The following symbols are used for the safe operation of this device.
■General Precaution
・ When setting up this device, power at the junction box must be OFF.
・ Do not short-circuit wires or terminals.
・ Check the wiring to be sure it is correct before supplying power to the unit.
・ The device is an electronic device. Therefore, when installing various devices,
investigate the installation environment (primary electrical noise, driver type
noise, static electricity discharge noise, etc.). These noises may cause system
malfunction or damage.
・ Make sure that connected devices are within specification condition shown in
this device specifications. Also, even if it is within the specifications, it may not
be possible to use it with equipment with excessive inrush current.
・ The gate opens and closes with strong force. Inserting your hand when opening
or closing may cause unexpected injury.
Revision History
Date Printed Version File Name Details
2019 Sep.9 Ver.1.0 MWU2030FNSH_UM_V10_E First edition
2019 Dec 18 Ver.1.1 MWU2030FNSH_UM_V11_E Added [5. Special Menu]
Related Manuals
1. Overview ......................................................................................................................................................... 7
Product Appearance ..................................................................................................................................................7
Part Numbers ..............................................................................................................................................................8
Product Type ...............................................................................................................................................................9
Mounting Attachments ..............................................................................................................................................9
Standard Gate ...........................................................................................................................................................10
Names and Functions of Each Part....................................................................................................................... 11
2. Operation Procedure ................................................................................................................................... 13
Connection Configuration.......................................................................................................................................13
2.2 Address Settings ......................................................................................................................................................13
2.3 Connection Method to the Junction Box..............................................................................................................14
2.3.1 Installation Restrictions...........................................................................................................................................................15
2.4 Installation Method of the MWU2030FNSH ..........................................................................................................16
2.4.1 Installation Method of Light Module ......................................................................................................................................16
2.4.2 How to Install the Gate.............................................................................................................................................................17
2.4.3 Adjust the Open and Close Gate Angle ................................................................................................................................18
2.4.4 Adjust the Gate Shutting Delay Time ....................................................................................................................................18
2.5 Operation Check .......................................................................................................................................................19
3. Operation Methods ...................................................................................................................................... 22
Basic Operation of the MWU2030FNSH ...............................................................................................................22
3.1.1. Select the Operation.............................................................................................................................................................23
3.1.2. Minus Operation ...................................................................................................................................................................24
Opening / Closing Operation Errors......................................................................................................................25
Display Address Operation (A command)............................................................................................................27
Unlock the Gate (Release Mode)............................................................................................................................28
Notes on the Gate Operation ..................................................................................................................................29
Release Mode / Open and Close Errors................................................................................................................29
4. Control Command........................................................................................................................................ 30
Command List...........................................................................................................................................................30
Operation on the Existing System .........................................................................................................................30
Control Command ....................................................................................................................................................31
5. Special Menu ................................................................................................................................................ 36
How to Switch to the Special Menu .......................................................................................................................36
Special Menu【F1】Address Setting ....................................................................................................................37
Special Menu【F2】Delayed Shut-off Time Setting ...........................................................................................38
Special Menu【F3】Open / Close Angle Setting.................................................................................................39
5.4.1. Open/close Angle Setting of the Outward Opening Type ..............................................................................................39
5.4.2 Open/close Angle Setting of the Inward Opening Type ......................................................................................................40
Special Menu【F4】Open / Close Speed Setting................................................................................................41
Special Menu【F5】Angle Range Setting ............................................................................................................42
6. NFC Communication ................................................................................................................................... 43
7. External Dimensions.................................................................................................................................... 44
MWU2030FNSH-1** and MWU2030FNSH-04 Installation Dimensions ............................................................44
MWU2030FNSH-2**and MWU2030FNSH-04 Installation Dimensions .............................................................45
External Dimensions of Attachments ...................................................................................................................46
7.3.1. MWU2030FNSH-03 External Dimensions.........................................................................................................................46
7.3.2. MWU2030FNSH-04 External Dimensions.........................................................................................................................46
7.3.3. MWU2030FNSH-05 External Dimensions.........................................................................................................................46
7.3.4. MWUD2001 External Dimensions......................................................................................................................................46
8. Light Module Specifications........................................................................................................................ 47
Device Specification.................................................................................................................................................47
Gate Specification.....................................................................................................................................................48
List of Settings ..........................................................................................................................................................48
9. Troubleshooting ........................................................................................................................................... 49
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
1. Overview
The MWU Series with NFC-enabled Poka-yoke gate light module is a light module with a gate mechanism
added to the conventional MWU series light module.
In addition to the conventional light module functions, it can drastically reduce picking errors by installing a gate
that opens and closes.
The control method of the gate section varies depending on the product type. Select according to your
application specifications.
Check if the connected devices are within the specification conditions shown in
this manual. Also, even if it is within the specifications, you may not be able to
use with equipment with an excessive inrush current. Make sure to evaluate
before using this product.
Product Appearance
[MWU2030FNSH-101] Outward opening type
7
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Part Numbers
M 2 3 0 F N S - 1 01
W 0 H
U
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
*1 [full color] 7 colors: red, green, blue, yellow, purple, cyan, and white
*2 For a new system, you need to select new operation instructions.
When using this light module for an existing system, please contact us.
8
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Product Type
Part No. Specification Shape
MWU2030FNSH-101 Gate opening and closing direction: Outward
opening
Mounting Attachments
Attachments for the MWU2030FNSH. Select according to the shelf to be installed.
9
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Standard Gate
Standard gate
※The standard gate cannot be used for the AW2038FSH and MWU2038FSH.
10
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
[4] Arm
11
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
The tip is sharp. Be careful not to touch it as it may cause injury. If this pin is damaged,
contact failure of power supply and signal may occur, so do not apply force.
[4] Arm
Gate drive arm.
From the front view, the right arm is the drive unit, and the left arm is free.
Accessory parts
No Item Qty
③
① M4 Truss Screw Length 14mm Black 4 pcs
② M4 Flat Washer Outer Diameter 15mm 4 pcs
②
③ Hollow Spacer φ5.3 Length 4.5mm 4 pcs
The gate opens and closes with strong force. Inserting your hand when
opening or closing may cause injuries. Do not insert your hands while gate
is opening or closing.
12
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
2. Operation Procedure
This section describes the flow from initial settings to the connection method and operation check.
Connection Configuration
Control with PC
PC
TW2209
MWU2030FNSH-101
MWU2030FNSH-101
When using this device, it is necessary to set an address corresponding to the system.
We recommend that you set the address before installing.
Use the following method for address setting.
〇Set using address writer
MWU2706 User’s Manual
〇Set by sending “address setting command” via controller
MWU Series Command Reference Manual
〇Set using the light module’s address setting function.
5.2 Special Menu【F1】 Address Setting
〇Address setting with NFC
6 NFC Communication
13
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
AI connector
AI cable
TW2209
MWU2030FNSH-101
AI-J01NA
14
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
TW2209
TW2209
Max 20m
15
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Make sure that the junction box is turned off when connecting. Turn on the
junction box after confirming that wiring is correct and there is no short circuit
(between two wires and between FG).
• Hook the light module on the fulcrum at the top of the duct base and insert it in the direction of the arrow.
Fulcrum
• Installation is complete when the lock levers lock into the duct,
Lock lever
How to remove
Release the gate portion to make it movable.
Lift the gate and push upward while pressing the left and right lock levers
Fulcrum
m
Lock lever
16
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Accessory parts
No Item Qty
③ ③
① M4 Truss Screw Length 14mm Black 4 pcs
② M4 Flat Washer Outer Diameter 15mm 4 pcs
② ②
③ Hollow Spacer φ5.3 Length 4.5mm 4 pcs
①
Mounting image
17
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
* After installing the light module, be sure to set the fully open and fully close positions so that shelves and
items inside do not interfere with the gate.
If the power is turned on while the arm is at a position other than the open/close angle,
the gate may not operate. If it does not work, manually move the arm within the open and
close angle.
Adjustments can be made in the extended menu. Refer to section 5.3 Special Menu [F2] Adjustment of the
Gate Shutting Delay Time.
The time can be set every 0.1 second from 0 to 25.5 seconds.
The default setting is 2 seconds.
The gate shutting time is the delay time after pressing the CONFIRM button. If the light
module receives the next operation instruction within the delay time, the next operation
instruction will be lit with the gate open.
18
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
19
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
The MWU2030FNSH consumes a large amount of current to open and close the gate. If
you send an operation instruction at the same time, do not exceed 6 units. If you want to
communicate with all light modules as communication aging test, set the mode to not
open / close the gate, and then send an operation instruction.
instruction command or send a work instruction every six units.
