You are on page 1of 108

Installation Manual

DUAL-FREQUENCY SEARCHLIGHT SONAR


Model CH-300

SAFETY INSTRUCTIONS .............................................................................................................i


SYSTEM CONFIGURATION .......................................................................................................iii
EQUIPMENT LISTS.....................................................................................................................iv

1. MOUNTING ...........................................................................................................................1-1
1.1 Monitor Unit/Control Unit.................................................................................................1-2
1.2 Control Unit .....................................................................................................................1-6
1.3 Transceiver Unit ..............................................................................................................1-8
1.4 Hull Unit...........................................................................................................................1-9
1.5 Interface Unit.................................................................................................................1-27
1.6 Motion Sensor MS-100 (option) ....................................................................................1-28
1.7 Clinometer BS-704 (option)...........................................................................................1-29

2. WIRING .................................................................................................................................2-1
2.1 Wiring Among Units ........................................................................................................2-1
2.2 Transceiver Unit ..............................................................................................................2-4
2.3 Hull Unit...........................................................................................................................2-6
2.4 Interface Unit...................................................................................................................2-7
2.5 I/O Sentences .................................................................................................................2-8

3. ADJUSTMENT ......................................................................................................................3-1
3.1 General Checks ..............................................................................................................3-1
3.2 Checking TX Frequency..................................................................................................3-2
3.3 Heading Adjustment Setting............................................................................................3-4
3.4 Setting for Synchronizing Transmission with other Equipment .......................................3-5
3.5 Setting for Satellite Compass..........................................................................................3-6
3.6 Setting of Motion Sensor/Satellite Compass...................................................................3-8
3.7 System Back Up..............................................................................................................3-9
3.8 Setting of Interface Unit.................................................................................................3-10

APPENDIX 1 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL ..........AP-1
APPENDIX 2 HOW TO INSTALL THE RETRACTION TANK FOR WOODEN VESSEL......AP-7

PACKING LISTS....................................................................................................................... A-1


OUTLINE DRAWINGS.............................................................................................................. D-1
INTERCONNECTION DIAGRAMS........................................................................................... S-1

www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
The paper used in this manual
is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN

All rights reserved. Printed in Japan A : APR . 2005


H : MAY 07, 2019
Pub. No. IME-13250-H
( ETMI ) CH-300

0 0 0 1 5 1 9 0 2 1 7
SAFETY INSTRUCTIONS
Read these safety instructions before you operate the equipment.

Indicates a condition that can cause death or serious


WARNING injury if not avoided.

Indicates a condition that can cause minor or moderate


CAUTION injury if not avoided.

Warning, Caution Prohibitive Action Mandatory Action

WARNING WARNING
ELECTRICAL SHOCK HAZARD Installe the specified transducer tank
Do not open the equipment. in accordance with the installation
instructions. If a different tank is to be
Only qualified personnel installed the shipyard is solely respon-
should work inside the sible for its installation, and it should
equipment. be installed so the tank doesn’t strike
an object.
Turn off the power at the switchboard
before beginning the installation. The tank or hull may be damaged if the
tank strikes an object.
Fire or electrical shock can result if the
If a steel tank is installed on a wooden
power is left on.
or FRP vessel, take appropriate
measures to prevent electrolytic
Do not install the equipment where it corrosion.
may get wet from rain or water splash.
Water in the equipment can result in fire, Electrolytic corrosion can damage the hull.
electrical shock or equipment damage.
Be sure that the power supply is
compatible with the voltage rating of
Be sure no water leaks in at the transdu- the equipment.
cer installation site.
Connection of an incorrect power supply
Water leakage can sink the vessel. Also can cause fire or equipment damage. The
confirm that the transducer will not loosen voltage rating of the equipment appears
by ship’s vibration. The installer of the on the label above the power connector.
equipment is solely responsible for the
proper installation of the equipment.
FURUNO will assume no responsibility for
any damage associated with improper
installation.

i
CAUTION CAUTION
Ground the equipment to prevent WORKING WITH THE SONAROIL
electrical shock and mutual
interference. Precautions
Keep oil away from eyes. Wear protective
Observe the following compass safe gloves when working with the oil. The oil
distances to prevent deviation of a can cause inflammation of the eyes.
magnetic compass:
Do not touch the oil. Wear protective
Standard Steering gloves when working with the oil. The oil
can cause inflammation of the skin.
CH-302/ 0.80 m 0.55 m
MU-100C Do not ingest the oil. Diarrhea or vomiting
CH-303 0.55 m 0.30 m
can result.

IF-8000 0.95 m 0.65 m Keep the oil out of reach of children.


CH-302 0.30 m 0.30 m
Emergency
CH-256 0.30 m 0.30 m If the oil enters eyes, flush with clean
water about 15 min. Consult a physician.

Install the monitor unit MU-100C out of If the oil contacts skin, wash within soap
direct sunlight. and water.

It is difficult to see the display in direct If the oil is ingested, see a physician
sunlight. immediately.

Keep hands away from the raise/lower Disposal of oil and its container
shaft of the hull unit when it is working. Dispose of oil and its container in
accordance with local regulations.
Injury to hands may result if they become For further details, contact place of
caught in the shaft. purchase.

Do not exceed 20 knots when operating Storage


the equipment and do not exceed 15 Seal container to keep out foreign
knots when raising or lowering the material. Store in dark place.
transducer.

The transducer shaft may become damaged.

The hull unit is designed to withstand ship’s


speed of 20 knots. For vessel with greater
speed, reinforce the hull unit.

The transducer tank should be mounted at


the place above the waterline. If this is
impossible, make safety provisions (ex.
construction of watertight compartment).

If there is a possibibility of vibration at the


soundome in high-speed cruising, which
creates prssure inside the tank, discuss the
problem with shipyard and hull manufacturer.

ii
SYSTEM CONFIGURATION
INTERFACE UNIT IF-8000

MONITOR UNIT MU-100C


Note 2

Navigator

Control Unit

Note 1

Display
Unit
VGA Ext. Remote
Monitor Controller
Note 2

CONTROL UNIT CH-302

TRANSCEIVER UNIT
CH-303 Satellite compass
12-24 VDC or
NMEA Input

DATA/VIDEO OUT

Rectifier
Speaker RU-1746B-2

Motion Sensor

100/110/200/220 VAC

12-24 VDC

12/24 VDC
HULL UNIT
Note 1: MU-100C is the standard supply CH-304/305
monitor unit. An external monitor
may be connected via the
interface unit (option). The drawing
above shows the system configuration
with the MU-100C.
Note 2: For blackbox type, MU-100C is
not supplied. Connect external
monitor (user supply) and control
unit to the interface unit.

iii
EQUIPMENT LISTS

Standard Supply
Name Type Code no. Qty Remarks
Control Unit/ CH-302/
- 1 Not supplied with blackbox type
Monitor Unit MU-100C
Control Unit CH-302 - 1 Not supplied with unibody type
Interface Unit IF-8000 - 1 For blackbox type (not required for MU-151C)
Transceiver Unit CH-303 - 1
CH-304 - 400 stroke See the following table for
Hull Unit 1
CH-305 - 250 stroke Hull Unit Standard Supply.
SP06-01101 001-360-670 1 For unibody type*
SP06-01102 006-556-210 1 For transceiver unit*
Spare Parts
SP06-01103 006-558-990 1 For hull unit*
SP06-01111 006-556-220 1 For interface unit*
CP06-01200 000-068-496 06S4078 (5 m), 06S4080 (15 m), CP06-01251*
CP06-01201 000-068-497 06S4078 (5 m), 06S4080 (30 m), CP06-01251*
CP06-01202 000-068-498 06S4078 (5 m), 06S4080 (50 m), CP06-01251*
1 set
CP06-01203 000-068-499 06S4078 (10 m), 06S4080 (15 m), CP06-01251*
CP06-01204 000-068-500 06S4078 (10 m), 06S4080 (30 m), CP06-01251*
Installation
CP06-01205 000-068-502 06S4078 (10 m), 06S4080 (50 m), CP06-01251*
Materials
CP06-01261 006-562-580 1 For transceiver unit*
CP06-01501 006-561-620 1 set For hull unit*
CP02-06600 000-012-486 MJ-A10SPF0002-0015 (0.15 m), for unibody type
CP02-06610 000-012-480 1 set MJ-A10SPF0002-015 (1.5 m ), for blackbox type
CP02-06620 000-012-481 MJ-A10SPF0002-050 (5 m), for blackbox type
FP02-05100 000-012-474 For unibody type, FP02-05101*, hood
Accessories 1 set
FP06-01410 000-068-630 For control unit, FP06-01120*, hard cover
*: See the lists at the back of this manual.

Hull Unit Standard Supply


Name Type Code no. Qty Remarks
Raise/lower CH-3041 -
1 set
Drive Unit CH-3051 -
Soundome CH-3042 - 1 set
Flange CH-2543 006-557-810 1 set See the lists at the back of this manual.
Includes liquid gasket.
000-068-681
Assembly Kit for See the lists at the back of this manual.
CH-2544 1 set
field Without liquid gasket.
001-497-120
See the lists at the back of this manual.
SHJ-0006 661-000-062 2.2 m, for 3.5/5.2 m cable
Shaft 1
06-007-1572 600-715-721 3.8 m, for 5.2m cable
Sonar Oil 4 lit. 000-824-033 1

iv
Options
Name Type Code no. Remarks
Remote Controller CH-256-E 000-068-492
Interface Unit IF-8000 -
Motion Sensor MS-100 -
Monitor Unit MU-100C -
Control Unit CH-302-E -
Clinometer BS-704 -
Loudspeaker CA-151S-ASSY 001-466-200
CA-150BS-ASSY 000-190-183
Rectifier RU-1746B-2 000-030-439
MJ-A6SPF0012-050C 000-154-053 6pin-6pin, 5m
MJ-A6SPF0012-100C 000-154-037 6pin-6pin, 10m
Cable assy.
MJ-A6SPF0011-050C 000-159-690 6pin-4pin, 5m
MJ-A6SPF0011-100C 000-159-691 6pin-4pin, 10m
OP06-15-1.5 NEW 006-559-140 For desktop, with 1.5 m
OP06-15-5 NEW 006-559-150 For desktop, with 5 m
Control Unit
OP02-83-1.5 001-413-600 For flush mount, with 1.5 m
Separate Kit
cable
OP02-83-5 001-413-610 For flush mount, with 5m cable
OP06-16 006-556-300 For unibody type
Flush mount kit OP06-17 006-556-310 For separated display unit
OP06-18 006-556-320 For control unit
06-007-1570-2 001-428-120 Steel, 1m
SHJ-0001-2 001-428-150 Steel, 1.8m
06-007-1571-2 001-241-270 Steel, 3.5m
Tank
06-021-4024-0 001-428-260 FRP, 1m
06-007-1573-0 600-715-730 FRP, 1.8m
OP10-5 000-019-283 Aluminum, 1m
Fairing 06-021-4502 001-159-790-10 For an FRP ship
Soundome Shaft 06-007-1591 001-261-030 3m

v
This page is intentionally left blank.

vi
1. MOUNTING

NOTICE
Do not apply paint, anti-corrosive sealant
or contact spray to coating or plastic
parts of the equipment.

Those items contain organic solvents that


can damage coating and plastic parts,
especially plastic connectors.

Necessary tools and materials


To install the units, prepare the tools and materials shown below.
Necessary Tools

Name Specification Qty Remarks


For M10 (Hex. size 17 2 Recommended: double offset
mm) wrench
For M20 (Hex. size 30 2
mm)
Wrench
For M8 (Hex. size 13 mm) 1
For M6 (Hex. size 10 mm)) 1
For M36 (Hex. size 55 1*
mm)
Pipe Wrench 55 mm 2*
Ball Wrench For M5 (Hex. size 4 mm) 1 Supplied with the hull unit.
Phillips-head #1 1
Screwdriver
#2 1
Socket Driver For M4 (Hex. size 7 mm) 1
Cutter Knife - 1
Nipper - 1
Crimp Tool - 1 For FV2-4
Soldering Iron - 1 If needed for wiring
Liquid Gasket TB1121 or TB1184 1 Liquid gasket may not be supplied
(ThreeBond Holdings Co., with the product because of
Ltd. export restrictions in each country.
If not included, prepare specified
liquid gasket locally.
*: Prepare two pipe wrenches or one pipe wrench and one wrench (M36).

1-1
1. MOUNTING

Necessary Materials
Name Specification Qty Remarks
Power Cable DPYCYS-2.5 2 Prepare the sufficient cable length
according to the mounting location.
Ground Wire IV-2sq. 2
Crimping Terminal FV2-4 2 For the ground wire
10 A (For 12 VDC) 1 Connect between the transceiver
unit and power source.
5 A (For 24VDC)
DC Breaker
30 A (For 12VDC) 1 Connect between the hull unit and
power source.
15 A (For 24VDC)
Vinyl Tape - - If needed for wiring
Solder - -

1.1 Monitor Unit/Control Unit


This searchlight sonar has two types of shipments, unibody type which is
shipped with monitor unit, and blackbox type which is shipped without a monitor
unit, but has an interface unit. For blackbox type, see page 1-5.

The control unit can be installed together with the monitor unit, or independently
of the monitor unit. For separate installation, the optional monitor kit is required.
These units can be installed on a tabletop or flush mounted in a console or
panel.

1.1.1 General mounting considerations


• Keep the monitor unit out of direct sunlight.
• Select a location where the unit(s) can easily be operated while observing the
fishing ground or area surrounding the vessel.
• For maintenance and checking purposes, leave sufficient space at the sides
and rear of the unit and leave slack in cable. (Refer to the outline drawing at
the back of this manual.)

1-2
1. MOUNTING

1.1.2 Mounting Unibody type


1. Fasten the mounting base to the mounting location with four self-tapping
screws (5X20).

FRONT

Mounting base
2. Fasten the bracket at the rear of monitor/control unit with four binding screws
(M4x10).

