Coagulation Input Cell

Calculation Cell

Given:
Design Flow 0.709 m3/s
Average flow 0.47 m3/s

Design Criteria
Mixing Time sec

G, velocity gradient 1/sec

Tank Shape Circular


Minimum number of tanks 2
Max Size of tank 8 m3
Depth/Diameter
Impeller Dia/Tank Dia 0.2-0.4 Check Range

Motor and Mixer


Rotaional Speed of Mixer rpm
Available power kw
Impeller Type Turbine
No. of Blades, Vaned
KT of Impeller
Water Density 1000 kg/m3
Viscosity 1.05E-03 kg/(m.sec)
Power Transmission Effeciency 90 %

Alternative
Impeller Dia/Tank Dia
Calculations:
Volume of all units 0.00 m3
Number of Tanks 2.00 m3
Volume of each tank 0.00 m3
Diameter of each tank #DIV/0! m
Depth #DIV/0! m

Round Dimensions:

Diameter of each tank #DIV/0! m


Depth #DIV/0! m
Water Volume #DIV/0! m3

Alternative 1 (Find Di knowing n)


Pw = Power imparted on water #DIV/0! kw
PM = Min power of mixer motor #DIV/0! kw
Power of available Mixer Motor #DIV/0! kw Assumed From manufacturer
Pw (actual) #DIV/0! kw
Required Impeller Diameter #DIV/0! m
Check (D-imp/D-tank) #DIV/0! within 0.2-0.4 - Design Check

Alternative 2 (Find n Knowing Di)


Pw = Power imparted on water #DIV/0! kw
PM = Min power of mixer motor #DIV/0! kw
Power of available Mixer Motor #DIV/0! kw
Pw (actual) #DIV/0! kw
Required Impeller Diameter #DIV/0! m
Required Rotational Speed #DIV/0! rpm Check Availability
#DIV/0! #DIV/0!

###

#DIV/0!
Flocculation Input Cell
Calculation Cell
Given:
Design Flow 0.71 m3/s
Average flow 0.47 m3/s

Design Criteria
Mixing Time min
Number of stages/tank (tapered flcocculation) 3
G1, velocity gradient 1/sec
G2, velocity gradient 1/sec
G3, velocity gradient 1/sec
G -Avge #DIV/0! 1/sec
Tank Shape Rectang
Minimum number of tanks 2
Sedimentation Tank width #DIV/0! m
Depth/Length of Each Compartment 1

Blades/Mixer/Paddles
Gap between blades and walls or water Surface 0.4 m
Gap between wheels 0.3 m
No. Wheels per stage 3
Max Paddle area/surfrace area 20 %
Max outer Paddle tip speed 2
Velocity of paddle/velocity of water = K 0.75
Max Length of each blade 3.00 m
Width of each blade 0.15 m
Number of blades per wheel
Spacing between blades in wheel 0.3 m

Power Requirements
Available power kw
Water Density 1000 kg/m3
Viscosity 1.05E-03 kg/(m.sec)
Power Transmission Effeciency 90 %
Find Drag Coeffecient (CD)

LP/WP CD
5 1.2
20 1.5
α 1.9
Calculations:
Volume of all units 0 m3
Number of Tanks 2 m3
Volume of each tank 0 m3
Volume of each stage 0 m3
Width of compartment #DIV/0! m
Legth of compartment #DIV/0! m
Depth of compartment #DIV/0! m
Surface Area of each copmartnment #DIV/0! m2

Proportion Paddles
No. Wheels per stage Err:522
Number of wheels*length of each blade #DIV/0! m
Length of each blade #DIV/0! m If>3, increase No. wheels
Blade Length/Width #DIV/0!
Blades area per compartment Err:522 m2
Blades Area/Surface Area Err:522 Less than 20% - Design Check
Outer diameter of rotation of outer plade tip #DIV/0! m
Diameter of 2nd inner blades #DIV/0! m
Diameter of 1st inner blades #DIV/0! m

Max Power Requirements - 1st Stage


Power required (average G) per stage 0.00 kw
Min power of mixer motor per stage 0.00 kw
Power of available Mixer Motor 0.00 kw
Power to be Imparted to Water 0.00 kw
Required Rotational Speed #DIV/0! rpm
Check tip velocity #DIV/0! m/s < 1m/s - Design Check
This is the fastest so the other OK
Power Requirements Compartment 1
Motor Power required 0.00 kw

Power Requirements Compartment 2


Motor Power required 0.00 kw

Power Requirements Compartment 3


Power required 0.00 kw
#DIV/0!

