DSEULTRA
®
STARTING
WITH SPECIFICATION
QUALITY. DC SUPPLY
8V to 35V continuous
CRANKING DROPOUTS
Able to survive 0V for 50mS, providing supply
DSE705 & DSE4130 was at least 10V before dropout and supply
recovers to 5V. This is achieved without the
AUTO TRANSFER SWITCH CONTROL MODULES need for internal batteries.
TYPICAL CURRENT
15mA(12V and 24V)
AUXILIARY OUTPUTS
1.2 Amp DC at supply voltage. Switches to
battery negative when active
DSE705 DIMENSIONS
165mm x 125mm x 29mm
6.5” x 4.9” x 1.2”
DSE4130 DIMENSIONS
171mm x 115mm x 49mm
6.75’’ x 4.5’’ x 2’’
ENVIRONMENTAL TESTING
STANDARDS
BS EN 61000-6-2
The DSE705 and DSE4130 are Auto FEATURES OPERATION EMC Generic Immunity Standard for the
Transfer Switch Control Modules • Automatic mains (utility) supply The modules are operated using the Industrial Environment
that have been designed to monitor monitoring three push buttons on the front: ELECTRICAL SAFETY
the mains (utility) supply. • Load changeover control BS EN 60950
• Manual start MANUAL OFF LOAD - Safety of Information Technology Equipment
• Protected Solid State (PSS) including Electrical Business Equipment
When the mains (utility) power fails This is used to manually
the modules send a start request outputs start and run the engine off TEMPERATURE
• Front panel mounting load. Should the mains BS EN 60068-2-2
to the generator control unit. o
Test Ab to 70 C
• Front panel programming (utility) supply fail, then the o
Test Ab to -30 C
• LED indicators load is transferred to the
When the generator is up and • Configurable timers generator automatically. VIBRATION
running the modules transfer • Configurable outputs BS EN 60068-2-6
the load across. When the • Single/three phase mains sensing MANUAL ON LOAD - Ten sweeps in each of the three major axes
mains (utility) returns the 5Hz to 8Hz @ +/- 7.5mm
• Remote start input This mode is used to
modules transfer the load back manually start and run the HUMIDITY
and remove the start command. BENEFITS engine on load. BS EN 60068-2-30
o
The generator should then begin • Transfers between mains and Test Db 95% RH @ 55 C for 12 hours
its shutdown procedure. generator power AUTO MODE - This puts the SHOCK
• On-site module configuration to module into automatic BS EN 60068-2-27
Both modules can be configured match user requirements mode, where it will await a Three shocks in each of three major axes
15gn in 11mS
so that they follow the users mains (utility) failure. Upon
pre-set start and stop sequences. detection it will send a start
The DSE4130 enclosure has a request to the generator
closed back. control unit.
DEEP SEA ELECTRONICS PLC TELEPHONE EMAIL ®
Highfield House +44 (0)1723 890099 sales@deepseaplc.com
Hunmanby Industrial Estate
Hunmanby, North Yorkshire FACSIMILE WEBSITE
YO14 0PH England +44 (0)1723 893303 www.deepseaplc.com
LOAD
L1 L1
L2 L2
FROM L3 L3
FROM
GENERATOR MAINS
N N
2 AMP 2 AMP
FUSES ELECTRICAL INTERLOCK FUSES
G M
NORMALLY OPEN NORMALLY CLOSED
+ * * +
20 21 14 13 16 17 18 19
L1 N L1 L2 L3 N
CLOSE GEN
CLOSE MAINS
NEUTRAL POSITION
REMOTE START
OUTPUT 1
OUTPUT 2
CLOSE TO
1 2 3 4 5 11 12 15
* *
+ +
2 AMP
FUSE
NOTE 1
THE REMOTE START INPUTS OF ALL DSE CONTROLLERS
CAN BE CONNECTED DIRECTLY TO THE START / RUN
OUTPUT (TERMINAL 3) OF THE 4130 ATS CONTROLLER,
PROVIDING THAT THE DC SUPPLIES ARE COMMON TO
EACH MODULE.
* NOTE. ALL THE OUTPUTS ARE SOLID STATE AND ARE NEGATIVE SWITCHING
Please refer to the installation instructions for the parameter settings and full
configuration information.
DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right to
change the details shown on this data sheet without prior notice. The contents are intended for guidance only.
This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre
from both pre and post-consumer sources, together with 45% virgin ECF fibre.
055-043/05/07 (1)