Bracket (rear view)


1 2
1 2

3 4
3
4

Bracket, rear view


3. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten bracket to
mounting base.
4. Fasten the bracket to the mounting base with two upset screws. (Use the
upper holes to tilt the monitor unit 20°; lower holes to tilt it 9°.)
For 9 tilt

Mounting base

For 20 tilt

Bracket

Upset Screw

Fastening bracket to mounting base

1-3
1. MOUNTING

Flush mounting
Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300)
Name Type Code No. Qty Remarks
Fixing metal 06-021-1311-2 100-279-612-10 1
Self-tapping screw 5x20 000-162-609-10 6
Hex. bolt M4x12 000-162-939-10 4

1. Cut out a hole (W287 x H297) in the mounting location.


2. Fasten monitor/control unit with the fixing metal (supplied) and four hex. bolts
(M4x12, supplied).
3. Fasten the fixing metal assembled at step 2 to hole made at step 1 with six
self-tapping screws (5x20, supplied).
Hex. bolts

Fixing metal

1.1.3 Mounting separated monitor unit


1. Fasten the mounting base to the mounting location with four self-tapping
screws (5x20).

FRONT

Mounting base
2. Dismount the coupling plate to separate monitor unit from control unit.

1-4
1. MOUNTING

3. Attach the bracket at rear of the monitor unit with four binding screws
(M4x10).

Bracket (rear view)

1 2
1 2

3 4
3 4

Bracket, rear view


4. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten bracket to
mounting base.
5. Fasten the bracket to the mounting base with two upset screws. (Use the
upper holes to tilt the monitor unit 20°; lower holes to tilt it 9°.)

Flush mounting for monitor unit (Type: OP06-17, Code no. 006-556-310)
Name Type Code No. Qty Remarks
Fixing metal 06-021-1321-2 100-279-622-10 1
Self-tapping screw 5x20 000-162-609-10 4
Hex. bolt M4x12 000-162-939-10 4
1. Cut out a hole (W287 x H207) in the mounting location.
2. Fasten the fixing metal (supplied) to the monitor unit with four hex. bolts
(M4x12, supplied).
3. Fasten the fixing metal assembled at step 2 to hole made at step 1 with four
self-tapping screws (5x20, supplied).
Hex. bolts

Fixing metal

1-5
1. MOUNTING

1.1.4 Blackbox type


The blackbox type requires a VGA monitor, connected via the interface unit
IF-8000. Supply commercial monitor and interconnection cable (Max. length 15
m with Dsub-15P connectors of male, three rows of 15 pins). The monitor used
should satisfy the specifications shown below.
• VGA type
• ANALOG RGB 0.7 Vpp, positive polarity
• TTL level H, V, Negative polarity

Note: The LCD monitor MU-151C does not require the interface unit IF-8000.
For details, see the operator’s manual for MU-151C.

1.2 Control Unit


For blackbox type, fix the control unit to the mounting plate (supplied as
accessories).

See the parts list of FP06-01120 and outline drawings at the back of this manual.

1. Fix the mounting plate to the place selected with two self-tapping screws
(5X20, supplied).
2. Fix the bracket to the control unit with two hex. screws (M4X12, supplied).
3. Insert the screwdriver from the top of the mounting plate holes and then
tighten two hex. screws (M4X12) loosely.
4. Attach the control unit to the mounting plate, and fasten two hex. screws
tightly.
5. Attach two cosmetic caps to the holes at the top of the mounting plate.
Mounting plate Cable Fasten the screws to fix
Cable entrance hole the bracket.

Tapping screws (5X20)


Insert to the hex.
Bracket screws tightened
at step 3.

Bracket
Cable can be passed this direction.

6. Attach hard cover to protect the control unit.


How to remove the hard cover
Place your thumbs at the locations shown with
circles in the illustration at right, and then lift the
cover while pressing it with your thumbs.

1-6
1. MOUNTING

To mount the control unit separate from the monitor unit, the optional control unit
separate kit is required. Mount the control unit same as the above procedure.
See the outline drawing at the back of this manual to mount.

Type: OP06-15-1.5 NEW Code no.: 006-559-140: with 1.5 m cable


Type: OP06-15-5 NEW Code no.: 006-559-150: with 5 m cable
Name Type Code no. Qty Remarks

Cable MJ-A10SPF0002-015 000-142-878 For 1.5 m cable


1
MJ-A10SPF0002-050 000-131-411 For 5 m cable

Bracket 06-021-2112 100-281-880-10 1

Mounting Plate 06-021-2111-1 100-279-741-10 1

Self-tapping Screw 5x20 000-162-608-10 2

Cosmetic Cap DP-687 000-165-997-10 2

Hex. bolt M4x12 000-162-939-10 4

Flush mounting for control unit


Type: OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable)
Type: OP03-83-5, Code no.: 001-413-610 (5m cable)
Name Type Code No. Qty Remarks

Fixing metal 06-021-2101-2 100-279-732-10 1

Self-tapping screw 5x20 000-162-609-10 4

Hex. bolt M4x12 000-162-939-10 2

MJ-A10SPF0002-015 000-142-878 1 1.5 m Select


Cable assembly one.
MJ-A10SPF0002-050 000-131-411 1 5m

1. Cut out a hole (W287 x H87) in the mounting location.


2. Fasten the fixing metal to the control unit with two hex. bolts (M4x12,
supplied).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four
self-tapping screws (5x20, supplied).
Hex. bolts

Fixing metal

1-7
1. MOUNTING

1.3 Transceiver Unit


1.3.1 General mounting considerations
• The mounting location should be well ventilated and dry.
• The unit can be mounted on a bulkhead or the deck.
• The maximum cable length between the transceiver unit and the raise/lower
drive unit is 50 m.
• The maximum cable length between the transceiver unit and the monitor
(interface) unit is 10 m.
• Keep the transceiver unit out of splash.

1.3.2 Mounting method


Fasten the transceiver unit with four self-tapping screws (5X20).
For bulkhead mounting, do as follows:

1. Tighten upper self-tapping screws so there is 5 mm clearance between


bottom of screw head and bulkhead.
2. Hook the transceiver unit on the upper screws.
3. Tighten the upper screws followed by the lower screws.
475
428
4- 6
FIXING HOLES

LED
296.5+1
340
16.5

455+1
82

Transceiver unit

1-8
1. MOUNTING

1.4 Hull Unit

NOTICE NOTICE
The flange of the retraction tank Install the hull unit away from the
must be parallel with the waterline. places subject to water splash and
rain.
The keel of the ship may not be
parallel with the ship’s draft. Fire or damage to the unit can result.
If necessary, waterproof the unit.

1.4.1 General mounting considerations


• Noise and air bubbles will affect performance.
• Do not turn on the equipment with the transducer exposed to air. Exposing the
transducer to air may damage it.
1.4.2 Installation position considerations
Discussion and agreement are required with the dockyard and ship owner in
deciding the location for the hull unit. When deciding the location, take into
account the following points:
• Select an area where propeller noise, cruising noise, bubbles and interference
from turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s
length from the bow or near the keel is the best. If the hull unit cannot be
installed on the keel, the center of the retraction tank should be within 1 meter
of the keel to prevent a rolling effect.
For a wooden vessel: Install the hull unit off the keel.
For other than a wooden vessel: On-the-keel installation is advantageous in
comparison with off-the-keel.

For a wooden vessel For other than a wooden vessel


Retraction tank Retraction tank

Mounting range 1/3


1/2 Keel Keel
Within 1 m Within 1 m

• Select a place where interference from the transducers of other sounding


equipment is minimal. The hull unit should be at least 2.5 meters away from
the transducers of other sounding equipment.
• An obstacle in the fore direction not only causes a shadow zone but also
aerated water, resulting in poor sonar performance. Be sure to locate the
transducer well away from any obstacle in the fore direction.

1-9
1. MOUNTING

Mounting method
A typical mounting method is shown in the outline drawing at the back of this
manual. Consult ship’s owner, dockyard and user to determine appropriate
mounting method. Pay attention to safety (strength, watertightness) first,
followed by ease of maintenance and inspection.

1.4.3 Retraction tank


Note: For installation of the retraction tank on a wooden vessel, see Appendix 1
and Appendix 2.

Tank length
Shorten the retraction tank so the transducer is lowered into water as deep as
possible. Pay particular attention to the tank length Lt. Determine the length of
the main shaft.
• Length of main shaft = Lt + 200 mm (for 400 stroke)
• Length of main shaft = Lt + 50 mm (for 250 stroke)
Note: When the retraction tank is constructed locally, finish it so that welding
beads do not protrude on the inner surface of the tank. The tank guide will
hit the bead, burning out the raise/lower motor. Also, do not position the
welding bead in the ship’s fore-aft line.

Welding bead

Welding bead

1-10
1. MOUNTING

Guideline for the installation on a steel or aluminum hull


When the retraction tank is installed on a steel or aluminum hull, follow the
guideline shown below and see the outline drawing at the back of this manual.
• The flange of the retraction tank must be parallel with the waterline.
• Fit a doubling plate (a plate to reinforce the hull plate) of 600 mm or more
diameter to the outside of the hull plate (see the figure below). For the
doubling plate, use the same material and thickness as hull plate.

Retraction tank

Hull plate

Doubling plate

• Weld four reinforcement plates to the retraction tank.

Reinforcement plate

(Unit: mm)
Li: The length of the tank

Min. 500
Bow
Li

Mi
n.
1205
0
t
Thickness (t): More than hull plate
Hull plate Doubling plate:
Fit it to the outside of the hull plate.

1-11
1. MOUNTING

• If the length of the retraction tank (Li) is more than 1 m, install at least one
reinforcement rib to prevent damage of the tank and vessel by sea accident.
One reinforcement rib should be installed toward the ship’s bow (see the
figure below). It is recommended that four reinforcement ribs are installed.
• For the reinforcement ribs, fit doubling plates to the location where the
reinforcement ribs are welded to the bulkhead of the vessel (see the figure
below).

Min
. 10
Retraction tank 0 Doubling plate
Thickness: More than hull plate

Min. 150
Min. 200 Bow
Reinforcement rib
Min. 100

Min. 150
(Unit: mm)

t
Thickness (t): More than hull plate

1-12
1. MOUNTING

• Install a fairing plate to the bottom hull where the transducer projects to protect
the transducer from the water pressure. The fairing plate should contact the
frame of the hull plate.
For the fairing plate, use the same material and thickness as the hull plate.
The wooden or plastic material is also available.
Note: When you install the fairing plate with bolts, fill the bolt holes with the
silicon sealant to smooth the water flow.

For using the same material and thickness as the hull plate
Make a fairing plate to refer the figure below. The figure is the example of the
development diagram.

Bow

Air vent

Example: Development diagram of the fairing plate

Frame

Bow
Hull plate

Doubling plate

After installing the fairing plate

For using the wooden or plastic material


Make a fairing plate to refer the figure below.

1-13
1. MOUNTING

For small FRP ship


The retraction tank should be mounted in parallel with the ship’s draft. For a
small ship, however, the hull has 2 degrees of tilt rising toward the bow. This
creates high water pressure in the tank because of the resistance at the rear of
the tank well. To solve this problem, attach a fin to the hull at the location shown
in the figure below.

Retraction tank

Bottom of ship

Fin

This fin creates a smooth stream in the retraction dome. Fin specifications:
Height, 1-1.5 cm, Material, FRP.

Mounting of retraction tank


Install the retraction tank referring to the hull unit outline drawings at the back of
this manual.

Note 1: When making a retraction tank locally, the inside diameter of the
retraction tank should be φ190±0.5 as shown in the outline at the back of this
manual. If larger, the hull unit may be damaged.

Note 2: Locate the retraction tank so that the center of any two bolt holes is
facing the ship’s bow.

a=b
a
Bow
b

1-14
1. MOUNTING

1.4.4 Assembling and mounting of hull unit


The hull unit is shipped as the parts shown in the hull unit kit in the Equipment
Lists (page v). Assemble the hull unit as shown in the procedure below.

Note: Confirm the frequency of soundome before mounting by referring to the


table below.
Frequency Specification

60/153 kHz There is NO label attached on the dome.

There is the label “85/215 kHz” attached


85/215 kHz
on the dome.
For 85/215 kHz, the label is
attached here.

1. Calculate necessary length of main shaft from the length of retraction tank Lt
and cut off the unnecessary portion.

Supplied length: 2.2 m or 3.8 m

Lt + 200 mm for 400 mm travel


Lt + 50 mm for 250 mm travel

Take care Chamfer the edge to


not to damage. protect O-ring from
damage.

1-15
1. MOUNTING

2. Remove hex bolt, nut, spring washers, flat washers and trunnion pins from
the main body flange. Then, mount the raise/lower drive unit on the shaft
sleeve by using the hardware removed.

ING
RN
WA
ING
RN
WA

Raise/lower
drive unit

Flat Nut
washer

Hex. bolt Flange assembly


(M10X30)
Spring washer
Flat washer

Trunnion pin

Shaft sleeve and raise/lower drive unit assembly


3. Pass the transducer cable through the main shaft.

1-16
1. MOUNTING

4. After fully screwing the main shaft into the soundome neck, unscrew it by four
turns and apply the supplied sealant (LOCTITE NO.575) to the threads.

Main Shaft

Grasp the soundome neck with a wrench,


and tighten the shaft with a pipe wrench.

Coat threads with the sealant


(LOCTITE NO.575).

Applying the sealant to main shaft


5. Screw in the main shaft completely.
6. Remove any excess sealant with a waste cloth. The sealant does not harden
when exposed to air.
7. As shown in the drawing below, confirm that the narrowest gap between the
tank guide, and retraction tank in the range (20 to 170 mm) is within 0.5 mm.

0.5 0.5
20
450

Tank and tank guide, sectional view

1-17
1. MOUNTING

8. If the gap at a side is more than 0.5 mm, install shim(s) to make the gap
within 0.5 mm.
a) Unscrew four M10x50 bolts.
b) Unscrew four countersunk screws, then attach shim(s) with the countersunk
screws as shown below.

Hex. bolt (M10×50)

Spring washer
Flat washer

Countersunk screw (M4×16)


Guide plate
Shim: Adjust the gap
with additional
shims supplied.
Default: 1mm
thickness shim
Flat washer plate attached.
Nut

Installing shims

1-18
1. MOUNTING

The table below shows tank length and necessary shim thickness. In addition,
the shim thickness shown is for one side. For example, when cutting the 1800
mm tank to 800 mm, the tank inside diameter is 191.25 mm, and shim thickness
is 2.5 mm as shown the table in below.

㻝㻤㻜㻜 8
Length A (mm) tank shortened

㻝㻢㻜㻜 7
㻝㻠㻜㻜

Shim thickness (mm)


6
㻝㻞㻜㻜
5
㻝㻜㻜㻜
4
㻤㻜㻜
3
㻢㻜㻜
2
㻠㻜㻜
㻞㻜㻜 1

㻜 0
㻝㻤㻥 㻝㻥㻜 㻝㻥㻝 㻝㻥㻞 㻝㻥㻟 㻝㻥㻠
Tank inside dia. ĭ B (mm)

For 1 m tank

For 1.8 m tank

Shim thickness

The table below shows number of shims required and shim thickness.
Shim thickness 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5
t2.0 1 1 1 1 2 2 2 2 2 2
t1.0 1 1 1 1 1 1 2 2
t0.5 1 1 1 1 1 1 1
Inside dia of tank 188.1 188.7 189.3 189.9 190.5 191.1 191.7 192.3 192.9 193.5 194.1 194.7 195.3 195.9

1-19
1. MOUNTING

9. Coat the inside of the tank guide with liquid gasket (TB1121 or TB1184).
Then, fasten tank guide at the neck of the main shaft securely with M10X80
bolts.

Hex. bolt : Coat with liquid gasket


(M10x80) (TB1121 or TB1184).

Flat washer
Spring washer
Bow mark
Nut
(white circle)
XXX
The Frequency * Bow
is described. Align the tank guide with the bow mark
HEAD

to face toward ship's bow.

Bow mark

Tank guide attachment


10. Pass the main shaft through the flange assembly.
11. Pass the main shaft through the shaft retainer at the raise/lower drive unit.

Pipe cap

U-nut
Shaft retainer

Spring washer
Hex. bolt M10X35

Bow mark
Main body flange

Bow

1-20
1. MOUNTING

12. Align the bow mark on the soundome with the bow mark on the flange
assembly, and then fix the main shaft with and shaft retainer.
13. Fix the jubilee clip to the main shaft.

Hex. bolt

Shaft retainer 15 mm
1-2 mm

Jubilee Clip

Main shaft

Note: Attach the shaft retainer so it is 15 mm from the top of the shaft. The
soundome is then placed 10 mm above the bottom of tank when retracted.
14. Insert grease cotton (supplied with flange assembly), and fix them with the
cotton retainer as follows.
a) Wind grease cotton onto main shaft.
b) Mark on the cotton as below.
c) Remove the cotton from the shaft, and then cut it at the position of the mark.
Discard the ends.
d) Wind cottons as shown below.
e) Push cottons into the flange assembly.
15. Tighten the grease cotton retainer.

Wind grease cotton Space joints of grease cotton


onto main shaft and 120 apart and push them into
cut it as shown below. body flange.

Spring washer
Cotton retainer

Installing grease cotton on the main shaft


16. Fasten the pipe cap (supplied) to main shaft.
17. Unscrew eight pcs. of M5x30 socket head cap screws with soundome fixing
tool to dismount soundome.
Note: Do not unfasten two nuts painted in red.

1-21
1. MOUNTING

18. Remove and discard the protection sponge placed in soundome.

NOTE
Do not unfasten two nuts
painted in red. Socket head cap screw
8 pcs, M5x30
Unfastening the nuts may allow
water to leak inside, which can Spring washer
damage the soundome.

Rotate 4 or 5 turns by hand to make


O-ring
sure that turning mechanisms are
functioning properly.
Remove.
Apply anti corrosive sealant.

Trusshead screws (6 pcs.)


Protection sponge
Do not unfasten these trusshead
screws. Oil may leak inside.

Soundome

Detaching the soundome


19. Stand the soundome upright on top of the soundome packing. Fill the
soundome with oil (supplied) so the level is 5 cm from the top of the
soundome. Keep the soundome packing for future use.

Ball wrench

Sonar oil

5 cm

Stand the soundome upright


on top of the soundome packing.

Filling the soundome with sonar oil

1-22
1. MOUNTING

CAUTION
Keep oil away from eyes. Where protective
goggles when working with the oil. The oil
cause inflammation of the eyes.

Do not touch the oil. The oil can cause


inflammation of the skin. Wear protective
gloves when working with the oil.

Do not ingest the oil. Diarrhea or vomiting


can result.

Keep the oil out of reach of children.

EMERGENCY
If the oil enters the eyes, flush with clean
water about 15 minutes. Consult a
physician. If oil contacts skin, wash with
soap and water. If the oil is ingested, see a
physician immediately.

DISPOSAL OF OIL AND ITS CONTAINER


Dispose of oil and its container in
accordance with local regulations.
For further information, contact place of
purchase.

STORAGE
Seal container to keep out foreign material.
Store in dark place.

20. Rotate the transducer manually to position it at the angle shown below, and
then refit the soundome.

Transducer

Soundome

Note 1: Do not lay the oil-filled soundome down for five minutes. Oil may leak.

1-23
1. MOUNTING

Note 2: When the soundome is painted (to keep marine life off the transducer),
observe the following precautions:
x Use only anti-fouling paint type MARINE STAR 20 (Manufacture: Chugoku
Marine Paint Co., Ltd., Japan).
x Paint only the plastic portion of the dome. Painting the metal parts causes
electric corrosion.

Paint area

21. Clean surface of flange gasket, retraction tank flange and shaft sleeve
22. Apply approx.1 mm thickness of liquid gasket (TB1121 or TB1184) to the
retraction tank flange. For the application area, see the following figure.
Note: Do not apply liquid gasket to the flange gasket. If applied, clean the
flange gasket with waste cloth.
Retraction tank flange

Liquid gasket application area:


Apply approx. 1 mm thickness of
liquid gasket. Be careful not to
apply to the bolt holes.

23. Apply a slight coat of anti corrosive sealant (KINORUSTER 855) to bolts,
nuts and washers.
24. Set the hull unit into the retraction tank, taking care not to damage the
soundome.

U-nut

Shaft retainer
Spring washer
Hex. bolt M10X35

Nut

Spring washer
Flat washer
Bow mark
Flange assembly

Flange gasket

Retraction tank
flange

Flat washer

Hex. bolt M20X80

1-24
1. MOUNTING

25. Fix the shaft sleeve and retraction tank with hex bolts, flat washers and spring washers.

Hex bolt

Shaft retainer 15 mm
1-2 mm

Jubilee clip

Main shaft

Bow

10 mm

1-25
1. MOUNTING

Checking manual raise/lower of soundome with hand crank


Perform this check after all wiring has been completed.

CAUTION
Turn the main power off before this check,
otherwise the raise/lower motor action may
cause injury.

1. Turn off the breaker on the hull unit.


2. Detach the gear cover.
3. Set wrench (opposite side19 mm) to the screw shaft gear.
4. The transducer should rise/lower smoothly with even force in upper to lower
limits. If not, the centers of the shaft sleeve and the retraction tank are not
aligned. Adjust the hull mounting position if necessary. Check the following
points.
• Painting inside tank not smooth.
• Inner diameter of tank not uniform.
• Welding bead is obstructing raising and lowering.

1-26
1. MOUNTING

1.5 Interface Unit


The interface unit is shipped with the blackbox type to enable connection of a
monitor. Note that this unit is not necessary when using monitor MU-151C.

1.5.1 General mounting considerations


• The mounting location should be well ventilated and dry. Avoid locations
subject to water splash or rain.
• The unit can be mounted on a bulkhead or the deck.
• The maximum cable length between the interface unit and the transceiver unit
is 10 m. Keep the length in mind when choosing a mounting location.

External
monitor

Transceiver 06S4078 Interface


06S4078
Monitor unit
unit unit MU-100C A+B<=15m
A B

External External
monitor monitor

Transceiver 06S4078 Interface 06S4078 Interface A+C<=15m


unit unit unit
A C

1.5.2 Mounting method


Fasten the interface unit with four self-tapping screws (5X20, local supplied).
For bulkhead mounting, do as follows:

1. Tighten upper self-tapping screws so there is 5 mm clearance between


bottom of screw head and bulkhead.
2. Hook the transceiver unit on the upper screws.
3. Tighten the upper screws followed by the lower screws.
335
295 4- 6
FIXING HOLES
79+0.5 23
120

137

315+0.5

1-27
1. MOUNTING

1.6 Motion Sensor MS-100 (option)


The MS-100 measures ship’s pitching and rolling angles with a sensor, using the
principles of the gyroscope. The MS-100 is free from error caused by ship’s
vertical and horizontal motion. Therefore, it can be installed at any convenient
location. However, ship’s semi-permanent inclination due to loading imbalance
cannot be detected. Compensate for this as described in Chapter 3.

1.6.1 Mounting considerations


• Vibration in the mounting area should be minimal.
• Locate the unit away from areas subject to water splash.
• The ambient temperature should not exceed 50°C.
1.6.2 Mounting procedure
Orient the FORE mark on the unit toward the ship’s bow and mount the unit level
to within 5° in all directions. For the offset, see Chapter 3.

FORE
θ ≤ 5°

AFT

1-28
1. MOUNTING

1.7 Clinometer BS-704 (option)


The clinometer detects ship’s inclination caused by ship’s rolling, pitching and its
output is used to stabilize the sonar beam against rolling and pitching.

The clinometer is, in principle, a pendulum. It measures the inclination of the


ship by sensing the direction of gravity acted on it and therefore when installed
on a ship, it should be placed on or near the rotation axes of the ship’s rolling
and pitching. If it is placed away upward from the axes, the measured value
becomes larger than the actual value. On the other hand, if it is placed below the
axes, the measured value is smaller than actual value. The same can be said
when it is placed far to the left or right from the axes.

The rotation axes of pitching and rolling are theoretically considered to be


located on the level of the ship’s draft and in the center of the ship. In other
words, as follows:

1. Vertical position of the pitching and rolling axes is on the draft level of the
ship.
2. Horizontal position of the rolling axis is in the center of the ship’s
port-starboard line.
3. Horizontal position of the pitching axis is in the center of the ship’s fore-aft
line.

From 1, 2 and 3 above, the crossing point of the two axes is indicated by the
black dots in the illustration below. The clinometer should be mounted as close
as possible to this point.
Pitching Axis
Rolling Axis

Water line

Note 1: The area near the hull unit is too low to install the Clinometer and should
be avoided, since the polarity of the measured value is reversed.
Note 2: When it is impossible to install the clinometer on the intersecting point of
both rolling and pitching rotational axes, a special effort should be made to
install it at a place where the vertical distance to the intersecting point is
shortest.
Note 3: Install the clinometer with the bow mark pointing toward ship’s bow.
Note 4: Be sure to adjust the clinometer following the procedure in section 3.6.

1-29
1. MOUNTING

This page is intentionally left blank.

1-30
2. WIRING
2.1 Wiring Among Units
• The figure on the next page shows wiring among units.
• The signal cables are fitted with connectors. Connect the cables to the monitor,
transceiver and hull units referring to the interconnection diagram on page
S-1.
• The power cable should be arranged locally. Use power cable type
DPYCYS-2.5 (Japan Industrial Standard cable) or equivalent cables. Attach
crimp on lugs (FV2-4) as shown below.

Armor 30 40 5
FV2-4 (blue)

Braided shield
Wind
Vinyl sheath (Fold the braided shield back on the vinyl sheath.
vinyl tape.
Fix here with the cable clamp.)

Conductor

Insulator

Inclusion

Tape
Braided shield
Sheath
S = 2.5 mm 2 Armor
=15.2 mm Vinyl sheath

• The raise/lower drive motor and breaker are different depending on ship’s
mains.
• Install the mains switch for the sonar where it can be easily accessed. Turn off
this switch when the sonar is not being used, to reduce power consumption
and to prevent the transducer from slipping by vibration.
• If the D-sub connector is too large to pass through the hole in a bulkhead, etc.
remove it, pass the cable through the hole and then reattach the connector.

2-1
2. WIRING

Navigation equipment
Monitor/control unt
CH-302/MU-100C
Note 3
MJ-A10SPF0002-0015
0.15 m

Note 1
Remote
(5 m) controller

Note 2
Interface unit
*a
06S4078 IF-8000 Monitor
(5/10m) (User supply)
*b

Transceiver unit
CH-303

Note 4
MJ-A6SPF
0012 DPYCYS-2.5
Loudspeaker 12-24 VDC
(w/cable)
Satellite
compass
06S4037
Ext. KP
(10m)

Motion sensor
Clinometer 06S4081
(3.5/5.2m)

06S4080 (15/30/50m)
12/24 VDC
Hull unit 250V-DPYCYS-2.5
CH-304
CH-305

Note 1: Optional cable between the


monitor unit and control unit
for separate installation
-MJ-A10SPF0002-015 (1.5m)
-MJ-A10SPF0002-050 (5m)

Note 2 a b<15m
Note 3: MU-151C can be connected for MU-100C.
In this case, the monitor and control units should
be mounted seprately.
Also, the MU-151C requires the independent power.

Note 4: Satellite compass SC-50/110 can be connected.


See the schematic diagram.

Wiring, with monitor

2-2
2. WIRING

Interface unit
IF-8000

Note 1

Navigation equipment

Max. 15m
External monitor Note 2
Note 3
*a Interface unit External monitor
06S4078 Note 3 * b
(5/10m)

CONT
MJ-A10SPF0002-050
06S4078 (5m) REM

(5/10m)
Control unit
CH-302
Control unit, rear view
(5m)

Remote controller
Transceiver unit
CH-303
SPEAKER

MJ-A6SPF
Loudspeaker DPYCYS-2.5
0012 12-24VDC
(w/cable)
Satellite
compass
06S4081
Ext. KP (3.5/5.2m)
06S4037
(10m)

Monitor unit
Clinometer
12/24VDC
06S4080(15/30/50m) DPYCYS-2.5

Hull unit

CH-304
CH-305
Note 1: Two interface units may be connected.
Note 2: For interface unit, the external monitor (user
supply) is required.
Note 3 *a b<15m

Wiring, without monitor

2-3
2. WIRING

2.2 Transceiver Unit


Connect the cables as shown in the figure below.

06P0254
J3

7P-NH connector
(local supply)

J6

J5

J2
TB1
06P0255

06P0258
Tie these cables with + -
locking spacer.

