Journal of Composites
Volume 2013, Article ID 403656, 9 pages
http://dx.doi.org/10.1155/2013/403656
Research Article
Carbon/Phenolic Nanocomposites as Advanced Thermal
Protection Material in Aerospace Applications
Copyright © 2013 J. S. Tate et al. This is an open access article distributed under the Creative Commons Attribution License, which
permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Ablative nanocomposites were prepared by incorporating multiwall carbon nanotubes (MWCNT) into phenolic resin and then
impregnating them into rayon-based carbon fabric. MWCNT were blended into phenolic resin at 0.5, 1, and 2 wt% loadings using
a combination of sonication and high shear mixing to insure uniform dispersion of MWCNT. The composite test specimens were
tested by using an oxyacetylene test bed (OTB) applying a heat flux of 1000 W/cm2 for duration of 45 seconds. Composite specimens
with 2 wt% MWCNT showed reduction in mass loss, recession in length, and in situ temperatures compared to control composites.
1. Introduction et al. [2], used MX-4926 material as the baseline for the
development of polymer nanocomposite ablative materials in
Ablation is a process of material removal from a surface or their research.
other erosive process and usually associated with materials Ablative materials have progressed with the introduction
for space reentry vehicles and rocket nozzles. The ablative of new materials and technologies. Since the late 1990s,
materials are used as thermal protection materials for rocket nanotechnology has been a new frontier of the scientific
nozzles, space vehicles, and combustion chambers of rocket community. Nanotechnology deals with particles which have
motors. These materials should withstand very high tempera- at least one dimension on the nanometer scale [2]. Nanopar-
tures in the order of thousands of degrees Celsius, high thrust, ticles are materials which are in the purest form that have
and high impact. The final material should be able to form exceptional fundamental properties. Their high surface-area-
complex shapes and be as light as possible. Currently the to-volume ratio, especially for nanotubes, makes them perfect
main consumers of ablative materials are military, NASA, and ablative and reinforcement materials. Addition of proper
commercial space launching company. nanoparticles in polymer matrix can enhance ablative and
Intensive research on ablative materials began during the overall mechanical properties of polymer matrix composites.
space race between the USSR and the USA in 1950s. Some Therefore, many articles and reports have been published
of these research materials were made by universities, while on effects of nanoparticles on ablative properties [1–7].
some by private companies, such as Cytec Industries. The The typical nanoparticles used for ablatives are single and
most popular material used in the United States, which is multiwall carbon nanotubes (SWCNT, MWCNT), carbon
the standard material for NASA and other organizations, black, and nanoclays. Nanoparticles vary not only in mechan-
is MX-4926 manufactured by Cytec Engineered Materials. ical and physical properties but also by price, availability,
MX-4926 is a composite material composed of woven rayon- processability, and safety. The following paragraph reviews
based carbon fiber, carbon black filler, and a phenolic resin the literature discussing the effects of polymer nanocompos-
matrix. Many research groups, such as Ho et al. [1] and Patton ites on ablation properties. These nanoparticles in polymer
2 Journal of Composites
35 1.4
20
0.8
15
0.6
10
5 0.4
0 0.2
0 0.5 1 1.5 2 2.5
MWCNT’s (wt%) 0
0 0.5 1 1.5 2 2.5
MWCNT’s (wt%)
MWCNT’s (wt%)
0 1
0.5 2 MWCNT’s (wt%)
0 1
Figure 3: Decrease in percentage mass loss with increase in 0.5 2
MWCNT wt%.
Figure 4: Decrease in recession with increase in MWCNT wt%.
The fabric had a weight of 261 g/m2 , specific gravity of 1.84, 900
and thickness of 0.48 mm. Break strength was 0.496 MPa
800
and 0.599 MPa in the warp and fill directions, respectively.
It had 1.96 picks/mm in warp direction and 2 picks/mm fill 700
direction. The 8-harness satin weave provided conformability
essential for producing complex geometries. 600
Temperature (∘ C)
500
2.2. SC-1008 Phenolic Resin. The matrix used in this research
was SC-1008 phenolic resin which was manufactured accord- 400
ing to MIL-R-9299 and supplied by Momentive (formerly 300
Hexion Specialty Chemicals). The viscosity was in the range
of 180–300 cP depending on storage conditions. SC-1008 200
contained roughly 20%–25% isopropyl alcohol (IPA) as a
solvent. This is a phenolic-laminating varnish specifically 100
designed for applications where components are exposed up
0
to 260∘ C for extended duration of time. 0 0.5 1 2
MWCNT’s (wt%)
2.3. Nanomodification. Nanomodification in ablative com- Thermocouple (1) 5 mm from flame front
posites was achieved by incorporating Graphistrength
Thermocouple (2) 10 mm from flame front
MWCNT supplied by Arkema, Inc. They had a typical
diameter of 10–15 nm and length between 1–10 𝜇m. MWCNT Figure 5: Peak in-situ temperatures at 5 mm and 10 mm depths from
have tendency to agglomerate at dimensions of 50–900 𝜇m. flame front surface.