#DIV/0!
ease No. wheels

0% - Design Check

0.15

#DIV/0!

- Design Check
est so the other OK
Sedimentation Input Cell
Calculation Cell
Given:
Max Design Flow 0.709 m3/s
Average flow 0.473 m3/s

Design Criteria
Overflow rate m3/m2/d
Weir Loading m3/m/d
Tank shape Rectang
Length/Width
Depth m
Number of Units 2 Units
Horizontal velocity 0.15- 0.90 m/min
Calculations:
Surface area of all tanks #DIV/0! m3
Number of tanks 2 #
Surface area of each tank #DIV/0! m4
Width of each #DIV/0! m
Length of each #DIV/0! m
Volume of each #DIV/0! m3
Detention time in each #DIV/0! hrs > 2 hrs - Design Check
Horizomtal Velocity #DIV/0! m/min < 0.9 m/min - Design Check
Weir length in each tank #DIV/0! m
Number of Horizontal Weir Edges #DIV/0! m
#DIV/0!

#DIV/0!

0
Filtration Input Cell
Given: Calculation Cell
Max Design Flow 0.709 m3/s
Average flow 0.473 m3/s

Design Criteria
Filtration Rate m3/m2/d
Backwash Rate m3/m2/d
Filter Type Multi-Media
Tank shape Rectang
Length/Width 2 1:1 to 2:1
No. Sedimentation tanks 2
Maximum surface area of each filter 50 m2
Minimum number of units 2 filters
Underdrains Depth 1 m
Water depth above media 1 m
Freebaord 0.4
Backwash water storage tank Use final storage tank
Backwash water holding/settling tank depth 3.5 m

Operation & Maintenance


Number of Tanks to be Backwashed Simultaneoulsy 2 Filters
Number of times a filter is backwashed every day 1 times
Backwash Duration min
Backwash Water/Filtered Water 2-5 %

Filter Properties
Effective Size
Media Type Depth (cm) (mm)
Anthracite Coal Layer Depth 48 1.4
Sand Layer Depth 30 0.5
Garnet Layer Depth 10 0.35
Gravel Layer Depth 50 ------
alculation Cell Filters Dimensions
Surface area of all filters #DIV/0!
(A) No. of Filters based on Sed. Tanks 4
(B) No. of 50 m2 Filters #DIV/0!
Number of Filters #DIV/0!
Area of Each filter #DIV/0!
Width of each #DIV/0!
Length of each #DIV/0!
Media Depth 1.38
Total Water Depth (medai + drains + water above media) 3.78

Backwash Storage
Daily backwash water volume per filter #DIV/0!
Daily backwash water volume for filters washed at the same time #DIV/0!
Daily water treated by one filter #DIV/0!
% Treated water used for backwashing one filter #DIV/0!

Backwash Holding/Settling Tank


Daily backwash water generated #DIV/0!
back wash water generated at a time #DIV/0!
Volume of backwash water settling tank #DIV/0!
Area of tank #DIV/0!
Diameter of Tank #DIV/0!

Uniformity
Coefficient Specific Gravity
<1.5 1.4-1.75
<1.5 2.55-2.65
<1.5 3.8-4.3
------ ------
m2

m2
m
m
m
m

m3
m3
m3
% 2-5% - Design Check

m3/d
m3
m2
m2
m
Disinfection Input Cell
Calculation Cell
Given:
Max Design Flow 0.709 m3/s
Average flow 0.472667 m3/s

Design Criteria

Detention time 20 min

Length/Width 40

Depth/Width 1

Number of Units 2

Chlorine Dose 2.7 mg/L


Calculations:
Volume of all units 851 m3
Volume of each unit 425 m3
Width 2.20 m 17.6
Depth 2.20 m

Length 87.96 m

Chlorine Requirements 165.40 kg/d 11.0