You are on page 1of 10
17300094-001 NR Model 38100S RANGE DIAGRAM - FULLY EXTENDED OUTRIGGER CONFIGURATION - TENDED B55 FT FIXED AND RETRACTED esos 100 #7 . i ry # Zz oan = z= g Gos 00M Z wusr ae z FULLY 8 RETRACTED 9 aa WHEN JIB iS ERECTED, SEFORE LOWERING THROUGH sos = THIS AREA 6 oO 0 10 20 30 40 50 60 70 80 90 100 110 120 OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET 7300094-001 NR. 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 HEIGHT ABOVE GROUND IN FEET ALLOWABLE LINE PULL IWARNING 1 PART] 2 PART [3 PART | 4 PART | 5 PART | 6 PART une | “une |“ uiNe |“ uINE LINE, LINE. Lt L ANTI-TWO—BLOCK ‘SYSTEM MUST BE IN GoD OPERATING CONDITION. BEFORE OPERATING CRANE, TI REFER TO THE OWNER’S MANUAL. SINGLE SHEN ‘atoc KEEP_AT LEAST 3 WRAPS OF LOAD UNE-ON THE DRUM AT ALL TIMES. \sncie SHEE Le - 5/8" ROT RESISTANT 9080 | isi60 | 27240 | 36320 | 45400 | s44ao | 63560 | 72640 |/,°/8 ROT ESSN tes | iss | “Las | “Las LBs LBs iss (Bs |e Enc Sinewn F 5/8" 6 X 25 IWRC 9600 | 19000 | 28500 | 38000 | 47500 | 57000 | 66500 | 76000 [524° * 33220 is tes | iss | “uss | “iss LBs (Bs Les UBS _|{ivanenano Serene STANDARD 360" FULL CAPACITY WORK AREA AREA OF OPERATION WARNIN' THE FRONT TIRES MUST NN CONTACT WITH THE GROUND, AND THE MACHINE LEVEL, WHEN OPERATING IN THIS AREA Se DEDUCTIONS FROM RATED LOADS FOR LOAD HANDLING DEVICES SUPPLIED BY MANITOWOC BOOM TRUCKS, INC. AUXILIARY BLOCK ——————————~~-— -------- 50 LBS OVERHAUL BALL ————————~ SEE OVERHAUL BALL MANUFACTURER NAMEPLATE LOAD BLOCK ————————-— —— SEE BLOCK MANUFACTURER NAMEPLATE HOSE REEL -————————————~---- == 260 LBS SWING AROUND JIB (STOWED) -——————————~— ~~~ SEE LOAD CHART +7300094-001 NR USE THIS CHART ONLY WHEN ALL OUTRIGGERS ARE FULLY RETRACTED 85.75 REF (7'=1.75. REF) + FULLY RETRACTED OUTRIGGER CONFIGURATION - its Soe 8/ ES no 03 LSS s ee see ie A B c D 55 (Zsosrz]so m|2]6s [zz] se er zfi00 74| 76000 76 12 [60|14080| 73] 15 [53| 9110/70 20 [40] 4840/64 25 20) 2510|58) 3210/67) 3400] 72 30] | 51] 177062] 1960] 69 35 43) 780/57) 970/65 20890] 14900 9850/76 5520] 71 Trs70 1080/76) 5730] 76 70239] 5850] 79 3520] 76 2070/73 1080] 70 O40 3590 2140 1149] NO JIBS ARE TO BE ERECTED IN THIS OUTRIGGER CONFIGURATION 590 Las | 350 18S | 270 Las | 220 18s | 10 LBS FED DEDUCTIONS. FOR 890 Las | 530 Las | 400 Las | 330 Las | 260 Las TELESCOPIC STOWED JIBS 7300094-001 NR RANGE DIAGRAM - FULLY RETRACTED OUTRIGGER CONFIGURATION - ' 120 ' 80" 100 FT 75" 55) M0 p 100 a os . a ui ! mw 84 FT 90 w ' z £ z = z 5 eo 8 9 9 con wi Zz a 3 a rc 55 70 \ = 6 ° al w 52 TE | DONOT 8 A so BeasD o BOOM 8 INTO THIS so < AREA E 40" Fa 30.5 FT 40 9 rr I ao = \ 30 20" 20 10 4 10 ' \ o OO ° 0 10 20 30 40 50 60 70 OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET NOTE : LIFTING PERSONNEL WITH CRANE IN THIS OUTRIGGER CONFIGURATION IS STRICTLY PROHIBITED. USE ONLY FULLY EXTENDED OUTRIGGER CONFIGURATION WHEN LIFTING PERSONNEL. 7300094-001 NR. PINs MUST 8 ENGAGED IN THs OUTRIGGER CONFIGURATION USE THIS CHART ONLY WHEN ALL OUTRIGGERS ARE IN THE INTERMEDIATE POSITION 9° fo war wan w noes oruy extended 159.25. REF (13'=3.25 REF) - INTERMEDIATE OUTRIGGER CONFIGURATION - OuTRGGER BEANS MUST BE EXTENDED 0 / BS, FED JI TELESCOPIC JIB ee SUS Tar eone fo | ba cooe grr | ww cook Fe Re SEE Ala glenn Sessa) 8 san Ne A B c D |S 5 |S) ucts [$M] ants [3 HY ats A |sosrl 2 [52 [2 [68 Fil 2] 64 FT| 21100 FH) | -|5 8) wis |6 | wing [5 8) wating aes he)°8] mee [2] sapee | 2] Nery [68 [61000 Z[s05 AZ |305 AZ| ss 50 [64 [52860 76 | 31500 70 72 45 22| 2470] 46| 2700|57| 2820/64] 2900] 45] 71] 3180| 71) 2760 [74] 3640 50 39] 1890] 52| 2010] 60| 2090] 50 }63| 2360/69) 1930 |73| 2690, 35. '32| 1250] 48| 1370|57| 1440| 55 [66] 1700/66) 1270|71| 2020, 60 22| 720/43] 850|53| 920] 60 |64| 1170/64) 740 |6a| 1470 65, 65 ‘e7| 1020 70 70 65] _ 640 380 18S | 350 18s | 270 16s | 220 18s [160 18S FIXED DEDUCTIONS FOR 890 LBS | 530 LBS | 400 LBS | 330 LBS | 280 LBS | TELESCOPIC SSTOWED JIBS 7300094-001 NR RANGE DIAGRAM - INTERMEDIATE OUTRIGGER CONFIGURATION - EXTENDED JIB 55 FT FIXED AND RETRACTED JIB 30.5 FT 100 FT 84 FT 68 FT BOOM LENGTH IN FEET 82 FT 30.8 FT OO 0 170 80" 25 20 160 150 140 130 120 Do NoT EXTEND 110 55'BOOM OR JIB INTO THIS, 100 AREA 50" 90 45 80 70 60 50 40 30 20 10 20 30 40 50 60 70 80 90 OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET 7300094-001 NR. NOTE; LIFTING PERSONNEL WITH CRANE IN THIS OUTRIGGER CONFIGURATION IS STRICTLY PROHIBITED. USE ONLY FULLY EXTENDED OUTRIGGER CONFIGURATION WHEN LIFTING PERSONNEL. HEIGHT ABOVE GROUND IN FEET PINS MUST BE OSENGAGED FOR| OUTRGGER BEAMS “THiS. OUTRIGGER MUST Be EXTENDED CONFICURATION| =u TO MARK USE THIS CHART ONLY WHEN ALL OUTRIGGERS ARE FULLY EXTENDED MARKC INDICATES: BeAM IS FULLY ENDED 264.00 REF | (22' REF) - FULLY EXTENDED OUTRIGGER CONFIGURATION - PS eS Wn oe Fe wan Alt GutetcGens Fu EXTENDED x i | AS hen a | ere oe ne SS oe ay © £3), slag wen, gue venom), p |e uevcn Las bi |, sian). gaan, lesan Ae A B c DD [FS/RS| thls |) ets 13 8) Bhs Z [30.5] 2 [52 Fr] [68 FT] 2 [e4 FT] ZZ [00 F135 |5 f wesine |8 8) wiminc |5 8] waninc ase Mae’? [2] ware’ |? ¢| Need {6a [61000 4 [305 FL 4|305 Fé | 85 10 | 64 [52860] 76 | 31500] 70 12 | 60]+7000| 73|31500| 7831500 12 75 [53] 40280] 70 31500] 76 [31500] 7 | 23700] 15 20 [4030860] 64 [28680] 71] 26820] 76 [20600] 78] 14000] 20 76 [13500] 25; 73| 12820] 30 |77| 7300|77| 7000, 35|75[ 7100|75| 6800) 78] 4000, 40 [73] 6620/73) 6240/76] 3850, 45 [71] 6060[ 71) 5670/74] 3700 50 [6a] 5550/69) 5150) 73] 40 34 10660| 52 | 10910] 45. 22| 8440) 46| 8710|57| 8850) 50 ‘39 7060] 52| 7200] 35. '32| 8790] 48| 5930|57| 6010] 60. 22| 4760] 43| 4910|53| 4990} 5. 37 4080) 49 4160} 70 31] 3390] 45] 3479] 75. 22 2800] 40| 2890) 20. 7 [ 2280] 35] 2390] 85 30] 1960] 90, 22| 1580) 5. 11] 1230| 95 [43] 1530/43) 1120/54] 1620 100 700| 40] 1230] 40] 820/52] 1510 105 105| 36] 960]36| 550/49] 1240 110. 