*Note *Note
DATA/VIDEO OUT
SPEAKER Earth
External loudspeaker HULL Monitor unit MOTION SENSOR 12-24VDC
UNIT MU-100C Motion sensor To ship's
CA-151S-ASSY earth
or MS-100 DPYCYS-2.5
CA-150BS-ASSY 06S4080
Hull unit Interface unit or
External KP Ship's mains
CH-304/CH-305 IF-8000 Clinometer
12-24 DCV
BS-704
NMEA/SATELLITE COMPASS
Satellite compass
SC-50/110, etc.
*: Fix the braided shield with the clamp.

Transceiver unit, internal view

2-4
2. WIRING

Synchronizing Transmission with Echo Sounder or Other Sonar


To synchronize transmission of the CH-300 with an echo sounder or other type
of sonar, connect it as shown below.
H7P-SHF (local supply)
Transceiver unit

Vinyl wire (local supply) Sonar, E/S


AWG22-26
06P0254 J3 3 to 15V
KPI 3 KP OUT positive
EXT_SW 5 +5V to 15V
GND 6 GND

HULL UNIT clamp

Connection of transceiver unit to other sonar/echo sounder

Note: Outputting KP of CH-300 to other sonar, echo sounder

Transceiver unit

06P0254 J3
KPO 2 (E/S transmits, SONAR)
12V
positive GND 6

Outputting KP of CH-300 to other sonar, echo sounder

2-5
2. WIRING

2.3 Hull Unit


Pass the cables to the 06P0257 Board, through the cable protectors.

Fasten glands securely


by hand.

J2
06P0257 Cable from transducer
J1 06S4081
J3
Attach the EMI core RFC-4 (supplied)
*Note to this cable, and then fix the core to the
cable for JI with the cable tie CV-100N
(supplied).
J1 J2
Cable from transceiver unit
06S4080

*Note
TB2
+
Power cable
250V-DPYCYS-2.5
-
*Note

Power switch
06P0243 Should always be in up position (ON).

Earth
Connect to ship's earth.

*Note: Fix the braided shield with cable clamp.

Hull unit, inside view

Attaching EMI core RFC-4

2-6
2. WIRING

2.4 Interface Unit

CONT NMEA
DATA/VIDEO IN DATA/VIDEO OUT RGB OUT

Transceiver unit cable VGA NAV Earth


06S4078 monitor Control Connect to ship's earth.
Monitor unit unit
cable cable
06S4078 MJ-A10SPF0002
(1.5/5 m)
The blackbox type requires connection of a VGA monitor, via the interface unit
IF-8000. Supply monitor and interconnection cable (Max. length 15 m with
Dsub-15P connectors of male, three rows of 15 pins). The monitor used should
satisfy the specifications shown below.
• VGA type
• ANALOG RGB 0.7 Vpp, positive polarity
• TTL level H, V, Negative polarity

Note 1: Two interface units can be connected to the transceiver unit in parallel.
Note 2: When using DATA/VIDEO OUT port, cut and remove the rubber covers
as below to attach connectors to the interface unit.

Remove the
fixing metals.

Cut and remove


the covers.
Note 3: Connect control unit or navigator equipment to either interface unit or
monitor unit (supplied by FURUNO).
Note 4: When connecting the monitor unit MU-100C to the interface unit, or
two interface units in parallel to the transceiver unit, the length of cables should
be as shown in the figure on next page. Note that two cables 06S4078 (10 m
length) cannot be used.

2-7
2. WIRING

External
monitor

Transceiver 06S4078 Interface 06S4078 Display unit


unit A unit B MU-100C A+B<15m
Control unit may be connected
to interface unit or display unit.

External External
monitor monitor

Transceiver 06S4078 Interface 06S4078 Interface


unit unit unit A+C<15m
A C

Connect control unit to an


interface unit.

2.5 I/O Sentences


Talkers may be chosen from among GP, LC, LA, DR, DE and other (II). Refer
to “NAV DATA” in System Setting 1 menu.
Available I/O sentences

Sentences I/O Remarks


GLL I Geographic position, latitude/longitude
GGA I Global positioning system fix data
RMA I Recommended minimum specific LORAN-C data
RMC I Recommended minimum specific GPS/TRANSIT data
VTG I Course over ground and ground speed
VHW I Water speed and heading, any talker
HDG I Heading, magnetic, any talker
HDM I Heading, magnetic
HDT I Heading, true, any talker
VDR I Set and drift, any talker
DBS I Depth below surface, any talker
DBT I Depth below transducer, any talker, NMEA Version 1.5
DPT I Depth, any talker, NMEA Version 2.0
MTW I Water temperature, any talker
MDA I Water temperature, any talker
att I True heading, pitching, rolling, P sentence
TLL O Target latitude and longitude

2-8
3. ADJUSTMENTS

3.1 General Checks


General checks

3-1
$'-8670(17

General checks (con’t)

&KHFN,WHP &KHFNSRLQW5DWLQJ
:LULQJFKHFN $OOFDEOHVDUHFRUUHFWO\FRQQHFWHG
$OOOHDGZLUHVDUHWLJKWO\IL[HGZLWKFRQWDFWSLQV
RUFULPSRQOXJV
$OOVFUHZVDUHILUPO\IDVWHQHG
&DEOHVDUHILUPO\VHFXUHG
&DEOHVKLHOGVDUHSURSHUO\JURXQGHG
5HMHFWLQJVRXUFHRIQRLVHDQG 1RLVHJHQHUDWLQJPDFKLQHU\ PRWRU
LQWHUIHUHQFH UDGLRWHOHSKRQH79VHWHWF DUHQRWSODFHG
QHDUE\
0DJQHWLFGHYLFHVDUHQRWSODFHGLQWKHYLFLQLW\RI
GLVSOD\XQLW
(DUWK (DFKXQLWLVJURXQGHGZLWKDFRSSHUVWUDS
6KLS¶VPDLQVYROWDJH 6KLS¶VPDLQVYROWDJHLVVWDEOHRU9'&
:DWHUWLJKWQHVV :DWHUVKRXOGQRWOHDNIURPWKHPDLQERG\IODQJH
RUDORQJWKHPDLQVKDIW

3.2 Checking TX Frequency
&KHFNWKH7;IUHTXHQF\DIWHULQVWDOOLQJWKHHTXLSPHQW
 3UHVVWKHMENUNH\WRRSHQWKHPHQX
 3UHVVWKHFXUVRUSDGWRVHOHFW6<6DWWKHWRSRIWKHPHQXGLVSOD\
 3UHVVźWRVHOHFW*2726<60(18

MENU COM1 COM2 HORZ VERT ES SHORT-CUT SYS


GO TO SYS MENU YES NO

: SELECT : CHANGE MENU: END




User menu (SYS)


 3UHVVŻWRVHOHFW<(6WRGLVSOD\WKHV\VWHPPHQX

3-2
$'-8670(17

** SYSTEM MENU **
SYSTEM SETTING:
RANGE-SONAR MODE
RANGE-VERTICAL MODE
RANGE-E/S MODE
RANGE-TRACK MODE
COLOR PALETTE
LANGUAGE
SYSTEM BACKUP
LOAD BACKUP DATA
HEADING OFFSET, DRAFT OFFSET
ADJ MOTION SENSOR
TX FREQ ADJUST
TEST
TEST PATTERN
DEMO MODE
DEFAULT

: SELECT : MENU DISPLAY MENU: END




System menu
 3UHVVźWRVHOHFW7(67
 3UHVVŹWRVKRZWKHWHVWGLVSOD\

MAIN PROGRAM NO. 0650111-**.**


PANEL PROGRAM NO. 0650112-**.**
ROM : OK
RAM : OK
VRAM : OK
NMEA 1 : OK
NMEA 2 : OK

TX FREQUENCY : 85/215 kHz (or 60/153 kHz)


ROLL MS: 10 SC: _ _ _
PITCH MS: 10 SC: _ _ _
PULSES NG
TRAIN 359 0
TEST COUNT= : 0 REMOTE CONTROL
PANEL

0 0 0 0 0 0 0 0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 0 0 0 0 0 0
0 EXIT
0 0 0 0 0 0
0 0 0 0 0

** Program Version No. 


Test display
 &KHFNWKHIUHTXHQF\DWWKH7;)5(48(1&<OLQHRQWKHWHVWGLVSOD\
 3UHVVWKHMENUNH\VHYHUDOWLPHVWRFORVHWKHPHQX

3-3
$'-8670(17

3.3 Heading Alignment Setting


7KHKHDGLQJOLQHFDQEHFRPSHQVDWHGIURPWKHV\VWHPPHQX ±°WR° 

 /RFDWHDWDUJHW EXR\HWF LQWKHERZGLUHFWLRQDQGGLVSOD\LWRQWKHVFUHHQ
DWFORVHUDQJHUHDGGHYLDWLRQ7KHKHDGLQJDOLJQPHQWLVFRUUHFWZKHQWKH
WDUJHWLVGLVSOD\HGDWR¶FORFNRQWKHVFUHHQ

Heading

Buoy 12 o'clock position

When on-screen target is skewed right,


transducer heading is skewed left.

Checking heading alignment


 3UHVVWKHMENUNH\WRGLVSOD\WKHPHQX
 3UHVVŻŹWRVHOHFW6<6DWWKHWRSRIPHQXGLVSOD\
 3UHVVźWRVHOHFW*2726<6
 3UHVVŻWRVHOHFW<(6WRGLVSOD\WKHV\VWHPPHQX
 3UHVVźWRVHOHFW+($',1*2))6(7'5$)72))6(7DQGWKHQSUHVVŹ
WRGLVSOD\WKHKHDGLQJRIIVHWGLVSOD\
** HEADING OFFSET/DRAFT OFFSET **

HEADING : 0 Û (-180Û - +180Û)


DRAFT : 0.0 Û (0.0 - 60.0m)

: SELECT : CHANGE MENU: END



Heading offset display
 3UHVVŻRUŹWRDOLJQKHDGLQJ ƒVWHS VRWKDWWKHWDUJHWVHOHFWHGDWVWHS
DSSHDUVDWWKHWZHOYHR¶FORFNSRVLWLRQ
 3UHVVźWRFKRRVH'5$)7
 3UHVVŻRUŹWRVHWVKLS¶VGUDIW
3UHVVWKH0(18NH\WZLFHWRFORVHWKHPHQX
&RQILUPWKDWWKHWDUJHWRQKHDGLQJGLUHFWLRQDSSHDUVDWWKHWZHOYHR¶FORFN
SRVLWLRQ

3-4
3. ADJUSTMENT

3.4 Setting for Synchronizing Transmission with


other Equipment
To synchronize transmission with other echo sounder (see paragraph 2.2), do as
follows:

1. Press the MENU key to display the menu.


2. Press Ż to select COM1 at the top of menu display.

MENU COM1 COM2 HORZ VERT ES PRESET SYS

TX POWER MAX
PULSELENGTH LONG
TX RATE 10
INT REJECT OFF
AGC OFF
AUDIO LEVEL 0

: SELECT : CHANGE MENU: END

Menu (COM1)
3. Press ź to select TX RATE.
4. Press Ź to display the setting window.
TX RATE 5
EXT. MIN MAX

(EXT., 1-10)

TX RATE window
5. Press Ż several times to select EXT.
6. Press the MENU key to close the menu.

3-5
$'-8670(17

3.5 Setting for Satellite Compass


)858126DWHOOLWH&RPSDVV6&FDQEHFRQQHFWHGWRIHHG
UROOLQJSLWFKLQJGDWDWRWKLVHTXLSPHQW&RQQHFWWKH6&VHQVRUWRWKH
10($6$7(//,7(&203$66SRUWDQGVHWXSWKLVSRUWDVEHORZ

 3UHVVWKHMENUNH\WRVKRZWKHPHQX
 3UHVVŹWRVHOHFW6<6DWWKHWRSRIPHQXGLVSOD\
 3UHVVźWRVHOHFW*2726<60(18
 3UHVVŻWRVHOHFW<(6WRGLVSOD\WKHV\VWHPPHQX
 3UHVVźWRVHOHFW6<67(06(77,1*

** SYSTEM SETTING 1 **

MENU 1 2
POSITION : SHIP'S L/L SHIP'S LOP CURSOR L/L
TRACK : OFF ON
CURRENT DATA : OFF FLOW FROM FLOW TO
HEADING INDICATION : TRUE AZ
NORTH MARK : OFF ON
CSE DATA : NAV GYRO
NAV DATA : GPS LoranC LoranA DR DECCA OTHERS
NAV2 BAUDRATE : 4800 9600 19200 38400
TVG CORRECTION : OFF 1/2 1/1
UNIT : m ft fa HIRO P/B
TEMP : C F
TARGET L/L : OFF ON
CUSTOM KEY : PRESET KEY SHORT-CUT KEY
ETA MARK : OFF 10sec 30sec 1min 3min 6min

: SELECT : CHANGE MENU: END




System setting 1 menu


 3UHVVźWRVHOHFW1$9%$8'5$7(DQGWKHQSUHVVŹWRVHOHFW
 3UHVVŸWRVHOHFW0(18DWWKHWRSRIWKHPHQXDQGWKHQSUHVVŹWRVHOHFW


3-6
$'-8670(17

** SYSTEM SETTING 2 **
MENU : 1 2

GAIN SETTING PROTECT : OFF ON


HORZ/HISTORY : OFF ON
HORZ/VERT ZOOM : OFF ON
HORZ/PLOTTER : OFF ON
EMPHASIS MODE : OFF NORMAL RED
STABILIZER : OFF MOTION SENSOR SAT. COMPASS
AUTO RETRACTION : OFF (OFF, 5-15 kt)
SPEED ALARM/MESSAGE : OFF ON
SWEEP INDICATOR : DOT LINE
DEFAULT SETTING : NO YES
MAXIMUM ALLOWABLE SPEED IS 15 KNOTS WHILE SOUNDOME IS BEING
RETRACTED. IF VESSEL HAS REPAID ACCELERATION CAPABILITIES,
AUTO RETRACTION SETTINGS OF 10-12 KNOTS ARE MANDATORY TO
AVOID CATASTROPHIC DAMAGE TO SOUNDOME ASSY. ANY PHISICAL
DAMAGE TO THE SOUDOME ASSY. IS CONSIDERED ABUSE AND
IS NOT A WARRANTY ISSUE.

: SELECT : CHANGE MENU: END




System setting 2 menu


 3UHVVźWRVHOHFW67$%,/,=(5
 3UHVVŹWRVHOHFW6$7&203$66
3UHVVWKHMENUNH\WZLFHWRFORVHWKHPHQX

Note:7RRXWSXWGDWDIURP6&LQ10($IRUPDWVHWWKH6&DV
IROORZV
2XWSXWIRUPDW,(&HG
6HQWHQFH$77 )RURWKHUVVHWDOO2)) 
%DXGUDWHESV
&\FOHPV
7DONHUDQ\ 

Note::KHQFRQQHFWLQJWKHDQDORJVLJQDORI6DWHOOLWH&RPSDVV6&WRWKH
027,216(1625SRUWRQWKHWUDQVFHLYHUXQLWFKRRVH027,21
6(1625DWVWHSLQWKHDERYHSURFHGXUH)RUZLULQJGHWDLOVVHHWKH
LQWHUFRQQHFWLRQGLDJUDPDWWKHEDFNRIWKLVPDQXDO

3-7
3. ADJUSTMENT

3.6 Setting of Motion Sensor/Satellite Compass


When connecting the motion sensor, clinometer or satellite compass, enter
ship’s roll and pitch angles as shown below. Note that the adjustment can be
done only when connected to the MOTION SENSOR port. For the satellite
compass, however, do not duplicate this adjustment; enter values at one location
only.

1. Press the MENU key to display the user menu.


2. Press to Ź select SYS at the top of the menu display.
3. Press ź to select GO TO SYS.
4. Press Ż to select YES.
5. Press ź to select ADJ MOTION SENSOR, and then press Ź to display the
ADJ MOTION SENSOR menu.
** ADJ MOTION SENSOR **

ROLL ANGLE: 0˚ ADJ: +5* ˚ (-10˚ - +10˚)


PITCH ANGLE: 0˚ ADJ: +5* ˚ (-10˚ - +10˚)

: SELECT : CHANGE MENU: END

*: For Clinometer BS-704, tilt angle is displayed. For Motion Sensor MS-100,
the readout is "0" (zero) when the ship is stopped, regardress of actual roll or pitch.

Adj motion sensor menu


6. Press Ÿ or ź to select ROLL ANGLE or PITCH ANGLE.
7. Press Ż or Ź to adjust (-10° to +10°).
8. For MS-100, use a clinometer or other similar measuring device to measure
ship’s semi-permanent inclination angle. Take the polarity of the angle. For
example, if the stern is 3° down, set -3°.

+ – + –
0 0

+ -
ROLL ANGLE Starboard up Starboard down
PITCH ANGLE Stern up Stern down
For clinometer BS-704, adjust so that the indication shows “0” (zero).
9. Press the MENU key several times to close the menu.

3-8
$'-8670(17

3.7 System Back Up


$IWHUVHWWLQJXSWKHHTXLSPHQWIROORZWKHSURFHGXUHEHORZWREDFNXSV\VWHP
VHWWLQJV%DFNXSGDWDFDQEHORDGHGLQWKHHYHQWRIHTXLSPHQWWURXEOHWRUHVWRUH
SUHYLRXVV\VWHPVHWWLQJV

 3UHVVWKHMENUNH\WRGLVSOD\WKHXVHUPHQX
 3UHVVŹWRVHOHFW6<6DWWKHWRSRIWKHPHQX
 3UHVVźWRVHOHFW*2726<60(18
 3UHVVŻWRVHOHFW<(6
 7KHV\VWHPPHQXDSSHDUV
 3UHVVźWRVHOHFW6<67(0%$&.83
 3UHVVŹWRGLVSOD\WKHV\VWHPEDFNXSPHQX
** SYSTEM BACK UP**

ARE YOU SURE? : NO YES

NOTE: OVERWITES PREVIOUS BACKUP DATA

: CHANGE MENU: END




System backup menu


 3UHVVŹWRVHOHFW<(6
 3UHVVWKHMENUNH\WREDFNXSGDWD
 7KHEDFNXSGDWDLVVDYHGDQGWKHQUHWXUQWRWKH6\VWHPPHQX
 3UHVVWKHMENUNH\WRUHWXUQWRWKHQRUPDOGLVSOD\

3-9
$'-8670(17

3.8 Setting of Interface Unit


6HW',3VZLWFK6LQWKHLQWHUIDFHXQLWDVIROORZV
• $XQLWLVFRQQHFWHGWR'$7$9,'(2287SRUWRIWKHLQWHUIDFHXQLWDOO2))
• 1RWKLQJLVFRQQHFWHGWR'$7$9,'(2287SRUWRIWKHLQWHUIDFHXQLWDOO21

THROUGH

BUFFER
J6* J7*
S1 ON
OFF
J1 J2 J3

*: J6 and J7 set to "THROUGH" side. 

Interface unit, DIP switch S1 location

External
Monitor

Processor Interface Monitor


Unit Unit Unit

S1:All OFF

External
Monitor

Processor Interface
Unit Unit

S1:All ON

External External
Monitor Monitor

Processor Interface Interface


Unit Unit Unit

S1:All OFF S1:All ON 

3-10
APPENDIX 1 HOW TO MAKE THE
RETRACTION TANK FOR WOODEN VESSEL
These instructions show how to make the retraction tank for a wooden vessel.

Retraction tank (conceptual drawing)

Necessary components for the retraction tank


Prepare the components shown in the table below for the retraction tank. The dimensions in the
table are recommended values. Follow the recommended values as near as possible.

Name Material Thickness Qty Remarks


PVC pipe PVC-U More than 1 8inch PN13.5
13 mm Inside diameter: 188.5 - 195 mm
Use the VP type.
Prepare the thread groove that is suitable for
the outside diameter.
1200
≥ 13

96 (M215x4)
91
C4
Ø190 -1.5
+5
(Ø216)

Ø208

AP-1
APPENDIX 1 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

Name Material Thickness Qty Remarks


Flange-1 SS400 More than 1 Inside diameter: Same as the outside diame-
20.0 mm ter of the fixing pipe.
Outside diameter: 343 mm
C1 C1
8 × Ø23

45°
22.5°
Ø297±0
䋨Ø230䋩
.3
Ø343

Fixing pipe SS400 More than 1 Inside diameter: 10 mm smaller than the out-
7.0 mm side diameter of the PVC pipe.
Prepare the thread groove that is suitable for
the thread groove of the PVC pipe.
(232)
≥7
C1

(M215x4)
100
20

C3
(230)

Angle-1 SUS304-CP 4.0 mm 4 Welded to the flange-1.

42 6 42
R1
(4)

26
42

26
Drill the pilot holes for the M12 nut (Ø15,
2 locations), then weld the hex. weld nuts.
60
42

AP-2
APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

Name Material Thickness Qty Remarks


Flange-2 SS400 More than 1 Inside diameter: Max. 259 mm,
12.0 mm Min. Pipe O.D + 20 mm
Outside diameter: 343 mm
45°
C1 C1 22.5°
8 × Ø14

Ø259 ≥ I.D ≥ Pipe O.D + 20


Ø297±0
.3
Ø343

I.D: Inside diamater


Pipe O.D: Outside diameter of the PVC pipe

Angle-2 SUS304-CP 4.0 mm 4 Welded to the flange-2.

42 35
6
(4)

R1

26
42

Ø14 × 30 long hole


26
Prepare the long holes for the bolt
(Ø14 × 30, 2 locations)
60
35

Fixing plate SUS304-CP 4.0 mm 4 The equal angle iron (L50 x t4.0) is also
available.
235 32.5

(4)
Prepare the long holes for the bolt
(Ø14 × 30, 4 locations)
50
30

50 R4 - 6

AP-3
APPENDIX 1 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

Welding the component


Before assembling the retraction tank, weld the components to create the flange assembly 1 and
2.

• Flange assembly 1
Weld the fixing pipe and four angle-1 to the flange-1. After welding, mask the thread groove of the
fixing pipe, then apply anticorrosive coating to the flange assembly 1.
Welding area (4 locations) (80)
45° 4 Welding bead must be 62
within the welding area.
(42)

8 × Ø23 45°

Flange-1 22.5°

Ø297±0

(194)
.3

246
A A

246 Angle-1

C
1
(232)

1
C1
Angle-1 B
M M215 × 4
Masking area

100

60°
6
Flange-1 8
20

C3 (Ø230)
0.2 B Ø343 Ra 3.2
A-A

• Flange assembly 2
Weld four angle-2 to the flange-2.
(72)
47
(12) (35)
45° 45°
22.5°
1
C

C
1

A 8×Ø14
Angle-2

Flange-2

Ø297±0
(194)

.3
Ø244
Ø343

246

Welding area (4 locations)


4 Welding bead must be
within the welding area.
A
A-A
246

AP-4
APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

How to assemble the retraction tank


To assemble the retraction tank, prepare the installation materials shown in the table below.

Name Material Type Qty


Hex. bolt SUS304 M12×20 -25 8
SUS304 M12×25 or more 8
Hex. nut SUS304 M12 8
Spring washer SUS304 M12 16
Flat washer SUS304 M12 24

1. Fix four fixing plates to the flange assembly 1.

Detailed view

Fixing plate
Spring washer

Hex. bolt*
䋨M12×20 - 25䋩
Hex. weld nut Flat washer

Angle-1 Fixing plate

Flange assembly 1 *: Length of bolt should be such that bolt does


not interfere with other bolts when tightened.

2. Fix the flange assembly 2 to the component assembled at step 1.


Tighten the bolts temporarily to allow for fine adjustment later.

Detailed view
Insert the hex. bolt from the inside (angle-2
side), then tighten the hex. nut from the outside.

Angle-2
Fixing plate
Flat washer Spring washer

Hex. bolt
䋨M12×25 or more䋩
Hex. nut
Flat washer

Flange assembly 2

AP-5
APPENDIX 1 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

3. Apply the silicone sealant to the threads of the PVC pipe, then screw the PVC pipe into
the flange assembly.

PVC pipe
Flange
asssembly
Apply the silicone sealant
to the threads.

4. To prevent water from entering at the threads, fill the clearance between the flange
assembly and PVC pipe with the silicone sealant.
Cross-section view:
Fill this area with the silicone application area
silicone sealant.
Apply the silicone sealant so that
the it does not go over the top
surface of the flange.
Silicone

Flange assembly
PVC pipe

AP-6
APPENDIX 2 HOW TO INSTALL THE
RETRACTION TANK FOR WOODEN VESSEL
Install the retraction tank for wooden vessel (prepared in Appendix1) as shown here.

Installation location considerations


Discussion and agreement are required with the dockyard and ship owner in deciding the location
for the retraction tank (hull unit). When selecting the installation location, consider the following
points:
• Select an area where the noise and interference are minimal.
The point at 1/3 to 1/2 of the ship’s length from the bow or near the keel is the best. The center
of the retraction tank should be within 1 meter of the keel to prevent a rolling effect.
• Install the retraction tank off the keel.
Do NOT install the retraction tank on the keel and mounting hole for the retraction tank should
not be contact with the keel.

Retraction tank

Mounting range 1/3 Keel


1/2 Within 1 m
• Select a place where interference from the transducers of other equipment is minimal.
The hull unit should be at least 2.5 meters away from the transducers of other sounding equip-
ment.
• Select a place where no obstruction should be around the full-lowered transducer.
No obstruction should be in the fore direction since it causes a shadow zone and aerated
water, resulting in poor sonar performance.
• The distance between the bottom line of the keel and retraction tank should be 50 mm.
When the distance between the bottom line of the keel and retraction tank is more than 50 mm,
the echo beam may be interrupted with the keel or other ship’s bottom structures.

Keel
≥ 50

Bottom line of the retraction tank


Bottom line of the keel

Echo beam area


≤ 1000
• Install a flow rectification component to the hull where the transducer projects.
Install a fairing or stainless plate as the flow rectification component. See the next page to
select a faring or stainless plate.

AP-7
APPENDIX 2 HOW TO INSTALL THE RETRACTION TANK FOR WOODEN VESSEL

Selection of the flow rectification component


According to the vertical distance between the bottom line of the keel and center of the retraction
tank, select a fairing or stainless plate as the flow rectification.

Retraction tank

Keel
A < 50 mm: Select a stainless plate
A ≥ 50 mm: Select a wooden fairing
A

≤ 1000

Recommended dimensions for the stainless plate


• Length (bow-stern direction): R. P + 20 mm or more
• Length (both sides direction): Pipe O.D + 100 mm or more
• Thickness (T): 10 mm or more
• Diameter of the hole: Pipe I.D + 1 mm
Note: For flat bottom hull, prepare a wooden reinforcement block to decrease the vibration of the
retraction tank. The recommended dimensions of the reinforcement block are shown below.
Recommended dimensions for the reinforcement block
• Height: 300 mm or more
• Length (bow-stern direction): Same as the distance between the ribs
• Length (both sides direction): Pipe O.D + 100 mm or more
• Diameter of the hole: Pipe O.D + 1 mm
≥ Pipe O.D + 100
㪧㫀㫇㪼㩷㪦㪅㪛
㪧㫀㫇㪼㩷㪠㪅㪛
R.P: Rib pitch
Reinforcement block Pipe I.D: Inside diameter of the PVC pipe
Pipe O.D: Outside diameter of the PVC pipe
≥ 300

Keel
Pipe O.D + 1

≥ Pipe O.D + 100 Rib


≥ R.P + 20
R. P

Rib 1
D+
i p e I.
Ø P

Stainless T ≥ 10 Rib
plate

AP-8
APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

Recommended dimensions for the faring


• Length (bow-stern direction): R. P + 100 mm or more (700 mm or more recommended)
• Length (both sides direction): Pipe O.D + 100 mm or more
• Diameter 1: Pipe O.D + 1 mm
• Diameter 2: Pipe I.D + 1 mm
• Distance between the bottom lines of the fairing and PVC pipe: 30 mm
Note1: Be sure the fairing does not interfere with the raising or lowering of the transducer.
Note2: Streamline the fairing to keep water pressure and bubbles minimal.
Note3: If the height of the fairing is less than 300 mm, install a wooden reinforcement block on the
inside of the hull.

