You are on page 1of 8

Name of site = Yokohama Tire_Philippines

Latitude [?] = 15.172, Longitude [?] = 120.572, Altitude [m] = 425


Climatic zone = V, 2

Radiation model = Default (hour); Temperature model = Default (hour)


Diffuse radiation model = Default (hour) (Perez)
Tilt generation model = Default (hour) (Perez)
Radiation: New period = 1991-2010
Temperature: New period = 2000-2009

Month H_Gh H_Dh H_Gk H_Dk H_Bn Ta

Jan 140 58 139 58 135 23.9


Feb 148 61 146 61 131 24.5
Mar 196 63 195 63 194 25.7
Apr 197 70 197 70 186 27.2
May 182 73 183 73 153 26.7
Jun 161 86 162 87 106 26.1
Jul 153 82 153 82 99 25.5
Aug 140 78 140 78 88 25.1
Sep 141 71 140 71 101 25.2
Oct 140 70 139 70 106 25.3
Nov 134 54 132 54 129 25
Dec 137 54 135 54 139 24.2

Year 1870 821 1861 822 1565 25.4

Legend:

H_Gh: Irradiation of global radiation horizontal


H_Dh: Irradiation of diffuse radiation horizontal
H_Gk: Irradiation of global rad., tilted plane
H_Dk: Irradiation of diffuse rad., tilted plane
H_Bn: Irradiation of beam
Ta: Air temperature

Radiation in [kWh/m?]
Temperature in [?C]
Gh: Only 2 station(s) for interpolation
Ta: Only 3 station(s) for interpolation
Rh: Only 3 station(s) for interpolation
SD: Mean values of climate zone
RD: Mean values of climate zone
Nearest 3 stations: Gh: Science Garden (77 km), Manila/Naia (86 km)
Nearest 3 stations: Ta: CABANANATUAN/LUZON (54 km), Iba/Luzon Island (68 km), OLONGAPO (53 km)
Azimuth = 111?, Inclination = 3?
Uncertainty of yearly values: Gh = 7%, Bn = 14%, Gk = 7%, Ta = 0.8 ?C
Trend of Gh / decade = -8.2%
Variability of Gh / year = 8.4%
Location Yokohama tire-factory
Altitude 0m Inveter Efficiency 98.1%
Latitude 15.172 黄色、赤色セル DC Cable Loss 1.00%
Longitude 120.572 は AC Cable Loss 0.99%
全て手入力 Tranformer Loss 98.50%
Module type Crystalline
System capacity 1,329.75 kW 日付 11/19/2020
System type Roof mount type
Inclination 3°
Azimuth NW

K =Kh×Kp×Kb×Kc ▼"青文字"の箇所を選択して下さい 0.83


###
Kh =Khd×Khs×Khc 1.00
###
Kp =Kpd×Kpt×Kpa×Kpm 0.85
###
Kpd = Kpds×Kpdd×Kpdr 計算値→ 0.94
###
Kpds JIS推奨値 0.98
###
Kpdd = (1-dnp)^nyl JIS推奨値 結晶系 ###
1.0
dnp -
nyl -
Kpdr = Kpdrs×Kpdrn 計算値→ 0.960
###
Kpdrs SHARP結晶系 0.99
###
Kpdrn JIS推奨値 0.97
###
Kpt = 1+αpmax×(Tcr-Ts) 計算値→ 0.95
###
αpmax SHARP結晶系 -0.00485
###
Tcr = Ta+⊿Tcr 実測データ→ 37.0
###
Ta 実測データ→ 15.5
###
⊿Tcr Roof mount type 21.5
###
Ts ###
25
Kpa (Kpal) = 1-(0.6×ζa+ζb) リンク→ 0.990
###
ζa -
ζb = Vbd/V -
V -
Vbd
Kpm 個別入力 0.965
###
Kb =(1-γba)×ηbd+γba×ηba 蓄電池無し ###
1
Kc =γdc×Kdd+(1-γdc)×Kin 0.98
###
1,330kW photovoltaics power generation simulation in Yokohama tire-factory
PV module type : Crystalline

Epd : power generation [kwh/day]


