Notes :-

~ ~ ~ ~
ALL DIMENSIONS AND LVLS ARE IN MM, UNLESS NOTED OTHER WISE. (U.N.O.)

A B C D D' E DO NOT SCALE ANY DRG. FOLLOW WRITTEN DIMENSIONS ONLY.


THIS DRG. SHOULD BE READ IN CONJUNCTION WITH RELEVANT ARCH. AND
RCC COLUMN RCC COLUMN SERVICE DRGS. ANY DISCREPANCY SHOULD BE BROUGHT TO THE NOTICE
OF CONSULTANT IMMEDIATELY.
6730 1570 5185 1686 6544 COL R/F COL R/F

21715 DISCLAIMER:-

BASEMENT F.F. LVL. BASEMENT F.F. LVL. THE PURPOSE OF THESE DRAWINGS AND INFORMATION CONTAINED

230
-3750 (AS/ARCH) -3750 (AS/ARCH) THEREIN IS TO ERECT, CONSTRUCT AND RESURRECT A STRUCTURE
2200 AND STRUCTURAL SYSTEM TO PERFORM IN A SATISFACTORY AND
ACCEPTABLE MANNER AS PER THE INFORMATION PROVIDED TO THE

01 T1 T2 T1
ORGANISATION FOR THE REQUIRED PURPOSE AND PERFORMANCE OF

1200
T2 THE STRUCTURE.

I
I I 10@200c/c II 10@200c/c

I
O II 10@200c/c
O O THE LOADS STRUCTURAL SYSTEM AND MATERIAL TO BE USED FOR

AS/SCHEDULE.

150

150
300 BOTHWAYS BOTHWAYS 300 300 BOTHWAYS CONSTRUCTION HAS BEEN ASSESSED VERIFIED AND ANALYSIS AND

D
300 300 300

F2 DESIGN HAS BEEN DONE THERE ON TO PROVIDE THESE INFORMATION

~~

~~

~~
700

150
1300
IN DRAWING FORM FOR THE ABOVE SAID PURPOSE
F3

3815
1515

400
CF1

I
B1 I I 10@200c/c
O B1
300

WATER PROOFING

100
F4

I
500(TYP.)
300 300

I
1610 1564 P.C.C.(1:4:8)
B2
WATER PROOFING
AS/ SPECS. I 10@200c/c
O
BOTHWAYS 500(TYP.) P.C.C.(1:4:8) 300 B2 300 500(TYP.) I 10@200c/c
O AS/ SPECS. THE OWNER OF THE PROPERTY AND DEVELOPER ALONG WITH THE

I
BOTHWAYS SIZE(AxB) BOTHWAYS SUPERVISING ENGINEER NEED TO VERIFY THE SAFETY OF ENTIRE
SIZE(AxB)
CONSTRUCTION SEQUENCE ALONG WITH VARIOUS STAGES OF
Y
1300 X CONSTRUCTION TO ENSURE CORRECT AND SAFE ERECTION OF

1425
STRUCTURE. THE STRUCTURAL DRAWINGS SHOULD BE CORRECTLY
230
L L ACCESSED FOR STRUCTURAL PERFORMANCE, ADEQUACY OF DESIGN
AND VERIFIED BY A COMPETENT AND AUTHORISED AUTHORITY BEFORE

02 CONSTRUCTION, PLANNING AN ACTUAL IMPLEMENTATION AT

800
CONSTRUCTION SITE.

1140

T1
COLUMN SHIFTED IN ARCH. DRG

T1
ALL RELEVANT TESTING OF CONSTRUCTION MATERIAL AS PER B.I.S
F7 CODES (IS8112:1989,IS12289:1987, IS516:1959, IS269:1989, IS383:1970,
F6

2635
275 T2
IS650:1991, IS23386 - ALL PARTS) MUST BE DONE AT THE VARIOUS

1665 1325 T2 STAGES OF CONSTRUCTION, MATERIAL PROCUREMENT AND PURCHASE.


