** ON A/C ALL
TASK 56-11-12-200-001-A
Inspection of the Fixed Windows
C. Referenced Information
REFERENCE DESIGNATION
(Ref. 56-10-00-110-002-A). Cleaning of the L/R Fixed Windows
(Ref. 56-10-00-200-004-A). Measurement of Scratch Depth with MITUTOYO Surface Tester SJ201
(Ref. 56-10-00-200-004-A-01). Measurement of Scratch Depth with MITUTOYO Surface Tester SJ210
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
REFERENCE DESIGNATION
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Permitted Damage SHEET 1
Acrylic Fixed Window - Burn Spot Inspection Procedure SHEET 1
Acrylic Fixed Window - Crazing Inspection Procedure SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Permitted Damage SHEET 1
Glass Fixed Window - Burn Spot Inspection Procedure SHEET 1
INNER PLY
NOT ACCEPTABLE
N_MM_561112_6_ACM0_01_00
INNER PLY
N_MM_561112_6_AEM0_01_00
CHIP
1 mm
(0.039 in.) MAXIMUM DEPTH : 1 mm(0.039 in.)
ACCEPTABLE IF THE CHIPS ARE IN THE TOLERANCE
N_MM_561112_6_AGM0_01_00
AREA B
X X
AREA A
X = 76 mm (2.99 in)
R = 76 mm (2.99 in)
NOTE:
THERE ARE STRESS-RELIEVING SEPARATORS ABOVE THE BUSBARS IN THE VISION AREA.
IT IS POSSIBLE TO THINK THAT THEY ARE DELAMINATION AREAS.
N_MM_561112_6_AJM0_01_04
DISCOLORATION OR BURNING
TRANSPARENCY
N_MM_561112_6_ALM0_01_00
SERIES OF FISSURES PERPENDICULAR TO THE CRAZING OVER THE ENTIRE OUTER SURFACE
SURFACE BUT NOT EXTENDING THROUGH IS ACCEPTABLE PROVIDED THE DEPTH DOES
THE PANEL NOT EXCEED 0.5 mm (0.02 in.)
SURFACE BREAKS ARE NOT VISIBLE AND IT IS
SOMETIMES ONLY POSSIBLE TO VIEW FROM
AN ANGLE SUCH THAT LIGHT IS REFLECTED
OFF THE FISSURE SURFACE
CRAZING IS CAUSED BY STRESS AND OR
CONTAMINATION
N_MM_561112_6_AMM0_01_00
BURN SPOT
BUS BAR AND CONDUCTIVE ELEMENT SWITCH OFF THE SIDE FIXED WINDOW HEATING
LOCATION AS FOLLOWS:
- OPEN,SAFETY AND TAG THE CIRCUIT BREAKERS
FOR THE LEFT SIDE:4DG1 (122VU)
FOR THE RIGHT SIDE:4DG2 (122VU)
BUS BAR
ACCEPTABLE
- IF THE DIAMETER OF THE MARKS ARE LESS
THAN 10mm (0.39in.)
CONDUCTIVE
ELEMENT
N_MM_561112_6_AQM0_01_00
N_MM_561112_6_FAQ0_01_00
A
A
B
A
SECTION
B
B-B
LIGHT SOURCE 45°
(45° TO THE SURFACE)
BUS BAR
N_MM_561112_6_FAM0_01_00
Figure 56-11-12-991-01300-00-A / SHEET 1/1 - Acrylic Fixed Window - Burn Spot Inspection Procedure
** ON A/C ALL
SCALE
LINE OF SIGHT
APPROX.
45°
CRAZING
SCALE REFLECTION
LINE OF SIGHT
N_MM_561112_6_GAM0_01_00
Figure 56-11-12-991-01400-00-A / SHEET 1/1 - Acrylic Fixed Window - Crazing Inspection Procedure
** ON A/C ALL
CRACKS
N_MM_561112_6_GCM0_01_01
INNER PLY
ACCEPTABLE:
IF YOU CANNOT FEEL THE SCRATCHES
WHEN YOU TOUCH THE FIXED WINDOW
WITH YOUR FINGER NAIL OR
IF THE DEPTH OF THE SCRATCHES MEASURED
WITH THE MITUTOYO SURFACE TESTER SJ201/SJ210 IS LESS THAN
0.05mm (0.0019in.) (REF. TASK 561000-200-004).
NOT ACCEPTABLE:
IF YOU CAN FEEL THE SCRATCHES WHEN YOU
SCRATCHES TOUCH THE FIXED WINDOW WITH YOUR FINGER
NAIL OR
IF THE DEPTH OF THE SCRATCHES MEASURED WITH
THE MITUTOYO SURFACE TESTER SJ201/SJ210 IS MORE THAN
0.05mm (0.0019in.) (REF. TASK 561000-200-004).
N_MM_561112_6_GEM0_01_01
CHIP
NOT ACCEPTABLE
MIDDLE PLY
NOT ACCEPTABLE
N_MM_561112_6_GGM0_01_00
AN AREA WITH DELAMINATION CAN AREA B: MAKE SURE THAT THE DELAMINATION AREA
BE TRANSPARENT BUT IT WILL IS NOT MORE THAN 76.20 mm (3.0 in) FROM
BECOME CLOUDY IF MOISTURE GETS THE INNER EDGE OF THE VISION AREA.
INTO IT.
DELAMINATION LIMITS
AREA B
X X
AREA A
N_MM_561112_6_GJM0_01_02
DISCOLORATION
SEALANT MIGRATION
HEATING ELEMENT
BUS
BAR
SEALANT MIGRATION
OUTER FACE
TRANSPARENCY
N_MM_561112_6_GLM0_01_00
INTERLAYER MICROFLAKES
X X
AREA A
X = 76.2mm (3in.)
