You are on page 1of 5

Changes to Schemas V8i

- Added to schema C:\ProgramData\Bentley\OpenPlantPID


(SS6)\WorkSpace\OPPID\schemas\OpenPlant.01.07.ecschema.xml the class special_piping

- The properties shown below are added to the piping_special class

- The properties shown below are added to the name property in the piping_special class. In the
ECexpression in calculated ECProperty specification property is modified according to the GHD ( or
Client) asset tagging.

- its modified the tag style of equipment, fluid_regulator,piping_network_system and piping special
classes in the schema OpenPlant_Supplemental_Tagging.01.07.ecschema.xml according to GHD asset
tagging.

piping_network_system

-the properties descriptions 1,2,3 are added in the equipment class in the schema
OpenPlant.01.07.ecschema.xml

the GHD Border A1 class is added to the the schema OpenPlant_PID.01.07.ecschema.xml located in
C:\ProgramData\Bentley\OpenPlantPID (SS6)\WorkSpace\Projects\OPPIDV8i\Dataset\schemas\

and is added the attribute schematics CAD Custom Attributes

in the border list class is added to the list the class created
The cell of the border is added to the Miscellaneous.cel file

In the schema OpenPlant_PID.01.07.ecschema.xml Property NAME of the class Fluid Regulator is edited
as shown in the picture below

ins the same class the Property DEVICE_TYPE_CODE is edited as shown below

In the schema OpenPlant.01.07.ecschema.xml the class Fluid regulator is edited and is added the
property DEVICE_TYPE_SPEC

In the schema OpenPlant_PID.01.07.ecschema.xml the FLUID_REGULATOR class is edited. the property


DEVICE_TYPE_SPEC is override and is added the property annotation customs Attribute

In the schema OpenPlant_PID.01.07.ecschema.xml the VALVE class is edited. the property


INHERIT_INRUN_TEMPLATE is edited adding the property "property custom attribute" as shown below

In the schema OpenPlant_PID.01.07.ecschema.xml the PIPING_COMPONENT class is edited. the property


INHERIT_INRUN_TEMPLATE is added

In the schema OpenPlant_PID.01.07.ecschema.xml the INSTRUMENT class is edited. the property


INHERIT_INRUN_TEMPLATE is added

In the OpenPlant_PID.01.07.ecschema.xml schema are added the BUTTERFLY_VALVE_CLOSED,


BALL_VALVE_CLOSED, GLOBE_VALVE_CLOSED classes.
In the schema OpenPlant_PID.01.07.ecschema.xml the class Off_page_connector is edited. the
properties Service, Label, Notes and PID Number.

- the PIDProjectTemplates.dgnlib file is edited to match the color of P&ID components with the standard.
the file is located in C:\ProgramData\Bentley\OpenPlantPID
(SS6)\WorkSpace\Projects\OPPIDV8i\Dataset\dgnlibs.

it´s added the UTILITY_PIPING_NETWORK_SYSTEM, UTILITY_PIPELINE, VENDOR_PIPELINE classes

it's added the classes C_PIPE_INSULATION_HEAT_TRACED to OpenPlant_PID.01.07.ecschema.xml


schema and modified the class PIPING_INSULATION and PIPE_INSULATION.

it's added the class PINCH_VALVE_CLOSED, DIAPHRAGM_VALVE_CLOSED,


PLUG_VALVE_CLOSED,NEEDLE_VALVE_CLOSED, FOIR WAY GATE VALVE, FOUR WAY BALL VALVE, THREE
WAY BALL VALVE, THREE WAY GATE VALVE to OpenPlant_PID.01.07.ecschema.xml schema.

The template for the instruments lines are edited to white color.

In the schema OpenPlant_PID.01.07.ecschema.xml the PIPING_SPECIAL class is added as shown below.


then are added classes that categorizes types of special items as coil heater, steam trap, etc.

In the schema OpenPlant.01.07.ecschema.xml are added properties to the PIPING_SPECIAL Class.

In the schema OpenPlant.01.07.ecschema.xml is added in the property DATA_SHEET_NO the property


category.

In the schema OpenPlant.01.07.ecschema.xml is added the property VALVE_SPEC_TEXT the and in this
property the is added the properties shown in

-In the schema OpenPlant.01.07.ecschema.xml is added the custom attribute

to the Piping_Special Class is written the associated item class list shown above

In the schema OpenPlant.01.07.ecschema.xml is added the vent_point, purge_point, flushing_point


classes

In the schema OpenPlant.01.07.ecschema.xml is added the C_SCREW_CAP

In the schema OpenPlant.01.07.ecschema.xml is added new classes for motors, the


DEVICE_TYPE_CODE is changed to MT.