Professional Documents
Culture Documents
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 1
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, presenting flexible technical + commercial solutions and supplying a loan
unit during warranty repair, if available.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based at Aldermaston in the UK from where we supply test equipment worldwide.
Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab.
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our 40GHz in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
CA6472-6474_CONTROL TERRE_GB 24/10/07 15:09 Page 2
C.A 6472
C.A 6474
HIGH PERFORMANCE
• Possibility of analysing the frequency behaviour
of earthing systems (41 Hz to 5 kHz)
• Wide measurement range for optimum resolution
• Rejection of interference voltages up to 60 Vpeak
AthanA • 906211158 - Ed.1 - 09/2007 - Non contractual document. Confirm specifications before ordering.
3P EARTH MEASUREMENT
4P MEASUREMENT
METHOD METHOD
Do not connect
the black cable
if using the
The 3P method is the traditional method using rods to
3P method measure the resistance of an existing earth connection.
The C.A 6472 can also be used to measure the
resistances of the auxiliary rods RS and RH, as well as
any interference voltages, thus allowing more accurate
interpretation of the measurement.
Suitable for all types of measurement environments,
even the most difficult, it guarantees measurement of
auxiliary rod resistances up to 100 kø and interference
voltages up to 60 Vpeak.
ES
In the event of a system with parallel earth connections, the C.A 6472 E
RE
is capable of accurately measuring an earth resistance using clamps C.A 6472
only. The principle of this method involves placing 2 clamps around the
earth conductor to be tested and connecting them each to the instrument. One clamp injects a known signal ( 32 V /
1367 Hz) while the other clamp measures the current circulating in the loop.
This method saves considerable time when earth testing because it is no longer necessary to set up auxiliary rods or to
disconnect the earth connections.
GROUND RESISTIVITY
MEASUREMENT
Wenner method:
When it is possible to choose the
the distances between position of the earth connection,
the 4 rods are identical: resistivity measurement helps to
d ρW = 2.π.d.RS-SE
assess the ground and thus
determine the place where the
earth resistance will be lowest
(optimization of construction costs).
The C.A 6472 automatically calculates
Schlumberger method: the resistivity of the ground (ρ) using
the distance between
the 2 central rods S & ES the Wenner or Schlumberger
is A method, as soon as the distances used
the distance between between the rods have been entered.
the 2 outside rods E & H
is 2d The resistances of the rods RE, RES, RS
ρS = (π.(d2-A2/4).RS-SE) /4 and RH can also be measured.
ES
E
This measurement can be used to determine the value of the C.A 6472
Reference 3
potential 4
C.A 6474
ELECTRICAL SPECIFICATIONS
4P / 4P Earth measurement Earth potential DC resistance Measurements
3P method Resistivity
selective method with 2 clamps measurement measurement with C.A 6474
Range 0.01 Ω to 99.9 kΩ 0.001 Ω to 99.99 Ω 0.01 Ω to 500 Ω 0.01 kΩ to 99.9 kΩ 0.01 mV to 65.00 V 0.001 Ω to 99.9 kΩ 0.001 Ω to 99.99 kΩ
2 wires: 0.01 Ω
to 100 Ω/
Resolution 0.01 to 100 Ω 0.001 to 10 Ω 0.01 to 1 Ω 0.01 to 100 Ω 0.01 mV to 10 mV 0.001 to 10 Ω
4 wires: 0.001 Ω
to 10 Ω
Accuracy ± (2% + 1 count) ± (2% + 1 count) ± (10% + 1 count) ± (2% + 1 count) ± (5% + 1 count) ± (2% + 2 counts) ± (5% + 1count)
No-load voltage 16 or 32Vrms 16 or 32 Vrms 16 or 32 Vrms 16 or 32Vrms 16 or 32 Vrms ±16 VDC 16 or 32 Vrms
Auto: 1,367 Hz
Measurement frequency 41 to 5,078 Hz 41 to 5,078 Hz Manual: 1,367 Hz, 41 to 128 Hz 41 to 128 Hz DC 41 to 5078 Hz
1,611 Hz, 1,758 Hz
Coupling measurement yes – – – – – –
MECHANICAL SPECIFICATIONS
Protection rating IP 53
Electrical safety CAT IV 50 V, complies with IEC 61326-1 / IEC 61010 / IEC 61557-1-4-5
AthanA • 906211158 - Ed.1 - 09/2007 - Non contractual document. Confirm specifications before ordering.
STATE OF DELIVERY • C.A 6474 adapter for pylon earth
measurement (PYLON BOX) .......................... P01.1265.10
Delivered with a carrying bag for accessories
• C.A 6472 earth and containing: One C.A 6472 – C.A 6474
resistivity tester .............................. P01.1265.04 connection lead, 6 BNC / BNC cables 15 m
Delivered with: mains adapter + 2-pole mains cable for recharging long, 4 AmpFLEX flexible current sensors
the battery from the mains supply, one operating manual in 5 languages 5 m long, 1 set of 12 AmpFLEX identification
on CD-ROM, 5 simplified operating manuals and 5 specific labels, rings, 2 cables (5 m green, 5 m black) with
each in a different language. safety connectors on winder, 5 spade
Data export software + USB/optical communication cable lug/banana plug converters Ø 4 mm, 3
and two C182 clamps clamps, 1 calibration loop, 5 operating
manuals and 5 specific labels, each in a
different language.
ACCESSORIES
• 100 m earth and resistivity kit .................... P01.1020.24
• 150 m earth and resistivity kit ................... P01.1020.25
• C.A 647X continuity kit (mΩ position) ............ P01.1020.37
• MN82 CLAMP (Ø 20 mm) for C.A 6474 ........ P01.1204.52
• Adapter for battery charging
on cigarette lighter .................................... P01.1020.36
• DataView® PC software............................... P01.1020.06
• Optical / RS232 communication cable........... P01.2952.52