4 Journal of Composites
Top surface (images taken on this at 40 Hz which provided shear rate of 77,000 s−1 . A water
surface near and at certain cooling system was used to avoid overheating of the mixer
distances from flame front surface)
6.25 mm and resin. The temperatures of the resin and mixing chamber
were maintained below 50∘ C. Three different loadings of
12.7 mm
Flame front surface MWCNT were introduced in the phenolic resin: 0.5, 1, and
(images taken at 90 ∘ and at
2 wt%. After high shear mixing, the resultant mixture was
certain tilts to this surface)
kept in a vacuum oven for 24 hours at 80∘ C, so that excess IPA
12.7 mm that was used for dispersion of MWCNT using sonication,
got evaporated. It was observed that the viscosity increased
Figure 6: SEM Images on specimens after ablation testing. very rapidly as the wt% loading of MWCNT increased.
Highly viscous resin imposes tremendous challenges in
making prepregs using even hand lay-up technique. Carbon
fabric must be completely soaked in the resin in order to
Due to this agglomeration tendency, uniform dispersion of
maintain desired fiber volume percentage and density of the
MWCNT was a very challenging task.
composite. Therefore, MWCNT loading was not increased
beyond 2 wt%.
2.4. Dispersion of MWCNT into Phenolic Resin. In the pre-
vious studies by the same research team, 1 wt% MWCNT
was dispersed into phenolic resin by using three different 2.5. Molding Compound Preparation. The second step of the
techniques: sonication (SN), high shear mixing (HS), and manufacturing process was the production of prepregs using
combination of sonication and high shear mixing (SNHS). To hand lay-up technique. Carbon fabric and resin were taken
analyze the effect of dispersion of MWCNT in phenolic resin in proportion to achieve desired fiber volume fraction and
with respect to these different mixing techniques thermo- density. Desired fiber volume fraction was 50% by volume.
gravimetric analysis (TGA) was performed on all the samples. Carbon fabric was soaked with nanomodified phenolic resin
Characterization was carried out according to ASTM E 2550, using hand rollers. Prepregs were weighed after impregnation
the test method for thermal stability, and ASTM E 1131, the and then placed into a preheated oven at 100∘ C for 30 minutes
test method for compositional analysis. Samples were taken to achieve B-staging. The prepregs were again weighed in
from a fractured surface of the phenolic coupons and had order to evaluate mass loss. To prevent premature curing of
weights of 11.6–21.8 mg. All samples were placed in aluminum the material, prepregs were stored into the freezer. Further
pans and heating was carried at a heating rate of 20∘ C/min, these prepregs were manually cut into 12 mm by 12 mm
using argon as a purge gas at the rate of 100 mL/min. All squares using a cutting board.
samples were heated to a peak temperature of 800∘ C. Use
of inert atmosphere in TGA analysis is the key as MWCNT 2.6. Compression Molding. Ablative test panels were pro-
would oxidize in open air above temperatures 650∘ C. duced by compression molding using a Wabash Automatic
TGA showed that the majority of the mass loss for Hydraulic Compression Press. Two-part compression mold
SN and HS samples was in the range of 200∘ C to 500∘ C, with cavity of 120 × 120 × 12.7 mm (4.75 × 4.75 × 0.5 inch)
while this range was 300∘ C to 550∘ C for SNHS samples. was used for compression molding. The mold was made up
SNHS samples also showed better thermal stability for higher of high alloy steel to withstand the high compressive forces.
temperatures above 550∘ C as compared to other samples. Appropriate mold release agent was used for smooth removal
Figure 1 shows TGA results for 1 wt% of MWCNT samples for of panel after compression. The mold and the platens of the
all mixing methods. The plot clearly indicates that thermal compression press were preheated to 163∘ C. Small square
stability of SNHS samples was better than the SN and HS pieces of prepregs were placed in the mold cavity, and then the
samples. The higher temperature range for mass loss in SNHS mold was placed between the platens of compression press.