Pipe O.D
Pipe I.D

Reinforcement block
Fairing
≥ 50

≥ 300
30
Keel
≤ 1000
Diameter 2
Diameter 1

≥ Pipe O.D + 100

Keel
Rib Rib

Rib
R. P

≥ 700

Rib Rib

≥ 300 ≥ 300

Case 1 Case 2
R.P: Rib pitch (No reinforcement block) (With reinforcement block)
Pipe I.D: Inside diameter of the PVC pipe
Pipe O.D: Outside diameter of the PVC pipe

AP-9
APPENDIX 2 HOW TO INSTALL THE RETRACTION TANK FOR WOODEN VESSEL

Mounting hole and installation of the flow rectification component


1. Select the installation location referring to “Installation location considerations“ (AP-7
page).
For the location of the mounting hole, consider the following points:
• Make the mounting hole between ribs.
• The mounting hole should not be across the hull plates of the vessel.
OK WRONG
Hull plate

Mounting
hole
Mounting hole is at the Mounting hole is
Hull
center of the hull plate. across the hull plates.

2. Install the flow rectification component (fairing or stainless plate) on the ship’s hull.
Be sure the bolts penetrate through the ribs or wooden reinforcement block.
3. Apply the adhesive to the area between the ship’s hull and flow rectification component
for waterproofing.
Apply the adhesive evenly to provide smooth water flow around the flow rectification
component.
For the fairing

Reinforcement block
: Adhesive application area
Rib
Hull plate

Adhesive:
The water flow around the
rectification component Fill the bolt holes with the adhesive.
must be smooth.
Fairing

For the stainless plate

Reinforcement block : Adhesive application area


Rib
Hull plate

Adhesive:
The water flow around the Apply the adhesive
rectification component around the bolts.
must be smooth. Stainless
plate

4. Open a mounting hole in the hull and flow rectification component perpendicular to the
waterline.

AP-10
APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

Installation of the tank reinforcement structure


Install the tank reinforcement structure to prevent the retraction tank from coming off and vibrating.
Fix the tank reinforcement structure to the ribs or ship’s superstructure.
Tank reinforcement structure

Rib

Rib

Tank reinforcement structure (conceptual drawing)

Create the tank reinforcement structure considering the structure of the hull. The minimum dimen-
sions of the tank reinforcement structure are shown below. Ensure the reinforcement structure
meets the minimum dimensions or better.
To fasten and assemble the tank reinforcement structure, use the M10 (or more) bolts.

≥ 100 Rib
≥ 700
≥ 700

Ø
Pip

≥ 100
eO
.D

≥ 100
+1

≥ 100 ≥ 100

Note: Make the bolt holes for the tank reinforcement structure so that the center of any two bolt
holes is facing the ship’s bow.

Bow
αβ
α= β

AP-11
APPENDIX 2 HOW TO INSTALL THE RETRACTION TANK FOR WOODEN VESSEL

How to install the retraction tank


1. Set the retraction tank to the tank reinforcement structure and mounting hole.
2. Loosen the bolts fixing the flange (8 locations, 16 pcs.), then adjust the flange of the
retraction tank so that it is parallel with the waterline.
Level gauge: Retraction tank
Set a level gauge on the
retraction tank. Adjust the flange
of the retraction tank so that it is
parallel with the waterline.

Tank reinforcement structure

3. Fasten the bolts that are loosened at step 2.


4. Mark a line on the location on the retraction tank and tank reinforcement structure that
points toward the ship’s bow.

Mark the line that points


toward ship's bow.
Bow

5. Pull out the retraction tank.


6. Sand the retraction tank (PVC pipe) with a grinder to increase waterproofing and adhe-
sion.
Sand the adhesion area on the
hull and flow rectification
component.

Retraction tank
(PVC pipe)

AP-12
APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL

7. Use a hair dryer or the like to dry the mounting hole, then apply the adhesive to the con-
tact areas between the retraction tank and mounting hole.
Apply the adhesive both to the retraction tank and mounting hole.
8. Set the retraction tank to the tank reinforcement structure and mounting hole to align the
line marked at step 4.
After setting the retraction tank, remove the adhesive run over the mounting hole.
Retraction tank
(PVC pipe)

Reinforcement block

Hull plate

: Adhesive application area


Flow rectification component
䋨Fairing or stainless plate)

9. Fasten the retraction tank to the tank reinforcement structure with eight hex. bolts
(M12).
Hex. bolt (M12)
Detailed view

Washer Hex. bolt


Flange Washer

Tank reinforcement structure

Washer
Hex. nut

Washer
Hex. nut

10. Confirm that the flange of the retraction tank is parallel with the waterline.

AP-13
APPENDIX 2 HOW TO INSTALL THE RETRACTION TANK FOR WOODEN VESSEL

This page is intentionally left blank.

AP-14
#8:   #8:  
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
%*/7% A-1 %*'%*' A-2

0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;


࡙࠾࠶࠻ 70+6 ࡙࠾࠶࠻ 70+6
ᠲ૞⴫␜ㇱ ᠲ૞ㇱ
%*/7%  %*' 
%10641.&+52.#;70+6 %10641.70+6
 
੍஻ຠ 52#4'2#465 52 ઃዻຠ #%%'5514+'5 (2
੍஻ຠ 㩔㨺㩎㩨㩀㩔㩨㨺
52  41*5 
52#4'2#465 &+52.#;%18'4
 
ઃዻຠ #%%'5514+'5 (2 ઃዻຠ
㩖㨺㩎㩨㩂㩚㩕㩧 
(2
 #%%'5514+'5
(2
*11&#55; 
 Ꮏ੐᧚ᢱ +056#..#6+10/#6'4+#.5
ઃዻຠ 㩃㨺㩖㩨㩣⚵ຠ/, /,#52(
(2  /,#52( 
$4#%-'6#55'/$.; %#$.'#55;


 
Ꮏ੐᧚ᢱ +056#..#6+10/#6'4+#.5 %2 㩃㨺㩖㩨㩣⚵ຠ/, /,#52(
㩃㨺㩖㩨㩣⚵ຠ/, /,#52( 
/,#52(
 %#$.'#55;
/,#52( 

%#$.'#55; 



䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫ဳᑼ㪆䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯 㩿㪁㪀ශ䈱䍗㪄䍪䍼䍷⚵ຠ䈲઀᭽䈮䉋䉍᳿ቯ䈘䉏䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 㩿㪁㪀㩷㪤㪘㪩㪢㪜㪛㩷㪚㪘㪙㪣㪜㪪㩷㪘㪩㪜㩷㪪㪜㪣㪜㪚㪫㪘㪙㪣㪜㪅

ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅

䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%<$ %<%
06AS-X-9854 -0 1/1 06AV-X-9854 -2 1/1
PACKING LIST A-3 PACKING LIST A-4
IF-8000 CH-303-J/E
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT ユニット UNIT
インターフェイスユニット IF-8000 送受信装置 CH-303
1 1
INTERFACE UNIT TRANSCEIVER UNIT
000-068-487 000-068-631
予備品 SPARE PARTS 予備品 SPARE PARTS
予備品 SP06-01111 予備品 SP06-01102
1 1
SPARE PARTS SPARE PARTS
006-556-220 006-556-210
工事材料 INSTALLATION MATERIALS
工事材料 CP06-01261
1
INSTALLATION MATERIALS
006-562-580
図書 DOCUMENT
取扱説明書(和) OMJ-13250-*
1
OPERATOR'S MANUAL
000-151-899 **

装備要領書(和) IMJ-13250-*
1
INSTALLATION MANUAL
000-151-901 **

コ-ド番号末尾の[**]は、選択品の代表型式/コー ドを表します。
C O D E N U M B ER EN D IN G W ITH "**" IN D IC A TES TH E C O D E N U M B ER O F R EP R ES EN TA TIV E M A TER IA L.

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


C1316-Z04-A (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1325-Z04-C
06AV-X-9855 -4 1/1 06AV-X-9858 -2 1/1
PACKING LIST A-5 PACKING LIST A-6
CH-3041-* CH-3051-*
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT ユニット UNIT
上下動部組品 CH-3041* 上下動部組品 CH-3051*
1 1
RAISE/LOWER DRIVE UNIT RAISE/LOWER DRIVE UNIT
006-561-250 ** 006-560-920 **
予備品 SPARE PARTS 予備品 SPARE PARTS
予備品 SP06-01103 予備品 SP06-01103
1 1
SPARE PARTS SPARE PARTS
006-558-990 006-558-990
工事材料 INSTALLATION MATERIALS 工事材料 INSTALLATION MATERIALS
工事材料 CP06-01501 工事材料 CP06-01501
1 1
INSTALLATION MATERIALS INSTALLATION MATERIALS
006-561-620 006-561-620

コ-ド番号末尾の[**]は、選択品の代表コー ドを表します。 コ-ド番号末尾の[**]は、選択品の代表コー ドを表します。


C O D E N U M B ER EN D IN G W ITH "**" IN D IC A TES TH E C O D E N U M B ER O F R EP R ES EN TA TIV E M A TER IA L. C O D E N U M B ER EN D IN G W ITH "**" IN D IC A TES TH E C O D E N U M B ER O F R EP R ES EN TA TIV E M A TER IA L.

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1325-Z05-D C1325-Z08-B
A-7 A-8
%1&'01 #5:  CODE NO. 006-556-630-00 06AS-X-9401 -2
6;2'  TYPE CP06-01251 1/1

Ꮏ੐᧚ᢱ⴫ 工事材料表
%*5‫ޔ‬%*
+056#..#6+10/#6'4+#.5 INSTALLATION MATERIALS
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ 番 号 名  称 略  図 型名/規格 数量 用途/備考
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
㩃㨺㩖㩨㩣
㩂㩚㩕㩧 ㆬᛯ‫ޓ‬61$'5'.'%6'& 圧着端子
 5 /  1 FV2-4
%#$.'#55'/$.; CRIMP-ON LUG 8
%1&'01 CODE
 NO. 000-157-247-10
㩃㨺㩖㩨㩣
㩂㩚㩕㩧 ㆬᛯ‫ޓ‬61$'5'.'%6'&
 5 / 
%#$.'#55'/$.;
%1&'01

㩃㨺㩖㩨㩣
⚵ຠ ㆬᛯ‫ޓ‬61$'5'.'%6'&
 5 / 
%#$.'#55'/$.;
%1&'01

㩃㨺㩖㩨㩣
㩂㩚㩕㩧 ㆬᛯ‫ޓ‬61$'5'.'%6'&
 5 / 
%#$.'#55'/$.;
%1&'01

㩃㨺㩖㩨㩣
㩂㩚㩕㩧 ㆬᛯ‫ޓ‬61$'5'.'%6'&
 5 / 
%#$.'#55'/$.;
%1&'01


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
37#.+6;+56*'5#/' PRODUCT. QUALITY IS THE SAME.
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 FURUNO ELECTRIC CO .,LTD.
%/( C1316-M01-C
A-9 A-10
&2'(12  $6;  CODE NO. 006-561-620-00 06AV-X-9401 -5
7<3( &3  TYPE CP06-01501 1/1

ᕤ஦ᮦᩱ⾲ 工事材料表
,167$//$7,210$7(5,$/6 INSTALLATION MATERIALS
␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃ 番 号 名  称 略  図 型名/規格 数量 用途/備考
12 1$0( 287/,1( '(6&5,37,216 4
7< 5(0$5.6 NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
㺢㺵㺛㺞㺍㺩㺽㺻㺦㺚㺼㺚㺋 コンベックス
 ;686㺖㺹  1 CV-100N 2
6(/)7$33,1*6&5(: CABLE TIE
&2'( CODE
12  NO. 000-162-167-10
ᅽ╔➃Ꮚ 圧着端子
 )9%/8.  2 FV2-4 BLU K 4
&5,0321/8* CRIMP-ON LUG
&2'( CODE
12  NO. 000-157-247-11
EMIコア
3 RFC-4 1
EMI CORE
CODE
NO. 000-161-849-10

㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂 FURUNO ELECTRIC CO .,LTD.

M M E
A-11 A-12
CODE NO. 001-413-590-00 02FJ-X-9508 -3 CODE NO. 006-556-260-00 06AS-X-9501 -7
TYPE FP02-05101 1/1 TYPE FP06-01120 1/1

付属品表 付属品表
ACCESSORIES ACCESSORIES
番 号 名  称 略  図 型名/規格 数量 用途/備考 番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
トリツケダイ 02-127-1301-1 ROHS 操作取付台
1 02-127-1301-1 1 06-021-2111-1 1
MOUNTING BASE 1 ONTROL UNIT MOUNTING
CODE 100-285-141-10 BASE CODE
NO. 100-285-141-00 NO. 100-279-741-10
ハンガー 02-127-1302-1 ROHS ソウサブラケット
2 02-127-1302-1 2 06-021-2112-0 ROHS 1
BRACKET 1 CONTROL UNIT BRACKET
CODE 100-285-151-10 CODE
NO. 100-285-151-00 NO. 100-281-880-10
+トラスタッピンネジ 1シュ +トラスタッピンネジ 1シュ
3 5X20 SUS304 3 5X20 SUS304 2
SELF-TAPPING SCREW 4 SELF-TAPPING SCREW
CODE CODE
NO. 000-162-608-10 NO. 000-162-608-10
+バインドセムスF ホールプラグ
4 M4X10 C2700W MBCR2 ヒラ 4 DP-687 クロ 2
WASHER BINDING 4 COSMETIC PLUG
HEAD SCREW CODE CODE
NO. 000-163-543-10 NO. 000-165-997-10
+アプセットUIセムスB 六角スリワリ セムスB
5 M6X16 SUS304 5 M4X12 SUS304 4
+HEX.BOLT 2 HEX.BOLT
CODE (SLOTTED,WASHER CODE
NO. 000-163-758-10 HEAD) NO. 000-162-939-10

型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。 ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME. PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
FURUNO ELECTRIC CO .,LTD. FURUNO ELECTRIC CO .,LTD.
C2365-F08-D C1316-F01-H
A-13 A-14
&2'(12  $6;  
7<3( 63 %2;123 CODE NO. 006-556-210 06AS-X-9302 -2 1/1
6(763(5 TYPE SP06-01102 BOX NO. P
6+,312 63$5(3$576/,67)25 86( 9(66(/ SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL

48$17,7< 5(0$5.6&2'(12
':*12
,7(0 1$0(2) :25.,1*
287/,1( 25
12 3$57 DWG. NO. QUANTITY REMARKS/CODE NO.
7<3(12 3(5 3(5 63$5(
6(7 9(6 ITEM NAME OF OR WORKING
NO. PART OUTLINE
TYPE NO. PER PER SPARE
㺩㺋㺎㺛㺼
SET VES
 */$6678%(   
)86( )*0%$9 ヒュ-ズ FGMB 125V
$3%) 10A PBF
 1 3
FUSE