875 ALL RELEVANT TESTING OF AS BUILT STRUCTURE AND VARIOUS OTHER
TEST PERTAINING TO CONCRETE PRODUCED AND INSTALLED IN THE

745

745
STRUCTURE AND OTHER AFTER CONSTRUCTION MATERIAL ADEQUACY

03 Y
AND ITS PERFORMANCE FOR THE PURPOSE ITS BUILD, REMAINS AS THE
SOCIAL AND LEGAL RESPONSIBILITY OF THE PROPERTY OWNERS AND

945
X PROPERTY DEVELOPING AGENCY.
B

B
ANY NON-SATISFACTORY PERFORMANCE OF THE CONSTRUCTED
04

B
F10 BUILDING AND STRUCTURE, AFTER AND AS WELL AS DURING
CONSTRUCTION, WILL HAVE TO BE FURNISHED BEFORE A COMPETENT

415
ARBITRATOR (IIT'S AND OTHER VERIFY AGENCIES) ALONG WITH
VARIOUS COLLECTED TEST DATA AND MATERIAL DURING AND AFTER
CONSTRUCTION MANDATORY TESTS BEFORE VERIFYING AND

F8 F9 CF2 CHALLENGING ON ANALYSIS, DESIGN & DRAWINGS AS OFFERED AS

B1
3837
INFORMATION TO BE USED IN CONSTRUCTION.

B1
B2
B2
1200

21715
A 1200 150
05

1188

1427
TYPICAL ISOLATED FOOTING PLAN
SIDE FOOTING PLAN
230 F6

3323
900
1425
GROUND FL. FINISH LVL.

1446
+450 LVL.(AS/ARCH)
06

540
230 350
07 D6 (TYP.)

1375

1400

1725
8000
F11 F12

FOOTING CAN NOT POSSIBLE IN PUMP 1050 590 F13 DOM. TANK
1150 x 2000
1725
10000 LTRS.
LVL. -4650
F8
±00 PAVER
(AS/ARCH)
1

ROOM SO DO ONE SIDES OR CLEAR FROM

I
I 10@200c/c
6620

PUMP ROOM O PURPOSE OF DRAWING

5930

I
1500 6100 x 5930 FIRE TANK GOOD FOR CONSTRUCTION (G.F.C.) FOR APPROVAL ONLY (F.A.O.)

1301
1864 200000 LTRS.
PUMP ROOM F3 515 lvl. -4950
lvl. -4650 FOR INFORMATION ONLY (F.I.O.) FOR SUBMISSION ONLY (F.S.O.)

1500

1300
F14

1000

1000
F14
FOR TENDER PURPOSE (F.T.P.) FOR SCHEMATIC PURPOSE (F.S.P.)

I
F4 I 10@200c/c
O
FOR PROOF CHECKING (F.P.C.) FOR ADVANCE COPY (F.A.C.)

EACH FACE
I

II 8@200c/c
08

2
FOUNDATION PLAN DATE REV DESCRIPTION DATE ISSUED AT NOS.

REVISIONS DISTRIBUTION
I

O
THIS DRAWING IS THE PROPERTY OF SUDHA TECHNICAL CONSULTANTS
FOOTING SCHEDULE: R.C.C. WORK AND NOT TO BE COPIED OR HANDED OVER TO A PARTY OR USED

PUMP ROOM AREA FOOTING SHOULD BE IN MARK


FOOTING SIZE
L B
THK.
T ALONG L
BOTTOM R/F
ALONG B ALONG L
TOP R/F
ALONG B
COMPACTED
FILL AS/SPECS
FOR ANY PURPOSE OTHER THAN FOR WHICH IT HAS BEEN ISSUED

CONSULTANTS
SUDHA TECHNICAL CONSULTANTS
CF1 2200 4730 600 #12@100c/c #12@100c/c #12@200c/c #12@200c/c

PUMP ROOM F2 3400 1600 500 #12@100c/c #12@100c/c _ _


F-702 upper ground floor,lado sarai new
Delhi-110030 India.
E-mail:-mail@stcplt.com

