Professional Documents
Culture Documents
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 1/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
Summary:
The purpose of this test which relates to it thermal linear stationary and transitory is to validate the Cartesian
anisotropy.
The got results are in perfect agreement with the analytical values.
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 2/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
1 Problem of reference
1.1 Geometry
Z0 J
I
Y0
K
E B
H Z1
X1 D
Y1
G X0
F A
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 4/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
2 Reference solution
2.1 Method of calculating used for the reference solution
Analytical solution.
Temperature varying linearly according to CD
[ ][ ]
∂T
− X cos 2 Y sin2
x ∂x
y = ∂T
− X − Y cos sin
z ∂x
0
with:
− x
x =1200 y =400 = X 1, CD T x= xT A
X cos 2 Y sin2
1
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 5/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
3 Modeling A
3.1 Characteristics of modeling
diagram in time, forced on 1 to test the calculation of the second member.
4 elements 3D, HEXA8.
*: imposed temperature
3.4 Remarks
The analytical solution being of order 1 and the field represented by the discretization, the code finds,
with the errors rounding close, this solution.
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 6/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
4 Modeling B
4.1 Characteristics of modeling
Similar to the modeling A, but solved in 2D in the plan CDEF .
*: imposed temperature
4.4 Remarks
The analytical solution being of order 1 and the field represented by the discretization, the code finds,
with the errors rounding close, this solution.
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)
Version
Code_Aster default
Titre : TPLL100 - Mur plan anisotrope en thermique station[...] Date : 12/12/2011 Page : 7/7
Responsable : HAELEWYN Jessica Clé : V4.02.100 Révision :
42178466ba30
Warning : The translation process used on this website is a "Machine Translation". It may be imprecise and inaccurate in whole or in part and is
provided as a convenience.
Copyright 2020 EDF R&D - Licensed under the terms of the GNU FDL (http://www.gnu.org/copyleft/fdl.html)