000-157-470

0)5
61$0( )85812(/(&75,&&2/7' ':*12 &3( 

㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*ࠉ)255()(5(1&(21/<㸧 MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 1/1


C1316-P02-C
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-15 A-16
CODE NO. 006-558-990 06AS-X-9304 -2 1/1 CODE NO. 006-556-220 06AS-X-9303 -4 1/1
TYPE SP06-01103 BOX NO. P TYPE SP06-01111 BOX NO. P
SETS PER SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL SHIP NO. SPARE PARTS LIST FOR U S E VESSEL

DWG. NO. QUANTITY REMARKS/CODE NO. DWG. NO. QUANTITY REMARKS/CODE NO.
ITEM NAME OF OR WORKING ITEM NAME OF OR WORKING
NO. PART OUTLINE NO. PART OUTLINE
TYPE NO. PER PER SPARE TYPE NO. PER PER SPARE
SET VES SET VES

ヒューズ FGMB 125V 7A ヒューズ FGMB 125V


PBF 0.2A PBF
1 FUSE 1 3 1 FUSE 3
FGMB 7A 125V 000-157-493-10 FGMB 0.2A 125V 000-157-457-10
000-105-868-00 000-121-723-00

MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. C1316-P04-C 1/1 MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. C1316-P03-D 1/1

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変
わりません。 わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE
UPPER PRODUCT. QUALITY IS THE SAME. UPPER PRODUCT. QUALITY IS THE SAME.
$6;  
㹎㸿㹁㹉㹇㹌㹅ࠉ㹊㹇㹑㹒
&+$ 06AV-X-9856 -2 1/1
A-17 PACKING LIST A-18
1$0( 287/,1( '(6&5,37,21&2'(θ 4
7< CH-3042-*/CH-2542-*
⌧ᆅ⤌㒊ရ /2&$/$66(0%/,1*ࠉ3$576
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
㺝㺣㺎㺓㺐㺷
ユニット UNIT
㺶㺍㺢㺷㺔㺻 
621$52,/ 旋回俯仰部 CH-3042-*/CH-2542-*
 1
COMPLETE SOUNDOME ASSEMBLY
㺪㺵㺻㺚㺼 006-561-500 **
&+ 
0$,1%2'<)/$1*($66(0%/<

⌧ᆅ⤌❧ࢭࢵࢺ⟽ワ
&+ $ 
+8//81,7$66(0%/<3$576


コ-ド番号末尾の[**]は、選択品の代表型式/コー ドを表します。
䡶㻙䢀䢚␒ྕᮎᑿ䛾㼇㻖㻖㼉䛿䚸㑅ᢥရ䛾௦⾲䡶䡬䢀䢚䜢⾲䛧䜎䛩䚹 C O D E N U M B ER EN D IN G W ITH "**" IN D IC A TES TH E C O D E N U M B ER O F R EP R ES EN TA TIV E M A TER IA L.
㻯㻻㻰㻱㻌㻺㼁㻹㻮㻱㻾㻌㻱㻺㻰㻵㻺㻳㻌㼃㻵㼀㻴㻌㻎㻖㻖㻎㻌㻵㻺㻰㻵㻯㻭㼀㻱㻿㻌㼀㻴㻱㻌㻯㻻㻰㻱㻌㻺㼁㻹㻮㻱㻾㻌㻻㻲㻌㻾㻱㻼㻾㻱㻿㻱㻺㼀㻭㼀㻵㼂㻱㻌㻹㻭㼀㻱㻾㻵㻭㻸㻚

䠄␎ᅗ䛾ᑍἲ䛿䚸ཧ⪃್䛷䛩䚹㻌㻌㻰㻵㻹㻱㻺㻿㻵㻻㻺㻿㻌㻵㻺㻌㻰㻾㻭㼃㻵㻺㻳㻌㻲㻻㻾㻌㻾㻱㻲㻱㻾㻱㻺㻯㻱㻌㻻㻺㻸㼅㻚䠅

&=& (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


C1325-Z06-C
A-19 A-20
&2'(12  $9;  &2'(12  $9; 
7<3( &+  7<3( 
&+$
フランジ組部品
⌧ᆅ⤌㒊ရ ᕤ஦ᮦᩱ⾲
/2&$/$66(0%/,1*3$576
FLANGE ASSEMBLING
PARTS ,167$//$7,210$7(5,$/6
␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃ ␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃
12 1$0( 287/,1( '(6&5,37,216 4
7< 5(0$5.6 12 1$0( 287/,1( 4
7<
'(6&5,37,216 5(0$5.6
2㺶㺻㺖㺼 3 ᯫྎ㍕ࡏྎ࡟⿦╔ 㺨㺽㺐㺪㺽㺕㺊㺍㺪㺽
ࠉ35($77$&+('72
 &2$ 3  )/$1*($66<  6+152+6
25,1* 3 3,3(&$3 
&2'( &2'(
12  12 
2㺶㺻㺖㺼 $6 ᯫྎ㍕ࡏྎ࡟⿦╔ 㺚㺼㺋㺩㺼㺶㺎㺖㺶㺍㺪㺽
ࠉ35($77$&+('72
 &2$  )/$1*($66<  ;686
25,1* $6 )$67(1,1*%$1' 
&2'( &2'(
12  12 
㺢㺵㺤㺓㺻㺩㺽㺻 ᯫྎ㍕ࡏྎ࡟⿦╔ භゅ㺬㺼㺷㺢
ࠉ35($77$&+('72
 52+6  )/$1*($66<  0;686
75811,213,1 +(;%2/7 
&2'( &2'(
12  12 
㺖㺼㺶㺛㺘㺍㺢㺻ᢲ࠼ྎ ᯫྎ㍕ࡏྎ࡟⿦╔ 8㺣㺍㺢
ࠉ35($77$&+('72
 52+6  )/$1*($66<  0686
*5($6(&27721&29(5 8187 
&2'( &2'(
12  12 
㺪㺵㺻㺚㺼㺪㺼㺍㺚㺋 ᯫྎ㍕ࡏྎ࡟⿦╔ 㺮㺔㺼㺕ᖹᗙ㔠
ࠉ35($77$&+('72
 )  )/$1*($66<  0686
)/$1*(%86+ )/$7:$6+(5 
&2'( &2'(
12  12 
㺪㺵㺻㺚㺼㺨㺽㺍㺕㺻 ᯫྎ㍕ࡏྎ࡟⿦╔ 㺞㺻㺖㺔㺼㺐㺢㺼⤌ရ
ࠉ35($77$&+('72
 6+-52+6  )/$1*($66<  &+
*$6.(7 7$1.*8,'($66(0%/< 
&2'( &2'(
12  12 
㺖㺼㺶㺛㺘㺍㺢㺻㺨㺶㺭㺎㺖 ᯫྎ㍕ࡏྎ࡟⿦╔ භゅ㺬㺼㺷㺢඲㺦㺚㺼
ࠉ35($77$&+('72
 6+1  )/$1*($66<  0;686
*5($6(&277216($/ +(;%2/7 
&2'( &2'(
12  12 
㺖㺼㺵㺻㺢㺼㺨㺽㺍㺕㺻 ᯫྎ㍕ࡏྎ࡟⿦╔ භゅ㺣㺍㺢㺚㺋
ࠉ35($77$&+('72
 9/㺔㺖 0  )/$1*($66<  0686
*/$1'3$&.,1* +(;187 
&2'( &2'(
12  12 
%(1&+6853257 㺮㺔㺼㺕୸ᖹᗙ㔠
    0686
ᯫྎ㍕ࡏྎ )/$7:$6+(5 
&2'( &2'(
12  12 
㺨㺼㺦ᗙ㔠
 0686 
635,1*:$6+(5
&2'(
12 

㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧
㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧

㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂 㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂
&0- &0/ 
A-21 A-22
&2'(12  $9;  &2'(12  $9; 
7<3( &+$  7<3( &+1 

ᕤ஦ᮦᩱ⾲ ᕤ஦ᮦᩱ⾲
,167$//$7,210$7(5,$/6 ,167$//$7,210$7(5,$/6
␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃ ␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃
12 1$0( 287/,1( '(6&5,37,216 4
7< 5(0$5.6 12 1$0( 287/,1( '(6&5,37,216 4
7< 5(0$5.6
㺕㺧㺵㺛㺞 㺨㺽㺐㺪㺽㺕㺊㺍㺪㺽
  *㺐㺶   6+152+6 
$17,&25526,9(6($/$17 3,3(&$3
&2'( &2'(
12  12 
ᾮ≧㺔㺼㺛㺗㺍㺢 㺚㺼㺋㺩㺼㺶㺎㺖㺶㺍㺪㺽
 7%*   ;686 
/,48,'*$6.(76 )$67(1,1*%$1'
&2'( &2'(
12  12 
㺚㺎㺷㺙㺼㺐 භゅ㺬㺼㺷㺢
 㺹㺍㺖㺞㺐㺢12 0/   0;686 
6($/$17 +(;%2/7
&2'( &2'(
12  12 
㺬㺼㺎㺷㺸㺻㺟 8㺣㺍㺢
 7:%   0686 
%$//:5(1&+ 8187
&2'( &2'(
12  12 
㺚㺯  㺮㺔㺼㺕ᖹᗙ㔠
 52+6   0686 
6+,0 )/$7:$6+(5
&2'( &2'(
12  12 
㺚㺯  㺞㺻㺖㺔㺼㺐㺢㺼⤌ရ
 52+6   &+ 
6+,0 7$1.*8,'($66(0%/<
&2'( &2'(
12  12 
㺚㺯  භゅ㺬㺼㺷㺢඲㺦㺚㺼
 52+6   0;686 
6+,0 +(;%2/7
&2'( &2'(
12  12 
㺚㺎㺷๣ሬᕸせ㡿᭩ භゅ㺣㺍㺢㺚㺋
 -   0686 
+2:72$33/<7+( +(;187
6($/$17 &2'( &2'(
12  12 
㺮㺔㺼㺕୸ᖹᗙ㔠
 0686 
)/$7:$6+(5
&2'(
12 
㺨㺼㺦ᗙ㔠
 0686 
635,1*:$6+(5
&2'(
12 

㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧 㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧

㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂 㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂
&0/  &0& 
A-23
&2'(12  $9; 
7<3( &+1 

ᕤ஦ᮦᩱ⾲
,167$//$7,210$7(5,$/6
␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃
12 1$0( 287/,1( '(6&5,37,216 4
7< 5(0$5.6
㺕㺧㺵㺛㺞
  *㺐㺶 
$17,&25526,9(6($/$17
&2'(
12 
㺚㺎㺷㺙㺼㺐
 㺹㺍㺖㺞㺐㺢12 0/ 
6($/$17
&2'(
12 
㺬㺼㺎㺷㺸㺻㺟
 7:% 
%$//:5(1&+
&2'(
12 
㺚㺯 
 52+6 
6+,0
&2'(
12 
㺚㺯 
 52+6 
6+,0
&2'(
12 
㺚㺯 
 52+6 
6+,0
&2'(
12 
㺚㺎㺷๣ሬᕸせ㡿᭩
 - 
+2:72$33/<7+(
6($/$17 &2'(
12 

㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧

㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂
&0& 
Y. Hatai
D-1
Y. Hatai
D-2
Y. Hatai
D-3
19/M ar/2015 H .M A KI
D-4
30/M ar/2015 H .M A KI
D-5
30/M ar/2015 H .M A KI
D-6
D-7

12/Apr/2019 H.MAKI
Y.H atai
D-8
D-9

Y. Hatai
D-10

Y. Hatai
D-11

Takahashi T.
Takahashi T.
D-12
D-13

17/S ep/2014 H .M A KI
23/Oct/08 R.Esumi
D-14
25/Jul/2016 H.MAKI
D-15
D-16
D-17

13/Dec/2018 H.MAKI
D-18

8/May/2013 H.MAKI
D-19

26/Jun/2014 H .M A KI
D-20
D-21

3/Sep/2013 H.MAKI
D-22
D-23
D-24

7/Jul/2017 H.MAKI
S-1
1 2 3 4 5 6

送受信装置 操作/表示部 CONTROL/DISPLAY UNIT CH-302/MU-100C


上下装置 TRANSCEIVER UNIT
HULL UNIT 上下動部 CH-303 3B1 CPU 06P0254 表示部 操作部
CH-304 400mmストローク RAISE/LOWER DRIVE UNIT MONITOR UNIT MJ-A10SPF MJ-A10SPF CONTROL UNIT
TRAVEL CH-3041 XHP-20 J2 MU-100C *4 *3 CH-302 *4 *3
DATA/VIDEO OUT
CH-305 250mmストローク CH-3051 4B2 PRA 06P0257 1 PWRON-H DATA/VIDEO IN CONT MJ-A10SPF0002,φ9 DISP REM MJ-A7SPF
J1 XM2A-2501 XM2A-2501 0.15/1.5/5m 5m
TRAVEL J1 VHR-4N 2 PWRON-C R 1 1 R TRXTD-A 1 1 TRXTD-A REMS0-N 1
A TR1 1 3 RLCONT-H G 2 2 G TRXTD-B 2 2 TRXTD-B REMS1-N 2
TR2 2 4 RLCONT-C B 3 3 B CONTD-A 3 3 CONTD-A REMR0-N 3
旋回俯仰部 TD GND 3 5 TRM1-H HS-N 4 4 HS-N CONTD-B 4 4 CONTD-B REMR1-N 4
SOUNDOME NC 4 6 TRM1-C

HULL UNIT
*3 VS-N 5 5 VS-N PSW-H 5 5 PSW-H REMR2-N 5
CH-3042 VHR-3N J2 J3 XHP-3 7 TRM2-H YC-N 6 6 YC-N PSW-C 6 6 PSW-C +12V 6
1 TD1 SIGP+ 1 8 TRM2-C TRXTD-A 7 7 TRXTD-A +12V 7 7 +12V GND 7
5B1 DOM 06P0244