I
F3 3350 1900 600 #12@100c/c #12@100c/c _ _
I 12@200c/c
O E-mail:- stcplt@gmail.com

I
STCPL
F4 2500 2500 500 #12@100c/c #12@100c/c
_ _
STOPS Telephone-011-46140128,011-46120358,

_ _ BASEMENT FINISH LVL. ARCHITECTS


F6 2850 2850 600 #12@100c/c #12@100c/c
(B)

I
_ _
II12@200c/c
O
F7 2650 2650 500 #12@125c/c #12@125c/c
+ -3750 LVL.(AS/ARCH)

I
F8 2075 3600 500 #12@100c/c #12@100c/c _ _
(B) OI 10@200c/c www.vga.co.in
(A)

I
603, CHIRANJIV TOWER 43, NEHRU PLACE, NEW DELHI-110019
F9 3550 3550 750 #16@150c/c #16@150c/c _ _ T 91 1126414763, 26410790, 46509432-34 F 91 11 26294062

1200
F10 1475 2500 400 _ _ CLIENT:
#12@100c/c #12@150c/c
_ _

AS/ARCH
F11 2250 4050 500 #12@100c/c #12@100c/c

FILLING
IN FIRE TANK PLZ. TAKE THK. BASE SLAB NO _ _ ~ ~ ~~ ~ ~
I 10@200c/c

I
F12 4100 4100 800 #16@100c/c #16@100c/c O

I
F13 3450 3450 750 _ _ BASEMENT F.F. LVL.
PROJECT TITLE
#16@150c/c #16@150c/c -3750 (AS/ARCH)

I
_ _ I 10@300c/c
O

FILLING TO BE DONE BELOW TANK F14 3950 2200 600 #16@150c/c #16@150c/c PROPOSED COMMERCIAL COMPLEX AT PLOT NO

I
CF2 7010 3355 700 #12@100c/c #12@100c/c #12@100c/c #12@100c/c I 10@200c/c
O A-1/1 NANIWALA BAGH AZADPUR DELHI.

I
COL R/F COL R/F
300 BOTH WAYS
(TYP.)

350
SAND
AS/ARCH
LIFT PIT LIFT PIT DRAWING TITLE
NOTES:-

~150 ~
SAND
ALL R.C.C. WORK SHALL BE DONE AS PER IS : 456-2000 .
STCPL

1 GRADE OF CONCRETE FOUNDATION PLAN & DETAIL


T2 T1 FOR COLUMN TO BE = M:30

100
FOR RAFT TO BE = M:25
2 GRADE OF REINFORCEMENT = Fe500(HYSD)
(OF TESTED & APPROVED QUALITY) SCALE :
APPROVED :
500(TYP.)
AS/SCHEDULE.

3 COVER TO THE MAIN REINFORCEMENT SHALL BE AS FOLLOW :-

I
I 10@200c/c
O
D

I
P.C.C.(1:4:8) I 10@100c/c
O BOTTOM TOP SIDE
CHECKED : PRAVEEN 1:100

I
------- -------- 40MM

I
IN COLUMN

230 970
BOTH WAYS IN PILE
IN PILE CAP
75MM
60MM
-------- 60MM
DESIGN : ARUSHI SHARMA REV. NO. :
300 300

B1 300 300
300 300

60MM 60MM
300 B2 300 300 300 300 300
P.C.C.(1:4:8) 4 DEVELOPMENT LENGTH FOR REINFORCEMENT (FOR Fe500) TOR STEEL
SIZE(AxB) 1200 DRAWN : S.PANCHAL
MIX OF CONC. BAR IN TENSION & BENDING BAR IN COMPRESSION
B A M 30 46 X d 46 X d
PROJECT :PRPOSED COMMERCIAL COMPLEX AZADPUR DRG. NO. :

M 25 49 X d 49 X d
FILE :
5 REFER THIS DRG. IN CORRELATION TO FOLLOWING
S-01-02
STRUCTURAL DRGS :S-01-01,S-1-03 DATE : 11th JUNE.2020