samples is attributed to the increased dispersion of MWCNTs Initially 45 kN (5 US ton) force was applied for five minutes
in the SC-1008 resin [17]. It can be inferred from TGA and then mold was released. Then 134 kN (15 US ton) force
that the combination of sonication and high shear mixing was applied for 10 minutes. Finally, 267 kN (30 US ton) force
(SNHS) processing technique provided uniform dispersion was applied for two hours at 163∘ C which provided pressure
of MWCNT. Therefore, this technique was chosen to blend of 18.54 MPa (2689 psi). Air and water cooling cycles were
MWCNT into the phenolic resin. five minutes and 10 minutes, respectively. Specific gravity of
Sonication was used to disperse MWCNT in IPA. Since ablative panel was measured. The target specific gravity was
SC-1008 contained IPA as the solvent, its usage as a disper- 1.46—the same as that of MX-4926. Density is one of the key
sion medium was ideal. The amplitude of sonication varied properties of the ablative materials.
between 25%–45% to compensate for subsequent increase
in viscosity. The power of the sonicator was kept below
40 watts to avoid damaging the MWCNT and to prevent 2.7. Preparation of Ablative Test Specimens. Ablative test
rapid build up of heat. Mixing could only proceed for two specimens of size 12.7 mm × 12.7 mm × 12.7 mm cube were cut
minutes before viscosity of the mixture increased, resulting in using a tile saw. Six specimens were cut in each category. Two
cessation of sonication. Then the resulted mixture was mixed holes of diameter 1.5 mm were made at depths 2.7 mm and
with phenolic resin in a high shear mixer for 15 minutes 7.7 mm from the rear surface to place thermocouples during
Journal of Composites 5
Top surface (20 𝜇m) Top surface, 2 mm away Flame front (40 𝜇m)
from flame front (10 𝜇m)
testing. The distance between the holes was 2.5 mm as shown specimens were measured before and after the ablation test
in Figure 2. in order to measure the percentage mass loss and recession in
length. Peak temperature at depths 2.7 mm and 7.7 mm from
2.8. Testing of Ablative Specimens on Oxyacetylene Test Bed. the rear face (which is 10 mm and 5 mm from flame front
The oxyacetylene test bed (OTB) is a small scale ablation face) was obtained from the data acquisition system using
testing device at the University of Texas at Austin, that is, thermocouples. Figure 2 shows the layout thermocouples on
ablative test specimens.
capable of producing a heat flux of 1450 W/cm2 and flame
temperature up to 3000∘ C using a calibrated oxyacetylene
welding torch. Similar types of devices have been developed 2.9. Postablation Scanning Electron Microscopy Characteri-
at Sapienza University of Rome [18] and University of Perugia zation. Scanning electron microscopy (SEM) analysis was
[19]. This type of experimental setup is used for testing performed on all test specimens after ablation testing. High
different ablative materials at relatively low costs while still resolution SEM images were obtained at different orienta-
simulating extreme conditions in real world applications. It tions of the char microstructures in order to understand the
is suitable for comparing the relative performance of ablative effects of ablative testing on materials. SEM images were
materials to one another [20, 21]. taken using Leo SRV-32 scanning electron microscope, under
OTB setup contains a data acquisition system to measure an argon gas atmosphere at different magnifications.
the in situ temperature of the test specimens using embedded
thermocouples. The distance of the torch nozzle from the test 3. Results and Discussions
specimen was used to calibrate the heat flux output of the
OTB. A slug calorimeter was used to calculate these values in 3.1. Ablation Test Results. Ablative test specimens were
which a copper slug of known mass was exposed to the torch, exposed to a heat flux of 1000 W/cm2 for approximately
and the power into the slug was derived from the measured 45 seconds. Results of percentage mass loss, recession, and
time versus temperature curve of the slug [20, 21]. peak in-situ temperatures presented herein are averages of six
For this experiment, all materials were tested for duration identical specimens tested in each category.
of 45 seconds at a distance of 6 mm and applying approx-
imately heat flux of 1000 W/cm2 . Six identical specimens 3.1.1. Percentage Mass Loss. All ablative samples were
were tested in each category. Masses and lengths of all test weighed before and after the ablation testing in order to
6 Journal of Composites
Flame front at with 45∘ tilt (5 𝜇m) Top surface (5 𝜇m) Top surface (5 𝜇m)
measure mass loss. It was observed that percentage mass Table 1: Average percentage mass loss after ablation testing.
loss for the ablative test specimens decreased with increasing
MWCNT weight percentage. Results for percentage mass MWCNT wt% Percentage mass loss (%)
loss are shown in Table 1, and the decreasing trend of 0 26 (3.2)
percentage mass loss is shown in Figure 3. All nanomodified 0.5 25.5 (2.91)
test specimens showed better performance than control 1 25 (3.09)
specimens. For control specimen, the percentage mass loss 2 23 (1.9)
was 26%, whereas it was 23% for composites containing 2 wt% Note: values in brackets indicate standard deviation.