110} 46] _ 990 115) 115} i [43|__770 120 129] 40] 560 390 18S | 350 18S | 270 18S | 220 18S | 160 18S FIXED DEDUCTIONS FOR 890_LBS | 530 LBS | 400 LBS | 330 LBS | 280 LBS | TELESCOPIC STOWED JIBS 7300094-001 NR LMI OPERATING CODES SETTING CRANE CONFIGURATION OUTRIGGER CONFIGURATION #1——MAIN Boom —————— ---------- — FULLY EXTENDED #2 — FIXED JiB. ————————~——~~~~—~~ ~~~ Fully extenoed #3—— TELESCOPIC JIB-RETRACTED. ——————————-— — FULLY EXTENDED #4— — TELESCOPIC JIB-EXTENDED -——————~— === == FULLY EXTENDED #5—— PERSONNEL LIFTING PLATFORM ON MAIN BOOM FULLY EXTENDED #6—— PERSONNEL LIFTING PLATFORM ON FIXED JIB) ——————— — FULLY EXTENDED #7—— PERSONNEL LIFTING PLATFORM ON TELESCOPIC JIB-RETRACTED —— FULLY EXTENDED #8—— PERSONNEL LIFTING PLATFORM ON TELESCOPIC JIB-EXT FULLY EXTENDED #2——MAIN BOOM —————— INTERMEDIATE #10 — Fixed iB. ——————— INTERMEDIATE #11 — TELESCOPIC JIB-RETRACTED — INTERMEDIATE #12 — TELESCOPIC JIB-EXTENDED — INTERMEDIATE #13 — MAIN BOOM — FULLY RETRACTED WARNING 1. THE OPERATOR MUST READ AND UNDERSTAND THE OWNER'S MANUAL BEFORE OPERATING THIS CRANE. 2. POSITIONING OR OPERATION OF CRANE BEYOND AREAS SHOWN ON THIS CHART IS NOT INTENDED OR APPROVED EXCEPT WHERE SPECIFIED IN OWNER'S MANUAL. 3. LOADED BOOM ANGLES AT SPECIFIED BOOM LENGTHS GIVE ONLY AN APPROXIMATION OF THE OPERATING RADIUS. THE BOOM ANGLE BEFORE LOADING SHOULD BE GREATER TO ACCOUNT FOR DEFLECTIONS. DO NOT EXCEED THE OPERATING RADIUS FOR RATED LOADS, 4, THE OPERATING RADIUS SHOWN IN THE JIB RATING CHART IS FOR ONLY. WHEN. BOOM IS_NOT FULLY EXTENDED, USE ONLY LOADED DETERMINE LOAD RATING OF JIB. FULLY EXTENDED BOOM BOOM ANGLE TO 5, FOR BOOM ANGLES NOT SHOWN ON JIB LOAD RATING CHART, USE BOOM ANGLE, RATING OF NEXT LOWER 6. FOR BOOM LENGTHS NOT SHOWN, USE RATING OF NEXT SHORTER OR LONGER BOOM LENGTH, WHICHEVER IS LESS. FOR RADII NOT SHOWN, USE RATING OF NEXT LONGER RADIUS. 7. CRANE LOAD RATINGS ON OUTRIGGERS ARE BASED ON FREELY SUSPENDED LOADS WITH THE MACHINE LEVELED AND STANDING ON A FIRM UNIFORM SUPPORTING SURFACE. NO ATTEMPT SHALL BE MADE TO MOVE A LOAD HORIZONTALLY ON THE GROUND IN ANY DIRECTION. +7300094-001 NR WARNING (CONTINUED) 8. PRACTICAL WORKING LOADS DEPEND ON SUPPORTING SURFACE, WIND, AND OTHER FACTORS AFFECTING STABILITY SUCH AS HAZARDOUS SURROUNDINGS, EXPERIENCE OF PERSONNEL, AND PROPER HANDLING, ALL OF WHICH MUST BE TAKEN INTO ACCOUNT BY THE OPERATOR. 9, THE MAXIMUM LOAD WHICH MAY BE TELESCOPED IS LIMITED SY HYDRAULIC PRESSURE, BOOM ANGLE, AND BOOM LUBRICATION. IT IS SAFE TO ATTEMPT TO TELESCOPE ANY LOAD WITHIN THE LIMITS OF THE LOAD RATING CHART. 10. LIFTING OFF THE MAIN BOOM POINT WHILE THE SWING AROUND IB IS INTENDED OR APPROVED, INFORMATION 1. DEDUCTIONS MUST BE MADE FROM RATED LOADS FOR STOWED JIB, OPTIONAL ATTACHMENTS, HOOKS, AND LOADBLOCKS (SEE DEDUCTION CHART). WEIGHTS OF SLINGS AND ALL OTHER LOAD HANDLING DEVICES SHALL BE CONSIDERED A PART OF THE LOAD, 2. LOAD RATINGS ABOVE THE HEAVY LINE ARE STRUCTURALLY LIMITED CAPACITIES. LOAD RATINGS BELOW THE HEAVY LINE ARE STABILITY LIMITED CAPACITIES AND 00 NOT EXCE 85% OF TIPPING. DEFINITIONS 1. OPERATING RADIUS IS THE HORIZONTAL DISTANCE FROM THE AXIS OF ROTATION TO THE CENTER OF THE VERTICAL HOIST LINE OR TACKLE WITH LOAD APPLIED. 2. LOADED BOOM ANGLE AS SHOWN IN THE COLUMN HEADED 8Y &, IS THE INCLUDED. ANGLE BETWEEN THE HORIZONTAL AND LONGITUDINAL AXES OF THE BOOM BASE AFTER LIFTING RATED LOAD AT RATED RADIUS, '7300094.001 NR.

You might also like