TRX
*3 2 TD2 SIGP- 2 *3 9 TIM1-H CONTD-A 8 8 CONTD-A GND 8 8 GND
*3
J2 VHR-3N 3 TD GND NC 3 06S4080 10 TIM1-C TD-A 9 9 TD-A SCAN-REV 9 9 SCAN-REV
06S4078,5/10m,φ12
SOUNDOME
TD1 1 15/30/50m 11 TIM2-H RD-A 10 10 RD-A F.GND 10 10 F.GND
TD2 2 φ13.7 12 TIM2-C
4B1 DRV 06P0243 PSW-H 11 11 PSW-H
TD GND 3 *3 *3 13 HULLV-H 12VA 12 12 12VA *2
J1 XHP-12 XHP-12 J2 J1 XHP-20 14 UPLMT-H 0V 13 13 12VA-GND IV-2sq.
TIP1 1 1 TIP1 PWRON-H 1 15 DNLMT-H R-GND 14 14 R-GND
TIP3 2 2 TIP3 PWRON-C 2 16 TR0-H G-GND 15 15 G-GND
06S4081,3.5/5.2m

TIP2 3 3 TIP2 RLCONT-H 3 17 F0-H B-GND 16 16 B-GND リモートコントローラ


TIP4 4 4 TIP4 RLCONT-C 4 18 F1-H HS-N-GND 17 17 HS-N-GND REMOTE CONTROLLER *2
TRP1 5 5 TRP1 TRM1-H 5 19 F2-H VS-N-GND 18 18 VS-N-GND CH-256
TRP3 6 6 TRP3 TRM1-C 6 20 COM_C YC-N-GND 19 19 YC-N-GND
TRP2 7 7 TRP2 TRM2-H 7 *3
TRXTD-B 20 20 TRXTD-B MJ-A6SPF0011(6P-4P)
TRP4 8 8 TRP4 TRM2-C 8 H7P-SHF J3 NMEA MJ-A6SPF
CONTD-B 21 21 CONTD-B MJ-A6SPF0012(6P-6P) 航法装置
B TR0 9 9 TR0 TIM1-H 9 1 +12V TXD-B 22 22 TD-B
TD-A 1
5/10m,φ6.1 NAV. EQUIPMENT
+12V 10 10 +12V TIM1-C 10 2 KPO EXTERNAL TD-B 2
KP/SIG RD-C 23 23 RD-B IEC61162-1(NMEA)
GND 11 11 GND TIM2-H 11 3 KPI RD-H 3
PSW-C 24 24 PSW-C
GND 12 12 GND TIM2-C 12 4 SIG RD-C 4
12VA 25 25 12VA
HULLV-H 13 5 EXT-SW NC 5
UPLMT-H 14 6 GND F.GND 6
DNLMT-H 15 7 SIG2 *1
TR0-H 16 IV-2sq.
TB2 F0-H 17 3B2 TRX 06P0255
1 (+)12/24VDC F1-H 18 VHR-4N J5
2 (-) F2-H 19 1 TR1
COM_C 20 2 TR2
3 TD GND
4 NC NMEA/
SATELLITE *3
XHP-3 J6 COMPASS *2
1 SIGP+ MJ-A6SPF MJ-A6SPF0003
*1 TD-A 1 シロ WHT
DPYCYS-2.5 2 SIGP- DATA OUT 1-5
12/24VDC 3 NC TD-B 2 クロ BLK
SPEAKER RD-H 3 キ YEL 1 TD-A サテライト
スピーカ *2 RD-C 4 ミドリ GRN 2 TD-B コンパス
C LOUDSPEAKER 5m φ3.5
GND 5 3 SATELLITE
CA-151S-ASSY GND 6 4 COMPASS *2
CA-150BS-ASSY MOTION SC-50/110
SENSOR SRCN2A
13-5S *2
3B3 PWR 06P0256 S06-6-10(5-5P),10m,φ9.2 動揺検出器 *2
12VB 1 MOTION SENSOR
*1 TB1 ROLL 2
DPYCYS-2.5 MS-100
12-24VDC 1 (+)12-24VDC PITCH 3 または OR
*1 2 (-) GND 4 サテライトコンパスSC-50/110はアナログ出力を
100/110/115/ DPYC(Y)-1.5 傾斜角検出器
GND 5 CLINOMETER *2 MONITOR SENSORポートに接続することも可能
200/220/230VAC THE SATELLITE COMPASS SC-50/110 CAN BE
1φ, 50/60 Hz BS-704 CONNECTED TO "MONITOR SENSOR" PORT (ANALOG SIG.)
1 2 5 6
*1
整流器 (+)(-) IV-2sq.
MOTION *2
RECTIFIER SENSOR SRCN2A
RU-1746B-2 13-5S SC-50/110
12VB 1 *1 J11 ROLL
*1 2 TTYCS-1Q 1 ROLL
ROLL
IV-8sq.
PITCH 3 2 SG
GND 4 J12 PITCH
GND 5 1 PITCH
D 注記
2 SG

*1)造船所手配。
*2)オプション。
*3)コネクタは工場で取付済み。
*4)表示部はMU-100Cの代わりにMU-151Cを使用することも可能。
   ただし、MU-151Cには電源接続が必要。
DRAWN TITLE
16/Apr/2019 T.YAMASAKI CH-300
NOTE CHECKED 名称 2周波サーチライトソナー
*1: SHIPYARD SUPPLY. 16/Apr/2019 H.MAKI
*2: OPTION. APPROVED
17/Apr/2019 H.MAKI 相互結線図
*3: CONNECTOR PLUG IS FITTED AT FACTORY. SCALE MASS NAME
*4: THE MONITOR UNIT MU-151C CAN BE USED INSTEAD OF MU-151C. kg DUAL-FREQUENCY SEARCHLIGHT SONER
HOWEVER, THE MU-151C MUST BE POWERED FROM SHIP'S MAINS. DWG.No. REF.No.
C1325-C01- E A06-023-3001-0 INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4 5 6
S-2

送受信装置
上下装置 TRANSCEIVER UNIT インターフェイスユニット
HULL UNIT 上下動部 CH-303 3B1 CPU 06P0254 INTERFACE UNIT
CH-304 400mmストローク RAISE/LOWER DRIVE UNIT DATA/VIDEO OUT IF-8000
TRAVEL CH-3041 XHP-20 J2 J1 XM2A-2501 XM2A-2501 DATA/VIDEO IN RGB OUT D-SUB15P
CH-305 250mmストローク CH-3051 4B2 PRA 06P0257 1 PWRON-H R 1 1 R RED 1 外部モニター
TRAVEL J1 VHR-4N 2 PWRON-C G 2 2 G GREEN 2 VGA MONITOR
A TR1 1 3 RLCONT-H B 3 3 B BLUE 3
TR2 2 4 RLCONT-C HS-N 4 4 HS-N NC 4
旋回俯仰部 TD GND 3 5 TRM1-H VS-N 5 5 VS-N GND
NC 5
SOUNDOME NC 4 6 TRM1-C YC-N 6 6 YC-N GND 6

HULL UNIT
*3
CH-3042 VHR-3N J2 J3 XHP-3 7 TRM2-H TRXTD-A 7 7 TRXTD-A GND 7
1 TD1 SIGP+ 1 8 TRM2-C CONTD-A 8 *3, *4 8 CONTD-A GND 8
5B1 DOM 06P0244

TRX
*3 2 TD2 SIGP- 2 *3 9 TIM1-H TD-A 9 06S4078,5/10m,φ12 (A) 9 TD-A NC 9
J2 VHR-3N 3 TD GND NC 3 06S4080 10 TIM1-C RD-A 10 10 RD-A GND 10
リモートコントローラ
SOUNDOME
TD1 1 15/30/50m 11 TIM2-H PSW-H 11 11 PSW-H NC
GND 11
TD2 2 φ13.7 12 TIM2-C 12VA 12 12 12VA NC 12
REMOTE CONTROLLER *2
TD GND 3
4B1 DRV 06P0243
13 HULLV-H 0V 13 13 12VA-GND HSYNC 13
CH-256
*3 *3
J1 XHP-12 XHP-12 J2 J1 XHP-20 14 UPLMT-H R-GND 14 14 R-GND VSYNC 14

5m
TIP1 1 1 TIP1 PWRON-H 1 15 DNLMT-H G-GND 15 15 G-GND NC 15 操作部
TIP3 2 2 TIP3 PWRON-C 2 16 TR0-H B-GND 16 16 B-GND CONTROL UNIT
06S4081,3.5/5.2m

TIP2 3 3 TIP2 RLCONT-H 3 17 F0-H HS-N-GND 17 17 HS-N-GND *3 *3 CH-302 *5 *3


TIP4 4 4 TIP4 RLCONT-C 4 18 F1-H VS-N-GND 18 18 VS-N-GND CONT MJ-A10SPF *2 MJ-A10SPF DISP REM MJ-A7SPF
19 YC-N-GND MJ-A10SPF0002,1.5/5m,φ9
TRP1 5 5 TRP1 TRM1-H 5 19 F2-H YC-N-GND 19 TRXTD-A 1 1 TRXTD-A REMS0-N 1
TRP3 6 6 TRP3 TRM1-C 6 20 COM_C TRXTD-B 20 20 TRXTD-B TRXTD-B 2 2 TRXTD-B REMS1-N 2
TRP2 7 7 TRP2 TRM2-H 7 CONTD-B 21 21 CONTD-B CONTD-A 3 3 CONTD-A REMR0-N 3
TRP4 8 8 TRP4 TRM2-C 8 H7P-SHF J3 TXD-B 22 22 TD-B CONTD-B 4 4 CONTD-B REMR1-N 4
B TR0 9 9 TR0 TIM1-H 9 1 +12V RD-C 23 23 RD-B PSW-H 5 5 PSW-H REMR2-N 5
+12V 10 10 +12V TIM1-C 10 2 KPO EXTERNAL PSW-C 24 24 PSW-C PSW-C 6 6 PSW-C +12V 6
KP/SIG 25 12VA
GND 11 11 GND TIM2-H 11 3 KPI 12VA 25 +12V 7 7 +12V GND 7
GND 12 12 GND TIM2-C 12 4 SIG GND 8 8 GND
HULLV-H 13 5 EXT-SW SCAN-REV 9 9 SCAN-REV
UPLMT-H 14 6 GND F.GND 10 10 F.GND
DNLMT-H 15 7 SIG2
TR0-H 16 *3 *1
3B2 TRX 06P0255 MJ-A6SPF MJ-A6SPF0011(6P-4P) *5 IV-2sq.
TB2 F0-H 17 NMEA
MJ-A6SPF0012(6P-6P) 航法装置
1 (+)12/24VDC F1-H 18 TD-A 1
VHR-4N J5 5/10m,φ6 NAV. EQUIPMENT
2 (-) F2-H 19 1 TR1 TD-B 2
COM_C 20 RD-H 3 IEC61162-1(NMEA)
2 TR2
3 TD GND RD-C 4
4 NC NC 5
F.GND 6
XHP-3 J6
1 SIGP+ DATA/VIDEO OUT
*1 *4
DPYCYS-2.5 2 SIGP- (B) MU-100C, MU-151C
12/24VDC 3 NC CH-303の 1
OR


SPEAKER ポートと同じ IF-8000
スピーカ *2 φ3.5 NMEA/ SAME AS THE 25
C LOUDSPEAKER 5m SATELLITE *3 *2
PORT OF CH-303
CA-151S-ASSY COMPASS MJ-A6SPF MJ-A6SPF0003
CA-150BS-ASSY 1 *1
TD-A シロ WHT IV-2sq.
TD-B 2 クロ BLK DATA OUT 1-5
RD-H 3 キ YEL 1 TD-A サテライト
3B3 PWR 06P0256 4 2 TD-B コンパス
RD-C ミドリ GRN
*1 TB1 GND 5 3 SATELLITE
DPYCYS-2.5
12-24VDC 1 (+)12-24VDC GND 6 4 COMPASS *2
*1 2 (-)
100/110/115/ DPYC(Y)-1.5 MOTION SC-50/110
SENSOR SRCN2A
200/220/230VAC *2 サテライトコンパスSC-50/110はアナログ出力を
13-5S 動揺検出器 *2
1φ, 50/60 Hz 1 2 5 6 12VB 1
S06-6-10(5-5P),10m,φ9.2 MONITOR SENSORポートに接続することも可能
MOTION SENSOR THE SATELLITE COMPASS SC-50/110 CAN BE
整流器 (+)(-) ROLL 2 MS-100 CONNECTED TO "MONITOR SENSOR" PORT (ANALOG SIG.)
*2 PITCH 3
RECTIFIER または OR
RU-1746B-2 GND 4 傾斜角検出器
GND 5 MOTION *2
*1 CLINOMETER *2 SENSOR SRCN2A
SC-50/110
BS-704 13-5S
IV-8sq. *1 J11 ROLL
*1 12VB 1
2 TTYCS-1Q 1 ROLL
IV-2sq. ROLL
注記 PITCH 3 2 SG
D *1)造船所手配。 GND 4 J12 PITCH
*2)オプション支給。 GND 5 1 PITCH
2 SG
*3)コネクタは工場で取付済み。
*4)送受信装置から表示部MU-100Cまたは第2IF-8000までのケーブル長の合計は15m以下であること(A+B≦15)。
*5)IF-8000の「DATA/VIDEO OUT」ポートにオプションの表示部MU-100Cを接続した場合、
   操作部および航法装置はIF-8000かMU-100Cのどちらか一方に接続可能)。
NOTE DRAWN TITLE
16/Apr/2019 T.YAMASAKI CH-300
*1: SHIPYARD SUPPLY.
CHECKED 名称
*2: OPTION. 16/Apr/2019 H.MAKI 2周波サーチライトソナー(I/Fユニット使用)
*3: CONNECTOR PLUG IS FITTED AT FACTORY. APPROVED
17/Apr/2019 H.MAKI 相互結線図
*4: CABLE LENGTH BETWEEN TRANSCEIVER AND MONITOR UNIT (MU-100C) OR 2ND I/F UNIT SHOULD BE 15 m OR LESS (A+B≦15). MASS
SCALE NAME
*5: WHEN OPTIONAL MU-100C IS CONNECTED TO "DATA/VIDEO OUT" OF IF-8000, BOTH CONTROL UNIT AND NAVIGATIONAL EQUIPMENT kg DUAL-FREQUENCY SEARCHLIGHT SONER (W/ I/F UNIT)
CAN BE CONNECTED TO MU-100C OR IF-8000 UNIT. DWG.No. REF.No.
C1325-C02- F A06-023-3001-0 INTERCONNECTION DIAGRAM