of MWCNT. When a heat flux was applied on the specimens,
initial heat transfer was by pure conduction and resulted in
a temperature rise that caused material expansion. When 3.1.2. Recession. The thickness of each specimen measured
the material reached a certain temperature, the pyrolysis before and after the test was used to determine average reces-
reaction or thermochemical degradation occurred and sion. The thickness of samples measured after the ablation
produced decomposed gases and solid carbonaceous char test was only thickness of virgin material, excluding char
residues [16]. In the nanocomposites, the nanoparticles thickness. Recessions for nanocomposites were decreased
formed highly viscous melt layer as soon as the pyrolysis with increasing MWCNT wt%. Results for the recession
reaction started, and it covered the formed char residue are shown in Table 2 and decreasing trend of recession is
which acted as an antioxidizing agent and a thermal shown in Figure 4. The recession of the control compos-
protective barrier forming a carbon-based network. This ite specimen was 0.83 mm, whereas it was 0.38 mm for
melt layer also continued endothermic reaction and reduced nanocomposites containing 2 wt% MWCNT. All nanocom-
pyrolysis rate, resulting in less erosion of material [15]. posite specimens showed better performance than control
In the case of MWCNT, their presence in char residue material. The analysis of percentage mass loss and recession
reemits large amount of incident radiation into gas phase, provided information about amount of material eroded or
which decreased heat transferred to inner virgin material amount of material transformed into char. The decrease in
and reduced pyrolysis rate [1, 21]. Hence, the addition of percentage mass loss and recession are outcomes of improved
MWCNT resulted in decrease in percentage mass loss. thermal stability and the formation of a carbon network
Journal of Composites 7
Flame front (5 𝜇m) Flame front at 45∘ tilt (5 𝜇m) Top surface, 1 mm away
from flame front (10 𝜇m)
Table 2: Average recession after ablation testing. some heat which would have been conducted in the rest of
the test specimen.
MWCNT wt% Recession (mm) Figure 5 displays the average peak in-situ temperature
0 0.83 (0.51) decreased with increase in the wt% of MWCNT. Peak in-
0.5 0.59 (0.35) situ temperature obtained from both the thermocouples at
1 0.42 (0.37) two different depths decreased with the increase in wt% of
2 0.38 (0.12) MWCNT. The average peak temperature obtained by thermo-
Note: values in brackets indicate standard deviation. couple T2 at 5 mm from the flame front was 700∘ C for control
test specimen, while it was significantly reduced to 284∘ C
for nanocomposite containing 2 wt% of MWCNT. Similarly,
char achieved by addition of MWCNT. In control specimen, the average peak temperature obtained by thermocouple
the absence of nanofillers led to continuation of pyrolysis T1 at 10 mm from flame front was 272∘ C for control test
reaction. This pyrolysis resulted in more erosion of material specimen, while it was reduced to 239∘ C for nanocomposite
causing increased recession. specimens containing 2 wt% of MWCNT. Figure 5 shows the
decreasing trend of peak temperatures with increase in the
3.1.3. Peak In-Situ Temperature. During ablation testing, two wt% of MWCNT. There was little irregularity in the in-situ
K-type thermocouples, T1 and T2, were placed inside the temperature decreasing trend for nanocomposite specimens
specimens at depths of 2.7 mm and 7.7 mm from the rear face, containing 0.5 wt% MWCNT at 10 mm from flame front.
respectively. Figure 2 shows the layout of thermocouples. The average peak in-situ temperature was a little higher at
These thermocouples were connected to the data acquisition 279∘ C compared to 272∘ C for the control test specimen. The
system that provided temperature and time data during decreasing trends in the peak in-situ temperatures at both
ablation testing. There are many factors that can affect the the depths were caused by the addition of MWCNT which
in-situ temperature in the specimens. Thermal conductivity led to high thermal stability and enhanced char formation
of the material, char formed during testing, thickness of the of nanocomposite materials [22]. One of the reasons of
virgin material, and char thickness affect the heat flow in the increased thermal stability was due to enhanced carbon char
material [20]. Additionally, the eroded material also carried formation and reradiation of MWCNT in phenolics. It is also
8 Journal of Composites
Flame front (5 𝜇m) Flame front (5 𝜇m) Flame front at 36∘ tilt (5 𝜇m)
Journal of
Metallurgy
BioMed
Research International
Hindawi Publishing Corporation Hindawi Publishing Corporation
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014
Nanomaterials
Submit your manuscripts at
http://www.hindawi.com
Journal of Journal of
Materials
Hindawi Publishing Corporation
Nanoparticles
Hindawi Publishing Corporation
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014
Nanomaterials
Journal of
Nanoscience
Hindawi Publishing Corporation
Coatings
Hindawi Publishing Corporation
Crystallography
Hindawi Publishing Corporation
Ceramics
Hindawi Publishing Corporation
Textiles
Hindawi Publishing Corporation
http://www.hindawi.com
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 Volume 2014