F 1 C B H XXX 3 0 ordering code

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT
NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

P945_02
P945 : Type of mounting

P945_03
Pressure switch Working range
A bi-stable electro mechanical device than actuates/ The maximum input pressure that can be continuously
deactuates one or more electrical switching element at a applied to the pressure switch without causing
predetermined discrete pressure upon rising or falling. permanent change of set point, leakage or material
failure.

Adjustable range Max. Working pressure


The span of pressure between upper and lower limits The maximum input pressure that can be continuously
within which the pressure switch can be adjusted to applied to the pressure switch without causing leakage
actuate/deactuate. It is expressed for increasing or catastrophic material failure. Permanent change of
pressure. set point may occur, or the device may be rendered
inoperative.
Setpoint
That discrete pressure at which the pressure switch is
Repeatability
adjusted to actuate/deactuate on rising or falling The ability of a pressure switch to successively operate
pressure. It must fall with the adjustable range and be at a set point that is approached from a starting point
called out as increasing. in the same direction and returns to the starting point
over three consecutive cycles to establish a pressure
profile.
Dead band The closeness of the measures set point values is
The difference in pressure between the increasing set normally expressed as a percentage of full scale
point and the decreasing set point. (maximum adjustable range pressure).

Pressure range table

Dead band
Flange
Working
Code Adjustable setting range One SPDT Two SPDT size Max. Working pressure
range
Setpoint Setpoint (mm)

bar kPa bar bar bar bar MPa


Within 10 % Within 20 %
900 -0.1 ~ -0.15 -100 ~ -15 adjustable adjustable
range range
901 0.075 ~ 0.15 7.5 ~ 15 10 88 ~ 98
938 0.045 ~ 0.3 4.5 ~ 30
941 0.075 ~ 0.5 7.5 ~ 50 35 3.5
949 0.09 ~ 0.6 9 ~ 60
942 0.12 ~ 0.8 12 ~ 80
20 63
902 0.15 ~ 1 15 ~ 100
903 0.3 ~ 2 30 ~ 200 Within 5 % Within 10 %
adjustable adjustable
904 0.45 ~ 3 45 ~ 300 range range
906 0.9 ~ 6 90 ~ 600
908 1.5 ~ 10 0.15 ~ 1 MPa 70 7
50
911 2.25 ~ 15 0.225 ~ 1.5 MPa
912 3 ~ 20 0.3 ~ 2 MPa 60
914 4.5 ~ 30 0.45 ~ 3 MPa
170 17
916 7.5 ~ 50 0.75 ~ 5 MPa
100
918 8.5 ~ 70 0.85 ~ 7 MPa
200 20
919 10.5 ~ 100 1.05 ~ 10 MPa
150
926 15.5 ~ 150 1.55 ~ 15 MPa 400 40

P945_04
Micro contact
General
The micro contact has a large switching capacity with high repeat accuracy. The contact mechanism is a crossbar
type with gold alloy contacts, which ensures highly reliable operations for micro loads.

Characteristics
Item Micro switch
Operating speed 0.01 mm to 1 m/s
Mechanical operating frequency 240 operations/min
Insulation resistance 100 MΩ 1 min at 500 VDC
Contact resistance 0.015 Ω max
Shock resistance 100 m/sec² max
Ambient temperature -25 ~ 80 ºC
Ambient humidity 35 ~ 85 % RH

Specifications
Non inductive load (A) Inductive load (A)
Rated voltage Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 V AC 15 3 1.5 15 5 2.5
250 V AC 15 2.5 1.25 15 3 1.5
8 V DC 15 3 1.5 15 5 2.5
30 V DC 2 2 1.4 1 1 1
125 V DC 0.4 0.4 0.4 0.03 0.03 0.03
250 V DC 0.2 0.2 0.2 0.02 0.02 0.02
SPDT switching element
Single-pole, double throw (SPDT) has three connection : C-common, NO-normally open and NC-normally close,
which allows the switching element to be electrically to the circuit NO or NC state.

One SPDT
Pressure reach the upper or lower limit setpoint, circuit closed and opened.

Two SPDT
Pressure reach the upper or lower limit setpoint, two circuit simultaneous closed and opened.

P945_05
Memo

P945_06

You might also like