When you press the CONFIRM button, the status becomes normal.
Make sure that the status of all light modules is normal after pressing the CONFIRM button.
If there is a malfunctioning device, check the address of this device.
20
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
When the A command is sent, all the light modules will display the addresses.
You can confirm the address by pressing the CONFIRM button.
When you send the Z command, all the light modules will turn off.
21
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
3. Operation Methods
This section describes the operation commands and control methods to control the device.
For details, refer to the following manual.
When the gate output is turned off, the gate closes after the delayed gate shut-off time (Factory setting: 2 seconds.)
Refer to the general control flow as shown below.
123
・ Open the gate according to the operation
instruction.
PiPi
PiPi
Pi
END
The operation completion response to the application is performed after the CONFIRM
button is pressed. The gate shut-off operation, however, is performed after the delayed
gate shut-off time after the CONFIRM button is pressed. Send via the application the next
operation instruction by taking into consideration of receiving the operation completion
and delayed gate shut-off time.
If you send the next operation instruction without waiting for the closing operation, the
system will move to the next operation instruction with the gate open.
Opening and closing the gate requires a large current. Do not send operation instructions
(open/close operation) to more than 6 units at the same time to one junction box. If you
want to send work instructions to 6 or more units, send the operation instructions 6 units
at a time and wait at least 800ms between operation instructions provided there are no
malfunctioning gate opening and closing.
22
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
23
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
A1.0
The quantity is decremented
Press the – key
A0.0 A0.0
24
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
error
PiPi
Retry operation
123
• If an error occurs due to an obstacle, it is detected
and the gate closes.
error error
123
123 ;;;
PiPi
PiPi PiPi
Pi Pi
・Open the gate again
・ If closing and opening are repeated twice, and if the error is not
cleared, the error 「≡≡≡」 will be displayed successively with the
content of the operation instruction to indicate that the error remains
uncorrected. Also, the gate portion will loosen or release.
PiPi
Pi
※If the operation stops due to an error, the closing operation may not happen even when
the CONFIRM button is pressed with the completion of the operation instruction.
When an error occurs, excessive current consumption is required and puts a big load on
the motor.
When confirming the error status, be sure to remove the obstacle. Two operation retries
are performed for unresolved errors. In cases where an error occurs because of an
obstacle, the problem should be solved requiring less than 2 tries.
If the operation stops due to an error, the gate may not open/close even when the
open/close operation instruction is given.
25
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Close error
123
・Press the CONFIRM button
PiPi
Pi
PiPi
Pi
When a malfunction occurs, load is put on the motor requiring excessive current
consumption. Be sure to remove the obstacle when you confirm the malfunction status.
*If the operation becomes error and the gate opens with the next operation instruction,
there may be a delay in opening the gate or may first close then reopen.
26
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
27
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
<<<
END
The unlocked state returns to the locked state when the Z command (initialization
command) or the D command (light OFF command) is received.
28
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
When opening and closing the gate, large current is required. Do not send an operation instruction (open/close
operation) to more than 6 units simultaneously on one junction box. To send an operation instruction to 6 or
more units, send 6 units at a time and wait at least 800ms between operation instructions.
Also, if the Z command is sent while multiple units are open, the operation will switch to the close operation at
the same time, and the current consumption of the junction box may exceed the rated current. For this reason,
consider using the D command (light OFF command) to close no more than six units at a time so as not to
exceed the rating.
29
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
4. Control Command
Command List
The available commands for the MWU2030FNSH are shown below.
Header Details Page
Z Initial setting
Am1 Display status
Am2 Display status after pressing CONFIRM
Am4 Specification of CONFIRM button,Fn key
Ama Specify the use of S/- key
PP1 Block operation instruction with display data specified after pressing the Fn
key.
PP5 Overwritable block operation instruction with display data specified after
pressing the Fn key.
PP1B Block operation instruction with gate open/close specification *1 p. 30
PP2B Light module display with gate open/close specification *1 p. 32
PP5B Overwritable block operation instruction with gate open/close specification *1 p. 33
D Operation termination instruction (gate closes)
t Report from the controller (※1)
PP2 Light module display
A Maintenance specification
Az Light module status inquiry
Ac Set up the light module address
*1 To use commands other than the recommended commands or commands for new applications, select the
control specification of the gate area.
For details on the above commands, refer to L-PICK Controller Command Reference.
30
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Control Command
This command is recommended for new systems.
PP1B (Block Operation Instruction with Gate Open/Close Specification)
Repeatable MA
Function
Specify the display data and send an operation instruction to the light module for a block.
(If the Mode Array is specified, the operation mode is sent to the light module.)
Format
[1 ]
P P 1 B 0 6 0 0 Bl o ck [ 2] Mo d e Arra y [ 3] Ad d re s s [ 4] D is p la y D a ta [ 5]
No.
31
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Command Example
(1) Gate open/close specification ・ Operation mode specification ・ Operation instruction
[1 ]
P P 1 B 0 6 0 0 Bl o ck [ 2] Mo d e Arra y [ 3] Ad d re s s [ 4] D is p la y D a ta [ 5]
No.
P P 1 B 0 6 0 0 0 1 m 2 32h 22h 21h 1 0 0 1 20h 20h 20h 20h 5 0
Explanation
[1] Block No.: 01
[2] Specify display status after pressing CONFIRM
[3] Light module address 1001
[4] Display data “ 5”
[5] Gate specification: Close the gate
・・・ [ 3] A d d re s s [ 4] D is p la y D a ta [ 5] [ 3] A d d re s s [ 4] D is p la y D a ta [ 5]
1 0 0 1 0 0 0 1 5 1 1 0 0 2 0 0 0 0 1 1
Explanation:
[1] Block No.: 01
[2] Mode array: omitted
[3] Display address: 1001,1002
[4] Display data: “00015”, “00001”
[5] Gate specification: Open the gate
Operation
Multiple operation instructions, including the open/close gate specification, are sent in block units all at once.
Note
For repeatable, specify to not exceed the maximum command length.
32
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Function
Turn the light module ON.
Format
P P 2 B 0 6 0 0 [ 1] Mo d e Arra y [ 2] Ad d re s s [ 3] D is p la y D a ta [ 4]
Command Example
Gate open/close specification ・Operation mode specification ・Operation instruction
P P 2 B 0 6 0 0 [ 1] Mo d e Arra y [ 2] Ad d re s s [ 3] D is p la y D a ta [ 4]
Explanation:
[1] Specify display status after pressing CONFIRM
[2] Module address: 1001
[3] Display data: " 5"
[4] Gate specification: Open the gate
Note
(1) To send an operation instruction command to the displayed light module, first send the termination
command (D).
(2) If ???? is specified for the module address, the display of the light module may become strange. To send
to all light modules, specify 0??? ~ 7???.
(3) For repeatable, specify to not exceed the maximum command length.
Supplement
Used for modules where completion is not required (normal completion or shortage of stock). Pressing the
CONFIRM button will turn off the display by default. For this reason, it is recommended to set CONFIRM / Fn
key to not use (Am4, M).
33
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Function
Specify the display data, and send an overwritable operation instruction to the light module by block.
(If Mode Array is specified, the operation mode is sent to the light module.)
Format
[1 ]
P P 5 B 0 6 0 0 Bl o ck [ 2] Mo d e Arra y [ 3] Ad d re s s [ 4] D is p la y D a ta [ 5]
No.
34
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Command Example
(1) Gate open/close specification ・ Operation instruction
[1 ]
P P 5 B 0 6 0 0 Bl o ck [ 2] Mo d e Arra y [ 3] Ad d re s s [ 4] D is p la y D a ta [ 5]
No.
P P 5 B 0 6 0 0 9 9 m 2 31h 11h 21h 1 2 0 1 20h 20h 20h 1 5 1
Explanation:
[1] Block No.: 99
[2] Specify display status after pressing CONFIRM
[3] Light module address: 1201
[4] Display data: “ 15”
[5] Gate specification: Open the gate
Explanation:
[1] Block No: 00
[2] Mode array: omitted
[3] Light module address: 0001
[4] Display data: “00012”
[5] Gate specification: Close the gate
Operation
Multiple operation instructions, including the open/close gate specification, are sent by block unit all at once.
It can be sent to a light module that is in operation instruction (Overwrite).
Note
For repeatable, specify to not exceed the maximum command length.
