Professional Documents
Culture Documents
Scaling Applications
on Cloud Linear Scale in the Cloud
Storage Reliability
and Performance Performance with TCO Savings
Using FSS and SmartIO Using GCO & VVR, with VPN Tunnel
Cloud Inter-region HA/DR
• SmartIO read caching using local SSDs or persistent SSDs for better
application performance
APP DB
• 2x plus performance with almost same cost
InfoScale • Overcome IOPS capacities of VM
100
IOPS (K)
• SSD Persistent Disk – 1TB, 30K maximum 80
read/write IOPS 60
40
• Standard Persistent Disk – 2560G, 3k 20
maximum read IOPS and 15k write IOPS
0
4k 8k 16k 32k 64k 128k 256k 512k
• Reference - IO Size
https://cloud.google.com/compute/docs/dis Local SSD SSD Persistent Standard Persistent Disks
ks/performance
7 InfoScale Enterprise VSE+ Training
Scale & Performance
Performance Characterization
Performance Considerations
• Use of local SSDs to overcome IOPS limits of VM and persistent block storage
Throughput (MB/s)
60
IOPS (K)
1000
SmartIO Performance 40
500
SSD persistent disks for base volume and local 20
Cost/IOPS ($$)
1.400
• VM – 32vCPU, 120G memory 1.200
1.000
0.800
0.600
0.400
• Local SSD (nvme) – 2 x 375G per node 0.200
0.000
4k 8k 16k 32k 64k 128k 256k 512k
Non-SmartIO 0.071 0.071 0.071 0.093 0.187 0.380 0.750 1.494
• SSD Persistent Disk – 4 x 256G per node, SmartIO 0.037 0.041 0.047 0.062 0.123
IO Size
0.274 0.501 0.987
Throughput (MB/s)
40000 400
IOPS
20000 200
Standard persistent disks for base volume and 10000 100
local SSDs (nvme) for cache volume 0 0
4k 8k 16k 32k 64k 128k 256k 512k
IO Size
• 2 node FSS cluster across zones
Non-SmartIO (IOPS) SmartIO (IOPS)
Non-SmartIO (Throughput MB/s) SmartIO (Throughput MB/s)
• FIO workload with 70/30 read/write, 16
jobs, 4 iodepth Cost/IOPS
12.000
Cost/IOPS (MB/s)
10.000
• VM – 32vCPU, 120G memory 8.000
6.000
4.000
• Standard Persistent Disk – 4 x 2560G per SmartIO 0.057 0.083 0.135 0.240 0.452 0.900 1.802 3.615
IO Size
node, 3k maximum read IOPS and 15k
write IOPS Non-SmartIO SmartIO
Throughput (MB/s)
30000 400
SmartIO Performance 300
IOPS
20000
Standard persistent disks for base volume and 200
10000
SSD persistent disks for cache volume 100
0 0
4k 8k 16k 32k 64k 128k 256k 512k
• FIO workload with 70/30 read/write, 16 Non-SmartIO (Throughput MB/s) SmartIO (Throughput MB/s)
jobs, 4 iodepth
Cost/IOPS
12.000
• VM – 32vCPU, 120G memory
Cost/IOPS ($$)
10.000
8.000
6.000
60000
10.000
50000
8.000
Cost/IOPS ($$)
40000
IOPS
6.000
30000
4.000
20000
2.000
10000
0 0.000
4k 8k 16k 32k 64k 128k 256k 512k
IO Size
Non-SmartIO (Standard Persistent Disks) SmartIO (SSD Persistent Disks + Standard Persistent Disks) SmartIO (Local SSDs + Standard Persistent Disks)
Non-SmartIO (SSD Persistent Disk) SmartIO (Local SSDs + SSD Persistent Disks) Non-SmartIO (Standard Persistent Disks)
SmartIO (SSD Persistent Disks + Standard Persistent Disks) SmartIO (Local SSDs + Standard Persistent Disks) Non-SmartIO (SSD Persistent Disk)
SmartIO (Local SSDs + SSD Persistent Disks)
• Performance at Scale
• Application Aware
APP DB WEB
• Run parallel application using
shared storage in an Active-
10 Ge 10 Ge Active Setup
InfoScale InfoScale InfoScale
Scale-Out DAS ClusterScale-Out DAS Cluster • Run multiple applications in
a shared infrastructure
Replication
Region Region
Global Cluster
Regional Failover
Replication
• File Type
• Age
Copyright © 2017 Veritas Technologies. All rights reserved. Veritas and the Veritas Logo are trademarks or registered trademarks of Veritas Technologies or its affiliates in the
U.S. and other countries. Other names may be trademarks of their respective owners.
This document is provided for informational purposes only and is not intended as advertising. All warranties relating to the information in this document, either express or
implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice.