Professional Documents
Culture Documents
Buried Pipeline
Attenuation Scanning
PIPELINE AT TENUATION SURVEY SCANNING AT THE
SPEED OF TEN MILES A DAY™
ScanTegrity
Finds Your Pipeline's Holidays, So You Don't Miss Yours™
Welcome to Tegrity.
Pipeline Scanning
On-Site Machining
Leak Repair
ScanTegrity Pipeline Attenuation
Survey Scanning Overview
ScanTegrity Pipeline
Attenuation Survey Scanning Displays the average
Accurately locates the buried Pinpoints individual wrap or
is a non-contact survey of condition of the wrap or
pipeline and displays its coating faults for excavation
buried pipelines under many coating between any two
position and depth and repair
surfaces such as roads, locations
concrete, sand, mud, and ice.
3
How It Works
The detector unit senses the presence of the electromagnetic field, radiated by the Signal Generator, that
has been applied to the pipeline. It guides the operator to the pipeline, calculates, records and displays the
strength of the remaining signal current on the line and the survey position (depth, latitude and longitude).
4
How It Works
01 02 03
The lower the rate of By comparing the average Survey intervals showing
attenuation in mB/m, the rate of attenuation of one significantly higher
better the average dielectric survey interval with another, a attenuation than a norm for
quality of the coating over the picture is built up rapidly of that diameter of pipeline are
surveyed distance. how the dielectric easily identified for additional,
performance of the coating more detailed, survey using
compares over the entire the detector in its micro
distance of target pipeline. investigatory mode.
5
Types of defects that can be found
INCORRECTLY APPLIED MECHANICAL DAMAGE DECAY OF THE DISBONDING OF THE A LEAK IN THE PIPE
EXTERNAL COATING TO THE COATING, COATING DUE TO SOIL COATING FROM THE ITSELF, CAUSING THE
BEFORE, DURING OR CONDITIONS PIPE WRAP TO FAIL AT THE
AFTER INSTALLATION LEAK POINT.
6
Limitations
7
How the ScanTegrity Pipeline Coating Scanning
Signal Generator
8
Connection by CP test post
CP test
post
CP
Earth spikes
9
Connection by TR station
Isolate TR
BEFORE
connection
Ground Bed
10
Summary of Findings
11
Coating
Classification
Criteria
12
Data Graphs
13
Conductance
Conductance, in μS (micro Siemens) per square metr, is an absolute value of the ability of the coating to
pass current. Siemens is the reciprocal of resistance and is used in preference to ohms (resistance) as
specified in NACE TM0102-02. Although C-SCAN will display μS/m², μS/m or Ω/m² if required.
ScanTegrity conforms to the “AC Current attenuation survey” as specified in NACE RP0502.
14
Line Mapping
15
THANKS FOR YOUR KIND ATTENTION
www.Tegrity.LLC
Tony.Pivo@tegrity.llc
+1-312-330-5518
16