U : Irradiation of global radiation [kWh/m2 ・ day]
U  ・   P P : System output power [kW]
Fomula Epd  =   ・  K'  ・   Kpt ・   K'' Po : correction irradiation( =1 kW/m2)
Po K' : correction coefficient [-]
Kpt : temperature coefficient [-]

Site name Yokohama tire-factory Irradiation of Power generation


Latitude 15.172 Month global radiation Temp. Kpt Production per day Days Production per month

Logitude 120.572 [kWh/m2・day] [kWh/day] [day/month] [kWh/month]


Altitude 0m Jan 4.48 23.9 0.918 4,855.8 31 150,530
Azimuth NW Feb 5.21 24.5 0.916 5,632.1 28 157,698
Inclination 3 ° Mar 6.29 25.7 0.911 6,758.7 31 209,520
Output power P 1,329.75 kW Apr 6.57 27.2 0.905 7,009.2 30 210,275
Correction coefficient K' 0.887 May 5.90 26.7 0.907 6,314.9 31 195,763
Shade by Array and
Lightning Lod Kh 0.990 Jun 5.40 26.1 0.910 5,791.9 30 173,757
Soil Loss Kpds 0.980 Jul 4.94 25.5 0.912 5,307.6 31 164,537
Deterioration coef. Kpdd 1.000 Aug 4.52 25.1 0.914 4,865.2 31 150,821
Reflection, Spectral
Respondence coef. Kpdr 0.960 Sep 4.67 25.2 0.913 5,025.2 30 150,755
DC cable loss coef. Kpa 0.985 Oct 4.48 25.3 0.913 4,826.2 31 149,612
Array load matching coef. Kpm 0.980 Nov 4.40 25.0 0.914 4,742.2 30 142,265
Power conditioner coef. Kc 0.986 Dec 4.35 24.2 0.917 4,709.9 31 146,008
Temp. coefficient Kpt Right table Ave. 5.10 25.4 0.91253 total 365 2,001,542
Panel temp.coef. -0.4 %/°C Annual power
Weighted temp. average 21.5 °C generation 2,001,542 kWh/year
System type Roof mount type
Losses K'' 1.000
【 Note 】
Correction coef. of AC cable loss 1.000 ・ Climate Data is adapted from METEONORM.
Transformer efficiency22k 1.0000 ・ Formula is based on the Japanese Industrial Standard (JIS C 8907).
Transformer efficiency115 1.0000
Auxiliary Consumption 1.000

Capacity factor: 17.2% 0.315


Performance Ratio 80.92%
72,588
0.989024

計算条件
・影ロス0.5%。
・汚れロス2%。
・1年目の出力レベルはNominal値の97%、と期待。
・22kVパワーメーター出力端で出力を計測し、その値で保証する。
【 The estimation of PV power generation 】 19/11/20
Location Yokohama tire-factory
Latitude 15.172
Longitude 120.572
Module type Crystalline
System capacity 1,329.75kW
System type Roof mount type
Inclination 3°
Azimuth NW
Inverter euro-eta 98.6%
PV power production
Irradiation of Ambient
MONTH

global radiation Temperature Daily power Monthly power


Days
generation generation
[kWh/m2・day] [°C] [kWh/day] [day/month] [kWh/month]
JAN 4.48 23.9 4,855.8 31 150,530
FEB 5.21 24.5 5,632.1 28 157,698
MAR 6.29 25.7 6,758.7 31 209,520
APR 6.57 27.2 7,009.2 30 210,275
MAY 5.90 26.7 6,314.9 31 195,763
JUN 5.40 26.1 5,791.9 30 173,757
JUL 4.94 25.5 5,307.6 31 164,537
AUG 4.52 25.1 4,865.2 31 150,821
SEP 4.67 25.2 5,025.2 30 150,755
OCT 4.48 25.3 4,826.2 31 149,612
NOV 4.40 25.0 4,742.2 30 142,265
DEC 4.35 24.2 4,709.9 31 146,008
Avr. 5.10 25.4 Total 365 2,001,542

D
h ahr an Dh a h ra n
II
n n
ccl l
i i
n n
at
ati i
onon  22°
17°
20°
Ji
dda T ot al

P
D
o
uba
L
t
r o
i
ui
s
Doha
Lj
uba na
j
l
D
h ahr an Dh a h ra n
II
n n
ccl l
i i
n n
at
ati i
onon  22°
17°
20°
Ji
dda T ot al

