UT$%2SHUDWLQJ0DQXDO

Ɣ Replace the battery as soon as the battery 2. HOLD


indicator appears. With a low battery, the Meter 3ress HOLD to enter and H[Lt hold mode H[FHSt
UT118A/B 3HQ Type Meters might produce false readings that can lead to electric
VKRFNDQGSHUVRQDOLQMXUy.
XQGHUDXWRVFDQPRGH 
3ress and hold the HOLD button more than 
Ɣ W h e n s e r v i c i n g t h e M e t e r, u s e o n l y t h e seconds, the meter automatically holds the value
Operating Manual same model or identical electrical specifications
replacement parts.
which obtains at 6 seconds later, at this time, is
GLVSOD\HGDQGÀLFNHULQJ
Ɣ The internal circuit of the Meter shall not be ,I enter ³VOHHS´ mode under hold mode, the meter still
Overview altered at will to avoid damage of the Meter and any in the hold mode when it be turned on.
This Operating Manual covers information on safety accident. 3. MAX/MIN
and cautions. 3OHDVH read the relevant information Ɣ 6oft cloth and mild detergent should be used to The MAX0,1 mode stores minimum (M,1 and
carefully and observe all the Warnings and Notes clean the surface of the Meter when servicing. No PD[LPXP (MAX input values H[cept under auto scan
strictly. abrasive and solvent should be used to prevent the mode . Manual ranging comes when you select this
surface of the Meter from corrosion, damage and function.
Warning accident. 3UHVVMAX/MIN button MAX 0,1 0$;0,1
To avoid electric shock or personal LQMXUy, read the Ɣ Do not use or store the Meter in an environment and vice versa.
6afety ,QIRUPDWLRQ" and "Rules for 6afe Operation" of high temperature, humidity, H[SORVLYH LQÀDPPDEOH Under hold mode and PD[PLQ mode, should H[LW hold
carefully before using the Meter. and strong magnetic field. The performance of the mode ¿UVW then press and hold 0$;0,1 more than 
Meter may deteriorate after dampened. VHFRQGWRH[LWPD[PLQPRGH
The Model UTA and UTB (hereafter referred
4.
to as ³the MetHU´ are  counts pen type digits International Electrical Symbols Display Backlight and test lead light button, 3ress
millimeters. The Meter uses large scale of integrated
DH¿FLHQF\RI%XLOW,Q%DWWHU\ once to turn the display backlight and test lead light
circuit with professional multimeter ,& as its core and
on and press again to turn the display backlight and
has full range overload protection.
Grounding test lead light off. ,W will automatically off after around
The Meter measures or tests the following:
$& $OWHUQDWLYH&XUUHQW PLQXWH
Ɣ AC/DC voltage
5. AUTO POWER OFF
Ɣ())XQFWLRQ 87%RQO\ '& 'LUHFW&XUUHQW
To preserve battery life, the Meter automatically goes
Ɣ5HVLVWDQFH 'RXEOH,QVXODWHG into a ³VOHHS´ mode if you do not press any button for
Ɣ'LRGH
Continuity Test around  minutes. The Meter can be activated by
Ɣ&RQWLQXLW\
pressing any button, then returns to the display for the
Ɣ&DSDFLWDQFH AC or DC
function selected previously
Diode 6. BUZZER
Unpacking Inspection &RQIRUPVWR6WDQGDUGVRI(XURSHDQ The buzzer phonate go with every time button be
Open the package case and take out the Meter.
Warning. Refer to the Operating Manual effectual pressed. When the meter will auto power off
Check the following items carefully to see any
in  seconds the buzzer beeps three times. Before
missing or damaged part:
power off there will be a long time buzzer beeps.
Item Description Qty The Meter Structure VHH¿JXUH
(QJOLVK2SHUDWLQJ0DQXDO SLHFH
 THVW/HDG SDLU Measurement Operation
,Q the event you ¿QG any missing or damage, please Before measurement, anticlockwise circumgyrate the
red cover and rock the input terminal.
contact your dealer immediately. When all themeasurement has been completed,
)LJXUH deasil circumgyrate the red cover then hide the input
WHUPLQDO VHH¿JXUH
Safety Information )URQW+RXVLQJ)XQFWLRQDOEXWWRQV
This Meter complies with standards (1 in 6ZLWFK/&''LVSOD\
pollution degree  over voltage category (CA7,,, ,QSXW Terminals
9 DQGGRXEOHLQVXODWLRQ
CAT,,,: Distribution level, fi[ed installation, with Display Symbols VHH¿JXUH
smaller transient over voltages than CAT,V.
Use the Meter only as specified in this operating )LJXUH
manual, otherwise the protection provided by the 1. AC / DC Voltage auto Measurement.
Meter may be impaired.
Warning
,Q this manual, a Warning identifies conditions
To avoid harm to the Meter, never input higher than
and actions that pose hazards to the user, or may
V voltage although it is possible to measure
damage the Meter or the equipment under test.
higher voltage.
A Note LGHQWL¿HV the information that user should pay
To measure Voltage, connect the Meter as follows:
attention on. )LJXUH Ɣ6HWWKHVZLWFKWRV .
,QGLFDWHVDXWRVFDQPRGH Ɣ Auto measuremeng mode is a default. Under this
Rules For Safe Operation +LJKYROWDJHLQGLFDWRU mode can measure AC voltage and DC voltage.
'DWDKROGLVDFWLYH Ɣ&RQQHFWWKHWHVWOHDGVDFURVVZLWKWKHREMHFW
Warning ,QGLFDWHVQHJDWLYHUHDGLQJ being measured. The measured value shows on
To avoid possible electric shock or personal LQMXUy, 5. The meter is in the autorange mode the display.
and to avoid possible damage to the Meter or to the ,QGLFDWRUIRU AC voltage Ɣ:KHQYROWDJHPHDVXUHPHQWKDVEHHQFRPSOHWHG
equipment under test, adhere to the following rules: ,QGLFDWRUIRU'&YROWDJH disconnect the connection between the testing
Ɣ Before using the Meter inspect the case. Do not 8. The battery is low leads and the circuit under test, and remove the
use the Meter if it is damaged or the case (or part testing leads away from the input terminal of the
of the casH is removed. /RRk for cracks or missing Warning: To avoid false readings, which could
lead to possible electric shock or personal LQMXUy, meter.
plastic. 3ay attention to the insulation around the Note:
connectors. replace the battery as soon as the battery indicator
appears. The threshold voltage of $&YROWDJHLVDURXQGPV.
Ɣ ,QVSHFW the test leads for damaged insulation or
H[SRVHG metal. Check the test leads for continuity. 9. Minimum reading.
0D[LPXPUHDGLQJ 2. DC Voltage Measurement
Replace damaged test leads with identical model
number or electrical specifications before using the  The unit of Capacitance Warning
Meter.  Test of diode To avoid harm to the Meter, never input higher than
Ɣ When using the test leads, keep your fingers  The continuity buzzer is on. V voltage although it is possible to measure
EHKLQGWKH¿QJHUJXDUGV 9Volts. The unit of voltage. higher voltage.

Ɣ Do not apply more than the rated voltage, as P90LOOLYROW[RUYROWV Ɣ6HWWKHVZLWFKWRV .
marked on the Meter, between the terminals or ȍ2KP The unit of resistance Ɣ3UHVV6(/(&T to select DC voltage measurement

between any terminal and grounding. NȍNLORKP[RURKPV mode.
Ɣ When the Meter working at an effective voltage 0ȍ0HJDRKP[RURKPV Ɣ&RQQHFWWKHWHVWOHDGVDFURVVZLWKWKHREMHFW
over V DC or V AC, special care should be being measured. The measured value shows on
taken for there is danger of electric shock. Button function and auto power off the display.
Ɣ Use the proper function, and range for your 1.SELECT Ɣ:KHQYROWDJHPHDVXUHPHQWKDVEHHQFRPSOHWHG
measurements. 3UHVVSELECT to switch between resistance, AC/DC disconnect the connection between the testing
Ɣ Disconnect circuit power and discharge all high voltage, continuity buzzer and diode measurement leads and the circuit under test, and remove the
voltage capacitors before testing current, resistance, modes. 3UHss and hold more than  seconds in or testing leads away from the input terminal of the
diodes or continuity. H[LW³VOHHS´PRGH meter.
P/N:110401103466