35
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
5. Special Menu
With the MWU2030FNSH light module, you can set up Open/close Angle, Delayed Shut-off Time, Address,
and Open/close Speed.
This chapter describes how to operate the special menu.
START
;;;
「 ≡≡≡ 」 lights up on 7-SEG and the special
menu is displayed.
F2
Press the CONFIRM button Special Menu [F2]
36
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
【F1】Display status
f1
000
Displays the current address 0000.
*Because only 3 digits can be displayed, only the
last 3 digits of the address will be displayed.
Press the CONFIRM button
1 - 0
Display the value of the thousands place.
7-SEG lights up and displays [1-X]. *X: address
Press the S key +1
Press the S key or the - key to change the address until it
Press the -key -1
reaches 1, then press the CONFIRM button to confirm.
1-1
【F2】Display status
37
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
1 - 0
Displays the setting of 10-seconds.
7-SEG lights up and displays 「1-X」. *X: time
Press the S key +1 Press the S key or the - key to change the setup time until
Press the -key -1 it reaches [0]. Then press the CONFIRM button to confirm.
1-0
【F3】Display status
38
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Open/Close angle
【F3】Display status
F3
【F4】Display status
39
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Open/Close angle
【F3】Display status
F3
on
【F4】Display status
40
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
【F4】Display status
F4
1-1
Display the open/close speed.
7-SEG lights up and displays 「1-X」. *X: setting value
Press the S key +1 Press the S or - key to change the value until it reaches 「2」,
Press the- key -1 then press the CONFIRM button to confirm.
*If you change from the current value, the LED will light up
1-2 momentarily and the buzzer will beep.
Peep
【F5】Display status
41
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
【F5】Display status
F5
1-1
Displays the setting at 10 degrees.
7-SEG lights up and displays 「1-X」. *X: angle
Press the S key +1
Press the S or - key to change the angle until it reaches 「2」,
Press the -key -1
then press the CONFIRM button to confirm.
1-2
【END】Display status
42
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
6. NFC Communication
The MWU2030FNSH has NFC functions.
The following settings can be configured on an NFC-enabled Android smartphone.
・Address setting
・Open/Close angle setting
・Close delay time setting
For details on the NFC function, please refer to the following manual.
Download the Android application for setting the device from the user manual.
※This application may not work depending on the model of the smart phone.
43
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
7. External Dimensions
44
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
45
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
【mm】
【mm】
46
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Device Specification
Details
Number of
Connected Units Maximum number of connected units per controller: 7,999 units
per System
Configurable
0001 ~7999
Addresses
Wiring Cable Dedicated AI cable: Maximum 30m with 1.5sq cable
Length
Supplied from TW2209 (12V Junction Box)
Maximum current during polling: 0.21A
Power Peak current during gate operation: 4.2A
Maximum number of units that can be connected to each TW2209:
115 units *1 *2
Connectable Units
Maximum number of units that can be connected to each channel:
per 1 ch for Each
23 units *1 *2
Junction Box
Key Operation
1,000,000 times or more *3
Guarantee
Temperature and
0 ~ 35℃, 20 ~ 80% (No condensation)
humidity condition
External
149.5(W) x 41.6(D) x 28(H) mm (Excluding protrusions) *4
Dimensions
Weight 150g *4
*1 Note that the simultaneous opening/closing operation of the gates should be fewer than 6 units per 1 junction box.
*2 If the number of gates that open and close simultaneously increases, the maximum number of connectable units will
decrease according to the ratio.
*3 Guaranteed if the pressing force is less than 10N. If the pressing force is greater than 10N, the key operation will be
fewer than 1 million times or may cause damage to the key.
*4 Excludes the gate.
47
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
Gate Specification
Details
Maximum Gate
100g (Refer to recommended gate size)
Weight
*5 As soon as the safety circuit is activated, immediately stop the rotation. To recover, it is necessary to stop
the control, then give an output drive instruction again.
List of Settings
Light Module
0001 ~ 7999 0000 *6
Address
【Outward open type】
Open:200 degree-angle
Close: 45 degree-angle
Open/Close Angle 0 ~ 270 degrees (000 ~ 270)
【Inward open type】
Open: 45 degree-angle
Close: 135 degree-angle
48
MWU Series NFC Poka-yoke Gate Light Module User’s Manual Ver.1.1
9. Troubleshooting