Site: ......................................................................................................

Operator inspection checklist


Interval Number Time Inspection task Observation Reference values
of (Value / OK / NOT OK)
persons
Every 1 6 Check the leakage at the 10-20 cm³/min
shift min. mechanical seal or the leakage
rate at the gland packing.
Lower than -0.1 Bar
Inlet pressure: Manometer
Inlet pressure: Pressure Lower than -0.1 Bar
sensor
Minimum: 23.0Bar
Set Value : 3.2m
Maximum: 26.0Bar
Outlet Manometer
Minimum: 23.00 Bar
Maximum: 26.0 Bar
Outlet Pressure sensor
3300 V +/- 198V
Main incoming voltage
Between 0.8 and 1.0
Power factor
Maximum: 4.2m
Set Value : 3.2m
Minimum: 2.2
Reservoir level
1000-1800 m³/h
Flow meter outlet
Weekly 1 15 Lower than 90 ◦c
min. Bearing temperature
Lower than 90 ◦c
Motor temperature

Heavy noise or vibration

Running hours
10
Monthly 1 min Number of trips

Date: ...................................................................................................

Name:.................................................................................................

Signature:...........................................................................................