P
D
o
uba
L
t
r o
i
ui
s
Doha
Lj
uba na
j
l
モジュール劣化率入力シート

参考値
手入力↓ (当社提案時の標準値、実力値ではないこと注意)
(右記参考の上)
薄膜 結晶

モジュール モジュール仕
Year モジュール劣化率
標準リニア 仕様書での 標準リニア 様書での
手入力
保証記載値 保証記載値

1 97.50% 0.00% 98.00% 2% 85.50% 85.50%


2 97.50% 0.00% 97.00% 1.00% 85.50% 85.50%
3 96.90% 0.60% 96.00% 1.00% 85.50% 85.50%
4 96.30% 0.60% 95.00% 1.00% 85.50% 85.50%
5 95.70% 0.60% 94.00% 1.00% 85.50% 85.50%
6 95.10% 0.60% 93.00% 1.00% 85.50% 85.50%
7 94.50% 0.60% 92.00% 1.00% 85.50% 85.50%
8 94.50% 0.00% 91.00% 1.00% 85.50% 85.50%
9 94.50% 0.00% 90.00% 1.00% 85.50% 85.50%
10 94.50% 0.00% 90.00% 0.00% 85.50% 85.50%
11 88.50% 6.00% 90.00% 0.00% 76.00% 76.00%
12 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
13 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
14 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
15 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
16 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
17 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
18 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
19 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
20 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
21 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
22 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
23 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
24 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%
25 88.50% 0.00% 90.00% 0.00% 76.00% 76.00%

100.00%

95.00%

90.00%

手入力
85.00% 薄膜リニア標準
薄膜モジュール保証値
結晶リニア標準
結晶モジュール保証値
80.00%

75.00%
結晶リニア標準
結晶モジュール保証値
80.00%

75.00%

70.00%
1 2 3 4 5 6 7 8 9 10111213141516171819202122232425
【 The estimation of PV power generation for 25 years 】
2,001,542 80.92% ←劣化率含まず
Expected value (not for Warranty) Warranty value
Power Output*4 Capacity Performance Global
(Expected) Annual Factor*2 irradiance Power Output
Tilt angle 10°劣 Degradation Plant available (Expected) Ratio*1 (Expected)
Years 化率、稼働率含 Percentage factor*3 劣化率、稼働率 劣化率含む Inclination Tilt angle 10°
む (Expected) (Expected) 含む 稼働率含まず 補機動力ロス含まず
温度ロス含む 温度ロス含む 温度ロス含む

1 1st 1,912MWh 97.50% 98% 16.41% 78.90% 1,912MWh
2 2nd 1,912MWh 97.50% 98% 16.41% 78.90% 1,912MWh
3 3rd 1,901MWh 96.90% 98% 16.31% 78.41% 1,901MWh
4 4th 1,889MWh 96.30% 98% 16.20% 77.93% 1,889MWh
5 5th 1,877MWh 95.70% 98% 16.10% 77.44% 1,877MWh
6 6th 1,865MWh 95.10% 98% 16.00% 76.95% 1,865MWh
7 7th 1,854MWh 94.50% 98% 15.90% 76.47% 1,854MWh
8 8th 1,854MWh 94.50% 98% 15.90% 76.47% 1,854MWh
9 9th 1,854MWh 94.50% 98% 15.90% 76.47% 1,854MWh
### 10th 1,854MWh 94.50% 98% 15.90% 76.47% 1,854MWh
0kWh/m2/year
### 11th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 12th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 13th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 14th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 15th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 16th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 17th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh
### 18th 1,736MWh 88.50% 98% 14.89% 71.61% 1,736MWh

Degradation Ratio
AC Power output

### 19th 1,736MWh PV Power Generation


88.50% for 25 years
98% 14.89% 71.61% AC Power output 1,736MWh
### 20th 1,736MWh (Expected) 88.50% 98% 14.89% 71.61% Degradation Ratio 1,736MWh
Total 2500MWh
36,131MWh 12.40% 36,131MWh
100.00%
90.00%
2000MWh
80.00%
70.00%
1500MWh 60.00%
50.00%
1000MWh 40.00%
30.00%
500MWh 20.00%
10.00%
0MWh 0.00%
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Year

You might also like