R = 76.2mm (3in.)
DETAIL OF INTERLAYER MICROFLAKES
WINDOW
PANEL
N_MM_561112_6_GRM0_01_00
BURN SPOT
BUS BAR AND CONDUCTIVE ELEMENT SWITCH OFF THE SIDE FIXED WINDOW HEATING
LOCATION AS FOLLOWS:
- OPEN SAFETY AND TAG THE CIRCUIT BREAKERS
FOR THE LEFT SIDE:4DG1 (122VU)
FOR THE RIGHT SIDE:4DG2 (122VU)
BUS BAR BUS BAR
ACCEPTABLE
- IF THE DIAMETER OF THE MARKS ARE LESS
THAN 10mm (0.39in.)
CONDUCTIVE
ELEMENT
N_MM_561112_6_GQM0_01_00
N_MM_561112_6_NAN0_01_00
B B
BUS BAR AREA
BUS BAR
N_MM_561112_6_GMM0_01_00
Figure 56-11-12-991-02100-00-A / SHEET 1/1 - Glass Fixed Window - Burn Spot Inspection Procedure
** ON A/C ALL
3. Job Set-up
Subtask 56-11-12-941-051-A
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the windshield at zone
210.
(2) Clean the fixed windows (Ref. AMM TASK 56-10-00-110-002) .
Subtask 56-11-12-865-059-A
WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE
OPENED, SAFETIED AND TAGGED.
** ON A/C 001-002
121VU COM NAV/RADAR/2 5SQ2 K14
** ON A/C ALL
121VU COM NAV/RADAR/1 5SQ1 K13
122VU ANTI ICE/WINDOWS/R 4DG2 W14
122VU ANTI ICE/WHC/2 5DG2 W13
122VU ANTI ICE/WINDOWS/L 4DG1 X14
122VU ANTI ICE/WHC/1 5DG1 X13
123VU ANTI ICE/L/WHSLD 1DG1 AF10
123VU ANTI ICE/R/WHSLD 1DG2 AF03
4. Procedure
Subtask 56-11-12-220-051-A
A. Inspection of the Fixed Windows
(1) Inspection of the acrylic fixed windows (GKN (formerly LUCAS/ACT) supplier, P/N NH...)
NOTE: "Impaired": in inspection tables the word "impaired" refers to visibility. Visibility is "impaired"
when defects have an effect on visibility. If visibility is "impaired", you must replace the win-
dow panel.
NOTE: You can also use an MICROMETER - OPTICAL as an alternative to the metal scale.
2 Put the metal scale perpendicular to the surface of the sliding window panel where you see
the maximum depth of crazing.
3 Look at the scale reflection with an angle of vision of 45 deg. to find the apparent depth of
the crazing damage.
4 The correct depth is approximately two times the apparent depth.
5 Where the depth of crazing is minimum, a MAGNIFYING GLASS POWER 10X can be used
as an optical aid.
(2) Inspection of the glass fixed windows (PPG supplier, P/N NP... and SGS (formerly SPS) supplier, P/N
SPS...)
NOTE: "Impaired": in inspection tables the word "impaired" refers to visibility. Visibility is "impaired"
when defects have an effect on visibility. If visibility is "impaired", you must replace the win-
dow panel.
5 Bubbles
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
6 Discoloration
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
7 Transparency
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
8 Interlayer microflakes
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
9 Burn spots
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
10 Heating film cracking.
(Ref. Fig. Glass Fixed Window - Permitted Damage SHEET 1)
(b) Do a check for burn spots.
(Ref. Fig. Glass Fixed Window - Burn Spot Inspection Procedure SHEET 1)
1 Put a LIGHT SOURCE - WHITE at 45 deg. to the outer surface of the window panel.
2 Do a check of the bus bar for burn spots.
5. Close-up
Subtask 56-11-12-865-060-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
** ON A/C 001-002
121VU COM NAV/RADAR/2 5SQ2 K14
** ON A/C ALL
121VU COM NAV/RADAR/1 5SQ1 K13
122VU ANTI ICE/WINDOWS/R 4DG2 W14
122VU ANTI ICE/WHC/2 5DG2 W13
122VU ANTI ICE/WINDOWS/L 4DG1 X14
122VU ANTI ICE/WHC/1 5DG1 X13
123VU ANTI ICE/L/WHSLD 1DG1 AF10
123VU ANTI ICE/R/WHSLD 1DG2 AF03
Subtask 56-11-12-942-054-A
B. Close Access
(1) Remove the access platform(s).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other
items.
Figure 56-11-12-991-00500-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-00600-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-00700-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-00800-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-00900-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-01000-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-01100-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-01200-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-01300-00-A / SHEET 1/1 - Acrylic Fixed Window - Burn Spot Inspection Procedure
Figure 56-11-12-991-01400-00-A / SHEET 1/1 - Acrylic Fixed Window - Crazing Inspection Procedure
Figure 56-11-12-991-01500-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-01600-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-01700-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-01800-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-01900-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-02000-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage
Figure 56-11-12-991-02100-00-A / SHEET 1/1 - Glass Fixed Window - Burn Spot Inspection Procedure
Figure 56-11-12-991-07400-00-A / SHEET 1/1 - Acrylic Fixed Window - Permitted Damage
Figure 56-11-12-991-07500-00-A / SHEET 1/1 - Glass Fixed Window - Permitted Damage